• Title/Summary/Keyword: material evaluation

Search Result 5,366, Processing Time 0.043 seconds

Applying QFD in the Development of Sensible Brassiere for Middle Aged Women (QFD(품질 기능 전개도)를 이용한 중년 여성의 감성 Brassiere 개발)

  • Kim Jeong-hwa;Hong Kyung-hi;Scheurell Diane M.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.12 s.138
    • /
    • pp.1596-1604
    • /
    • 2004
  • Quality Function Deployment(QFD) is a product development tool which ensures that the voice of the customer needs is heard and translated into products. To develop a sensible brassiere for middle-aged women QFD was adopted. In this study the applicability and usefulness of QFD was examined through the engineering design process for a sensible brassiere for middle-aged women. The customer needs for the wear comfort of brassiere was made by one-on-one survey of 100 women who aged 30-40. The customer competitive assessment was generated by wearing tests of 10 commercial brassieres. The subjective assessment was conducted in the enviornmental chamber that was controlled at $28{\pm}1^{\circ}C,\;65{\pm}3\%RH.$ As a results, we developed twenty-one customer needs and corresponding HOWs for the wear comfort of brassiere. The Customer Competitive Assessment was generated by wearing tests of commercial brassiere. The subjective measurement scale and dimension for the evaluation of sensible brassiere were extracted from factor analysis. Four factors were fitting, aesthetic property, pressure sensation, displacement of brassiere due to movement. The most critical design parameter was wire-related property and second one was stretchability of main material of brassiere. Also, wearing comfort of brassiere was affected by the interaction of initial stretchability of wing and support of strap. Engineering design process, QFD was applicable to the development of technical and aesthetic brassieres.

Steady Shear Flow and Dynamic Viscoelastic Properties of Semi-Solid Food Materials (반고형 식품류의 정상유동특성 및 동적 점탄성)

  • 송기원;장갑식
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.143-152
    • /
    • 1999
  • Using a Rheometrics Fluids Spectrometer(RFS II), the steady shear flow and the small-amplitude dynamic viscoelastic properties of three kinds of semi-solid food materials(mayonnaise, tomato ketchup, and wasabi) have been measured over a wide range of shear rates and angular frequencies. The shear rate dependence of steady flow behavior and the angular frequency dependence of dynamic viscoelastic behavior were reported from the experimentally measured data. In addition, some viscoplastic flow models with a yield stress term were employed to make a quantitative evaluation of the steady flow behavior, and the applicability of these models was also examined in detail. Furthermore, the correlations between steady shear flow(nonlinear behavior) and dynamic viscoelastic(linear behavior)properties were discussed using the modified power-law flow equations. Main results obtained from this study can be summarized as follows : (1) Semi-solid food materials are regarded as viscoplastic fluids having a finite magnitude of yield stress, and their flow behavior shows shear-thinning characteristics, exhibiting a decrease in steady flow viscosity with increasing shear rate. (2) The Herschel-Bulkley, Mizrahi-Berk, and Heinz-Casson models are all applicable to describe the steady flow behavior of semi-solid food materials. Among these models, the Heinz-Casson model has the best validity. (3) Semi-solid food materials show a stronger shear-thinning behavior at shear rate region higher than a critical shear rate where a more progressive structure breakdown takes place. (4) Both the storage and loss moduli are increased with increasing angular frequency, but they have a slight dependence on angular frequency. The elastic behavior is dominant to the viscous behavior over a wide range of angular frequencies. (5) All of the steady flow, dynamic, and complex viscosities are well satisfied with the power-law model behavior. The relationships between steady shear flow and dynamic viscoelastic properties can well be described by the modified forms of the power-law flow equations.

  • PDF

GPR Development for Landmine Detection (지뢰탐지를 위한 GPR 시스템의 개발)

  • Sato, Motoyuki;Fujiwara, Jun;Feng, Xuan;Zhou, Zheng-Shu;Kobayashi, Takao
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.4
    • /
    • pp.270-279
    • /
    • 2005
  • Under the research project supported by Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT), we have conducted the development of GPR systems for landmine detection. Until 2005, we have finished development of two prototype GPR systems, namely ALIS (Advanced Landmine Imaging System) and SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar). ALIS is a novel landmine detection sensor system combined with a metal detector and GPR. This is a hand-held equipment, which has a sensor position tracking system, and can visualize the sensor output in real time. In order to achieve the sensor tracking system, ALIS needs only one CCD camera attached on the sensor handle. The CCD image is superimposed with the GPR and metal detector signal, and the detection and identification of buried targets is quite easy and reliable. Field evaluation test of ALIS was conducted in December 2004 in Afghanistan, and we demonstrated that it can detect buried antipersonnel landmines, and can also discriminate metal fragments from landmines. SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar) is a machine mounted sensor system composed of B GPR and a metal detector. The GPR employs an array antenna for advanced signal processing for better subsurface imaging. SAR-GPR combined with synthetic aperture radar algorithm, can suppress clutter and can image buried objects in strongly inhomogeneous material. SAR-GPR is a stepped frequency radar system, whose RF component is a newly developed compact vector network analyzers. The size of the system is 30cm x 30cm x 30 cm, composed from six Vivaldi antennas and three vector network analyzers. The weight of the system is 17 kg, and it can be mounted on a robotic arm on a small unmanned vehicle. The field test of this system was carried out in March 2005 in Japan.

Study on Safety Management Activity of Blood Test Room of Nuclear Medicine Department (핵의학과 혈액검사실의 안전 관리 활동에 대한 고찰)

  • Sim, Seong-Jae;Shin, Young-Kyun;Moon, Hyeong-Ho;Yoo, Seon-Hee;Jo, Shi-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.104-110
    • /
    • 2011
  • Purpose: The object evaluation method about medical institutes of these days increases credibility of consumers about medical services by conducting a certification system about medical institutes. In addition, as nuclear medicine test rooms and diagnosis test medicine room adopt many kinds of international certification systems, the matters regarding safety management of test rooms are being regarded as important. Since the blood test rooms of nuclear medicine are exposed to many harmful factors such as infection from clinical specimen and radioactive isotope reagent, there is a need to pay lots of attention to the safety management of staff and patients. Therefore, this study discusses safety management activities of staff and patients, which are conducted in the blood test rooms of the nuclear medicine department in Asan Medical Center. Materials and Methods: In the blood test rooms of the nuclear medicine department in Asan Medical Center, the matters regarding comprehensive safety management by the person in charge of safety management are offered and all staff members of the test rooms apply them into work. Safety management education is regularly conducted according to established regulations, and infection is prevented through implementation of wearing personal protectors and hand sanitation during test work. In addition, technical safety guides and accident guides for interruption of electric power are provided against emergencies. Through infection management guides, infection prevention and preparation methods for infection are learned and radioactive isotope management, safety management about reagent use and safety guides about harmful chemical substances are being applied to work. Results: The blood test rooms of the nuclear medicine department apply safety management regulations to work. Under the situation where hand sanitation should be conducted, hands are washed to prevent infection between staff and patients, and for preventing infection from clinical specimen, personal protectors are worn. The reagent, which is classified as harmful substance, is separately stored to be easily recognized, radioactive wastes and general medical wastes are also safely managed. Through these lots of safety management activities, safety management awareness of staff members is enhanced, and patients are protected from many dangers. Conclusion: Staff members of the blood test rooms of the nuclear medicine department should be fully aware of safety management regulations and apply them to work. When better safety management suggestions are made, they need to be examined and applied for increasing quality of safety management for staff and patients.

  • PDF

Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact (Metal artifact 감소를 위한 CT simulator 영상 재구성의 유용성 평가)

  • Choi, Ji Hun;Park, Jin Hong;Choi, Byung Don;Won, Hui Su;Chang, Nam Jun;Goo, Jang Hyun;Hong, Joo Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.191-197
    • /
    • 2014
  • Purpose : This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. Materials and Methods : By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, $15{\time}15cm2$ and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. Results : In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. Conclusion : The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.

Evaluation of superficial dose for Postmastectomy using several treatment techniques (유방전절제술을 시행한 환자에서 치료기법에 따른 피부선량 평가)

  • Song, Yong Min;Choi, Ji Min;Kim, Jin Man;Kwon, Dong Yeol;Kim, Jong Sik;Cho, Hyun Sang;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.225-232
    • /
    • 2014
  • Purpose : The purpose of this study was to evaluate the surface and superficial dose for patients requiring postmastectomy radiation therapy(PMRT) with different treatment techniques. Materials and Methods : Computed tomography images were acquired for the phantom(I'mRT, IBA) consisting of tissue equivalent material. Hypothetical chestwall and lung were outlined and modified. Five treatment techniques(Wedged Tangential; WT, 4-field IMRT, 7-field IMRT, TOMO DIRECT, TOMO HELICAL) were evaluated using only 6MV photon beam. GafChromic EBT3 film was used for dose measurements at the surface and superficial dose. Surface dose profiles around the phantom were obtained for each treatment technique. For superficial dose measurements, film were used inside the phantom and analyzed superficial region for depth from 1-6mm. Results : TOMO DIRECT showed the highest surface dose by 47~70% of prescribed dose, while 7-field IMRT showed the lowest by 35~46% of prescribed dose. For the WT, 4-field IMRT and 7-field IMRT, superficial dose were measured over 60%, 70%, and 80% for 1mm, 2mm, and 5mm depth, respectively. In case of TOMO DIRECT and TOMO HELICAL, over 75%, 80%, and 90% of prescribed dose was measured, respectively. Surface and superficial dose range were uniform in overall chestwall for the 7-field IMRT and TOMO HELICAL. In contrast, Because of the dose enhancement effect with oblique incidence, The dose was gradually increased toward the obliquely tangential angle for the WT and TOMO DIRECT. Conclusion : For PMRT, TOMO DIRECT and TOMO HELICAL deliver the higher surface and superficial doses than treatment techniques based linear accelerator. It showed adequate dose(over 75% of prescribed dose) at 1mm depth in skin region.

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Highly Doped Nano-crystal Embedded Polymorphous Silicon Thin Film Deposited by Using Neutral Beam Assisted CVD at Room Temperature

  • Jang, Jin-Nyeong;Lee, Dong-Hyeok;So, Hyeon-Uk;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.154-155
    • /
    • 2012
  • The promise of nano-crystalites (nc) as a technological material, for applications including display backplane, and solar cells, may ultimately depend on tailoring their behavior through doping and crystallinity. Impurities can strongly modify electronic and optical properties of bulk and nc semiconductors. Highly doped dopant also effect structural properties (both grain size, crystal fraction) of nc-Si thin film. As discussed in several literatures, P atoms or radicals have the tendency to reside on the surface of nc. The P-radical segregation on the nano-grain surfaces that called self-purification may reduce the possibility of new nucleation because of the five-coordination of P. In addition, the P doping levels of ${\sim}2{\times}10^{21}\;at/cm^3$ is the solubility limitation of P in Si; the solubility of nc thin film should be smaller. Therefore, the non-activated P tends to segregate on the grain boundaries and the surface of nc. These mechanisms could prevent new nucleation on the existing grain surface. Therefore, most researches shown that highly doped nc-thin film by using conventional PECVD deposition system tended to have low crystallinity, where the formation energy of nucleation should be higher than the nc surface in the intrinsic materials. If the deposition technology that can make highly doped and simultaneously highly crystallized nc at low temperature, it can lead processes of next generation flexible devices. Recently, we are developing a novel CVD technology with a neutral particle beam (NPB) source, named as neutral beam assisted CVD (NBaCVD), which controls the energy of incident neutral particles in the range of 1~300eV in order to enhance the atomic activation and crystalline of thin films at low temperatures. During the formation of the nc-/pm-Si thin films by the NBaCVD with various process conditions, NPB energy directly controlled by the reflector bias and effectively increased crystal fraction (~80%) by uniformly distributed nc grains with 3~10 nm size. In the case of phosphorous doped Si thin films, the doping efficiency also increased as increasing the reflector bias (i.e. increasing NPB energy). At 330V of reflector bias, activation energy of the doped nc-Si thin film reduced as low as 0.001 eV. This means dopants are fully occupied as substitutional site, even though the Si thin film has nano-sized grain structure. And activated dopant concentration is recorded as high as up to 1020 #/$cm^3$ at very low process temperature (< $80^{\circ}C$) process without any post annealing. Theoretical solubility for the higher dopant concentration in Si thin film for order of 1020 #/$cm^3$ can be done only high temperature process or post annealing over $650^{\circ}C$. In general, as decreasing the grain size, the dopant binding energy increases as ratio of 1 of diameter of grain and the dopant hardly be activated. The highly doped nc-Si thin film by low-temperature NBaCVD process had smaller average grain size under 10 nm (measured by GIWAXS, GISAXS and TEM analysis), but achieved very higher activation of phosphorous dopant; NB energy sufficiently transports its energy to doping and crystallization even though without supplying additional thermal energy. TEM image shows that incubation layer does not formed between nc-Si film and SiO2 under later and highly crystallized nc-Si film is constructed with uniformly distributed nano-grains in polymorphous tissues. The nucleation should be start at the first layer on the SiO2 later, but it hardly growth to be cone-shaped micro-size grains. The nc-grain evenly embedded pm-Si thin film can be formatted by competition of the nucleation and the crystal growing, which depend on the NPB energies. In the evaluation of the light soaking degradation of photoconductivity, while conventional intrinsic and n-type doped a-Si thin films appeared typical degradation of photoconductivity, all of the nc-Si thin films processed by the NBaCVD show only a few % of degradation of it. From FTIR and RAMAN spectra, the energetic hydrogen NB atoms passivate nano-grain boundaries during the NBaCVD process because of the high diffusivity and chemical potential of hydrogen atoms.

  • PDF

The Risk Factors Influencing the Postoperative Mortality of the Patients with an Abdominal Aortic Aneurysm (복부대동맥류 환자에서의 수술 후 사망의 위험인자 분석)

  • Lee, Seong-Kwang;Jun, Hee-Jae;Park, Kyung-Taek;Yoon, Young-Chul;Han, IL-Yong;Lee, Yang-Haeng;Cho, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.655-662
    • /
    • 2010
  • Background: Despite the rapid expansion of percutaneous endovascular repair, open surgical repair is still recognized as an option to achieve a cure. We retrospectively analyzed over a 6 year period the surgical outcomes, the complications and the mortality-related factors for patients with abdominal aortic aneurysms. Material and Method: We analyzed 36 patients who underwent surgery for abdominal aortic aneurysms between May 2001 and June 2005, and between April 2007 and November 2009. The indications for surgery were rupture, a maximal aortic diameter > 50 mm, and medically intractable hypertension or pain. Result: The mean patient age was $69.67{\pm}6.97$ years (range: 57 to 84 years). Thirty two patients (88.9%) were males and 4 patients (11.1%) were females. Extension to the iliac artery existed in 28 patients (77.8%). Thirteen patients (36.1%) had ruptured aortic aneurysms. The mean maximal diameter of the aorta was $73.7{\pm}13.3$ mm (60 to 100 mm). Surgery was performed by a midline laparotomy and 10 patients (27.8%) underwent emergency surgery. The mortality rate was 8.3%; the mortality rate for the patients with ruptured aneurysms was 23.1 % and the mortality rate for patients with unruptured aneurysms was 0%. The postoperative complications included wound infection (3 cases), sepsis (2 cases), renal failure (2 cases) and pneumonia (1 case). Unstable vital signs, pre-operative transfusion, ruptured aneurysm, emergency surgery, comorbidity (DM and syncope) and complications (sepsis and renal failure) were the statistically significant mortality-related factors (p < 0.05). Conclusion: Emergency surgery for ruptured aortic aneurysms continues to have high mortality, but the unruptured cases are repaired with relative safety. Even though endovascular aortic repair is the trend for abdominal aortic aneurysms, an elective operation of the unruptured aneurysms could decrease the procedure's morbidity and the inconvenient for repeat evaluation with good surgical results.