• Title/Summary/Keyword: management 3.0

Search Result 10,143, Processing Time 0.052 seconds

Analyzing Time in Port and Greenhouse Gas Emissions of Vessels using Duration Model (생존분석모형을 이용한 선박의 재항시간 및 온실가스 배출량 분석)

  • Shin, Kangwon;Cheong, Jang-Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4D
    • /
    • pp.323-330
    • /
    • 2010
  • The time in port for vessels is one of the important factors for analyzing the operation status and the capacity of ports. In addition, the time in port for vessels can be directly used for estimating the greenhouse gas emissions resulted from vessels in port. However, it is unclear which variables can affect the time in port for vessels and what the marginal effect of each variable is. With these challenges in mind, the study analyzes the time in port for vessels arriving and departing port of Busan by using a parametric survival model. The results show that the log-logistic accelerated failure time model is appropriate to explain the time in port for 19,167 vessels arriving and departing port of Busan in 2008, in which the time in port is significantly affected by gross tonnage of vessels, service capacity of terminal, and vessel type. This study also shows that the greenhouse gas emission resulted from full-container vessels, which accounted for about 61% of all vessels with loading/unloading purpose arriving and departing port of Busan in 2008, is about "17 ton/vessel" in the boundary of port of Busan. However, the hotelling greenhouse gas emissions resulted from non-container vessels (3,774 vessels; 20%) are greater than those from the full-container vessels. Hence, it is necessary to take into account more efficient port management polices and technologies to reduce the service time of non-container vessels in port of Busan.

A Comparative Study of Smart Manufacturing Innovation Supply Industry in Germany and Korea (독일과 한국의 스마트 제조혁신 전략에 대한 비교분석 및 시사점 - 양국의 공급산업 전략을 중심으로 -)

  • Sang-Jin Lee;Yun-Hyeok Choi;Jae Kyu Myung
    • Journal of Practical Engineering Education
    • /
    • v.14 no.3
    • /
    • pp.601-608
    • /
    • 2022
  • This study examines the current status of smart manufacturing innovation policies in Germany and Korea, compares and analyzes the supply industry strategies of both countries, and suggests the direction for Korea's smart manufacturing innovation supply industry. Germany's supply industry strategy aims to strengthen the market dominance of domestic suppliers through high technology, compatibility, and high reliability based on reference for global demanding companies. On the other hand, the Korea's supply industry strategy remains at the level improvement of the demanding companies by stage, so it is time to take a long-term and consistent response with the goal of implementing smartization at the advanced level. By referring to Germany's supply industry strategy for the advancement of smart factories, it was intended to help in establishing government support policies and supplier strategies. In addition, based on the analysis results of the supply industry strategies of both countries, improvement measures for the advancement of Korea's smart factories were presented. Ultimately, the contents of this study can be used as basic data for policy establishment to strengthen the industrial competitiveness of Korea's small and medium-sized suppliers.

The Current State of Intended Equipment for Heating in Medical Use Based on Domestic Licensed Medical Devices (국내 인·허가 온열의료기기 기술 현황 조사 및 분석)

  • Su-Ran Lim;Jung-Hwan Park;Ji-Yeun Park;Song-Yi Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.156-168
    • /
    • 2023
  • Objectives : This study aimed to determine the status of thermal stimulation devices approved in Korea for medical applications over the past 10 years, and based on this, to obtain insight for future thermal treatment in Korean medical institutions. Methods : We searched the item classification list entitled "Regulations on Medical Device Items and Rating by Item" from the Ministry of Food and Drug Safety Notice No. 2021-24, 2021 (Enforced March 19, 2021; www.mfds.go.kr) for individually licensed heaters using the terms "heat" and "heating". Results : We identified 17 items of thermal stimulation product group, of which 1,308 devices were licensed by February 4, 2022, and 53.2% of them (n=696) were devices with valid permits for distribution in Korea. Among the licensed devices, heating pad systems under/overlay (electric, home use) were approved the most, but combinational stimulator (for medical use, home use; Grade 2) accounted for the highest percentage among the current valid permission. Moxibustion apparatuses were licensed separately for electrical use and non-electrical use, and occupied a low percentage of the total devices. We analyzed 307 devices that were accompanied by technical documents and found that the heat sources were wires in 145 (47.2%), infrared rays in 44 (14.3%) and ultrasonic waves in 42 (13.7%) devices. Most (83.1%) devices were used for pain relief, while other applications included beauty, cancer treatment, maintenance of infant body temperature, and healing fractures. Conclusions : Thermal stimulation devices accounted for about 0.9% of all medical devices, and among them, combinational stimulators and heating pad systems under/overlay had the most valid permits. Thermal stimulation devices using heating wires and infrared rays were the most prevalent, and most were used to relieve pain. In order to develop a range of thermal stimulation devices that can be utilized in Korean medical institutions, it is imperative that they have potential applications beyond pain management, addressing various medical purposes. To achieve this, foundational research is necessary to effectively apply diverse heat sources based on medical objectives.

Epidemiology of cleft lip and palate charity mission surgery at Bandung Cleft Lip and Palate Center, Indonesia: a 14-year institutional review

  • Ali Sundoro;Dany Hilmanto;Hardisiswo Soedjana;Ronny Lesmana;Selvy Harianti
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.2
    • /
    • pp.62-70
    • /
    • 2024
  • Background: The management of cleft lip and palate aims at improving the patient's aesthetic and functional outcomes. Delaying primary repair can disrupt the patient's functional status. Long-term follow-up is essential to evaluate the need for secondary repair or revision surgery. This article presents the epidemiology of cleft lip and palate, including comprehensive patient characteristics, the extent of delay, and secondary repair at our institutional center, the Bandung Cleft Lip and Palate Center, Faculty of Medicine, Universitas Padjadjaran, Bandung, Indonesia. Methods: This retrospective study aimed to determine the epidemiology and recurrence rates of cleft lip and palate at the Bandung Cleft Lip and Palate Center, Indonesia, from January 2007 to December 2021. The inclusion criteria were patients diagnosed with cleft lip and/or palate. Procedures such as labioplasty, palatoplasty, secondary lip and nasal repair, and alveolar bone grafting were performed, and data on recurrence were available. Results: In total, there were 3,618 patients with cleft lip and palate, with an age range of 12 months to 67 years. The mean age was 4.33 years, and the median age was 1.35 years. Males predominated over females in all cleft types (60.4%), and the cleft lip was on the left side in 1,677 patients (46.4%). Most cases were unilateral (2,531; 70.0%) and complete (2,349; 64.9%), and involved a diagnosis of cleft lip and palate (1,981; 54.8%). Conclusion: Delayed primary labioplasty can affect daily functioning. Primary repair for patients with cleft lip and palate may be postponed due to limited awareness, socioeconomic factors, inadequate facilities, and varying adherence to treatment guidelines. Despite variations in the timing of primary cleft lip repair (not adhering to the recommended protocol), only 10% of these patients undergo reoperation. Healthcare providers should prioritize the importance of the ideal timing for primary repair in order to optimize physiological function without compromising the aesthetic results.

Evaluation of Salt Tolerance of Three Foliage Plant as affected by Salinity Concentration in Indoor Ornamental Hydroculture (실내 관상용 물재배에서 염분농도에 따른 3가지 관엽식물의 내염성 평가)

  • Jin Hee Ju;Sun Young Park;Yong Han Yoon
    • Journal of Environmental Science International
    • /
    • v.33 no.4
    • /
    • pp.257-268
    • /
    • 2024
  • This study investigated the growth characteristics of Euonymus japonicus, Hedera helix, and Peperomia puteolata treated with different calcium chloride (CaCl2) concentrations to evaluate salt tolerance limits in hydroculture cultivation. Six concentrations of CaCl2 (0, 1, 2, 5, 10, and 15 g·L-1 referred to as Cont., C1, C2, C5, C10, and C15) were applied to solution - grown plant species. The survival rate, growth index, plant height, plant width, leaf width, leaf length, number of leaves, and relative chlorophyll contents were measured at monthly intervals. Euonymus japonicus, Hedera helix, and Peperomia puteolata survived up to C2, C5, and C10 at each CaCl2 concentration. The Euonymus japonicus was higher in the C1 treatment than in the Cont. for most growth characteristics. Hedera helix had the highest leaf width, leaf length, and number of leaves in the Cont., a significant difference was observed compared with the C1 treatment. The chlorophyll content did not differ significantly between the C5 and Cont. treatments. The leaf width and length of Peperomia puteolata were greater in the C2 and C1 treatments than in the Cont., whereas the number of leaves and chlorophyll content were the highest in C5. Dry weight analysis revealed that Euonymus japonicus, Hedera helix, and Peperomia puteolata were the lowest in the Cont. treatments. Euonymus japonicus was 74% in C15, and Hedera helix, and Peperomia puteolata were analyzed at approximately 37%- 50% and 9%-14%, respectively, regardless of the concentration in the CaCl2 treatment groups. In indoor hydroponic cultivation, the salt tolerance limit concentrations of Euonymus japonicus, Hedera helix, and Peperomia puteolata are 2, 5, and 10 g·L-1, respectively, indicating that hydroculture management techniques should be applied at higher concentrations.

4-year Course Curriculum of Dental Hygiene in Korea (한국 4년제 치위생학과의 교육과정)

  • Lee, SuYoung;Hwang, SooJeong
    • Journal of Korean Dental Hygiene Science
    • /
    • v.2 no.1
    • /
    • pp.41-50
    • /
    • 2019
  • Education should consider the social consensus that changes according to the times and the social environment, and it is also necessary to consider the technically useful subjects. We collected and reported the 4-year course curriculum of dental hygiene when Korean dental hygiene education has continued over 50 years. Each 4-year course curriculum was collected by searching each university website, or requested by email. The curriculum of 23 among 27 schools was collected. According to the classification of dental hygiene in the dental hygienist national examination classification or the Korean society of dental hygiene science, the subjects of the course were divided into clinical dental hygiene, clinical dental treatment support, basic dental hygiene, social and educational dental hygiene, and collected 23 curriculum courses. The average major curriculum was 104.9 credits and the average number of subjects in major courses was 34.3. The average subjects' number of clinical dental hygienic courses was 33.9 (37.5% of the total major credits), clinical dental treatment support was 30.6 (30.2% of the total major credits), basic dental hygiene was 21.8 (20.8% of the total major credits), and social and educational dental hygiene courses was 13.6 (13.0% of total major credits). Integrated subjects' name in clinical dental hygiene was used in all schools of the survey, such as clinical dental hygiene education (and practice), comprehensive dental hygiene education, and integrated dental hygiene. There were 13 schools (56.5%) that use the integrated name in clinical dental treatment support, such as clinical dentistry. There were 14 schools (60.9%) to open dental clinic management, and 22 schools (95.7%) to open national health insurance claims. The basic dental hygiene curriculum maintained the title of each subject and social and educational dental hygiene education was established in most schools, such as community dental health, oral health statistics, and oral health education. Other subjects were English conversation in dental clinic (8 schools) education, clinical dental treatment support, basic science in dental hygiene, social and educational dental hygiene. We knew the clinical dental hygiene and clinical dental treatment support were changing into the integrated subjects, and most schools run dental hygiene research.

Fraud Detection System Model Using Generative Adversarial Networks and Deep Learning (생성적 적대 신경망과 딥러닝을 활용한 이상거래탐지 시스템 모형)

  • Ye Won Kim;Ye Lim Yu;Hong Yong Choi
    • Information Systems Review
    • /
    • v.22 no.1
    • /
    • pp.59-72
    • /
    • 2020
  • Artificial Intelligence is establishing itself as a familiar tool from an intractable concept. In this trend, financial sector is also looking to improve the problem of existing system which includes Fraud Detection System (FDS). It is being difficult to detect sophisticated cyber financial fraud using original rule-based FDS. This is because diversification of payment environment and increasing number of electronic financial transactions has been emerged. In order to overcome present FDS, this paper suggests 3 types of artificial intelligence models, Generative Adversarial Network (GAN), Deep Neural Network (DNN), and Convolutional Neural Network (CNN). GAN proves how data imbalance problem can be developed while DNN and CNN show how abnormal financial trading patterns can be precisely detected. In conclusion, among the experiments on this paper, WGAN has the highest improvement effects on data imbalance problem. DNN model reflects more effects on fraud classification comparatively.

Homocysteine levels are associated with diabetes mellitus in Chinese with H-type hypertension

  • Dejian Fu;Wanbao Gong;Xiaomin Bao;Bo Yang;Feng Wang;Yubing Qiao;Yuanjiang Wu;Guangzhen Chen;Weixun Sun;Qiongzhi Xiao;Wenbo Zou;Ning Fang
    • Nutrition Research and Practice
    • /
    • v.18 no.4
    • /
    • pp.511-522
    • /
    • 2024
  • BACKGROUND/OBJECTIVES: The study examined the association between homocysteine and diabetes mellitus in patients with H-type hypertension and assessed the possible effect modifiers. SUBJECTS/METHODS: This cross-sectional study included 1,255 eligible participants in the 'H-type Hypertension Management and Stroke Prevention Strategic International Science and Technology Innovation Cooperation Project' among rural Chinese people with H-type hypertension. A multivariate logistic regression model was used to evaluate the relationship between homocysteine and diabetes mellitus. RESULTS: The mean level of total homocysteine (tHcy) in the diabetes mellitus population was 19.37 μmol/L, which was significantly higher than the non-diabetic patients (18.18 μmol/L). When tHcy was analyzed as a continuous variable, the odds ratio (OR) of diabetes was 1.17 (95% confidence interval [CI], 1.01-1.35; per interquartile range). When tHcy was stratified according to the quintile, the ORs for diabetes were 2.86 (95% CI, 1.22-6.69) in the highest quintile (tHcy ≥ 20.60 μmol/L) compared to the reference group (tHcy < 12.04 μmol/L). When tHcy was grouped by 15 μmol/L and 20 μmol/L, patients with tHcy ≥ 20 μmol/L had a significantly (P = 0.037) higher risk of diabetes (OR, 2.03; 95% CI, 1.04-3.96) than in those with tHcy < 15 μmol/L. Subgroup analysis showed that the tHcy-diabetes association was unaffected by other variables. CONCLUSION: In this study of rural Chinese people with H-type hypertension, the tHcy levels showed a positive association with diabetes mellitus. This independent association is unaffected by other potential risk factors.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Deep Neck Abscesses in Korean Children (소아 심부 경부 농양에 대한 임상적 고찰)

  • Lee, Dae Hyoung;Kim, Sun Mi;Lee, Jung Hyun;Kim, Jong Hyun;Hur, Jae Kyun;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.1
    • /
    • pp.81-89
    • /
    • 2004
  • Purpose : Retropharyngeal and parapharyngeal abscesses are often distinguishable from other head and neck abscesses on clinical grounds, but these infections can combine and the presentations are similar to one another. Because of the advances of antibiotic therapy, the frequency of the diseases decreased considerably, but recently the incidence of neck abscesses has increased. We sought to describe the clinical presentation of patients with deep neck abscess, and implications on management. Methods : For 10 year periods, 94 cases of charts were reviewed retrospectively, who were diagnosed as neck abscesses aged below 16 years old(between January 1993 to August 2003) in 4 hospitals. Deep neck abscesses were diagnosed by surgical pus drainage, neck CT (homogenous, hypodense area with ring enhancement) and neck sono findings. Results : The annual incidence of deep neck abscess has been increased since 2000. The median age of the patients was 4 years(range, 26 days~15 years); 63% of the patients were younger than 5 years. Abscesses in the submandibular space(34%) were most common, followed by peritonsillar space(29.7%), retropharyngeal space(11.7%), combined(10.8%), parotid space(7.4%) and parapharyngeal space(6.4%). Fever(73.4%), sore throat(37.2%), decreased oral intake(34%) and neck pain(27.7%) were the most common symptoms. In 6 children(6.4%), there was refusal to move neck, in 6(6.4%) headache, and in 4(4.3%) torticollis. Respiratory distress was observed in only 1 patient(2.1%) and stridor in 1 other(2.1%). The most common physical examinations were neck swelling/mass(67%), pharyngitis(46.8%), tonsillitis(36.2 %), and cervical lymphadenopathy(28.7%). Neck stiffness was observed in 4 patients(4.3%). Total 35 organisms were isolated in 33 patients. The most common organisms cultured by patients' blood or pus were S. aureus(34%) and S. pyogenes(28.6%). Most organisms were gram positive, and had sensitivities in vancomycin(96.4%), cefotaxime(88.9%), cephalothin (86.4%), trimethoprime-sulfamethoxazole(83.3%), and clindamycin(77.8%). 77 patients(81.9%) underwent surgery plus antibiotics; 17 patients(18.1%) were treated with antibiotics only. There is no significant differences between two groups. In duration of admission, fever after admission, and antibiotic treatment. Conclusion : The incidence of deep neck abscess has increased recently and the major symptoms have been changed. The incidence of respiratory distress or stridor is decreasing, while the incidence of abnormal head and neck symptoms and signs like headache, neck stiffness, refusal to move neck, or torticollis are increasing. Gram positive organisms are predominant, S. aureus is the most common followed by S. pyogenes. 1st generation cephalosporin has high sensitivity on gram positive organisms. Treatment with surgery plus antibiotics dose not significantly decrease total duration of antibiotic treatment or admission compared to treatment with antibiotics alone.

  • PDF