• Title/Summary/Keyword: maxillary

Search Result 3,284, Processing Time 0.038 seconds

Dentoalveolar compensation according to skeletal discrepancy in Normal occlusion (전후방적 악골 관계에 따른 치아치조성 보상작용에 관한 연구)

  • Shim, Hae-Young;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.380-393
    • /
    • 2004
  • The Purpose of this study was to investigate the dentoalveolar compensation according to anteroposterior skeletal discrepancy in normal occlusion and to evaluate cephalometric parameters that quantitatively describe dental compensations. The study consisted of 90 subjects (50 males. 40 females) who were selected among specimens of normal occlusion at Seoul National, University Dental Hospital, Dept. of Orthodontics. Lateral cephalograms in centric occlusion were traced and digitized for each subject. According to the anteroposterior skeletal pattern the sample was divided into three groups. Cephalometric data were analyzed for the three groups using the SPSS program. Independent t-test, correlation analysis and regression analysis were carried out. The results were as fellows: Dentoalveolar compensation was found in upper and lower incisor inclination and occlusal plane inclination. As the mandible located anterior to the maxilla, the maxillary incisors incisors more labially. the mandibular incisors more lingually, and the occlusal plane continued to flatten. The dental parameters most correlated with anteroposterior skeletal discrepancy were L1 to SN and L1 to FH. Among the compensatory dentoalveolar changes, lower incisor inclination was strongly related to the anteroposterior jaw relationship and played au imposrtant role in obtaining a normal incisor relationship U1 to PtGn and L1 to APog were constant irrelevant to anteroposterior skeletal discrepancy.

THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS (치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 -)

  • Lee Yong-Keun;Lee Keon-Il;Jung Sung-Woo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

Fracture patterns in the maxillofacial region: a four-year retrospective study

  • Park, Kyung-Pil;Lim, Seong-Un;Kim, Jeong-Hwan;Chun, Won-Bae;Shin, Dong-Whan;Kim, Jun-Young;Lee, Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.306-316
    • /
    • 2015
  • Objectives: The facial bones are the most noticeable area in the human body, and facial injuries can cause significant functional, aesthetic, and psychological complications. Continuous study of the patterns of facial bone fractures and changes in trends is helpful in the prevention and treatment of maxillofacial fractures. The purpose of the current clinico-statistical study is to investigate the pattern of facial fractures over a 4-year period. Materials and Methods: A retrospective analysis of 1,824 fracture sites was carried out in 1,284 patients admitted to SMG-SNU Boramae Medical Center for facial bone fracture from January 2010 to December 2013. We evaluated the distributions of age/gender/season, fracture site, cause of injury, duration from injury to treatment, hospitalization period, and postoperative complications. Results: The ratio of men to women was 3.2:1. Most fractures occurred in individuals aged between teens to 40s and were most prevalent at the middle and end of the month. Fractures occurred in the nasal bone (65.0%), orbital wall (29.2%), maxillary wall (15.3%), zygomatic arch (13.2%), zygomaticomaxillary complex (9.8%), mandibular symphysis (6.5%), mandibular angle (5.9%), mandibular condyle (4.9%), and mandibular body (1.9%). The most common etiologies were fall (32.5%) and assault (26.0%). The average duration of injury to treatment was 6 days, and the average hospitalization period was 5 days. Eighteen postoperative complications were observed in 17 patients, mainly infection and malocclusion in the mandible. Conclusion: This study reflects the tendency for trauma in the Seoul metropolitan region because it analyzes all facial fracture patients who visited our hospital regardless of the specific department. Distinctively, in this study, midfacial fractures had a much higher incidence than mandible fractures.

A COMPARATIVE STUDY OF VARIOUS TYPE OF AUTOGENEOUS BONE GRAFT ON THE RABBIT-SKULL DEFECT HEALING (가토 두개골에 이식한 다양한 형태의 자가골에 의한 골성 회복 양상 비교 평가)

  • Choi, So-Young;Lee, Su-Youn;Kim, Jin-Wook;Kim, Chin-Soo;Lee, Sang-Han;Shin, Hong-In;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.4
    • /
    • pp.428-434
    • /
    • 2008
  • Introduction: Piezosurgery device is one of the most commonly used instrument on the intraoral surgery such as maxillary sinus lift and autogeneous bone graft. Piezosurgery instrument also contains the tips that are manufactured especially for the convenient bone graft, which now many surgeons apply them for collecting bone graft materials in the curettage method for the restoration of skull defects. However, objective data has not been shown concerning the effects about bone graft with using Piezosurgery. Therefore we investigated the effects of Piezosurgery on the rabbit-skull defect healing. Materials & Methods: To investigate the regeneration of the bony defect with various bone graft, 10 adult New Zealand white rabbits (average weight : $2.8{\pm}0.3kg$, about 12weeks) were used. The four circular bony defects measuring 6mm in diameter were made with Piezosurgery device on each rabbit cranial bone. The harvested bone tissues during defect formation were also used for autogeneous bone graft. They were grafted into the defects in a various type; block type (Group 1), particulated type by the bone mill (Group 2), chopped type by curette shaped Piezosurgery tip (Group 3), the defect without any graft was served as control (control group). The animals were sacrificed after 6 weeks and bone regeneration capacity was evaluated histomorphometrically. Result & Conclusion: Autogeneous bone graft harvested using a Piezosurgery instrument showed satisfactory bone regeneration. There was no conspicuous difference bone prepared among by bone mill or Piezosurgery and block bone graft. Therefore, the bone harvested from the intraoral site near the operation field using the piezosurgery device can be a feasible and reliable graft for intraoral bony defects.

THE USE OF DISTRACTION OSTEOGENESIS TO TREAT HEMIFACIAL MICROSOMIA: A CASE REPORT (반안면 왜소증 환자에서의 골신장술: 증례보고)

  • Baik, Sung-Mun;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.559-566
    • /
    • 2007
  • Distraction osteogenesis(DO) is a surgical method of bone formation that involves an osteotomy and sequential stretching of the healing callus by gradual movement and subsequent remodeling. DO is used to correct facial asymmetry, such as in patients with hemifacial microsomia, maxillary or mandibular retrusion, cleft lip and palate, alveolar defects, and craniofacial deficiency. It is accomplished with the aid of a distraction device, which is secured with screws placed directly into bone, for a predetermined length of time. Hemifacial microsomia is characterized by unilateral facial hypoplasia, often with unilateral shortening of the mandible and subsequent malocclusion. Patients with hemifacial microsomia and facial asymmetry have a vertically short maxilla, tilted occlusal plane, and short mandible. Early treatment is necessary to avoid subsequent impaired midfacial growth. The standard treatment of these malformations consists of the application of bone grafts, which can lead to unpredictable growth. The new bone-lengthening procedure represents a limited surgical intervention and opens up a new perspective for treatment, especially in younger children with severe deformities. This report describes a case of hemifacial microsomia(Type-II left-sided hemifacial microsomia). The patient, a 10-year-old child, visited our clinic for facial asymmetry correction. He had a hypoplastic mandible, displaced ear lobe, 10 mm canting on the right side, and malocclusion. We planned DO to lengthen the left mandible in conjunction with a Le Fort I osteotomy for decanting and then perform a right intraoral vertical ramus osteotomy(IVRO). Progressive distraction at a rate of 0.5 mm/12 hours was initiated 7 days postoperatively. The duration of DO was 17 days. The consolidation period was 3 months. Satisfactory results were obtained in our case, indicating that DO can be used successfully for functional, aesthetic reconstruction of the mandible. We report a case involving DO in conjunction with orthognathic surgery for correcting mandibular hypoplasia with a review of the literature.

Effect of Porcelain Firing Process on the Marginal and Internal Fit of Ni-Cr Alloy Metal-Ceramic Crown (도재 소성과정이 Ni-Cr 금속도재관의 변연 및 내면 적합도에 미치는 영향)

  • Kim, Ki-Baek;Kim, Seok-Hwan;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.405-410
    • /
    • 2014
  • The purpose of this study in vitro investigation was to compare the marginal and internal fit of Ni-Cr alloy metal ceramic crown before and after porcelain veneering. Furthermore, this study evaluated whether the influence of the porcelain firing on the precision of fit of dental prostheses. The maxillary right incisor was selected as an abutment for experiments. Ten working models were prepared. Ni-Cr alloy cores appropriate for each abutment were prepared by lost wax technique. The marginal area and four internal areas of the crowns were measured at two stages: before veneering process and after upper porcelain firing. Silicone replica techniques were used. The data were statistically analyzed with the paired t-test (${\alpha}=0.05$). $Mean{\pm}SD$ marginal and internal gap were $67.1{\pm}23.3{\mu}m$ for the nickle chrome alloy core group and $74.4{\pm}21.9{\mu}m$ for the metal ceramic crown group. There were statistically significant differences in all investigated areas (p<0.05). Within the limitations of this study, none of the Ni-Cr alloy metal crown values measured after porcelain firing process exceeded $120{\mu}m$, which is the clinically acceptable threshold.

Comparative Analysis of Stress Distribution in Composite Resin Brackets with Metal Slot of Permanent Maxillary Central Incisor Using the Finite Element Method: A Pilot Study

  • Im, Jae-Jung;Song, Jae-Joon;Kim, Nan-Hee;Heo, Jin-Young;Jung, Gyu-Un;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Korean Dental Science
    • /
    • v.4 no.2
    • /
    • pp.46-51
    • /
    • 2011
  • Purpose: For aesthetic reasons, composite resin brackets are widely used. However, related studies are rare. This pilot study sought to compare the stress distributions in two commercially available composite resin brackets with metal slot. Materials and Methods: Two commercially available resin brackets -- full-metal slot resin bracket (fSRB) and partial-metal slot resin bracket (pSRB) with straight wire appliance dimension of $0.022{\times}0.028$ in -- were selected. In each bracket, 3-dimensional finite element models were constructed, and stress level was evaluated using finite element analysis. By loading the tipping force and torsion moment, which are similar to those applied by the stainless steel rectangular wire ($0.019{\times}0.025$ -in), stress distributions were calculated, and von Mises stress values were obtained. Results: In pSRB and fSRB, the stress value of the torque moment was much higher than that of the tipping force. The pSRB showed higher stress value than fSRB in both tipping force and torque moment because of the difference in size and configuration of the metal frame inserted into the slot. More stress was also found to be concentrated on the slot area than the wing area in fSRB. Conclusion: The slot form of fSRB was found to be more resistant to the stress of tipping and torque than the slot form of pSRB. In addition, the slot areas -- rather than the wing areas -- of the bracket showed breakage susceptibility. Therefore, resistance to the torque moment on the slot area should be considered in bracket design.

A Study of Facial Deformity in the Patient with Bilateral Cleft Lip before the Primary Cheiolplasty (양측성 구순열 환자의 안모 변형에 대한 연구)

  • Yoon Bo-Keun;Soh Byung-Soo;Baik Jin-Ah;Shin Hyo-Keun
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.4 no.2
    • /
    • pp.51-68
    • /
    • 2001
  • Midfacial hypoplasia in patients with clefts of the lip and palate is considered to be the result of congenital dysmorphogenesis. And cleft lip and palate developes facial deformity, jaw abnormality, speech problem, which is most frequent hereditary deformity in maxillofacial region. So cleft lip and palate is characterized by midface deformity which shaws maxillary anterior nasal septal deviation and deformity. Our study describes congenital correlates of midfacial hypoplasia by examining the displacement of a normal complement of parts, a triangular tissue deficiency low on the lip border on the columellar side, and a linear deficiency and displacement in the line of the bilateral cleft lip. 15 patients with bilateral cleft lip and palate were taken impression before operation, but the patient who had other abnormalities and complications were excluded. Average age is 3.4 months and they were classified into both complete, both incomplete and complete & incomplete group. The obtained results were as follows 1. There were no differences on intercanthal width and canthal width between each of the groups. 2. Both complete group had longer lateral ala length than both incomplete group, but there were no differences between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 3. Columella length was greater in both incomplete group than in both complete group, but there was no difference between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 4. Both complete group had longer ala width & ala base width than both incomplete group had. But there were no differences between both complete group and complete side of com. & incom. group and both incomplete group and incomplete side of com. & incom. group. 5. There were no differences between each of the groups on upper lip length, but nose/mouth width ratio was greater in both complete group than in both incomplete group. 6. Pronasale(pm), subnasle(sn), la~rale superioris(ls), stomion(sto) points were located around the central vertical line of face but deviated to incomplete side in com. & incom. group. 7. Nasal tip protrusion was greater in both incomplete group and com. & incom. group than both complete group, but there was no difference between both incomplete group and com. & incom. group.

  • PDF

AN ANALYSIS OF FAILURE MODE OF TEETH RESTORED WITH FIBER-REINFORCED POSTS UNDER THE CONDITION OF BONY RESORPTION (치주지지가 감소된 상태에서 섬유강화형 포스트로 수복한 치아의 실패양상 분석)

  • Lee Byung-Woo;Yi Yang-Jin;Cho Lee-Ra;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.232-242
    • /
    • 2003
  • Statement of problem : Fiber-reinforced posts have lower modulus of elasticity than titanium post or cast post-core. With this similar elasticity to that of dentin, fiber-reinforced posts have been known to have a tendency to reduce the risk of root fracture. However, there were few studies on the teeth restored with fiber-reinforced posts under the condition of reduced periodontal support. Purpose : The purpose of this study was to evaluate the fracture strength and failure mode of endodontically treated teeth restored with fiber-reinforced posts and titanium posts under the condition of reduced periodontal support. Material and method : Extracted human maxillary incisor roots were divided into 3 groups (group 1 carbon fiber post, group 2 : glass fiber post, and group 3 : titanium alloy post). After coronectomy and endodontic treatment, teeth were restored with each post systems and resin core according to the manufacturer's recommendation. Then, teeth with simulated periodontal ligament were embedded in the acrylic resin blocks at the level of 4 mm below the cemento-enamel junction. Each specimen was exposed to $10^5$ load cycles with average 30 N force in $36.5^{\circ}C$ water using a computer-controlled chewing simulator. Loads were applied at $45^{\circ}$ angle to the long axis of the teeth. After cyclic loading, teeth were subjected a compressive load until failure at a crosshead speed of 0.5 mm/min. Fracture strength (N) and failure mode were examined. The fracture strength was analyzed with one-way ANOVA and the Scheffe adjustment at the 95% significance level. Results and conclusion : The results were as follows. 1. There was no statistically significant difference in the mean fracture strength among the groups (P<.05). 2. Carbon fiber post and glass fiber post group showed less root fracture tendency than control group. 3. All specimens with root fractures showed fracture lines above the level of acrylic resin block, except for only one specimen in group 3.

Evaluation of the wear of the periodontal curet's cutting edge (치주 큐렛의 절단 연 마모도 평가)

  • Park, Eung-Joon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.575-584
    • /
    • 1997
  • The quality of periodontal instrument cutting edge is a basic element of effective root planing procedure. Using instruments, the sharp edge is changed into blunt or beveled edge. With the blunt instrument, the periodontal treatment can't be carried into accuracy and effective. The study on the wear of periodontal curet is insufficient, there are few publications about the change of sharpness of cutting egde after using instrument and a certen reports were published on the study of scanning electron microscope(SEM) examination. In this study, to declare the number of strokes for sharpening of instruments, the changes of cutting edge is measured by the clinical methods, tactile sensitivity examination and refraction light-white line test after scaling strokes and root planing strokes. SEM test was added for defined the changes of cutting edges. The 7/8 Gracey curets that have been never used was tested. Maxillary molars which were extracted from the School of Dental Medicine, Dankook University was used. Subjected teeth had attachment loss more than 6 mm in bucca-lingual surface and sufficient calculus of a band type in cervical area. The strokes of curet were executed 3, 5, 7, 9, 11, 13 times on scaling stroke and 10, 15, 20, 25, 30, 35 times on root planing stroke. A resident has periodontal experience over 3 years carried out the clinical examinations those tactile sensitivity examination and refraction light-white line test 5 times. The case there being tactile sensitivity certenly is 2, the case being felt tactile sensitivity is 1, and the case there not being tactile sensitivity is 0. The visual examination was recorded as following. The case that refracted white line is not recognised is 2, the case that uncerten is 1, and the case that acknowledged is 0. The results were obtained as follows. 1. After scaling strokes, the tactile sensitivity was reduced after 11 strokes and disappeared in 13 strokes. 2. In tactile sensitivity after root planing procedures, sensitivity was reduced after 25 strokes and disappeared in 35 strokes. 3. In case of visual examination, the detection of refracted white line was increased after 9 strokes of scaling procedures and the accuracy of wear wasn't showed after root planing procedures. 4. In SEM, metal projection was observed on new periodontal curet cutting edge and it was disappeared after scaling procedures. 5. In SEM, the cutting edge was showed changing linear into an aspect of the surface after 5 strokes of scaling procedures and 10 strokes of root planing procedures and showed beveled edge in 11 strokes of scaling procedures, 25 strokes of root planing procedures. The results of 3-type examination indicated that the sharpening of curet should be performed after 11 strokes of scaling procedures and 25 strokes of root planing procedures.

  • PDF