• Title/Summary/Keyword: maximum Von-Mises stress

Search Result 209, Processing Time 0.024 seconds

Design of a column for streetlamp considering the car crash (승용차 충돌을 고려한 가로등주 설계)

  • Lim, Jaemoon;Lee, Kwangwon
    • Journal of Auto-vehicle Safety Association
    • /
    • v.5 no.2
    • /
    • pp.57-61
    • /
    • 2013
  • A column for streetlamp has been damaged by severe wind loads such as typhoon. The stress concentration around the inspection hole may cause the collapse of the column for streetlamp. In this paper, the effects due to the wind load of 60 m/s and the car crash to the column at the speed of 48 km/h were considered to examine the design stability analysis of the column for streetlamp. The maximum von Mises stress did not exceed the yield stress of the material. Considering the car crash, the column for streetlamp was not collapsed.

Three dimensional finite element method for stress distribution on the length and diameter of orthodontic miniscrew and cortical bone thickness (교정용 미니스크류 식립 시 스크류의 길이, 직경 및 피질골 두께에 따른 응력 분포에 관한 3차원 유한요소법적 연구)

  • Lim, Jong-Won;Kim, Wang-Sik;Kim, Il-Kyu;Son, Choong-Yul;Byun, Hyo-In
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.11-20
    • /
    • 2003
  • The purpose of the present study is to evaluate the stress distribution on the length and diameter of the miniscrew and cortical bone width. Three dimensional finite element models were made of diameter 1.2mm, 1.6mm, 2.0mm and length 6.0mm, 8.0mm, 10.0mm, 12.0mm and cortical bone width 1.0mm. Also, another three dimensional finite element models were made of diameter 1.2mm, 1.6mm, 2.0mm and length 8.0mm and cortical bone width 1.0mm, 1.5mm, 2.0mm, 2.5mm. Two-hundred grams horizontal force were applied on the center of the miniscrew head and at that stress distribution and its magnitude had been analyzed by ANSYS, which is three dimensional finite element analysis program. The obtained results were as follows : 1. The comparison of the maximum von-Mises stress in the miniscrew showed that as the diameter increases from 1.2mm to 2.0mm stress has been decreased, while on the same diameter stress was not changed regardless of the length change. 2. The comparison of the maximum von-Mises stress in the cortical and cancellous bone showed that as the diameter increases from 1.2mm to 2.0mm stress has been decreased, while on the same diameter stress was not changed regardless of the length change. 3. In the analysis of the stress distribution in the cortical and cancellous bone, the most of the stress had been absorbed in the cortical bone, and did not transmitted much to the cancellous bone. 4. In the analysis of the maximum von-Mises stress according to the cortical bone width, the same diameter of the miniscrew showed a constant stress value regardless of the cortical bone width change. The above results suggest that the maintenance of the miniscrew is more reliable on diameter than length of the miniscrew.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION ACCORDING TO THE THREAD DESIGNS AND THE MARGINAL BONE LOSS OF THE IMPLANTS (임프란트 나사형태와 치조골 흡수에 따른 응력분산의 3차원 유한요소법적 분석)

  • Kim, Il-Kyu;Son, Choong-Yul;Jang, Keum-Soo;Cho, Hyun-Young;Baek, Min-Kyu;Park, Sheung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.60-71
    • /
    • 2008
  • The objective of this study is to evaluate the stress distribution according to the thread design and the marginal bone loss of a single unit dental implant under the axial and offset-axial loading by three dimensional finite element analysis. The implants used had the diameter of 5mm and 4mm with 13mm in length and prosthesis with a conical type which is 6mm in height and 12mm in diameter. The thread designs were triangular, square and buttress. In the three dimensional finite element model with $15\times15\times20mm$ hexahedron and 2mm cortical thickness, implants were placed with crown to root ratio 7:12, 10:9, 13:6 and 16:3. And additionally the axial force of 100N were applied into 0mm, 2mm and 4mm away from the center of the implants. The results were as follows 1. The maximum von-Mises stress in cortical bone was concentrated to cervical area of implant, and in cancellous bone, apical portion. 2. Comparing the von-Mises stresses in cortical bone of 2mm and 4mm offset loading with central axial loading, it were increased to 3 and 5 times in diameter 4mm implant, and 2 and 4 times, in diameter 5mm implant. 3. The square threads were more effective than the triangular and butress as the longer diameter, the offset loading, and the worse crown to root ratio. 4. The von-Mises stresses were relatively stable until crown to root ratio 13:6, but it was suddenly increased at 16:3. From the results of this study, minimum requirement of crown to root ratio of implant is 2:1, and in the respect of crown to root ratio, diameter and offset loading, square threads are more effective than triangular and buttress threads.

Finite element analysis of the artery and PTFE end-to-side anastomosis with $45^{\circ}$ anastomotic angle. ($45^{\circ}$ 문합각을 가진 동맥과 PTFE 단측 문합의 유한요소해석.)

  • Han, Geun-Jo;Kim, Hyung-Tae;Shin, Jung-Woog;Kim, Young-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.104-108
    • /
    • 1995
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the anastomosis of an artery with length of 20mm, inner diameter of 4mm, thickness of 0.5mm and a PTFE graft with length of 5.7mm, Inner diameter of 2mm. thickness of 0.2mm. When anastomotic angle was taken as $45^{\circ}$ and inner pressure of $1330\;dyne/mm^2$ was applied inside the 2 conduits. From the analysis results were obtained as follows. (1)Artery diameter increased in both horizontal x and vertical y directions and the magnitude of that in x direction was bigger than in y direction. (2) The compliance was maximum on the anastomosis. especially on that with acute angle. This reduced approaching to the right or left end. (3) The equivalent stress was maximum on top in the y direction and winimum on the nodes around $110^{\circ}$ in circumferential direction from the top. (4) The equivalent stress was maximum in the vicinity of anastomosis with acute angle along the longitudinal direction of the artery. This trend was also observed along the PTFE graft.

  • PDF

Static and Dynamic Stability Estimation of Diecutter (타발기의 정적 및 동적 안정성 평가)

  • Son, Jae-Hwan;Han, Chang-Woo;Lee, Sang-Ryong;Lee, Choon-Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.3
    • /
    • pp.27-32
    • /
    • 2009
  • In this study, static and dynamic stability estimations on the diecutter with finite element modelling were carried out to be creased and cut away printed sheet exactly. To cut away the sheet exactly, the large force should be pressured on diecutter. And which affects not only the quality of produced sheets but also the stability of diecutter. The analyses with and without the tare of diecutter were carried out with NASTRAN software on applying 400 ton force to its top and moving table respectively. It was known that maximum von-Mises stress of 221 Mpa in diecutter was occurred at the toggle, and it was smaller than the yield stress of 280 Mpa. And maximum deformation of 0.75 mm was occurred at the top table. The natural frequencies of 41, 102, 108, 115, and 134 Hz for the 1st, 2nd, 3rd, 4th and 5th mode, which had been determined by numerical simulation, were not coincided with the max. speeds of motor and moving table of 29 and 2 Hz. And which was verified by vibration test. Therefore it may be estimated that the structure of the diecutter is statically and dynamically stable.

  • PDF

Behavior characteristics of hydrogen storage vessel(TYPE 1) under gas pressure and temperature conditions using FEM (유한요소법을 이용한 수소저장용기 TYPE 1의 압력과 온도조건에 의한 거동특성 연구)

  • Cho, Seunghyun;Kim, Young Gyu;Ko, Young Bae;Lee, Il Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.61-69
    • /
    • 2020
  • This paper is a study of the behavior characteristics that occur in the hydrogen storage vessel TYPE 1 according to pressure and temperature conditions by FEM(Finite element method). Von Mises stress (VMS) generated at the highest pressure was compared with Yield strength (YS) of the material for structural safety assessment of the container, and the results of plastic strain energy density (PSED) were analyzed as basic data for life expectancy. According to the analysis results, the safety of the hydrogen gas storage vessel is not ensured due to the occurrence of VMS higher than the yield strength on the bottom of the storage container at a gas pressure of 40 Mpa or higher. In addition, the results of VMS caused by temperature conditions are very low and the behavior by temperature can be ignored. The maximum pressure of VMS/YS below 1 is calculated to be about 30 Mpa, indicating that the hydrogen storage container subject to this paper should be managed with a gas charging pressure of less than 30 Mpa.

A Numerical Analysis on the Stress Behavior Characteristics of a Pressure Vessel for Hydrogen Filling by FEM (유한요소법을 이용한 수소충전용 압력용기의 응력 거동특성에 관한 수치적 연구)

  • Chol, Seunghyun;Byonl, Sung Kwang;Kim, Yun Tae;Choi, Ha Young
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.3
    • /
    • pp.38-44
    • /
    • 2022
  • As the supply of hydrogen charging stations for hydrogen supply accelerates due to the hydrogen economy revitalization policy, the risk of accidents is also increasing. Since most hydrogen explosion accidents lead to major accidents, it is very important to secure safety when using hydrogen energy. In order to utilize hydrogen energy, it is essential to secure the safety of hydrogen storage containers used for production, storage, and transportation of liquid hydrogen. In this paper, in order to evaluate the structural safety of a hydrogen-filled pressure vessel, the behavioral characteristics of gas pressure were analyzed by finite element analysis. SA-372 Grade J / Class 70 was used for the material of the pressure vessel, and a hexahedral mesh was applied in the analysis model considering only the 1/4 shape because the pressure vessel is axisymmetric. A finite element analysis was performed at the maximum pressure using a hydrogen gas pressure vessel, and the von Mises stress, deformation, and strain energy density of the vessel were observed.

The effects of alveolar bone loss and miniscrew position on initial tooth displacement during intrusion of the maxillary anterior teeth: Finite element analysis

  • Cho, Sun-Mi;Choi, Sung-Hwan;Sung, Sang-Jin;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.310-322
    • /
    • 2016
  • Objective: The aim of this study was to determine the optimal loading conditions for pure intrusion of the six maxillary anterior teeth with miniscrews according to alveolar bone loss. Methods: A three-dimensional finite element model was created for a segment of the six anterior teeth, and the positions of the miniscrews and hooks were varied after setting the alveolar bone loss to 0, 2, or 4 mm. Under 100 g of intrusive force, initial displacement of the individual teeth in three directions and the degree of labial tilting were measured. Results: The degree of labial tilting increased with reduced alveolar bone height under the same load. When a miniscrew was inserted between the two central incisors, the amounts of medial-lateral and anterior-posterior displacement of the central incisor were significantly greater than in the other conditions. When the miniscrews were inserted distally to the canines and an intrusion force was applied distal to the lateral incisors, the degree of labial tilting and the amounts of displacement of the six anterior teeth were the lowest, and the maximum von Mises stress was distributed evenly across all the teeth, regardless of the bone loss. Conclusions: Initial tooth displacement similar to pure intrusion of the six maxillary anterior teeth was induced when miniscrews were inserted distal to the maxillary canines and an intrusion force was applied distal to the lateral incisors. In this condition, the maximum von Mises stresses were relatively evenly distributed across all the teeth, regardless of the bone loss.

High Cycle Fatigue Damage under Multiaxial Random Loading through Dynamic Simulation for an Automotive Sub-Frame (동력학 시뮬레이션에 의한 다축 랜덤하중 하에서 자동차 서브프레임의 고 되풀이수 피로손상 평가)

  • Lee, Hak-Joo;Kang, Jae-Youn;Choi, Byung-Ick;Kim, Joo-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.6
    • /
    • pp.946-953
    • /
    • 2003
  • A FEM-based analytical approach was used to evaluate the multiaxial high cycle fatigue damage of an automotive sub-frame. Elastic Multi Body Simulation (MBS) has been applied in order to determine the multiaxial load histories. The stresses due to these loads have been given by FE computation. These results have been used as the input for the multiaxial fatigue analysis. For the assessment of multiaxial high cycle fatigue damage, the signed von Mises, the signed Tresca, the absolute maximum principal stress and critical plane methods have been employed. In addition, the biaxiality ratio, a$\sub$e/, the absolute maximum principal stress, $\sigma$$\sub$p/ and the angle, $\phi$$\sub$P/, between $\sigma$$\sub$1/ and the local x-axis, have been calculated to evaluate the stress state at each node.

Finite element stress analysis according to the point and surface occlusal loads on the implant prosthesis (임플란트 보철물의 점하중과 면하중에 따른 유한요소법적 응력 분석)

  • Choi, Min-Ho;Kang, Jae-Suek;Boo, Soo-Bung;Oh, Snag-Ho;An, OK-Ju;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.83-94
    • /
    • 2004
  • The purpose of this study was to compare the distributing pattern of stress according to the types of occlusal load on the finite element models of the splinted implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on mandibular first and second molars. The cemented crowns for mandibular first and second molars were made. Three-dimensional finite element model was created with the components of the implant, surrounding bone and cemented crowns. Two types of occlusal load, the point load and the surface load within 0.5 mm radius circle, were applied to the finite element models with 200N magnitude in axial(along the long axis of the implant and oblique(angulation of $30^{\circ}$ to the long axis) directions perpendicular to cuspal incline. Loads were positioned from the center of central fossa and to distance of 2 mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the fixtures and sections. The results were as following : 1. Under axial loading at the central fossa, the stress was distributed along the fixture except for the apical portion, not relative to both point & surface contacts. 2. With offset distance increasing, the highest stresses were concentrated in the neck portion of the fixture. 3. The maximum von Mises stress under the oblique load was greater than that under the axial load. 4. Under the oblique load, the highest stress were concentrated in the buccal side and lingual neck portion of the fixture with offset distance increasing. The results had a tendency to increase the stress on the neck portion of fixture with the offset and oblique loads increasing. The design of occlusal scheme should be allowed to distribute stress axially in maximum intercuspation and to decrease the angulation of cuspal incline.