• Title/Summary/Keyword: mass size

Search Result 2,510, Processing Time 0.032 seconds

Rigorous Model for Spherical Cell-support Aggregate

  • Moon, Seung-Hyeon;Lee, Ki-Beom;Satish J. Paruekar
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.1
    • /
    • pp.42-50
    • /
    • 2001
  • The activity of immobilized cell-support particle aggregates is influenced by physical and biochemical elements, mass transfer, and physiology. Accordingly, the mathematical model discussed in this study is capable of predicting the steady state and transient concentration profiles of the cell mass and substrate, plus the effects of the substrate and product inhibition in an immobilized cell-support aggregate. The overall mathematical model is comprised of material balance equations for the cell mass, major carbon source, dissolved oxygen, and non-biomass products in a bulk suspension along with a single particle model. A smaller bead size and higher substrate concentration at the surface of the particle, resulted in a higher supply of the substrate into the aggregate and consequently a higher biocatalyst activity.

  • PDF

Effect of Particle Characteristics and Temperature on Shear Yield Stress of Magnetorheological Fluid

  • Wu, Xiangfan;Xiao, Xingming;Tian, Zuzhi;Chen, Fei;Jian, Wang
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.244-248
    • /
    • 2016
  • Aiming to improve the shear yield stress of magnetorheological fluid, magnetorheological fluids with different particle characteristics are prepared, and the influence rules of particle mass fraction, particle size, nanoparticles content and application temperature on shear yield stress are investigated. Experimental results indicate that shear yield stress increases approximate linearly with the enhancement of particle mass fraction. Particle size and the nanoparticles within 10% mass fraction can improve the shear yield stress effectively. When the application temperature is higher than $100^{\circ}C$, the shear yield stress decreases rapidly because of thermal expansion and thermal magnetization effect.

A Study on Mass Reduction in the Conceptual Design of Solar Array with Commercial Solar Cells for Small SAR Satellites (상용 태양전지 셀을 이용한 소형 SAR 위성의 태양전지 어레이 개념설계 및 경량화 연구)

  • Kim, Tae-Deuk
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.5
    • /
    • pp.49-63
    • /
    • 2017
  • Solar cells have widely been utilized for a satellite to convert sunlight energy into electricity in space. Many different types of solar cells appropriate for each satellite program are available in current markets, which enables us to construct a solar array light and small often required from a low Earth orbit (LEO) synthetic aperture radar (SAR) satellite. Thus, it is important to choose a proper solar cell satisfying the requirements of mass and size for the solar array. In this article, we have surveyed typical suppliers and have discussed some characteristics of solar cells. Conceptual design examples of the solar array for LEO SAR satellites using several types of solar cells have been performed to show the pros and cons of solar cells by comparison of the total mass and size necessary for the solar array.

Histopathological Changes of Subcutaneous Exposure to Glass Fibers in Rats (흰쥐에서 유리섬유의 피하삽입에 의한 경시적 병리조직학적 변화)

  • Lee, Min-Jae;Cho, Soo-Hun;Jang, Ja-June
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.69-76
    • /
    • 1997
  • To exanime in vivo tissue reactions of glass fibers, we injected glass fibers to rats subcutaneously. We made fibers of average dimensions of approximately $2{\mu}m$ in diameter and $60{\mu}m$ in length. After instilation of glass fiber we sacrificed rats sequentially at 1, 3 and 6 months. At 1 month after injection of glass fibers, the exposure area turned to yellow color and formed well-demarcated round mass. The average size of the mass was $1\times0.3cm$. Grossly detectable mass was decreased in size at 6 months compared to 1 or 3 months. Microscopically, strong foreign body reaction to glass fibers, inflammation and fibrosis were observed until 6 months. Foreign body reaction was increased up to 3 months, but it was decreased after 6 months. In scanning electron microscope, there was many bundles of glass fibers around the inflammation area, but the size of glass fibers were gradually reduced from 1 month to 6 months. These results suggest that subcutaneous exposure of glass fiber can provoke strong tissue reaction including foreign body granulomas, inflammation and fibrosis. But glass fiber itself did not produce any neoplastic changes.

  • PDF

Size Distributions of Atmospheric Particles in Cheonan, Korea

  • Oh, Se-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.45-48
    • /
    • 2006
  • Mass size distributions of atmospheric particles in Cheonan were determined using a high volume air sampler equipped with a 5-stage cascade impactor. Bimodal distributions that are typical for urban atmospheric particles were obtained. A MMD of the fine particle mode was $0.47{\pm}0.05{\mu}m$ with a GSD of $2.72{\pm}0.21$, and those of the coarse particles were $5.15{\pm}0.18{\mu}m\;and\;2.09{\pm}0.09$, respectively. The annual average concentrations of TSP, PM10, PM2.5, and PM1 were 74.1, 67.5, 54.2, and $42.3{\mu}g/m^3$, respectively. Although the daily PM10 concentrations were under the current National Standard, the daily PM2.5 concentrations frequently exceeded the US Standard even in non asian dust periods. The fractions of PM 10, PM2.5, and PM1 in TSP were $0.905{\pm}0.013,\;0.723{\pm}0.022,\;and\;0.572{\pm}0.029$, respectively, and fine mode particles occupied $57{\sim}72%$ of the total particle mass. The results indicate that fine particles were at the concerning level, and should be the target pollutant for the regional air quality strategy in Cheonan.

A study on Characteristics of Airborne Dusts in Seoul Subway Stations (서울 지하철 내 공기 중 먼지의 특성에 관한 연구)

  • 김진경;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.154-160
    • /
    • 2004
  • The purpose of this study was to evaluate airborne concentrations and characteristics of TSP, IPM, TPM and RPM in Seoul subway stations. Sampling was performed at 14 stations from April 11 to 29, 2002. Size-selective dust concentrations and metal concentrations were measured by gravimetric method and ICP-AES, respectively. The geometric mean of TSP, IPM, TPM and RPM concentrations in Seoul subway stations were 176$\mu\textrm{g}$/㎥, 348$\mu\textrm{g}$/㎥, 158$\mu\textrm{g}$/㎥ and 104$\mu\textrm{g}$/㎥, respectively. Dust concentrations in pathway were the highest and those in lobby were the lowest. The size distribution of dusts was significantly different by location of collection. When the deposition rate into pulmonary gas exchange region was estimated by size distribution, the deposition rate of dust collected from platform was higher than those of dust collected from lobby and pathway. The lower the basement levels were, the higher the deposition rates of dusts into tracheobronchial region and gas exchange region were. Copper and iron concentrations measured in platform higher were than those in other areas.

A Case of Multi-Organ Macronodular Tuberculosis (다기관성 대결절성 결핵 1예)

  • Lim, Kyoung-Ree;Kang, Myung-Ho;Kim, Tae-Suk;Moon, Ki-Won;Ryu, Dong-Ryeol;Lee, Hui-Young;Han, Seon-Sook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.88-92
    • /
    • 2012
  • A 37 year old female presented with epigastric pain and weight loss over a period of 3 months. Her abdominal CT finding showed a 4.5 cm size hepatic mass and 4.3 cm size pancreatic head mass with multiple macronodules in the liver. At the same time, her chest CT revealed a 5 cm size necrotic mass in the left lower lobe of the lung with multiple bilateral pulmonary nodules. We diagnosed these lesions as tuberculosis through multiple biopsies. She was treated with anti-tuberculous medication. After taking the medications, her symptoms were improved. Twelve months later, imaging studies indicated an improvement in the patient's health. Here we report a case report of multi-organ macronodular tuberculosis in lung, liver and pancreas.

A study on the Large High Speed Press Plunger Structure and Dynamic Bottom Dead Center Displacement (대형 고속프레스 플런저 구조와 동적 하사점 변위량에 대한 연구)

  • Seung-Soo Kim;Chun-Kyu Lee
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.40-45
    • /
    • 2022
  • The EV electric vehicle market is growing rapidly worldwide. An electric vehicle means a vehicle that uses energy charged through an electricity source as power. The precision of the press is important to mass-produce the drive motor, which is a key component of the electric vehicle. The size of the driving motor is increasing, and The size of the mold is also growing. In this study, the precision of large high-speed presses for mass production of driving motors was measured. A study was conducted on the measurement method of press and the analysis of measurement data. A drive motor is a component that transmits power by converting electrical energy into kinetic energy. EV driven motors have key material properties to improve efficiency. The material properties are the thickness of the material. As a method for improving performance, use a 0.2mm thin steel sheet. Mold is also becoming larger. As the mold grows, the size of the high-speed press for mass production of the driving motor is also increasing. Also, the precision of the press is the most important because it uses a thin iron plate material. So the importance of large press precision is being emphasized. In this study, the effect of large high-speed press structure on precision was verified

Analysis of Factors Influencing Changes in Left Atrium and Left Ventricle Size in Adults (성인의 좌심방과 좌심실 크기변화에 미치는 영향 요인 분석)

  • Sun-Hwa Kim;Sung-Hee Yang
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2024
  • This study analysed the factors that predict and influence heart disease through key indicators related to changes in left atrial and left ventricular size. Measurements recommended by the American Society of Echocardiography were used, and the influence of variables was assessed using multiple regression analysis. The results showed that left atrial volume index(LAVI) was significantly different by age, obesity, diabetes, hypertension, dyslipidaemia, and left ventricular relaxation dysfunction(p<0.05). Left ventricular mass index(LVMI) was significantly different according to age, body mass index, hypertension, diabetes, dyslipidaemia, and left ventricular relaxation dysfunction(p<0.05). Increases in LVMI and relative ventricular wall thickness(RWT) were associated with changes in LAVI(p<0.05). Age, systolic blood pressure, increased LAVI, and RWT influenced changes in LVMI, and left ventricular dysfunction was analysed as an influencing factor for both changes in LAVI and LVMI. Therefore, changes in left atrial and left ventricular size are indicators for early diagnosis and prevention of heart disease, and it is necessary to carefully observe structural changes in the heart and actively manage risk factors for the prevention and management of heart disease.

Characterization of Size Distribution and Water Solubility of 15 Elements in Atmospheric Aerosols

  • Park, Jeong-Ho;Sun, Jeong-Min;Park, Kum-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E1
    • /
    • pp.1-7
    • /
    • 2001
  • The elemental characteristics of atmospheric aerosols were investigated as a function of particle size and water solubility. The aerosol particles were samples at 12 individual size ranges between 0.01 and 30㎛. Collected aerosol particles were separated into both soluble and insoluble components. The concentrations of 15 elements in both components were determined by a PIXE analysis using a 2.0 MeV-proton beam. In general, the mass size distribution of particulate matter was represented as a bimodal distribution. The maximum rations of S in July and December were 5.5 and 3.8 %, and they appeared in the size range of 0.47∼1.17㎛(stage No. 6 or 7) . The ratios of a S at non-separated size were 3.1 and 2.2 % in July and December, respectively, On the other hand, the maximum rations of Si in July and December were 7.0 and 5.4% and they appeared in the size range of 5.1∼30㎛(stage No. 0∼2). The ratios of Si at the non-separated size were 2.1 and 1.8% in July and December, respectively, The mass diameter of 12 elements ranged between 0.59㎛ of S and 3.20 of Fe. More than 90% of atmospheric aerosols consisted of the light elements such as C, N, O, H and Al. The soluble component was dominant in the smaller size range and the insoluble component in the larger size range. Large portions of Si. Ti and Fe existed in insoluble state. By contrast, S, Cl, Ca, Zn and Br were dissolved in water.