• 제목/요약/키워드: material evaluation

검색결과 5,343건 처리시간 0.032초

추진장치의 고장진단과 성능특성에 관한 연구 (A Study on Fault Diagnosis and Performance Evaluation of Propulsion Equipment)

  • 한영재
    • 한국전기전자재료학회논문지
    • /
    • 제18권2호
    • /
    • pp.153-158
    • /
    • 2005
  • Recently, as the feasibility study shows that trans-Korea railway and trans-continental railway are advantageous, interest in high-speed railway system is increasing. Because railway vehicle is environment-friendly and safe compared with airplane and ship, its market-sharing increases gradually. KHST(Korean High Speed Train) has been developed by KRRI (Korea Railroad Research Institute) for last 6 years to satisfy the need. An electric railway system is composed of high-tech subsystems, among which main electric equipment such as transformers and converter are critical components determining the performance of rolling stock. We developed a measurement system for on-line test and evaluation of performances of KHST. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A now method to measure temperature was applied to the measurement system. By using the system, fault diagnosis and performance evaluation of electric equipment in Korean High Speed Train was conducted during test running.

멤브레인 방수층 성능 및 평가방법에 관한 기초적 연구 (A Basic Study on Evaluation Method and Performance of Membrane Waterproofing Layer)

  • 오미현;권시원;강효진;정희원;최인성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.17-21
    • /
    • 2003
  • This study is mainly acceptive for physical material performance than waterproofing layer performance on the external condition after construction. The reason are legalized only for material performance duality standard even though it is existed waterproofing materials for membrane. In actuality, waterproofing layer are greatly occurred in performance a decreased developing essential element that are human footprints as a result physical perimeter environment after construction and on the construction. As the result, this present paper purpose for evaluation and performance of the membrane waterproofing layer on the construction.

  • PDF

RADIATION SHIELDING EVALUATION OF IP-2 PACKAGES FOR LOW- AND INTERMEDIATE-LEVEL RADIOACTIVE WASTE

  • Kim, Min-Chul;Choi, Jong-Rak;Chung, Sung-Hwan;Ko, Jae-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.511-516
    • /
    • 2008
  • Korea Hydro & Nuclear Power Co., Ltd. (KHNP) developed new IP-2 packages to transport low- and intermediate-level radioactive waste (LILW) steel drums from nuclear power plants to a disposal facility in accordance with IAEA and Korean transport regulations of radioactive material. Radiation shielding evaluation of the packages was carried out to demonstrate compliance with the regulatory requirements for IP-2 packages of radioactive material. Dose rate limits of LILW drums contained in the packages were determined.

초소형 금형소재의 기계적 특성평가 (Mechanical Characteristic Evaluation of Proper Material for Ultra-fine Dies)

  • 강재훈;이현용;이낙규
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.473-476
    • /
    • 2005
  • Today's manufacturing industry is facing challenges from advanced difficult-to-machine materials (WC-Co alloys, ceramics, and composites), stringent design requirements (high precision, complex shapes, and high surface quality), and machining costs. Advanced materials play an increasingly important role in modem manufacturing industries, especially, in aircraft, automobile, tool, die and mold making industries. The greatly-improved thermal, chemical, and mechanical properties of the material (such as improved strength, heat resistance, wear resistance, and corrosion resistance), while having yielded enormous economic benefits to manufacturing industries through improved product performance and product design, are making traditional machining processes unable to machine them or unable to machine them economically. In this paper, mechanical characteristic evaluation test of fine powder type WC-Co alloy was accomplished to obtain clear data for miniaturized special die parts machining with high reliability and high quality.

  • PDF

등가 물성 평가를 이용한 골판지의 물성치 (The Mechanical Properties of Corrugated Cardboard using Equivalent Evaluation)

  • 권경영;정종윤
    • 산업경영시스템학회지
    • /
    • 제37권1호
    • /
    • pp.157-164
    • /
    • 2014
  • The usage of corrugated cardboard for packing material is increasing in these days because it is light and easy to manufacture packing boxes. However, the structure analysis of packing boxes, made of cardboard, is not well carried. The reason can be deduced that its mechanical properties for structure analysis are not well known. The cardboards are made different shapes with various types of raw materials that are paper-based compound. In addition, the cardboards are considered to be orthotropic material. This research finds mechanical properties of triple layered cardboard which is composed of outer liner and inner liner. The moduli of elasticity and of shear for liners are found from tension test and T-Peel test. The mechanical properties of the cardboard are calculated using the super position method and equivalent evaluation method.

Axle Housing의 내구성 판단과 피로특성 (Endurance Evaluation and Fatigue Property fo Axle Housing)

  • 변희문;이순복
    • 한국기계연구소 소보
    • /
    • 통권13호
    • /
    • pp.3-13
    • /
    • 1984
  • Fatigue failure of axle housing could cause many injuries and much financial loss. This challenges the engineer to improve design decisions involving fatigue. Endurance evaluation of axle housing is great interest to auto-mobile manufacturers for the sake of safety and reliability. Axle housing is subjected to gross vehicle weight(G.V.W)as mean load and alternating load. Theoretical design diagram involving mean and alternating stresses is used for the evaluation of axle housing fatigue endurance with the equivalent stress of fatigue critical area on the axle housing. Four point bending fatigue tests on axle housing with constant amplitude loading at approximately R=0 were performed with 50 ton servohydraulic strucural fatigue testing machine developed at KIMM. Specimens were made with the same material STKM 13B as the axle housing and tested to obtain S_N data. Five specimens of STKM 13B were tested at 253.61 MPa and weibull distribution was obtained at the same stress level. Material data and structural data were compares and fatigue stress property factor and fatigue life property factor were obtained.

  • PDF

외부조건의 변화에 따른 섬유보강콘크리트의 내구성능 정가에 관한 연구 (A Study on the Evaluation of Durability of Fiber Reinforced Concrete According to the Change of External Conditions)

  • 김남욱
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.97-104
    • /
    • 2008
  • This study was intended to evaluate the permeable performance through a change of reinforcing materials, curing condition, durability evaluation and permeability test, and to select the reinforcing material which could reduce the durability and water tightness from it, as the study for considering how the change of the outside's environment factors that the concrete structure actually contacted with impacted the concrete's durability especially the permeability by referring to such the background of the study. Accordingly, it was judged that evaluating the permeability by considering the severe environment condition where the concrete structure was placed in was more reasonable than measuring the existing permeability coefficient conducted in the sound state for the permeability evaluation of actually-used concrete structure. In this study, it also could be known that the specimen of hybrid fiber reinforced concrete which mixed the long and short steel fiber was the most effective for water tightness enhancement in severe environmental conditions.

HVDC 케이블 평가방법 연구 (Study on the Evaluation Methode of HVDC Cable)

  • 안용호;장태인;정길조;유희영;김정년;전승익;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.229-231
    • /
    • 2005
  • HVDC(High Voltage Direct Current) is an underwater cable between Jeju Island and Haenam in main land and supplies approximately 50% of electrical usage in Jeju Island. If there is any power failure due to HVDC, it will cost approximately 50,000 US dollars per day including Thermal Electrical Generation. Therefore it is absolutely necessary to recover the problem in rapid timely basis. In conclusion, evaluation methode of HVDC cable is needed urgently to upgrade current HVDC underwater cable repair technique in Korea to minimize the cost and time factors.

  • PDF

치기공과 임상실습 평가항목의 내용구성과 배점에 관한 연구 - 재학생 중심으로 - (A Study on Content Organization and Assigning Score of Evaluation Elements of Clinical Practice of Dept. of Dental Technology - Centering on the undergraduates -)

  • 이화식;배봉진;박명호
    • 대한치과기공학회지
    • /
    • 제30권1호
    • /
    • pp.73-82
    • /
    • 2008
  • This study has been analyzed to write an ideal training evaluation table after analyzing validity of content organization and assigning score of evaluating elements of clinical practice of Dept. of dental technology. 220 junior students who are studying dental technology in D university in Daegu were questioned to analyze the relationship of content organization and score of clinical practice evaluation table. The corrected material has been inspected by SAS V8 for Windows. The results are as following. 1. The validity of content organization of clinical practice evaluation table has a result which can be reliable over than 70% but the validity of score shows low reliance. c 2. The validity of content organization of detail elements of clinical practice evaluation shows that overuse of material and attentiveness(3.78) and responsibility (3.60) are high response but in score organization, the validity shows that safety measure(2.36) when controling machines, arrangement(2.98) after use and ability (2.98) of solving problems are very low. 3. In the elements without interpersonal relation, it shows that those are related to each other. its grading is p < 0.01 so it appears to be meaningful. 4. In result of analyzing the effect to 'studying amount' mark in clinical practice evaluation mark, it appears the element of attitude for job to affect it. And in result of analyzing the effect to 'training attitude' mark, it appears the element of 'controling machines' to affect it. For these results, to be a better evaluation tool, it should be modified by continuous research with arranging evaluation elements to be marked differently in between elements.

  • PDF

가스터빈 로터 재질에 따른 표면결함 와전류 특성연구 (The Study on Eddy Current Characteristic for Surface Defect of Gas Turbine Rotor Material)

  • 안연식;길두송;박상기
    • 동력기계공학회지
    • /
    • 제14권4호
    • /
    • pp.63-67
    • /
    • 2010
  • This paper introduces the eddy current signal characteristic of magnetic and non-magnetic gas turbine rotor. In the past, Magnetic particle inspection method was used in magnetic material for qualitative defect evaluation and the ultrasonic test method was used for quantitative evaluation. Nowadays, eddy current method is used in magnetic gas turbine rotor inspection due to advanced sensor design technology. We are studying on the magnetic gas turbine rotor by using eddy current method. We prepared diverse depth specimens made by magnetic and non-magnetic materials. We select optimum frequency according to material standard penetration data and experiment results. We got the signal on magnetic and non-magnetic material about 0.2 mm, 05 mm, 1.0 mm, 1.5 mm 2.0 mm and 2.5 mm depth defects and compare the signal amplitude and signal trend according to defect depth and frequency. The results show that signal amplitudes of magnetic are bigger than non-magnetic material and the trends are similar on every defect depth and frequency. The detection and resolution capabilities of eddy current are more effective in magnetic material than in non-magnetic materials. So, the eddy current method is effective inspection method on magnetic gas turbine rotor. And it has the merits of time saving and simple procedure by elimination of the ultrasonic inspection in traditional inspection method.