• 제목/요약/키워드: magnetic relaxation

검색결과 276건 처리시간 0.025초

Proton Magnetic Resonance Study of the Amino Group of Thioacetamide (TA) I. Quadrupole Relaxation Effects in NH$_2$ of Thioacetamide

  • Suhr, Jae-Ryun;Yoon, Chang-Ju;Ro, Seong-Gu;Choi, Young-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제8권4호
    • /
    • pp.230-232
    • /
    • 1987
  • Nitrogen-14 quadrupolar relaxation has been observed in the amino proton nmr spectra of TA in acetone and methanol solutions over the temperature range $-83^{\circ}C\; to\;+35^{\circ}C.$ The proton nmr lineshapes were analyzed to yield a $^{14}N$ spin lattice relaxation time $(T_1)_N$ as a function of temperature. Activation energies and correlation times at $25^{\circ}C$ for the molecular reorientation in the two solution phases have been calculated and the results are discussed.

NMR을 이용한 구조 및 입도 차이에 따른 분말 포도당의 molecular relaxation behavior의 관찰 (Observation of Molecular Relaxation Behavior of Glucose Powders with Different Structures and Particle Sizes Using Low Field Nuclear Magnetic Resonance (NMR))

  • 정명수
    • 한국식품과학회지
    • /
    • 제34권6호
    • /
    • pp.1140-1144
    • /
    • 2002
  • 제조방법이 서로 다른 3가지 종류의 분말포도당을 표준체를 사용하여 입자크기별로 분류하여 각 시료에 대한 온도 변화에 따른 relaxation behavior, 즉 molecular mobility의 변화를 관찰하기 위하여 low resolution pulsed NMR로 각 온도에서 spin-spin relaxation time constant$(T_2)$을 측정하였다. 분말포도당 종류별로 $T_2-$온도 곡선을 작성하여 입도의 변화에 따른 각 시료의 glass transition 특성을 비교, 분석하였다. 또한 주사전자현미경으로 각 시료의 미세구조를 관찰함으로써 구조적 차이가 제조방법 및 입도의 변화에 따른 분말포도당의 relaxation behavior의 변화에 어떤 영향을 미치는지 조사하였다. 무수결정포도당은 본 연구에서의 측정 온도범위에서 입도에 관계없이 molecular mobility에 대한 측정값인 $T_2$의 변화가 거의 없는 것으로 나타나 온도변화에 매우 안정한 결정구조를 가진다는 사실을 확인할 수 있었다. 반면에 함수결정포도당은 결정구조를 가지지만 화학구조상 물분자를 함유하기 때문에 어느 온도$(65{\sim}70^{\circ}C$ 부근) 이상이 되면 결정구조가 깨어지면서 급격하게 caking이 시작되는 경향을 보여주었고, 무정형 구조를 가지는 정제포도당은 구조적 특성상 함수결정포도당보다 낮은 온도$40^{\circ}C$ 부근)에서부터 molecular mobility의 변화가 관찰되는 caking에 매우 민감한 물질임을 알 수 있었다. 입자크기의 차이는 제조방법의 차이에 비해 분말포도당의 molecular relaxation behavior에 그다지 큰 영향을 미치지는 않지만 입도가 커질수록 입자간의 접촉표면적이 줄어들어 caking에 대한 안정성이 다소 향상될 수 있음을 알 수 있었다..92에서 총 3개의 peak가 검출되었고, 이때의 검출파장은 약 $380{\sim}490\;nm$ 사이의 파장으로서 gradient mode로 한 이동상의 조건과 일치하였다. 또한 RT값이 3.27의 peak에서 가장 많은 색소가 검출되었다. 그러나 gradient mode로 한 이동상의 조건에서 7개의 peak가 검출되었고 isocratic mode로 한 이동상의 조건에서는 3개의 peak가 검출된 것으로 보아 정성적으로는 gradient mode로 한 이동상의 조건이 더 적합한 것으로 사료된다. 또한, PDA-HPLC를 이용한 참조기와 수조기의 색소성분을 비교한 결과, 수조기와 참조기에서 검출되는 peak중 각각의 3개의 peak는 유사한 RT값을 보였으나, 참조기 및 수조기의 각각 1개의 peak는 서로 다른 RT값을 보였으며 참조기 성분의 peak중 RT = 31.02는 수조기 성분에서는 발견되지 않아, 이 성분은 참조기 성분과 연관성이 클 것으로 사료된다.ne 함량은 일반꽃포류와 구운꽃포류에서 각각 $4{\sim}43\;mg$$18{\sim}74\;mg$이었다. t-검정 결과 일반꽃포류와 구운꽃포류 함량간에는 수분, glutamic acid, creatinine 등에서 유의차가 있었으나, 그 이외에 대부분의 성분간에는 유의차가 인정되지 않는 것으로 나타났다.갈근 추출액을 급여한 흰쥐군은 50 ppm의 카드뮴액만을 급여한 흰쥐군과 비교하여 신장내 카드뮴 함량과 GPT 및 LDH 활성도, renin 활성도가 유의적으로 감소되었고 신장 무게는 정상 흰쥐와 같은 수준으로 회복하였고 GOT 활성도 역시 정상 흰쥐와 같은 수준으로 감소를 보여 갈근이 카드뮴 중독 흰쥐에서 신장 등의 장기내 카드뮴 축적의 감소로 카드뮴 중독 작용의 경감 효과를 갖는 것으로 나타났다.실이나 최근 세계화는 곧 우리의 전통문화를 알리는 것이라는 목소리에 주부들이 전통음식에 대한

3.0T MRI에서 온도변화가 T1 및 T2 이완시간에 미치는 영향 (Effect of Temperature on T1 and T2 Relaxation Time in 3.0T MRI)

  • 김호현;권순용;임우택;강충환;김경수;김순배;백문영
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.63-68
    • /
    • 2013
  • Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials' temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to $45^{\circ}C$. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were $214.39{\pm}0.25$, $236.02{\pm}0.87$, $267.47{\pm}0.48$, $299.44{\pm}0.64$, $330.19{\pm}1.72$ ms. T2 relaxation times were $180.17{\pm}0.27$, $197.17{\pm}0.44$, $217.92{\pm}0.39$, $239.89{\pm}0.53$, $257.40{\pm}1.77$ ms. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p< 0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature's differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.

  • PDF

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

Measuring T1 contrast in ex-vivo prostate tissue at the Earth's magnetic field

  • Oh, Sangwon;Han, Jae Ho;Kwon, Ji Eun;Shim, Jeong Hyun;Lee, Seong-Joo;Hwang, Seong-Min;Hilschenz, Ingo;Kim, Kiwoong
    • 한국자기공명학회논문지
    • /
    • 제23권1호
    • /
    • pp.12-19
    • /
    • 2019
  • A former study has shown that the spin-lattice relaxation time ($T_1$) in cancerous prostate tissue had enhanced contrast at an ultra-low magnetic field, $132{\mu}T$. To study the field dependence and the origin of the contrast we measured $T_1$ in pairs of ex-vivo prostate tissues at the Earth's magnetic field. A portable and coil-based nuclear magnetic resonance (NMR) system was adopted for $T_1$ measurements at $40{\mu}T$. The $T_1$ contrast, ${\delta}=1-T_1$ (more cancer)/$T_1$(less cancer), was calculated from each pair. Additionally, we performed pathological examinations such as Gleason's score, cell proliferation index, and micro-vessel density (MVD), to quantify correlations between the pathological parameters and $T_1$ of the cancerous prostate tissues.

$Fe_{80}B_{12}Si_8$ 비정질 합금의 자구 및 자왜와 자기적 성질에 미치는 Mo 첨가와 자장 열처리 효과 (The effect of Mo addion and Magnetic field annealing on the magnetic properties, Magnetostriction and Domain structures of $Fe_{80}B_{12}Si_8$ amorphous alloy.)

  • 고창진;강계명;송진태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1989년도 춘계학술대회 논문집
    • /
    • pp.49-51
    • /
    • 1989
  • The effect of Mo elenent and annealing condition on the magnetic properties were investigated in Fe$_{80}$B$_{12}$Si$_{8}$ amorphous alloy. With increasing Mo contents, soft magnetic properties were improved by decreasing coercive force and increasing maximum permeability. These improvements were attributed to the decreasing of magnetostriction by Mo addition. The annealing treatment also improved the soft magnetic properties of (Fe$_{1-x}$ Mo$_{x}$)$_{80}$ B$_{12}$ Si$_{8}$ amorphous alloys. It could be thought that these improvements were ascribed to the relaxation of internal stress.nal stress.ess.

  • PDF

Nonlinear effects in solution NMR: A numerical study on dynamics of dipolar demagnetizing field and radiation damping

  • Sangdoo Ahn;Lee, Sanghyuk
    • 한국자기공명학회논문지
    • /
    • 제3권2호
    • /
    • pp.71-83
    • /
    • 1999
  • The dynamics of the dipolar demagnetizing field is investigated by numerical simulation. The effects of radiation damping, molecular diffusion, and relaxation processes on the dipolar demagnetizing field are examined in terms of the modulation pattern of the z-magnetization and the signal intensity variation. Simulations for multi-components suggest applications for sensitivity enhancement in favorable conditions.

  • PDF

Modelling of magneto-thermoelastic plane waves at the interface of two prestressed solid half-spaces without energy dissipation

  • Kakar, Rajneesh;Kakar, Shikha
    • Earthquakes and Structures
    • /
    • 제8권6호
    • /
    • pp.1299-1323
    • /
    • 2015
  • A model for reflection and refraction of magneto-thermoelastic SV-waves at the interface of two transversely isotropic and homogeneous solid half spaces under initial stress by applying classical dynamical theory of thermoelasticity is purposed. The reflection and refraction coefficients of SV-waves are obtained with ideal boundary conditions for SV-wave incident on the solid-solid interface. The effects of magnetic field, temperature and initial stress on the amplitude ratios after numerical computations are shown graphically with MATLAB software for the particular model.

NMR Tools to Decipher Dynamic Structure of RNA

  • Lee, Janghyun;Choi, Byong-Seok
    • 한국자기공명학회논문지
    • /
    • 제21권2호
    • /
    • pp.55-62
    • /
    • 2017
  • It is now well established that RNAs exhibit fundamental roles in regulating cellular processes. Many of these RNAs do not exist in a single conformation. Rather, they undergo dynamic transitions among many different conformations to mediate critical interactions with other biomolecules such as proteins, RNAs, DNAs, or small molecules. Here, we briefly review NMR techniques that describe the dynamic behavior of RNA by determining structural, kinetic, and thermodynamic properties.