• Title/Summary/Keyword: maintenance of equipments and facilities

Search Result 50, Processing Time 0.03 seconds

Observation on power system characteristic changes in case of outage (주요설비 휴전시 계통 특성변화 고찰)

  • Lee, Woon-Hee;Lee, Chang-Gun;Joo, Hang-Roe;Jang, Sung-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.429-430
    • /
    • 2007
  • The enlargement of an electric power system network gives us much challenges concerning with network operation. In addition to it, the fast aging process of network equipments requires more chance to check and maintenance, and also the increase of heavy loaded facilities and the increase of the fault current in the network need to exchange with the larger facilities in capacity. Due to these reasons, outages trend to increase. Network solution studies for outages are performed mainly for two purposes. The first one is to find the countermeasures when the outage causes a violation of the network reliability criteria. And the second one is to minimize network constraints due to outages. There are so many outages around 400 for only one month. Therefore, in order to do case studies for outage, not only skilled persons are needed, but also many available tools to help properly. Concerning with proper tools, we will introduce a program which we developed to get informations concerned with network sensitivity, and an example to apply that program.

  • PDF

Simplified GIS Diagnostic SYSTEM (간이형 상시 GIS 진단장치)

  • Jeong, J.K.;Choi, Y.J.;Kang, C.I.;Jang, H.K.;Gwak, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.74-77
    • /
    • 2006
  • This research is focused on the development of GIS Diagnostic SYSTEM to prevent accidents beforehand by inspecting the internal defects of GIS (Gas Insulated Switchgear) which is a main power-facility for substations. GIS Diagnostic SYSTEM is categorized as 'Real time on-line test type' and 'Portable test type' depending on the types of testing, it uses PD(partial discharge) which mostly incurs in GIS internal defects, to inspect. As of now, mostly foreign equipments are imported for use due to the lack of the technology localization, and these are installed and operated on only some parts of highly-graded GIS power-facilities such as in 76skv or 345kv for its being expensive. Furthermore, other than foreign equipments being costly, it also has a weak point of very long unavailability in case of Diagnostic system break-down while using, because it takes a comparatively long period of corrective maintenance precesses. We have localized to develop personal real-time multi -functional GIS Diagnostic system which can test on all GIS power-facility comprehensively and economically therefore overcome all these problems mentioned above, a market expansion is expected from the decrease of price and replacing the import equipments in the future. As the equipment was developed to be Personal for the simple ways of installing and utilizing, it can be operated without any complex cable installation like other existing GIS Diagnostic system requires, therefore also decrease the cost of cable installation.

  • PDF

Development of Regression Model to evaluate the indirect costs of Life-Cycle Costs (생애주기비용의 간접비용 산출을 위한 Regression Model의 개발)

  • 조효남;이종순;김충완;박경훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.150-156
    • /
    • 2004
  • Though the concept of Life-Cycle Cost (LCC) itself is not new, its effectiveness for planning, design, rehabilitation and maintenance/management of civil infrastructures is becoming increasingly recognized. For the decision problems as in the case of the LCC of plant facilities, equipments, bridge decks, pavements, etc., the Life-Cycle Cost Analysis (LCCA) is relatively simple, and thus its practical implementation is rather straightforward. However, when it comes to major infrastructures such as bridge, tunnels, underground facilities, etc., the LCCA problem becomes extremely complex because lack of cost data associated with various direct and indirect losses, and the absence of uncertainty data available for the assessment as well. As a result, the LCC studies have been largely limited only to those relatively simple LCCA problems of planning or conceptual design for making decisions. Accordingly, in the recent years, the researchers have pursued extensive studies on the LCC effectiveness mostly related to LCC models and frameworks for civil infrastructures. Moreover, recently the demand on the practical application of LCC effective decisions in design and maintenance is rapidly growing unprecedently in civil engineering practice. Indirction cost is very important on LCC formulation. But that is very difficult and complicate the estimation every LCC. The objective of this paper is to suggest efficient regression model for the estimation of indirect cost approach to the practical application of LCC for the design and rehabilitation of civil. infrastructures considering traffic, traffic network, detour condition, and workzone condition. In this paper, it performed the sensitivity analysis and correlation analysis of parameter for development of regression model of inflection cost.

  • PDF

Development of outage-free installation method and equipments for underground power distribution system (지중배전선로 무정전 공법의 최적화를 위한 장비 개발)

  • Yu, K.Y.;Joo, J.M.;Lee, Y.S.;Kim, Y.M.;Kang, N.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.122-124
    • /
    • 2005
  • Underground distribution system is a trend due to the successive development of metropolitan area and satellite cities and the environment of the commercial and residential areas. The high quality of electricity, which is related with the minimal outage duration time due to the maintenance work for the underground distribution line, is mandatory. Hence, the construction method and tools for the outage-free maintenance construction have been required for underground distribution system. So far, all the efforts for outage-free maintenance for the underground distribution have been limited only to the survey for foreign countries situation and the theoretical provision; thus, It is required to develop the various construction method and the application tools. Differently from the aerial line, the construction of the underground cable is complicated and the insulation distance between conductor and shield should be maintained in loadmaking/breaking operation, though the apparatus connected with cable is a deadfront type. Also since the apparatus is installed above ground, by-pass of faulted area at busy area needs a variety of high technologies. Therefore, in this these, the authors introduce the development status of the loadbreak connectors, connection facilities, outage-free maintenance system for secondary side, a secondary auxiliary bushing and additional tools so that there can be more progress on this field.

  • PDF

Assessment of Foodservice Management Practices in the Educare Centers in Jeonbuk Province (전북지역 영유아 보육시설의 급식관리 실태평가)

  • Lee, Young-Eun;Kim, Hyang-Sook
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.217-233
    • /
    • 1998
  • Foodservice management practices in 52 educare centers in Jeonbuk province were evaluated in order to provide basic informations and guidelines for the standardization of foodservice management and facilities in the educare centers. The survey was conducted using the structured questionnaire. The results are summarized as follows: 1. Only 10% of the centers investigated had the stationed dietitian, therefore most of foodservice management was not conducted by a professional personnel. The average number of kitchen employees was 1.3 and significantly different with type(p<0.05) and size(p<0.001) of the centers, which was not enough to meet the regulation. 2. Menu planning was performed mostly(59.6%) by managers and teachers of educare centers. Food items were purchased(94.7%) and recieved(91.6%) by kitchen employees or center managers and teachers. Produced foods were also evaluated(97.7%) and distributed(100%) by kitchen employees or center managers and teachers depending on their experience without any supervision of the professional personnel for the mass production. 3. Among the centers studied, 84.6% of them conducted nutrition education programs regularly by teachers. About 77.3% of them evaluated that these programs did not accomplish the proper training for good food habit because of the lack of nutritional knowledge(54.5%) and educational media(27.3%). 4. In general, the hygienic maintenance was evaluated as fair state to need the improvement. 5. Kitchen facilities and equipments were similar to those of home cooking and did not meet the standards for institutional practices. Besides, automated machinery and tools for safety, sanitation and improvement of work efficiency were far short. 6. Log book for the foodservice management was not prepared properly, which made the systematic planning and operation of the foodservice facilities difficult.

  • PDF

A Study on the Application Ratio by the New and Renewable Energy Systems Fit for Public Medical Facilities (공공의료시설에 적합한 신재생에너지시스템의 복합적용비율에 관한 연구)

  • Hong, Jun-Ho;Lee, Yong-Ho;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.32-43
    • /
    • 2014
  • This study set out to identify the importance of each factor influencing facility selection with a survey among public medical facilities under the category of public buildings and apply the importance of economy, technology and environment with the weighting factor method, thus proposing optimal application plans. The research content of each section can be summarized as follows:1) Estimated energy consumption according to the energy simulation was 65,129MWh/yr, which was 18.7% higher than that according to the calculation equation. Of the energy consumption, more than 80% was used by heating and cooling facilities and construction facilities, and 20% was used by electronics such as medical equipments and in and outdoor lighting. 2) The results of a survey on the factors influencing the importance when selecting a new and renewable energy system reveal that the upper items had a priority in economy, environment, and technology in the descending order and that the lower item shad a priority in initial investments, maintenance and repair costs=energy costs, supply reliability, energy efficiency and $CO_2$ emissions in the descending order. 3) The application alternatives were analyzed in economy, technology, and environment. As a result, a geothermal system turned out to be the most excellent one a cross all the upper and lower comparison items. Of the other systems, a solar thermal system was superior in initial investments, maintenance and repair costs, and energy efficiency, where as a photovoltaic system was superior in energy costs, supply reliability, and $CO_2$ emissions. 4) As for the mixed application ratio among economy, technology, and environment, when the percentage of a geothermal system was approximately 80% or higher in anew and renewable energy system, it was the best and most optimal application plan.

An inquiry into the distribution and application plan of new-renewable energy in Military facilities (군 시설 신재생에너지 보급동향과 적용방향 고찰)

  • Kim, Chul;Kyung, Seo-Kyung;Cho, Woo-Seok;Oh, Myung-Won;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.269-276
    • /
    • 2009
  • South Korea having military power within the $10^{th}$ in world ranking is the biggest single institution among public institutions in Korea and comprises force of over seven hundred thousand soldiers. However, outworn equipments and efficiency problem have issued. So, this study is to search the distribution state of new-renewable energy and to analyze application plan on the basis of interview with a official in charge in military. Analysis process is the first, classify surveyed military facilities into troops and the geographical factor. Second, classify a scale and type of facilities that new-renewable energy is supplied. Third, find consideration facts on the basis of interview with a official in charge. On the results of the survey, new-renewable energy applied to the military facility is photovoltaic, solar heat, wind power and geo-thermal energy. Also, divide military into the army, navy, air force and marine, visit 14 units and analyze the official's opinion. This study will deduce LCCA(Life cycle cost analysis) considered expenses for the installation and maintenance, and will be basic research that suggest an appropriate new-renewable energy model in military.

  • PDF

Development of Stand-Alone Risk Assessment Software for Optimized Maintenance Planning of Power Plant Facilities (발전설비 최적 정비를 위한 독립형 위험도 평가 소프트웨어 개발)

  • Choi, Woo Sung;Song, Gee Wook;Kim, Bum Shin;Chang, Sung Ho;Lee, Sang Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1169-1174
    • /
    • 2015
  • Risk-Risk-based inspection (RBI) has been developed in order to identify risky equipments that can cause major accidents or damages in large-scale plants. This assessment evaluates the equipment's risk, categorizes their priorities based on risk level, and then determines the urgency of their maintenance or allocates maintenance resources. An earlier version of the risk-based assessment software is already installed within the equipment management system; however, the assessment is based on examination by an inspector, and the results can be influenced by his subjective judgment, rather than assessment being based on failure probability. Moreover, the system is housed within a server, which limits the inspector's work space and time, and such a system can be used only on site. In this paper, the development of independent risk-based assessment software is introduced; this software calculates the failure probability by an analytical method, and analyzes the field inspection results, as well as inspection effectiveness. It can also operate on site, since it can be installed on an independent platform, and has the ability to generate an I/O function for the field inspection results regarding the period for an optimum maintenance cycle. This program will provide useful information not only to the field users who are participating in maintenance, but also to the engineers who need to decide whether to extend the lifecycle of the power machinery or replace only specific components.

Study on the Oxidation Treatment of Nanoparticles for the Critical Heat Flux (임계열유속 향상을 위한 나노물질의 산화처리에 대한 연구)

  • Kim, Woo-Joong;Jeon, Yong-Han;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.39-49
    • /
    • 2017
  • Pool boiling, one of the key thermal-hydraulics phenomena, has been widely studied for improving heat transfer efficiencies and safety of nuclear power plants, refrigerating systems, solar-collector heat pipes, and other facilities and equipments. In the present study, the critical heat flux (CHF) and heat-transfer coefficients were tested under the pool-boiling state using graphene M-5 and M-15 nanofluids as well as oxidized graphene M-5 nanofluid. The results showed that the highest CHF increase for both graphene M-5 and M-15 was at the 0.01% volume fraction and, moreover, that the CHF-increase ratio for small-diameter graphene M-5 was higher than that for large-diameter graphene M-15. Also at the 0.01% volume fraction, the oxidized graphene M-5 nanofluid showed a 41.82%-higher CHF-increase ratio and a 26.7%-higher heat-transfer coefficient relative to the same nanofluid without oxidation treatment at the excess temperature where the CHF of distilled water occurs.

Development of Algorithm for Vibration Analysis Automation of Rotating Equipments Based on ISO 20816 (ISO 20816 기반 회전기기 진동분석 자동화 알고리즘 개발)

  • JaeWoong Lee;Ugiyeon Lee;Jeongseok Oh
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.93-104
    • /
    • 2024
  • Facility diagnosis is essential for the smooth operation and life extension of rotating equipment used in industrial sites. Compared to other diagnostic methods, vibration diagnosis can find most of the initial defects, such as unbalance, alignment failure, bearing defects and resonance, compared to other diagnostic methods. Therefore, vibration analysis is the most commonly used facility diagnosis method in industrial sites, and is usefully used as a predictive preservation (PdM) technology to manage the condition of the facility. However, since the vibration diagnosis method is performed based on experience based on the standard, it is carried out by experts. Therefore, it is intended to contribute to the reliability of the facility by establishing a system that anyone can easily judge defects by establishing a vibration diagnosis method performed based on experience as a knowledgeable code system. An algorithm was developed based on the ISO-20816 standard for vibration measurement, and the reliability was verified by comparing the results of vibration measurement at various demonstration sites such as petrochemical plant compressors, hydrogen charging stations, and industrial machinery with the results of analysis using a development system. The developed algorithm can contribute to predictive maintenance (PdM) technology that anyone can diagnose the condition of the rotating machine at industrial sites and identify defects early to replace parts at the exact time of replacement. Furthermore, it is expected that it will contribute to reducing maintenance costs and downtime due to the failure of rotating machines when applied to various industrial sites such as oil refining facilities, transportation, production facilities, and aviation facilities.