Finite element analysis of the artery and PTFE end-to-side anastomosis with $45^{\circ}$ anastomotic angle.

$45^{\circ}$ 문합각을 가진 동맥과 PTFE 단측 문합의 유한요소해석.

  • Published : 1995.05.12

Abstract

Von Mises stress and compliance distribution was evaluated using a finite element analysis on the anastomosis of an artery with length of 20mm, inner diameter of 4mm, thickness of 0.5mm and a PTFE graft with length of 5.7mm, Inner diameter of 2mm. thickness of 0.2mm. When anastomotic angle was taken as $45^{\circ}$ and inner pressure of $1330\;dyne/mm^2$ was applied inside the 2 conduits. From the analysis results were obtained as follows. (1)Artery diameter increased in both horizontal x and vertical y directions and the magnitude of that in x direction was bigger than in y direction. (2) The compliance was maximum on the anastomosis. especially on that with acute angle. This reduced approaching to the right or left end. (3) The equivalent stress was maximum on top in the y direction and winimum on the nodes around $110^{\circ}$ in circumferential direction from the top. (4) The equivalent stress was maximum in the vicinity of anastomosis with acute angle along the longitudinal direction of the artery. This trend was also observed along the PTFE graft.

Keywords