• Title/Summary/Keyword: mSv

Search Result 571, Processing Time 0.026 seconds

Application of Earthworm Casting-derived Biofilter Media for Hydrogen Sulfide Removal (지렁이 분변토를 이용한 생물담체가 충전된 바이오필터에 의한 황화수소 제거)

  • Yoo, Sun-Kyoung;Lee, Eun-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.820-825
    • /
    • 2007
  • Earthworm casting was the natural fertilizer that contained high concentrations of nutrients such as nitrogen, phosphate and potassium and of over $10^8$ CFU/ml of microorganisms. Greater than 80% of feed was excreted through the fermentation by the intestinal enzyme, after worm had eaten feeds such as fallen leaves and rotten roots under the ground. Also, the soil structure of casting was known to be very efficient in the aspects of the porosity, the water permeability, and deodorizing activities. In this research, the biofilter packed with a biomedia made of casting and waste polyurethane foam, a binder, which helped to improve the durability and perpetuity of casting, was investigated to degrade malodorous hydrogen sulfide gas. The biomedia had no need of extra supply of nutrients and of microbial inoculations. On the beginning of the operations, it showed 100% removal of hydrogen sulfide gas without lag phase. At SV of 50 $h^{-1}$, hydrogen sulfide gas from the outlet of the biofilter was not detected, when inlet concentration increased to 450 ppmv. After that, removal efficiency decreased as increasing inlet hydrogen sulfide concentration. Hydrogen sulfide removal was maintained at almost 93% until inlet concentration was increased up to 950 ppmv, at which the elimination capacity of $H_2S$ was 61.2 g $S{\cdot}m^{-3}{\cdot}h^{-1}$. Maximum elimination capacity guaranteing 90% removal was 61.2, 65.9, 84.7, 89.4 g $S{\cdot}m^{-3}{\cdot}h^{-1}$ at SV ranging from 50 $h^{-1}$ to 300 $h^{-1}$, but was 59.3 g $S{\cdot}m^{-3}{\cdot}h^{-1}$ at SV of 400 $h^{-1}$. The results calculated from Michaelis-Menten equation revealed that $V_m$ increased from 66.04, 88.96, 117.35, 224.15, to 227.54 g $S{\cdot}m^{-3}{\cdot}h^{-1}$ with increasing space velocity in the range of 50 $h^{-1}$ to 400 $h^{-1}$. However, saturation constant$(K_s)$ decreased from 79.97 ppmv to 64.95 and 65.37 ppmv, and then increased to 127.72 and 157.43 ppmv.

Evaluation of Radon Levels in Various Public-acess Buildings or Underground Facilities, and Their Temporal Variation in Underground Facilities (다중 이용 건물 또는 지하 실내 공간의 용도에 따른 라돈 오염도 비교와 지하 공간의 시간대별 라돈 농도 변화)

  • Choi, Im-Cho;Shin, Seung-Ho;Jo, Wan-Kuen
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.203-211
    • /
    • 2009
  • A lesser degree of research is available with respect to indoor radon characteristics associated with occupants' exposure. The present study evaluated the radon levels in several public-access buildings or underground facilities, and their temporal variation in underground facilities. Radon measurements were conducted in 2005 and 2006, utilizing a continuous radon detector. A solid alpha detector (RAD7) was utilized to measure indoor radon levels. The mean radon concentrations obtained from the building or facilities were in a descending order: platforms of Daegu subway line 2, 2005 (32 $Bq/m^3$), hot-air bathroom (14 $Bq/m^3$), basement of office building (14 $Bq/m^3$), underground parking garage (14 $Bq/m^3$), underground shop (12 $Bq/m^3$), nursery (10 $Bq/m^3$), platforms of Daegu subway line 2, 2006 (9.0 $Bq/m^3$), platforms of Daegu subway line 1, 2006 (8.9 $Bq/m^3$), supermarket (7.9 $Bq/m^3$), hospital (7.3 $Bq/m^3$), and second-floor of office building (5.7 $Bq/m^3$). In general, underground-level facilities exhibited higher radon levels as compared with ground-level facilities. It was suggested that ventilation is an important parameter regarding the indoor levels of a subway. There was a decreasing or increasing trend in hourly-radon levels in a subway, whereas no trend were observed in a basement of office building. In addition, the radon levels in the subway lines 1 and 2 varied according to the platforms. The radon levels in the present study were much lower than those of previous studies. The average annual effective dose (AED) of radiation from indoor radon exposure was estimated to be between 0.043 and 0.242 mSv/yr, depending on facility types. These AEDs were substantially lower than the worldwide average AED (2.4 mSv/yr).

Effectiveness of the neutron-shield nanocomposites for a dual-purpose cask of Bushehr's Water-Water Energetic Reactor (VVER) 1000 nuclear-power-plant spent fuels

  • Rezaeian, Mahdi;Kamali, Jamshid;Ahmadi, Seyed Javad;Kiani, Mohammad Amin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1563-1570
    • /
    • 2017
  • In order to perform dry interim storage and transportation of the spent-fuel assemblies of the Bushehr Nuclear Power Plant, dual-purpose casks can be utilized. The effectiveness of different neutron-shield materials for the dual-purpose cask was analyzed through a set of calculations carried out using the Monte Carlo N-Particle (MCNP) code. The dose rate for the dual-purpose cask utilizing the recently developed materials of $epoxy/clay/B_4C$ and $epoxy/clay/B_4C/carbon$ fiber was less than the allowable radiation level of 2 mSv/h at any point and 0.1 mSv/h at 2 m from the external surface of the cask. By utilization of $epoxy/clay/B_4C$ instead of an ethylene glycol/water mixture, the dose rates on the side surface of the cask due to neutron sources and consequent secondary gamma rays will be reduced by 17.5% and 10%, respectively. The overall dose rate in this case will be reduced by 11%.

Possible Biomarker Gene for Radiation Workers in Hospital

  • Jin, Young-Woo;Jeong, Mee-Seon;Moon, Kien;Lee, Chee-Young;Bae, Sang-Woo;Choi, Soo-Yong;Lee, Yun-Sil
    • Molecular & Cellular Toxicology
    • /
    • v.5 no.2
    • /
    • pp.165-171
    • /
    • 2009
  • Biomarkers indicating past exposure to radiation have not yet been entirely satisfactory. In this study, we validated several genes reported as radiation response genes, as biomarkers to detect past exposure to radiation in occupationally exposed workers, especially workers in the medical field. A total of 54 radiation workers in hospital were investigated for radiation exposure dose. Their average radiation dose of recent one year was 1.09 mSv ($\pm$1.63) with a 10.63 mSv ($\pm$12.91) cumulative dose. The results of the multiple regression analysis for the various variables indicate that the Hsc70 (P=0.0292) and ORAL (P=0.0045) may be candidate biomarkers for the recent 1 year radiation exposure in radiation workers, whereas AEN (P=0.0334) and PGAMI (P=0.0003) might be for cumulative exposure.

Seasonal and Interannual Variability of the North Korean Cold Current in the East Sea Reanalysis Data (동해 재분석 자료에 나타난 북한한류의 계절 및 경년변동성)

  • Kim, Young-Ho;Min, Hong-Sik
    • Ocean and Polar Research
    • /
    • v.30 no.1
    • /
    • pp.21-31
    • /
    • 2008
  • Analyzing the results of East Sea Regional Ocean Model using a 3-dimensional variational data assimilation scheme, we investigated spatial and temporal variability of the North Korean Cold Current (NKCC) in the East Sea. The climatological monthly mean transport of the NKCC clearly shows seasonal variation of the NKCC within the range of about 0.35 Sv ($=0^6m^3/s$), which increases from its minimum (about 0.45 Sv) through December-January to March, decreases during March and May, and then increases again to the maximum (about 0.8 Sv) in August-September. The volume transport of the NKCC shows interannual variation of the NKCC with the range of about 1.0 Sv that is larger than seasonal variation. The southward current of the NKCC appears often not only in summer but in winter as well. The width of the NKCC is about 35 km near the Korean coast and its core is located under the East Korea Warm Current. The North Korean Cold Water (NKCW), characterized by low salinity and low temperature, is located both under the Tsushima Warm Water and in the western side of the maximum southward current of the NKCC that means the NKCC advects the NKCW southward along the Korean coast. It is revealed that the intermediate low salinity water, formed off the Vladivostok in winter, flows southward to the south of $37^{\circ}N$ through $2{\sim}3$ paths; one path along the Korean coast, another one along $132^{\circ}E$, and the middle path along $130^{\circ}E$. The path of the intermediate low salinity varies with years. The reanalysis fields suggest that the NKCW is advected through the paths along the Korean coast and along $130^{\circ}E$.

Detection Limit of a NaI(Tl) Survey Meter to Measure 131I Accumulation in Thyroid Glands of Children after a Nuclear Power Plant Accident

  • Takahiro Kitajima;Michiaki Kai
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.131-143
    • /
    • 2023
  • Background: This study examined the detection limit of thyroid screening monitoring conducted at the time of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in 2011 using a Monte Carlo simulation. Materials and Methods: We calculated the detection limit of a NaI(Tl) survey meter to measure 131I accumulation in the thyroid gland of children. Mathematical phantoms of 1- and 5-year-old children were developed in the simulation of the Particle and Heavy Ion Transport code System code. Contamination of the body surface with eight radionuclides found after the FDNPP accident was assumed to have been deposited on the neck and shoulder area. Results and Discussion: The detection limit was calculated as a function of ambient dose rate. In the case of 40 Bq/cm2 contamination on the body surface of the neck, the present simulations showed that residual thyroid radioactivity corresponding to thyroid dose of 100 mSv can be detected within 21 days after intake at the ambient dose rate of 0.2 µSv/hr and within 11 days in the case of 2.0 µSv/hr. When a time constant of 10 seconds was used at the dose rate of 0.2 µSv/hr, the estimated survey meter output error was 5%. Evaluation of the effect of individual differences in the location of the thyroid gland confirmed that the measured value would decrease by approximately 6% for a height difference of ±1 cm and increase by approximately 65% for a depth of 1 cm. Conclusion: In the event of a nuclear disaster, simple measurements carried out using a NaI(Tl) scintillation survey meter remain effective for assessing 131I intake. However, it should be noted that the presence of short-half-life radioactive materials on the body surface affects the detection limit.

Magnetoresistive Properties of Array IrMn Spin Valves Devices (어레이 IrMn 스핀밸브 소자의 자기저항특성 연구)

  • Ahn, M.C.;Choi, S.D.;Joo, H.W.;Kim, G.W.;Hwang, D.G.;Rhee, J.R.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.156-161
    • /
    • 2007
  • To develop array magnetic sensors, specular-type giant magnetoresistive- spin valve (GMR-SV) film of Glass/Ta(5)MiFe(7)/IrMn(10)NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) was deposited by using a high-vacuum sputtering system. One of 15 way sensors in the area of $8{\times}8mm^2$ was Patterned a size of $20{\times}80{\mu}m^2$ in multilayer sample by Photo-lithography. All of 15 sensors with Cu electrodes were measured a uniform magnetic properties by 2-probe method. The highest magnetic sensitivity of MR and output voltage measured nearby an external magnetic field of 5 Oe were MS = 0.5%/Oe and ${\triangle}$V= 3.0 mV, respectively. An easy-axis of top-free layers of $CoFe/O_2/NiFe$ with shape anisotropy was perpendicular to one of bottom-pinned layers $IrMn/NiFe/O_2/CoFe$. When the sensing current increased from 1 mA to 10 mA, the output working voltage uniformly increased and the magnetic sensitivity was almost stable to use the nano-magnetic devices with good sensitive properties.

Accuracies of the Position Fixes by the Differential GPS measured in Pusan (부산에서의 Diferential GPS의 측위정도)

  • 이희상;신형일;김기윤;이대재
    • Journal of the Korean Institute of Navigation
    • /
    • v.17 no.3
    • /
    • pp.49-55
    • /
    • 1993
  • This study describes the accuracies of position fixes observed by the DGPS systems for the purpose of obtaining the utility basic data in the fishery and oceanography observation field. The circling sail experiments around a reterence point using the DGPS were made in water level point of National Fisheries University of Pusan and on the sea in Yongho day located on the southeast of that university. The main results are as follows ; 1) The number of the usable satellites in position fixing were all eighteen, SV 2, 3, 11-21, 23-26 and SV 28 etc. Each satellites could be observed for average seven hours a day, and position fixing was found to be always possible except about thirty minutes a day. 2) In the standard fixed position, the radius of 95% probability circle and the shifted distance between the position fixes by the DGPS and true position were respectively 5.7m, 0.9m. In the above case those of ordinary GPS was respectively 48.8, 54.2m. Therefore, the accuracy of the position fixes by DGPS was shown much higher the ordinary GPS. 3) At land, the shifted distance between the center of traces in the circling sail experiment of 15m ra-dius by DGPS and the reference position amounted to 5.5m and observed radius of circling traces was 17.5m. other than 15m. At sea, that distance the center of traces in circling experiment of 20m radius by the DGPS and the reference position amounted to 3.6m and observed radius of circling traces was 19.7m, other than 20m. Therefore, the utility of the circling experiment to obtain the accurate position fixes by the DGPS was found to be very high.

  • PDF

Development of Environmental Safety Real-Time Monitoring System by Living Area (생활권역별 환경안전 실시간 모니터링 시스템의 개발)

  • Lee, Joo-Hyun;Kim, Joo-Ho;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1088-1091
    • /
    • 2019
  • In this paper, a real-time monitoring system for environmental safety by living area is proposed. The proposed system is designed to measure radiation, fine dust and basic living information (temperature) using fixed and mobile measuring equipment, and constitutes a web database that stores data received from the equipment. It also develops web programs for displaying received data on PCs and mobile phones. The results of testing the performance of the system by an authorized testing agency showed that the radiation measurement range was measured in the range of $10{\mu}Sv/h$ to 10mSv/h, which is comparable to the world's highest level, and that the accuracy was measured between ${\pm}6.7$ and ${\pm}8.7$ percent of the measurement uncertainty was measured and normal operation at or below the international standard of ${\pm}15$ percent. In addition, the temperature test was conducted on a section of $-20^{\circ}C$ to $50^{\circ}C$ and normal operation was confirmed in response to the temperature change. Stability of radiated electromagnetic waves was ensured by a suitable judgment. The product's testing in general and high and low temperature environments for about four months after the prototype was made confirmed to be more than five years of durability. The measurement range and accuracy of fine dust sensors are compared with those of companies that measure the air environment, and the performance level is similar through the air quality measurement register.

Calculation of Derived Investigation Levels for Uranium Intake (우라늄 섭취의 유도조사준위 산출)

  • Lee, Na-Rae;Han, Seung-Jae;Cho, Kun-Woo;Jeong, Kyu-Hwan;Lee, Dong-Myung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.68-77
    • /
    • 2013
  • Derived Investigation levels(DILs) were calculated to protect the workers from the effects of both radiological hazard and chemical toxicity by uranium intake. Investigation Levels(ILs) of committed effective dose of 2 mSv $y^{-1}-6$ mSv $y^{-1}$ and uranium concentration of 0.3 ${\mu}g$ $g^{-1}$ in kidney, based on Korean Nuclaer Safety Act, Korean Occupational Safety and Health Act and current scientific studies of uranium intake were assumed. DILs of radiological hazard and chemical toxicity were then calculated based on the concentration of uranium in air of workplace, the lung monitoring and urine analysis, respectively. As a result, in case of the nuclear fuel fabrication plant where 3.5% enriched uranium is handled, derived investigation level(DIL) for the control of the concentration of uranium in the air of workplace assumed with 15-min acute inhalation was 0.6 mg $m^{-3}$ for all types of uranium. DILs for the control of the average concentration of uranium in air of workplace, assuming an 8-hour workday, were 15.21 ${\mu}g$ $m^{-3}$ of Type F uranium, 0.41-1.23 Bq $m^{-3}$ and 0.13-0.39 Bq $m^{-3}$ for Type M and Type S uranium, respectively. DILs for the lung monitoring assumed with a period of 6-month interval were 0.37-1.11 Bq and 0.39-1.17 Bq in acute and chronic inhalation for Type M, respectively and 0.30- 0.91 Bq and 0.19-0.57 Bq in acute and chronic inhalation for Type S, respectively. Since a detection limit of typical germanium detector for the measurement of 235U activity is 4 Bq, DILs calculated for the lung monitoring were not appropriate. DILs for urine analysis, for which an interval was assumed to be 1 month, were 14.57 ${\mu}g$ $L^{-1}$ based on chemical toxicity after acute inhalation. In addition, acute and chronic inhalation of Type M were calculated 2.85-8.58 ${\mu}g$ $L^{-1}$ and 1.09-3.27 ${\mu}g$ $L^{-1}$ based on the radiological hazard, respectively.