Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: An integrative review

  • Terrabuio, Bianca Rodrigues;Carvalho, Caroline Gomes;Peralta-Mamani, Mariela;da Silva Santos, Paulo Sergio;Rubira-Bullen, Izabel Regina Fischer;Rubira, Cassia Maria Fischer
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.93-106
    • /
    • 2021
  • Purpose: This study was conducted to review the literature regarding the types of cone-beam computed tomography (CBCT) artifacts around dental implants and the factors that influence their formation. Materials and Methods: A search strategy was carried out in the PubMed, Embase, and Scopus databases to identify published between 2010 and 2020, and 9 studies were selected. The implants included 306 titanium, titanium-zirconium, and zirconia implants, as well as 5 titanium cylinders. Results: The artifacts around the implants were the beam-hardening artifact, the streaking artifact, and band-like radiolucent areas. Some factors that influenced the formation of artifacts were the implant material, bone type, evaluated regions, distance, type of CBCT, field of view (FOV) size, milliamperage, peak kilovoltage (kVp), and voxel size. The beam-hardening artifact was the most widely reported, and it was minimized in protocols with a smaller FOV, larger voxels, and higher kVp. Conclusion: The risk and benefit of these protocols in individuals with dental implants must be considered, and clinical examinations and complementary radiographs play an essential role in implantology.

토모테라피에서 반복적 금속 인공물 감소 알고리즘의 유용성 평가: 팬톰 실험 (Effect of Iterative-metal Artifact Reduction (iMAR) at Tomotherapy: a Phantom Study)

  • 김대건;정재홍;김성철
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.709-718
    • /
    • 2022
  • 본 연구의 목적은 토모테라피 방사선치료에서 고밀도 알루미늄, 티타늄, 강철 금속 삽입물에 대한 단층촬영(CT)을 평가하고 자 하였다. 다양한 밀도의 원통형 막대를 포함한 금속 삽입물과 함께 원통형 토모팬텀을 이용하여 영상을 얻었다. 총 세 가지의 CT 영상에 대해 평균 CT 값(number)와 표준 편차를 구하고, 치료계획 선량평가도 수행하였다. 고밀도 금속 삽입물이 CT값과 변화가 가장 컸다. 타겟에 대한 선량평가(적합성 지수, CI)에서 반복적 금속 인공물 감소 알고리즘(iMAR)이 적용된 영상이 그렇지 않은 영상에 비해 약 20% 좋았으나 유의한 차이는 없었다. iMAR은 표적 및 장기의 묘사에 도움을 주고 토모테라피를 이용한 3차원 입체조형 방사선치료기술(3D-CRT)에서 불확실성을 줄이는 데 도움이 될 것으로 사료된다.

PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰 (The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT)

  • 박민수;함준철;조용인;강천구;박훈희;임한상;이창호
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.35-43
    • /
    • 2012
  • CT를 기반으로 감쇠 보정이 시행되는 PET/CT 검사에서는 금속 삽입물에 의한 선속 경화 현상 (Beam Hardening Artifact)으로 인공물이 발생 된다. 이는 인접한 부위의 과대 혹은 과소 평가를 유발하는 감쇠 보정으로 인해 $^{18}F$-FDG의 섭취 변화를 가져오며 영상의 질과 비뇨 생식기 질환의 진단능을 저하시킨다. 따라서 본 연구에서는 PET/CT 영상의 질 향상을 위한 금속 인공물 저감 (Metal Artifact Reduction, MAR) algorithm 재구성방법의 유용성을 평가하고자 한다. 인공 고관절 삽입물에 대한 인공물을 평가하기 위해 SPECT/PET Phantom에 고관절 삽입물을 고정 하여 PET/CT를 진행했다. W/O MAR algorithm 영상과 MAR algorithm 영상에서 CT상에 나타나는 Bright streak, Dark streak, Metal과 Background의 영역에서의 표준화 섭취 계수(Standardized Uptake Value)의 변화를 분석하였다. 또한 본원에 내원한 고관절 전치환술을 시행한 15명의 환자에게서 W/O MAR algorithm과 MAR algorithm, 비 감쇠 보정 영상을 비교 평가하였다. W/O MAR algorithm 영상에서 SUV는 Bright streak 영역에서는 $0.98{\pm}0.48$ g/ml, Dark streak 영역에서는 $0.88{\pm}0.02$ g/ml, Metal 영역에는 $0.24{\pm}0.16$ g/ml, Background 영역은 $0.91{\pm}0.18$ g/ml로 측정되었다. 하지만 MAR algorithm 영상에서는 Bright streak 영역에서는 $0.88{\pm}0.49$ g/ml, Dark streak 영역은 $0.63{\pm}0.21$ g/ml, Metal 영역에서는 $0.06{\pm}0.07$ g/ml, Background는 $0.90{\pm}0.02$ g/ml로 측정되었다. MAR algorithm 적용 시 SUV가 평균적으로 감소 하였으며, W/O MAR algorithm 영상에서는 Bright streak영역에서 Background 보다 높게 측정되어 false positive uptake로 나타났으나 MAR algorithm 영상에서는 Background와 비슷한 농도와 SUV가 나타났고, false positive uptake가 관찰되지 않았다. 따라서 MAR algorithm을 적용하여 인공 고관절 삽입물 주변 조직의 과대 혹은 과소 감쇠 보정으로 인한 섭취의 증가를 줄일 수 있었다. 하지만 Dark streak 영역에서의 SUV 저하를 줄이기 위한 방안은 더욱 많은 연구가 이뤄져야 할 것이다. 고관절 삽입 인공물로 인해 발생하는 Bright streak 영역에서의 false positive uptake를 감소시키고 이와 인접해 있는 비뇨 생식기 질환에 W/O MAR algorithm과 MAR algorithm, 비 감쇠 보정 영상이 동시에 제공된다면 더욱 진단능을 향상 시킬 수 있으리라 생각된다.

  • PDF

자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과) (Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect))

  • 최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.335-341
    • /
    • 2018
  • 의료수준의 향상과 더불어 환자들의 첨단의료장비에 대한 기대수준이 증가하고 있으며 특히 자기공명영상(Magnetic Resonance Image : MRI)은 현재 모든 임상 분야에서 가장 핵심적인 영상진단 도구로서 사용되고 있다. 그러나 검사 중에 발생하는 심각한 소음으로 많은 환자가 심리적인 불안을 경험한다고 한다. 이에 본 연구에서는 자기공명영상검사실의 기존 헤드셋 흡음재에서 차음재를 추가한 헤드셋의 소음저감평가와 차음재별 영상 아티팩트(artifact) 유무를 알아보고자 하였다. 3D 프린팅한 헤드셋 내부에 흡음재(스펀지)와 차음재(아크릴판, 구리판, 3D copper plate)를 교차 배열하여 MRI 검사소음을 녹음하여 스피커로 같은 dB 값의 소음을 발생시키며 3D 프린팅 된 두부모형의 내부에 소음측정기로 dB 값을 측정하여 정량분석을 하며 자체 제작한 헤드셋을 물팬텀에 밀착시킨 후 MRI영상 아티팩트 유무를 검사한다. 드셋의 정량평가를 한 결과, 헤드셋 평균 dB 값은 81.8 dB로 나타났으며, 차음재를 추가한 헤드셋에서 가장 방음효과가 뛰어난 재료조합(구리, 아크릴판, 스펀지, 스펀지) 헤드셋의 평균 dB 값은 70.4 dB 값이 측정되었지만 MRI 시뮬레이션 결과 구리가 반자성체이기 때문에 아티팩트가 나타나 배제하였고 두 번째로 방음효과가 뛰어난 (스펀지, 아크릴판, e-copper plate, 스펀지) 헤드셋의 평균 dB 값은 70.6 dB 값이 측정되었고 MRI 시뮬레이션 결과 인공물 나타나지 않았다. 구리분말이 약 40%가 포함된 e-copper PLA로 출력한 재료를 동일하게 시뮬레이션을 한 결과 인공물 나타나지 않았으므로 3D 프린팅 재료의 사용이 적합하였고 구리보다 경제성이 우수하며 가공이 용이하므로 적합한 재료로 선정하였다. MRI관련 연구에 있어 3D 프린팅을 이용한 상호발전이 매우 기대된다.

일상 디자인산물의 구성배치 전략과 맥락에 관한 연구 - 창조성템플릿이론과 산물맥락모델을 이용한 분석을 중심으로 - (A Case Study of Configuration Strategy and Context in Everyday Artifacts - Concentrated on analysis by Creativity Template Theory and Artifact Context Model -)

  • 진선태
    • 디자인학연구
    • /
    • 제19권4호
    • /
    • pp.41-50
    • /
    • 2006
  • 후기산업사회에서 기업내 디자인팀, 디자이너컨설턴시에 의해 디자인된 제품이 생산되고 유통되는 것이 일반적인 디자인체제이다. 과거 전통 사회의 버내큐러 디자인(Vernacular Design)같은 디자인체제 또한 오늘날 시대적 요구에 맞게 변형되어 인간의 물질환경을 형성하는 디자인문화로 남아 있다. 기성디자인과 다른 우리 주변의 다양한 디자인산물들은 사용자에 의한 변용, 일상영역에서의 생산물 등의 사례로 발견되고 있다. 본 연구에서는 이러한 사례를 가지고 비전문적 디자인생산물의 구성품배치의 변화와 산물의 발생상황등의 맥락을 보기 위해 창조성템플릿이론과 산물맥락모델(ACM:Artifact Context Model)을 이용해 분석하였다. 이 연구를 통해 비전문영역에서 보이는 일상 디자인산물들은 일상디자인주체, 사용자가 만들어 내는 평범하지만 나름대로 아이디어와 특이성이 드러나는 산물이며, 이러한 특성들은 기성디자인영역에 새로운 창조적 모티브가 되거나 기성적 디자인영역을 보완하는 하나의 디자인체계의 가능성을 찾을 수 있었다. 기존 디자인에서 볼 수 없는 다양한 모색과 대안이 만들어지는 일상디자인영역은 기업의 제품기획과 마케팅의 한계와는 다른 디자인실천의 영역이다. 또한 신뢰성있는 소비자, 사용자 모델링은 사용자 친화적 디자인, 사용자 커스터마이제이션 구현에 쉬운 접근이 될 수 있다. 향 후 연구에서는 본 연구의 탐색적 디자인과정에 대한 해석과 일상적 디자인산물 분석을 바탕으로 일상디자이너에 대한 중점적인 인지적 프로세스 모델링 등을 통해 기존디자인프로세스 및 디자인교육에 대한 새로운 접근 가능성을 모색할 수 있을 것이다.이미지의 상징적 이미지를 형상화한다. 코리아 이미지를 이용한 형상화 연구는 한국의 정체성을 명확하게 하며, 도시환경을 구성하는 물리적인 요소에 의한 사용자의 행태적인 변화뿐만 아니라 한국의 문화적 가치향상에도 많은 영향을 주리라 본다.제시하고자 한다.이는 소형 모바일 정보기기의 텍스트 레이아웃 디자인에 충분히 활용 가능할 것으로 기대된다.강조하고 있으나 친환경성이 입증되지 않은 제품에 대해서도 친환경 소재임을 내세워 소비자의 판단을 흐리는 경우가 많으므로 이에 대한 시정이 필요하다.칼리를 시용한 구보다 유의하게 높았는데(p<0.05), 이러한 경향은 이른 봄에 액상구비를 시용한 구에서 더욱 뚜렷하였다. 불과하였고 설명 후 이의 필요성에 대하여 묻는 질문에는 135명(71.4%)이 필요하다고 하였으며 동의서의 길이가 길어진다면 스스로 읽겠다(30명, 15.9%)기보다는 84.1%가 구두설명의 필요성을 요구하고 있었다. 임상시험시 발생하는 부작용 또는 문제점의 발생시 의사나 회사에 책임을 묻겠다는 대답이 76명(40.2%)으로 이 중 17명(9.0%)은 시비를 가리지 않고 무조건 책임을 묻겠다고 하였다. 결 론 : 본 설문조사는 임상시험과 피험자 동의서에 대한 가장 기초적인 설문 조사로 대상인 암환자와 가족들이 비교적 정확하고 긍정적인 견해를 가지고 있었으나 임상시험과 피험자 동의서에 대한 보다 적극적인 홍보와 교육이 필요하며 피험자동의서의 간편성과 이해력의 향상에 대한 연구가 요구됨을 보여주었다. 논평하였음을 퇴계는 '완세불공(玩迷不恭)'이라고 판단했을 것이다. 장육당은 청(淸)과 탁(濁)이 있음을 알지 못하고. 그것의 분별도

  • PDF

Effect of Manganese Content on the Magnetic Susceptibility of Ferrous-Manganese Alloys: Correlation between Microstructure on X-Ray Diffraction and Size of the Low-Intensity Area on MRI

  • Youn, Sung Won;Kim, Moon Jung;Yi, Seounghoon;Ahn, Hyun Jin;Park, Kwan Kyu;Lee, Jongmin;Lee, Young-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.76-87
    • /
    • 2015
  • Purpose: There is an ongoing search for a stent material that produces a reduced susceptibility artifact. This study evaluated the effect of manganese (Mn) content on the MRI susceptibility artifact of ferrous-manganese (Fe-Mn) alloys, and investigated the correlation between MRI findings and measurements of Fe-Mn microstructure on X-ray diffraction (XRD). Materials and Methods: Fe-Mn binary alloys were prepared with Mn contents varying from 10% to 35% by weight (i.e., 10%, 15%, 20%, 25%, 30%, and 35%; designated as Fe-10Mn, Fe-15Mn, Fe-20Mn, Fe-25Mn, Fe-30Mn, and Fe-35Mn, respectively), and their microstructure was evaluated using XRD. Three-dimensional spoiled gradient echo sequences of cylindrical specimens were obtained in parallel and perpendicular to the static magnetic field (B0). In addition, T1-weighted spin echo, T2-weighted fast spin echo, and $T2^*$weighted gradient echo images were obtained. The size of the low-intensity area on MRI was measured for each of the Fe-Mn binary alloys prepared. Results: Three phases of ${\alpha}^{\prime}$-martensite, ${\gamma}$-austenite, and ${\varepsilon}$-martensite were seen on XRD, and their composition changed from ${\alpha}^{\prime}$-martensite to ${\gamma}$-austenite and/or ${\varepsilon}$-martensite, with increasing Mn content. The Fe-10Mn and Fe-15Mn specimens comprised ${\alpha}^{\prime}$-martensite, the Fe-20Mn and Fe-25Mn specimens comprised ${\gamma}+{\varepsilon}$ phases, and the Fe-30Mn and Fe-35Mn specimens exhibited a single ${\gamma}$ phase. The size of the low-intensity areas of Fe-Mn on MRI decreased relative to its microstructure on XRD with increasing Mn content. Conclusion: Based on these findings, proper conditioning of the Mn content in Fe-Mn alloys will improve its visibility on MR angiography, and a Mn content of more than 25% is recommended to reduce the magnetic susceptibility artifacts on MRI. A reduced artifact of Fe-Mn alloys on MRI is closely related to the paramagnetic constitution of ${\gamma}$-austenite and/or ${\varepsilon}$-martensite.

천목다완(天目茶盌)의 복원과 유약분석 - 신복원재료의 적용 - (Conservation and Chemical Composition of Temmku bowl with hare's fur markings - Applying new restoration material -)

  • 황현성;이해순;강형태
    • 박물관보존과학
    • /
    • 제7권
    • /
    • pp.33-42
    • /
    • 2006
  • 국립중앙박물관 보존과학실은 소장품의 유물상태에 따라 보존처리 우선순위 등급을 작성하였고, 2006년부터 연차적인 보존처리를 수행해오고 있다. 본 논문은 그 중 천목다완(신도1961)의 결손된 부분을 새로이 개발한 신복원재료를 사용하여 복원하는 과정을 소개하고 일부 박락된 유약층은 LIBS와 SEM-EDS분석기기를 사용하여 천목다완의 독특한 문양을 나타내는 유약성분을 분석하였다.

1890년${\sim}$1960년대 여자 저고리 감정 (The Appraisal of Female Jackets from the Period of $1890s{\sim}1960s$)

  • 최은수
    • 복식
    • /
    • 제58권5호
    • /
    • pp.178-197
    • /
    • 2008
  • Due to the inflow of the western culture since the 19th century, female skirts and jackets have been changed considerably in detail though their basic composition was maintained. The analysis on female jackets from the start of the modern period to 1960s has been undertaken with artefacts as well as reports and research dissertations related to them. For period appraisal, analysis was divided into several periods which are from 1890s to 1910s, and every 10 years afterwards. As a result, aspects for the appraisal in each period was found. Aspects for period appraisal in modern jackets can be a change in total length and side length, a change in shape of the sleeves (from straight to round), a change in width, and a difference in closed shape of the collars. Material and color can be another aspect which shows fashionable material or new materials (man-made textile or nylon) of each period, color combination of surface and lining material as well as other parts of the jacket, use of a stiffener made with net or sheer textiles. Research using books and archives is important for the appraisal of the garment artifact. However, most of all, one should have the attitude of examining the artifacts frequently in order to achieve deeper understanding and an eye for accurate appraisal.

Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters

  • Rabelo, Katharina Alves;Cavalcanti, Yuri Wanderley;de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Campos, Paulo Sergio Flores;de Andrade Freitas Oliveira, Luciana Soares;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.189-197
    • /
    • 2017
  • Purpose: To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters. Materials and Methods: Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at P<.05. Results: There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines (P<.05). Fiberglass posts did not differ statistically from the control group in terms of hypodense halos(P>.05). Conclusion: Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.

높은 자장하에서 자기공명 영상 왜곡이 완화된 생체용 Ti 복합재료 (Bio-applicable Ti-based Composites with Reduced Image Distortion Under High Magnetic Field)

  • 김성철;김유찬;석현광;양석조;손인진;이강식;이재철
    • 대한금속재료학회지
    • /
    • 제50권5호
    • /
    • pp.401-406
    • /
    • 2012
  • When viewed using a magnetic resonance imaging (MRI) system, invasive materials inside the human body, in many cases, severely distort the MR image of human tissues. The degree of the MR image distortion increases in proportion not only to the difference in the susceptibility between the invasive material and the human tissue, but also to the intensity of the magnetic field induced by the MRI system. In this study, by blending paramagnetic Ti particles with diamagnetic graphite, we synthesized $Ti_{100-x}C_x$ composites that can reduce the artifact in the MR image under the high-strength magnetic field. Of the developed composites, $Ti_{70}C_{30}$ showed the magnetic susceptibility of ${\chi}=67.6{\times}10^{-6}$, which corresponds to 30% of those of commercially available Ti alloys, the lowest reported in the literature. The level of the MR image distortion in the vicinity of the $Ti_{70}C_{30}$ composite insert was nearly negligible even under the high magnetic field of 4.7 T. In this paper, we reported on a methodology of designing new structural materials for bio-applications, their synthesis, experimental confirmation and measurement of MR images.