• 제목/요약/키워드: magnetic switch

검색결과 171건 처리시간 0.023초

CT and MRI for Repaired Complex Adult Congenital Heart Diseases

  • Suvipaporn Siripornpitak;Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • 제22권3호
    • /
    • pp.308-323
    • /
    • 2021
  • An increasing number of adult congenital heart disease (ACHD) patients continue to require life-long diagnostic imaging surveillance using cardiac CT and MRI. These patients typically exhibit a large spectrum of unique anatomical and functional changes resulting from either single- or multi-stage palliation and surgical correction. Radiologists involved in the diagnostic task of monitoring treatment effects and detecting potential complications should be familiar with common cardiac CT and MRI findings observed in patients with repaired complex ACHD. This review article highlights the contemporary role of CT and MRI in three commonly encountered repaired ACHD: repaired tetralogy of Fallot, transposition of the great arteries after arterial switch operation, and functional single ventricle after Fontan operation.

ANALYSIS AND OPTIMIZATION of INJECTION TIMING for AN ADVANCED COMPRESSED AIR ENGINE KIT

  • Kumar, Akshay;Kumar, Vasu;Gupta, Dhruv;Kumar, Naveen
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.54-63
    • /
    • 2015
  • Increasing air pollution levels and the global oil crisis has become a major hindrance in the growth of our automobile sector. Traditional Internal Combustion engines running on non-renewable fuels are proving to be the major culprit for the harmful effects on environment. With few modifications and also with assistance of few additional components current small SI engines can be modified into a pneumatic engine (commonly known as Compressed Air Engines) without much technical complications where the working fluid is compressed air. The working principle is very basic as adiabatic expansion of the compressed air takes place inside the cylinder pushing the piston downwards creating enough MEP to run the crank shaft at decent RPM. With the assistance of new research and development on pneumatic engines can explore the potential of pneumatic engines as a viable option over IC engines. The paper deals with analysis on RPM variation with corresponding compressed air injection at different crank angles from TDC keeping constant injection time period. Similarly RPM variation can also be observed at different injection pressures with similar injection angle variation. A setup employing a combination of magnetic switch (reed switch), magnets and solenoid valve is used in order to injection timing control. A conclusive data is obtained after detailed analysis of RPM variation that can be employed in newly modified pneumatic engines in order to enhance the running performance. With a number of benefits offered by pneumatic engine over IC engines such as no emissions, better efficiency, low running cost, light weight accompanied by optimized injection conditions can cause a significant development in pneumatic engines without any major alteration.

고정밀 전류센서를 이용한 저압배전계통 이중 보호용 전기화재 방재장치 (Electrical Fire Disaster Prevention Device of Double Protection using a High Precision Current Sensor in Low Voltage Distribution System)

  • 곽동걸;정도영
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.40-47
    • /
    • 2009
  • 오늘날 전기제품의 다양화, 대용량화와 더불어 전기화재의 발생이 점차 증가하고 있다. 반면 저압 배전계통에서 사용되고 있는 기존의 과부하겸용 누전차단기 즉, RCD의 저조한 응답특성으로 인한 전기화재 원인의 대부분을 차지하는 단락사고 및 과부하사고에 대한 대응이 매우 미흡한 실정이다. 이에 본 논문에서는 기존 RCD에 대한 모의 사고실험을 통하여 그 비신뢰성을 확인하고, 이러한 RCD의 단점을 개선하고자 고정밀 전류센서를 이용한 전기화재 방재장치를 제안하여 저압 배전계통에서의 단락 및 과부하사고로 인한 전기재해를 방지하고자 한다. 제안한 장치의 고정밀 전류센서로 사용된 리드스위치는 각종 전기사고에서 수반되는 단락전류 및 과전류에 의한 배전선로의 상승된 자속을 정밀 감지한 후, 자체 차단장치를 동작시키거나 또는 기 설치된 RCD를 신속히 차단시키는 이중 보호용 제어 동작원리를 가진다. 다양한 동작특성 분석을 통해 기존의 차단기와 비교하여 차단동작 응답속도와 신뢰성이 입증된다. 이로써 제안한 전기화재 방재장치는 기존 RCD들의 빈번한 오동작과 비신뢰성, 저조한 응답특성으로 인한 각종 전기사고 및 전기화재의 발생을 방지하고자 한다.

원통형 영구자석을 이용한 쌍안정 장치 설계 (Design of Bi-stable Mechanism Using Cylindrical Permanent Magnets)

  • 양현호;최재용;한재흥
    • 한국항공우주학회지
    • /
    • 제48권5호
    • /
    • pp.343-354
    • /
    • 2020
  • 쌍안정 장치는 서로 다른 두 가지 상태에서 안정성을 갖는 시스템이며, 구동에 있어 에너지 효율 측면에서 이득을 얻을 수 있다. 이러한 쌍안정 장치는 다양한 방법을 통해 구현되며, 전개형 구조물, 스위치 시스템 그리고 파지 로봇 등, 주된 동작이 두 종류로 구분되는 모핑 시스템에 적용될 수 있다. 하지만 기존 장치들의 복잡성과 구조적 제한 때문에, 링크 구조물처럼 회전하는 구조를 포함하는 모핑 시스템을 구현하는 것은 어려움이 존재한다. 본 연구에서는 원통형 영구자석을 이용하여 회전운동에 있어 쌍안정성을 갖는 장치를 구현하는 방법이 제안된다. 원통형 영구자석의 전자석 모델을 도입하여 자기장과 자기력을 도출했으며, 이를 이용하여 원통형 영구자석을 포함하는 두 링크 사이의 힘 관계를 추정했다. 대칭 쌍안정성을 위한 원통형 영구자석의 배열을 선정했으며, 제안하는 쌍안정 장치를 회전 조인트로 연결된 링크 구조물에 적용하여 외부 토크에 대한 안정성을 실험을 통해 확인하였다.

Oxidation-induced conformational change of Hsp33, monitored by NMR

  • Lee, Yoo-Sup;Kim, Ji-Hoon;Seo, Min-Duk;Ryu, Kyoung-Seok;Kim, Eun-Hee;Won, Hyung-Sik
    • 한국자기공명학회논문지
    • /
    • 제19권3호
    • /
    • pp.99-105
    • /
    • 2015
  • Hsp33 is a prokaryotic molecular chaperon that exerts a holdase activity upon response to an oxidative stress at raised temperature. In particular, intramolecular disulfide bond formation between the four conserved cysteines that bind a zinc ion in reduced state is known to be critically associated with the redox sensing. Here we report the backbone NMR assignment results of the half-oxidized Hsp33, where only two of the four cysteines form an intramolecular disulfide bond. Almost all of the resolved peaks could be unambiguously assigned, although the total assignments extent reached just about 50%. Majority of the missing assignments could be attributed to a significant spectral collapse, largely due to the oxidation-induced unfolding of the C-terminal redox-switch domain. These results support two previous suggestions: conformational change in the first oxidation step is localized mainly in the C-terminal zinc-binding domain, and the half-oxidized form would be still inactive. However, some additional regions appeared to be potentially changed from the reduced state, which suggest that the half-oxidized conformation would be an intermediate state that is more labile to heat and/or further oxidation.

Integrated Magnetics를 적용한 고속 스위칭 및 고전력밀도 3 레벨 LLC 공진형 컨버터 (High Switching Frequency and High Power Density Three-Level LLC Resonant Converter using Integrated Magnetics)

  • 남경훈;박철완;배지훈;지상근;류동균;최흥균;한상규
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.551-554
    • /
    • 2017
  • This paper proposes a three-level LLC resonant converter using integrated magnetics (IM). Given that the switch voltage stress of the proposed converter is guaranteed to be half of the input voltage, the switching losses can be greatly reduced, thereby benefitting the high-frequency operation. To reduce the volume of reactive components such as transformers, high-frequency driving and planar core are applied. However, two resonant inductors and one transformer are required because of the three-level structure and the limited leakage inductance of the planar transformer for the resonant operation. Therefore, the effect of volume reduction is not very large. In order to solve these drawbacks, this paper proposes a new IM that integrates all magnetic elements used in the proposed three-level resonant converter by using the magnetizing inductor as a resonant inductor. The experimental results are presented by conducting a theoretical analysis of a prototype with 350 W to 800 kHz.

회귀 분석 기법을 활용한 전자 개폐기의 온도 변화예측 (Thermal Change Prediction of Magnetic Switch Using Regression Analysis)

  • 문철한;연영모;김승희;민준기
    • 문화기술의 융합
    • /
    • 제8권6호
    • /
    • pp.749-755
    • /
    • 2022
  • 전기는 다양한 산업에 이용되는 등 현대 사회에 있어서 필수적인 에너지이다. 그러나, 이를 다루기 위한 전자배선 상에서 발생하는 화재의 비율이 매우 높다. 본 연구에서는 다양한 회귀 모델들을 사용한 분석을 통하여 전기 회로의 온도 변화를 예측하는 시스템을 구현하였다. 이를 위해 전기 회로를 제어하는 전자 접촉기 27종을 사용한 회로상의 온도 데이터를 수집하고 수집된 온도 데이터를 이용하여 회귀 모델들을 훈련하였다. 실험에서 실제 온도와 예측온도의 차이가 평균 4℃ 정도 발생하여, 이를 통해 충분히 사용 가능한 수준의 모델을 훈련할 수 있음을 확인하였다. 이와 같은 연구 결과는 전기 회로의 온도 예측 및 화재 예방에 도움이 될 것이다.

Nd-YAG Pulsed Laser Ablation법으로 제작한 SmCo계 박막의 자기특성 (Magnetic Properties of SmCo Thin Films Grown by Using a Nd-YAG Pulsed Laser Ablation Method)

  • 김상원;양충진
    • 한국자기학회지
    • /
    • 제10권1호
    • /
    • pp.30-36
    • /
    • 2000
  • Q switch mode 혹은 Fixed Q mode Nd-YAG 레이저 어블레이션법으로 (100)Si 기판위에 SmCo 박막을 증착하였다. 증착시 Sm$_{100-x}$Co$_{x}$ (73$\leq$x$\leq$93) 조성의 타겟을 사용하였고, 기판온도는 600~$700^{\circ}C$ 변화시켰으며 각 mode 에너지를 조절하였다. Q switching mode로 증착된 박막의 4$\pi$Ms, $_{i}$H$_{c}$ 및 4$\pi$M$_{r}$/4$\pi$M$_{s}$는 각각 5.2~7.7 kG, 190~250 Oe, 0.4~O.74이었다. 반면, Fixed Q mode로 얻어진 박막의 $_{i}$H$_{c}$, 4$\pi$M$_{r}$/4$\pi$M$_{s}$는 각각 430~6290 Oe, 0.32~0.91로 훨씬 양호한 경자기 특성이 나타났다. 후자의 자기특성은 박막에 존재하는 입자(droplet)내 SmCo$_{5}$ 와 Sm$_2$Co$_{17}$상의 생성에 의한 것으로 판단된다. 입자의 존재로 인한 박막표면의 거칠기는 향후 연구에서 해결되어야 할 문제점으로 확인되었다.문제점으로 확인되었다.었다.

  • PDF

새로운 방식의 PFC Single Stage Full Bridge AC/DC Converter (New Single Stage PFC Full Bridge AC/DC Converter)

  • 임창섭;권순걸
    • 융합신호처리학회논문지
    • /
    • 제3권3호
    • /
    • pp.70-75
    • /
    • 2002
  • 본 논문은 새로운 단일 전력단 역률보상 풀 브리지 컨버터를 제안하였다. 제안된 컨버터는 역률보상을 위하여 앞단에 2개의 인덕터, 2개의 다이오드, 2개의 자성결합 변압기를 가진 2VS 풀브리지 DC/DC 컨버터로 구성되어 있다. 이러한 구성방법에 의해 전력은 전원에서 분리되고, 안정된 직류출력전압을 얻을 수 있다. 이 토폴로지에서 주소자의 전압스트레스는 영전압스위칭에 의해서 감소되며, 또한 제안된 컨버터는 능동 역률보정 스위치와 제어 및 게이팅 보드와 같은 보조회로가 필요치 않게되어 규격과 단가를 낮출 수 있을 뿐 아니라 효율을 증가시킬 수 있다.

  • PDF

연소가스내 탈황탈질처리를 위한 저온 플라즈마 기술 (Non-Thermal Plasma Technique for Removing $SO_2$ and $NO_x$ from Combustion Flue Gas)

  • 송영훈;신완호;김석준;장길홍
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1997년도 제15회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.69-76
    • /
    • 1997
  • Industrial-scale pulse corona process to remove $SO_2$ and $NO_x$ simultaneously from combustion flue gas has been studied. The pilot plant built in the present study treats 2,000 $Nm^3$/hr of flue gas from a boiler. The geometry of the pulse corona reactor is similar to that of an electrostatic precipitator commonly used in industry, A thyratron switch and magnetic pulse compressors, which can generate up to 130 kV of peak pulse voltage and up to 30 kW of average pulse power, have been used to produce pulsed corona. The removal efficiencies of $S0_2$ and $NO_x$ with the present process are maximum of 95 % and 85 %, respectively. Electrical power consumption to produce the pulsed corona, which has been one of the major difficulties to apply this process to industry, has been evaluated in the present study. The results showed that the power consumption can be reduced significantly by simultaneous addition of hydrocarbon injection and heterogeneous phase reactions to the process.

  • PDF