• Title/Summary/Keyword: material evaluation

Search Result 5,343, Processing Time 0.035 seconds

Studies on the durability evaluation of the Recycled Cement using Waste Cementitious Powder as Raw material. (폐미분말을 주원료로한 재생시멘트의 내구성능 평가에 관한 연구)

  • Kwon, Eun-Hee;Ahn, Jae-Cheol;Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.3-4
    • /
    • 2015
  • Environmental load reduction and sustainable development one of the study's research into the available material is discharged, remove the coarse aggregate and fine aggregate from waste concrete and utilizing the remaining cement fine powder as an alternative raw material for limestone is the main raw material of cement developing playback cement that was the purpose. Physical over existing research and chemical quality was confirmed was evaluated for durability by promoting carbonation test, research studies on the durability evaluation insignificant. As honipyul within the aggregate differential lung fine powder increases carbonation resistance performance've found that increased sharply and, S0 showed fairly similar to the OPC. Therefore, the development within the technology research to separate fine aggregate discharge fully differential and waste fine powder is determined to be the development and use of the playback durability of the cement with the carbonation levels corresponding to the OPC if made.

  • PDF

A Study on the Mechanical Property Evaluation of Carbon/Epoxy Composite Material for Aerospace Application (우주항공용 탄소/에폭시 복합재료의 기계적 특성 평가에 관한 고찰)

  • Lee, Ho-Sung;Min, Kyung-Ju
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.149-149
    • /
    • 2003
  • This paper presents the work peformed in a program developing composite material which properties satisfy structural and thermal requirements for aircrafts and spacecrafts. In the aerospace vehicle structures, the specific strength of the materials is one of the important requirements and this is why polymer matrix composite material with reinforced carbon fiber is widely used. However, the mechanical properties of the composite material have been known to be dependent on processing and this difficulties in evaluation have caused a lot of mechanical tests for each batch.

  • PDF

Characterization and Evaluation of Porous Vermiculite Containing Polyethylene Composites Film

  • Lee, Hye Sun;Chang, Jeong Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.1
    • /
    • pp.85-89
    • /
    • 2018
  • This work reported the preparation and evaluation of a freshness-keeping film prepared by composite of a porous ceramic material such as vermiculite and polyethylene polymer. The ceramic material was pretreated physically and chemically to control the specific surface areas and particle size. A high content master-batch was prepared using the pretreated vermiculite. The master-batch, which contained 30% ceramic material, was mixed with a polymer material to prepare a film containing 3% vermiculite. The oxygen permeability and various physicochemical properties were evaluated for the prepared films. Compared to plain polyethylene film, the vermiculite loaded polyethylene film has a freshness maintenance property, indicating the creation of an improved film.

Evaluation of Characteristics of Water Retaining Material for Water Retaining Pavement using High Absorptiveness Resin and Foamed Concrete (고흡수성 수지와 기포콘크리트를 이용한 보수성포장용 보수재 성능 평가)

  • Lee, Soo-Hyung;Yoo, In-Kyoon
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.321-324
    • /
    • 2008
  • Water retaining pavement is a pavement to lower the surface temperature by using evaporation of the water that the pavement contains when the pavement is heated by the sun in the daytime, so, to improve performance, the performance can absorb water. Most of the high-performance material that absorbs water swell $2\sim3$ times as much volume when it contact with water. Water retaining material exists independently of the material in the cement. so it doesn't have the space to expand. Therefore, the performance of absorbing water is decreased. Therefore, this study was to develop a foamed concrete and evaluation of performance characteristics using high absorptiveness resin. The result has been evaluated as excellent compared to other materials.

  • PDF

Development of Wall-Thinning Evaluation Procedure for Nuclear Power Plant Piping-Part 1: Quantification of Thickness Measurement Deviation

  • Yun, Hun;Moon, Seung-Jae;Oh, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.820-830
    • /
    • 2016
  • Pipe wall thinning by flow-accelerated corrosion and various types of erosion is a significant and costly damage phenomenon in secondary piping systems of nuclear power plants (NPPs). Most NPPs have management programs to ensure pipe integrity due to wall thinning that includes periodic measurements for pipe wall thicknesses using nondestructive evaluation techniques. Numerous measurements using ultrasonic tests (UTs; one of the nondestructive evaluation technologies) have been performed during scheduled outages in NPPs. Using the thickness measurement data, wall thinning rates of each component are determined conservatively according to several evaluation methods developed by the United States Electric Power Research Institute. However, little is known about the conservativeness or reliability of the evaluation methods because of a lack of understanding of the measurement error. In this study, quantitative models for UT thickness measurement deviations of nuclear pipes and fittings were developed as the first step for establishing an optimized thinning evaluation procedure considering measurement error. In order to understand the characteristics of UT thickness measurement errors of nuclear pipes and fittings, round robin test results, which were obtained by previous researchers under laboratory conditions, were analyzed. Then, based on a large dataset of actual plant data from four NPPs, a quantitative model for UT thickness measurement deviation is proposed for plant conditions.

Degradation Estimation Of Material by Barkhausen Noise Analysis (바크하우젠 노이즈 해석에 의한 재료의 열화도 평가)

  • Lee Myung Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.38-46
    • /
    • 2005
  • The destructive method is reliable and widely used for the estimation of material degradation but it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. In this study, various nondestructive evaluation(NDE) parameters of the Barkhausen noise method, such as MPA(Maximum Peak Amplitude), RMS, IABNS(Internal Area of Barkhausen Noise on Signal) and average amplitude of frequency spectrum are investigated and correlated with thermal damage level of 2.25cr-1.0Mo steel using wavelet analysis. Those parameters tend to increase while thermal degradation proceeds. It also turns out that the wavelet technique can help to reduce experimental false call in data analysis.

Color Quality Evaluation of High Color Rendering White LEDs According to Phosphor Types and Composition Ratio (형광체 종류와 조성비에 따른 고연색 백색 LED의 색품질 평가)

  • Jeong, Hee Suk;Ryeom, Jeongduk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.7
    • /
    • pp.463-468
    • /
    • 2017
  • Eight types of LED packages were manufactured according to the type and composition ratio of phosphors by using commercially available white LED phosphors. CRI (Ra), a conventional color quality evaluation method was evaluated by using manufactured white LED; the Rf, Rg, color vector graphic, and color distortion graphic were evaluated with a new method, IES TM-30-15. The results of the evaluation confirmed that the new method compensated for the disadvantages of CRI, which was found to be inadequate when the color was saturated. The added evaluation index identified the chroma variation and color change. Furthermore, the study showed that the changes of Rf and Rg are small when controlling phosphors based on CRI, questioningthe necessity of identifyingchroma variation and color change.

Ashpalt 2 Component Adhesive Leakage Repair Sealant Evaluation (아스팔트 2액형 점착재의 누수보수 평가에 관한 연구)

  • Cho, Il-Kyu;Kim, Keun-Hur;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.140-141
    • /
    • 2017
  • This study is based on the evaluation of a single component injection type adhesive repair material and a new 2 component type used in leakage of underground concrete structures. The studies showed that based on different mix ratio of the 2 component type adhesive sealant comprised of an asphalt main and latex mixture agent the viscosity of the material compound differed significantly. Based on a permeability testing, injection and economic efficiency, and performance, the appropriate ratio was determined to be 6:1 and was proceeded to the KS F 4935 evaluation method. The 2 component type adhesive sealant uses a static mixer and a cartridge type container for the injection procedure and was able to satisfy the evaluation criteria outlined in the KS F 4935 standard.

  • PDF

Study on Evaluation of Material Property of Micro Handpiece for dentistry and Surface Quality (치과용 시술기구(Micro Handpiece)재료의 특성평가 및 표면품질에 대한 연구)

  • Son, Jae-Hwan;Han, Chang-Woo;Choi, Sang-Il;Kim, Yong-Jung;Choi, Chang-Jin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.3
    • /
    • pp.221-228
    • /
    • 2006
  • As Industrialization gets more and more advanced, human technological medical apparatus for dentistry has been developed. Such a medical apparatus have to let precision revolution and torque control facilitate. Consequently, Development of Micro hand-piece with strong durability should be required. Moreover, It's also very important to evaluate performance of such a Micro hand-piece, Evaluation of Mechanical property of Material and ANOVA have been known as useful methods in the field of Quality Evaluation. For Verification of Quality Evaluation, It has been evaluated by One-way layout ANOVA based on the data of Surface Roughness Test. Anyhow, This test has been respectively carried out by 3 kinds of Test and Superior performance has appeared in the Test result.

  • PDF