• Title/Summary/Keyword: mSv

Search Result 571, Processing Time 0.031 seconds

A Study on the Evaluation of Surface Dose Rate of New Disposal Containers Though the Activation Evaluation of Bio-Shield Concrete Waste From Kori Unit 1

  • Kang, Gi-Woong;Kim, Rin-Ah;Do, Ho-Seok;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.1
    • /
    • pp.133-140
    • /
    • 2021
  • This study evaluates the radioactivity of concrete waste that occurs due to large amounts of decommissioned nuclear wastes and then determines the surface dose rate when the waste is packaged in a disposal container. The radiation assessment was conducted under the presumption that impurities included in the bio-shielded concrete contain the highest amount of radioactivity among all the concrete wastes. Neutron flux was applied using the simplified model approach in a sample containing the most Co and Eu impurities, and a maximum of 9.8×104 Bq·g-1 60Co and 2.63×105 Bq·g-1 152Eu was determined. Subsequently, the surface dose rate of the container was measured assuming that the bio-shield concrete waste would be packaged in a newly developed disposal container. Results showed that most of the concrete wastes with a depth of 20 cm or higher from the concrete surface was found to have less than 1.8 mSv·hr-1 in the surface dose of the new-type disposal container. Hence, when bio-shielded concrete wastes, having the highest radioactivity, is disposed in the new disposal container, it satisfies the limit of the surface dose rate (i.e., 2 mSv·hr-1) as per global standards.

Evaluation of dose received by workers while repairing a failed spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.442-448
    • /
    • 2022
  • Intermediate-level radioactive waste (ILW) is not subject to legal approval for cave disposal in Korea. To solve this problem, a spent resin treatment device that separates 14C-containing resin from zeolite/activated carbon and desorbs 14C through a microwave device has been developed. In this study, we evaluated the radiological safety of the operators performing repair work in the event of a failure in such a device treating 1 ton of spent resin mixture per day. Based on the safety evaluation results, it is possible to formulate a design plan that can ensure the safety of workers while developing a commercialized device. When each component of the resin treatment device can be repaired from the outside, the maximum and minimum allowable repair times are calculated as 263.2 h and 27.7 h for the 14C-detached resin storage tank and zeolite/activated carbon storage tank, respectively. For at least 6 h per quarter, the worker's annual dose limit remains within 50 mSv/year; further, over 5 years, it remained within 100 mSv. At least 6 h of repair time per quarter is considered, under conservative conditions, to verify the radiological safety of the worker during repair work within that time.

Application of activated carbon induced ballasted flocculation for improving activated sludge settleability (활성슬러지 침전성 향상을 위한 활성탄 가중응집제 적용 연구)

  • Kim, Yongbum;Yang, Hyeji;Choi, Younggun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.153-162
    • /
    • 2021
  • The effects of activated carbon originated Ballasted Flocculant (BF) on the settleability of activated sludge and the recovery of BF by Hydro-cyclone (HC) were analyzed experimentally. Two kinds of BF (M-I: 125-250 ㎛, M-II: 250-425 ㎛ in dia.) and three kinds of activated sludges with different SS concentration (2,300-7,100 mg/L) were applied for this study. With the dosage variation of BF from 0.14 to 1.3 g-BF/g-SS, we could obtain 24-31% improvement in SV30 (Sludge Volume after 30min sedimentation) for the lowest SS concentration sludge (2,300 mg/L). Whereas the SV30 improvement was much higher as 44-48% for the highest SS concentration sludge (7,100 mg/L). The settling characteristics of the sludge with BF followed Vesilind model the best among three models (Vesilind, Takacs and Cho model). HC could effectively separate BF with the separation efficiency of 70-90% and over 95% separation efficiency could be obtained when the HC was applied twice.

Planning and decommissioning of a disused Theratron- 780 teletherapy machine and the dose assessment methodology for normal and radiological emergency conditions

  • Mohamed M.Elsayed Breky ;Muhammad S. Mansy;A.A. El-Sadek ;Yousif M. Mousa ;Yasser T. Mohamed
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.238-247
    • /
    • 2023
  • The present work represents a technical guideline for decommissioning a disused teletherapy machine model Theratron-780 and contains category one 60Co radioactive source. The first section predicts the dose rate from the source in case of normal and radiological emergency situations via FLUKA-MC simulation code. Moreover, the dose assessment for the occupational during the whole process is calculated and compared to the measured values. A suggested cordoned area for safety and security in a radiological emergency is simulated. The second section lists the whole process's technical procedures, including (preview, dismantle, securing, transport and storage) of the disused teletherapy machine. Results show that the maximum obtained accumulated dose for occupational were found to be 24.5 ± 4.9 μSv in the dismantle and securing process in addition to 3.5 ± 1.8 μSv during loading on the transport vehicle and unloading at the storage facility. It was found that the measured accumulated dose for workers is in good agreement with the estimated one by uncertainty not exceeding 5% in normal operating conditions.

Radiation Exposure Dose of Handlers Using 18F-FDG in Small Animal Image Acquisition Experiments

  • Ik Soo Kim;Sun Young Yoon;Hwa Yeon Yeo
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.233-238
    • /
    • 2023
  • This study was conducted to confirm the safety of the operator's radiation exposure in the micro PET-CT image acquisition experiment using the 18F-FDG. The usage of 18F-FDG and the exposure dose of handlers were measured at University B in Metropolitan City A, which uses 18F-FDG for micro PET-CT image acquisition. As a result of the measurement, the exposure dose is far below the effective dose limit of radiation workers, 50 mSv per year, and the equivalent dose limit of 500 mSv per year for hands, feet, and skin. has been measured Since these exposure doses can be further increased according to the number of times of use of 18F-FDG, it is judged that the exposure dose compared to the handling amount of 18F-FDG shown in this study can be used as reference data. In addition, as changed environments such as the use of materials other than unopened RI are occurring in education and research environments, such as the use of 18F-FDG at University B, radiation exposure with more interest in safety management by checking the factors of radiation exposure of the handler concerned We will always do our best to reduce it.

Magnetic Sensitivity Depending on Width of IrMn Spin Valve Film Device (IrMn 스핀밸브 박막소자의 폭 크기에 의존하는 자장감응도)

  • Choi, Jong-Gu;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.41-44
    • /
    • 2010
  • The Cu thickness dependence of magnetic sensitivity for the NiFe/Cu/NiFe/IrMn spin valve multilayer was investigated. The magnetic properties measured by minor MR curves for the Ta(5 nm)/NiFe(8 nm)/Cu(3.5 nm)/NiFe(4 nm)/IrMn(8 nm)/Ta(2.5 nm) multilayer is MR = 1.46 %, MS = 2.0 %/Oe, $H_c\;=\;2.6\;Oe$, and $H_{int}\;=\;0.1\;Oe$. The magnetic sensitivities of GMR-SV devices with ten different widths and a same length of $4.45\;{\mu}m$ by fabricated by photo lithography decreased from 0.3 %/Oe to 0.06%/Oe as from a width of $10\;{\mu}m$ to $1\;{\mu}m$.

Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.450-461
    • /
    • 2020
  • Objective: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters. Materials and Methods: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods. Results: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (-5.7 to 11.8 mL), 3.6 mL (-4.0 to 11.2 mL), -0.4 mL (5.7 to 5.0 mL), and -1.8% (-5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87-0.93). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA. Conclusion: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.

Effect of Medetomidine and Combination of Medetomidine/tiletamine/zolazepam and Medetomidine/tiletamine/zolazepam/tramadol on Echocardiographic Cardiac Contractility in Dogs (개에서 Medetomidine, Medetomidine/tiletamine/zolazepam 합제, Medetomidine/tiletamine/zolazepam/tramadol 합제가 심장초음파 상 심장 수축력에 미치는 영향)

  • Suh, Sang-IL;Kim, Tae-Jun;Lee, Eun-Chan;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.32 no.5
    • /
    • pp.422-425
    • /
    • 2015
  • This study evaluated the myocardial performance on echocardiography after the sedation/anesthesia of medetomidine (D), the combination of medetomidine and tiletamine/zolazepam (DZ), and the combination of medetomidine, tiletamine/zolazepam and tramadol (DZT) in Beagle dogs. Ten healthy adult Beagle dogs (weighing $8.6{\pm}1.0kg$) were enrolled in this study. Heart rate (HR), fractional shortening (%FS), left ventricular ejection fraction (%LVEF), stroke volume (SV), cardiac output (CO), left ventricular internal diameter in systole (LVIDs) and left ventricular internal diameter in diastole (LVIDd) using M-mode echocardiography were measured prior to anesthesia, then every 10 min for 60 min. The HR, %FS, %LVEF, SV and CO were significantly decreased during sedation/anesthesia with D, DZ and DZT combination of anesthesia. Although those anesthetic protocols provided acceptable quality of sedation/anesthesia, levels of cardiovascular suppression were substantial and persistent and thus the continuous monitoring on vital signs should be accompanied in any situation. Close attention is required for dogs with pre-existing heart diseases, when those anesthetic protocols were applied.

Development of Mixed Sensor Parts for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 혼합형 센서부 개발)

  • Kim, Jae-Hyeong;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1457-1460
    • /
    • 2019
  • In this paper, we proposed the development of a mixed sensor parts for integrated radiation exposure protection fireman's life-saving alarm that can be location-tracked and irradiated. To measure radiation exposure dose, we use the PIN-Diode radiation measurement sensor module, a semi-conductive radiation measurement sensor that can minimize size and weight. The design for removing leakage current is carried out to enhance the characteristics of the radiation measurement sensor using PIN-Diode. The IMU sensor module is used to estimate the location of the current fireman at the same time as the accident estimate by adding together the data and the values for acceleration on the three axis. Experiments were conductied by an authorized testing agency to determine the efficiency of the proposed mixed sensor parts for integrated radiation exposure protection fireman's life-saving alarms. The cumulative dose measurement range was measured in the range of 10 μSv to 10 mSv, the highest level in the world. The accuracy was measured from ±6.3% to ±9.0% (137 Cs) and normal operation was found at the international standard of ±15%. In addition, positional accuracy was measured within ±10%, resulting in a high level of results, demonstrating its effectiveness. Therefore, it is expected that more firemen will be able to provide with superior performance integrated radiation exposure protection fireman life-saving alarm.

The Study on the Dilution Time of Radioactive Tracer in Estradiol Measurement (방사성 요오드 치료 후, 퇴원 선량 측정에 있어 각국의 기준 및 권고 비교)

  • Lee, Seung Jae;Seo, Soo Hyun;Lee, Sung Ha;Park, Yong Sung;Oh, Ki Baek;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.49-54
    • /
    • 2017
  • Purpose The high-dose administration of I-131 has been standing for the basic therapy method of thyroid cancer. In korea, it is not necessary for patients to be hospitalized if the administration dose are under 1.2 GBq. However, if the dose are over 1.2 GBq, the patients should be stay in special ward with radiation shield. In such cases, the radioactivity level upon release should be under a dose of $70{\mu}Sv/hr$ at a distance of approx. 1m. This regulation bring the patients to stay for about 2 to 3 days in ward before the release. Materials and Methods Using the inpatients' release data of severance hospital, an inpatient-days were retrospectively calculated and compared with practical data and estimate the inpatient-days with the conditions of korea ($70{\mu}Sv/hr$), Japan ($30{\mu}Sv/hr$), germany ($3.5{\mu}Sv/hr$ at a distance of approx. 2 m), and other european countries. Results When a effective half-life of 15.4 was used, the expected inpatient-days were calculated as 2.15 days in the condition of Japanese regulation and 1.37 days in the condition of korean regulation. The practical inpatient-days of patients in Severance hospital were 1.32 days. Conclusion As ICRP 94 has been mentioned that the release of patients administrated with I-131 for the therapy should be carefully considered because each patients has different thyroid uptake rate and their conditions with family members after the release from the ward. Nonetheless, efforts to bring more aquate data which is for getting closer to the practical data should be continuously studied.

  • PDF