• 제목/요약/키워드: mSv

검색결과 561건 처리시간 0.022초

안전기능성 구명복에 적용된 재귀반사 종류별 및 LED 위치별 가시성능 평가 (Visibility Evaluation of Various Retroreflective Fabric Types and LED Position on Safety Life Jacket)

  • 강민영;이선희
    • 한국의류학회지
    • /
    • 제41권2호
    • /
    • pp.352-361
    • /
    • 2017
  • This study prepared 5 retroreflective fabrics of glass beads and colors of silver, gold and purple in order to characterize morphologies, luminance and illuminance properties. Retroreflective fabrics were prepared according to division and area by Samp.1 (Division 2, area $80cm^2$), Samp.2 (Division 2, area $60cm^2$), Samp.3(Division 3, area $60cm^2$), Samp.4 (Division 5, area $50cm^2$), and Samp.5 (Division 1, area $100cm^2$). The results of the morphologies indicate that the back side of retroreflective fabrics was the 3M-Sv, RF-Sv. The RF-Gd of the fabrics were woven fabrics and the SRF-Sv, SRF-Pp was knitting. The largest glass bead size was 3M-Sv and the smallest was SRF-Pp. RF-Sv was the thinnest and SRF-Sv, SRF-Pp were the thickest. The results of luminance properties indicated a tendency to decrease slightly as the number of divisions and area increased, except for Samp.2 to Samp.3. The result of illuminance properties tend to increase as the number of LED becomes greater than the number of divisions in the same area; in addition, the higher the luminance as a whole increases. The results show that it is preferable to use a silver-colored RF-Sv which has the highest luminance and physical properties when a retroreflective fabric is applied to clothes.

사용후핵연료 운반용기 방사선적 안전성평가에 관한 연구 (A Study on Radiation Safety Evaluation for Spent Fuel Transportation Cask)

  • 최영환;고재훈;이동규;정인수
    • 방사성폐기물학회지
    • /
    • 제17권4호
    • /
    • pp.375-387
    • /
    • 2019
  • 본 연구에서는 최근 개발중인 360 다발 장전용량의 중수로 사용후핵연료 운반용기에 대한 설계기준연료의 방사선원항 평가와 용기외부에서의 방사선량률 계산을 수행하였다. 그리고 국·내외 방사선적 안전성평가와 관련한 기술기준 부합여부를 판단하고 결과의 적합성을 제시하였다. 방사선원항으로 작용하는 설계기준연료 선정을 위해 월성원전에서 운영중인 운반 용기 및 두 가지 방식의 건식저장시설에 적용된 설계기준연료의 사양 및 특성을 조사하였다. 각 운반·저장 시스템 별 설계 기준연료의 연소도, 최소 냉각기간 및 중간저장시설로의 운반시점 등을 바탕으로 연소도 7,800 MWD/MTU와 최소 냉각기간 6년을 설계기준연료로 설정하였다. 설계기준연료의 방사선원항은 SCALE 전산코드의 ORIGEN-ARP모듈을 이용하여 평가하였다. 운반용기의 방사선차폐평가는 MCNP6 전산코드를 이용하였으며, 기술기준에서 요구하는 운반용기 외부에서의 방사선량률 평가를 정상 및 사고조건으로 구분하여 수행하였다. 방사선량률 평가결과, 정상운반조건의 운반용기 표면 및 운반용기 표면 2 m 이격지점에서 계산된 최대 방사선량률은 각각 0.330 mSv·h-1와 0.065 mSv·h-1로 도출되어 선량률 제한치인 2.0 mSv·h-1와 0.1 mSv·h-1를 모두 만족하는 결과를 도출하였다. 또한 운반사고조건하 운반용기 표면 1 m 지점에서의 최대 방사선량률은 0.321 mSv·h-1로서 기술기준인 10.0 mSv·h-1 미만으로 평가되어, 대용량 중수로 사용후핵연료 운반용기는 방사선적 안전성을 확보하는 것으로 나타났다.

GMR-SV 박막내 미크론 크기의 홀 형성을 이용한 교환결합세기와 보자력 특성연구 (Properties of Exchange Bias Coupling Field and Coercivity Using the Micron-size Holes Formation Inside GMR-SV Film)

  • 벌러르마;카지드마;황도근;이상석;이원형;이장로
    • 한국자기학회지
    • /
    • 제25권4호
    • /
    • pp.117-122
    • /
    • 2015
  • 고감도 바이오센서용 거대자기저항-스핀밸브(Giant magnetoresistance-spin valve; GMR-SV) 박막소자의 미세패턴 공정으로 인한 교환결합력과 보자력 약화 문제를 해결하고자 전자사이크로트론 공명(Electron Cyclotron Resonance) Ar-이온 밀링을 이용하여 GMR-SV 박막에 지름 $35{\mu}m$인 원형 모양의 홀(Hole)을 패턴닝 하였다. GMR-SV를 4-단자법으로 측정한 자기저항 곡선으로부터 홀 개수가 많아질수록 자기저항비와 자장감응도는 홀이 없을 때 측정된 초기값과 같은 값을 유지하였고, 교환결합세기와 보자력은 120 Oe에서 190 Oe, 10 Oe에서 41 Oe로 크게 향상되었다. 이러한 현상은 GMR-SV 박막내의 자화용이축과 같은 방향을 띄고 센싱 전류의 방향과 수직인 공간에 위치하는 용이 자구영역(Easy magnetic domain; EMD)의 역할에 기인하는 결과를 보여주었다. GMR-SV 바이오 소자 제작시 폭을 넓게 하고 소자내부에 홀의 개수를 증가시켜 발생하는 EMD 효과가 자기저항특성을 향상시킬 수 있었다.

심장혈관 중재적 시술의 시술자 피폭 선량에 관한 연구 (Comparison of Operator Radiation Exposure Dose undergoing Cardiac Angiography and Cardiac Intervention)

  • 김정수;권순무;정혜경;이봉기;류동열;권호석;조병렬
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.181-186
    • /
    • 2016
  • 심장혈관 조영술과 심장혈관 중재술은 심장혈관 질환을 치료하는 안전하고 효율적인 시술이다. 그러나 시술이 이루어지는 동안 환자와 시술자의 방사선 피폭에 대해서는 주의가 필요하다. 본 연구의 대상으로는 2015년 9월부터 2016년 1월 사이에 강원도 소재 한 대학병원의 심혈관센터에서 시행된 147명의 심장혈관 조영술(CA)과 심장혈관 중재술(CI)을 시행한 환자를 대상으로 시술자의 피폭선량을 평가하였다. CA만을 시행한 경우 시술자의 유효선량은 최소 0.39 uSv, 최대 30.6 uSv를 나타냈고 평균 유효선량은 4.11 uSv를 나타냈다. CI를 시행한 경우 유효선량은 최소 1.618 uSv, 최대 202.805 uSv를 나타냈고 평균 유효선량은 34.41 uSv를 나타냈다. 본 연구의 결과에서 갑상선 위치에서 측정된 선량을 머리가 받은 선량으로 대체할 경우 PCI에서 평균 받는 선량을 연평균 1000건의 시술을 시행한다고 할 경우 90 mSv/year 에 해당한다. 이를 2년 누적할 경우 눈의 제한선량인 150 mSv를 초과하는 수치이다. 심장혈관 중재적 시술은 의료 방사선의 피폭에 있어 CT 다음으로 큰 부분을 차지하고 있다. 따라서 시술이 시행되는 동안 환자와 시술자의 방사선 방어가 적절히 이루어질 수 있도록 하여야 하며 검사의 최적화와 정당성을 확보하여 안전한 검사가 될 수 있도록 해야 한다. 이를 위해 시술자에게는 적절한 교육이 이루어져야 하고 시술 중에는 개인방어 장비를 착용하여야 하며 모니터링을 통해 환자와 시술자의 피폭선량을 줄이는 노력이 필요하다.

Status of Radiation Dose and Radioactive Contamination due to the Fukushima Accident

  • Baba, Mamoru
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.133-140
    • /
    • 2016
  • Backgrounds: The accident at Fukushima Daiichi Nuclear Power Plant (NPP), March 2011, caused serious radioactive contamination over wide area in east Japan. Therefore, it is important to know the effect of the accident and the status of NPP. Materials and Methods: This paper provides a review on the status of radiation dose and radioactive contamination caused by the accident on the basis of publicized information. Results and Discussion: Monitoring of radiation dose and exposure dose of residents has been conducted extensively by the governments and various organizations. The effective dose of general residents due to the accident proved to be less than a mSv both for external and internal dose. The equivalent committed dose of thyroid was evaluated to be a few mSv in mean value and less than 50 mSv even for children. Monitoring of radioactivity concentration has been carried out on food ingredients, milk and tap water, and actual meal. These studies indicated the percentage of foods above the regulation standard was over 10% in 2011 but decreasing steadily with time. The internal dose due to foods proved to be tens of ${\mu}Sv$ and much less than that due to natural $^{40}K$ even in the Fukushima area and decreasing steadily, although high level concentration is still observed in wild plants, wild mushrooms, animals and some kind of fishes. Conclusion: According to extensive studies, not only the effect of the accident but also the pathway and countermeasures against radioactive contamination have been revealed, and they are applied very effectively for restoration of environment and reconstruction of the area.

이동형 치과 X선 발생장치의 공간선량 분포 (Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment)

  • 한경순;안성민
    • 치위생과학회지
    • /
    • 제15권3호
    • /
    • pp.254-258
    • /
    • 2015
  • 치과병의원에서 사용하고 있는 이동형 치과 X선 발생장치를 이용하여 두경부 마네킹에 X선을 조사할 때 주변의 공간선량을 측정하고, 동일한 방법으로 고정형 X선 발생장치에 적용하여 측정된 공간선량을 상호 비교하며, 더불어 기기 및 위치별 공간선량을 비교 분석한 결과는 다음과 같다. 이동형 X선 발생장치의 평균 공간선량은 $37.51{\mu}Sv$로 고정형 X선 발생장치의 $10.77{\mu}Sv$보다 매우 높았다(p<0.001). 이동형 X선 발생장치의 기기별 공간선량은 $17.77{\mu}Sv$부터 $68.90{\mu}Sv$까지 큰 차이를 나타냈다(p<0.05). 위치별로는 직전 위치가 $54.14{\mu}Sv$로 가장 높았고, 직우 위치가 $13.60{\mu}Sv$로 가장 낮았으며, 직좌와 직후 위치는 $42.12{\mu}Sv$, $40.18{\mu}Sv$로 유사하였다(p<0.01). 이상의 결과를 통해 이동용 치과 X선 발생장치는 이동 불가능한 환자만을 대상으로 제한적으로 시행하여야 하며, 반드시 환자와 술자 모두 납 방어복을 착용하여 방사선 피폭을 최소화해야 할 것이다.

Detection of Magnetic Nanoparticles and Fe-hemoglobin inside Red Blood Cells by Using a Highly Sensitive Spin Valve Device

  • Park, Sang-Hyun;Soh, Kwang-Sup;Hwang, Do-Guwn;Rhee, Jang-Roh;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.30-33
    • /
    • 2008
  • A highly sensitive, giant magnetoresistance-spin valve (GMR-SV) biosensing device with high linearity and very low hysteresis was fabricated by photolithography. The detection of magnetic nanoparticles and Fe-hemoglobin inside red blood cells using the GMR-SV biosensing device was investigated. When a sensing current of 1 mA was applied to the current electrode in the patterned active devices with an area of $2{\times}6{\mu}m^2$, the output signals were about 13.35 mV. The signal from even one drop of human blood and nanoparticles in distilled water was sufficient for their detection and analysis.

실내 체적과 라돈 농도와의 상관관계 연구 (A Study on the Correlation between the Volume of Indoor Space and the Measured Concentration of Indoor Radon)

  • 강성아;한동현;김종일
    • Journal of Radiation Protection and Research
    • /
    • 제32권3호
    • /
    • pp.97-104
    • /
    • 2007
  • 전주시에 소재한 아파트의 큰 방과 작은 방을 대상으로 실내 체적과 측정되는 라돈 농도와의 상관 관계를 분석하였다. 또한 실내의 라돈 농도를 측정하여 실내의 시간별 라돈 농도의 변화를 파악하고 이를 토대로 실내 라돈의 년간 피폭선량을 계산하였다. 본 연구를 위하여 각각 8개의 아파트 큰 방과 작은 방을 대상으로 라돈 농도를 측정하였으며, 큰 방의 평균 체적은 $31.59\;m^3$ 그리고 작은 방의 평균 체적은 $16.82\;m^3$이었다. 큰 방의 평균 라돈 농도는 $71.73\;Bq/m^3$, 작은 방의 평균 라돈 농도는 $108.51\;Bq/m^3$로 측정되어 실내 체적과 실내 라돈 농도는 반비례 관계로 나타났다. 밀폐된 실내 라돈 농도의 주 발생원이 건축자재임을 감안하여 건물 벽의 표면적을 체적으로 나누어 계측해 본 결과 표면적/체적의 비가 클수록 측정되는 실내 라돈 농도가 크게 나타났다. 실내 라돈 농도의 하루 중 시간에 따른 변화를 조사한 결과 오전 $8{\sim}10$시에 일 최고 농도($114.5\;Bq/m^3$)를 보였고, 오후 $2{\sim}4$시에 일 최저농도($67.7\;Bq/m^3$)를 나타냈으며, 하루 중 라돈 농도의 변화는 약 $46.8\;Bq/m^3$이었다. 8개 지점의 실내 라돈의 연간 피폭선량을 계산해 본 결과 0.3에서 2.16 mSv/yr사이로 나타나, 일부 아파트의 피폭선량이 국제방사선영향과학위원회(UNSCEAR)가 제시한 수치인 1.3 mSv/yr를 초과했다.

131I 방사성 동위원소 치료에 따른 피폭 선량 연구 (The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy)

  • 장보석;유승만
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.653-659
    • /
    • 2019
  • 본 연구는 고용량 $^{131}I$ 치료 후 방사선원이 된 퇴원 환자로부터 나오는 방사선 피폭에 관해 외부 선량률을 측정하고, 그에 따른 피폭선량을 예측하는 것이 목적이다. 200 mCi 이상 고용량 $^{131}I$ 치료를 받은 30명의 환자에서 구리링 3개를 이용하여 환자로부터 거리 및 방위각에 따른 선량평가를 시행하였다. 정확한 방사선 계측을 위하여 GM 계측기를 이용하여 2명의 측정자가 방위각 8 포인트와 거리 변화를 주며 계측하였다. 측정값을 기반으로 3가지 예측 시뮬레이션을 설정하여 불특정 다수 일반인에 대한 피폭선량을 계산하였다. 1m 높이에서 방위각에 따른 외부 선량률이 가장 높은 부위는 0도이다. 거리에 따른 선량률은 거리별 방위각의 선량률 평균값을 사용하였다. 거리에 따른 외부 선량률의 최고치는 50, 100, 150 cm에서 각각 $214{\pm}16.5$, $59{\pm}9.1{\mu}Sv/h$, $38{\pm}5.8{\mu}Sv/h$ 이다. 고용량 $^{131}I$ 치료 환자가 대중교통을 이용해서 5시간 이동할 때 반경 50 cm 지점의 옆좌석에 안은 불특정 일반인이 받을 수 있는 피폭선량은 1.14 mSv이다. 소변 통(urin bag)을 착용한 퇴원환자로부터 100 cm 거리에서 4일 동안 간병인이 받을 수 있는 최대 피폭선량은 6.5 mSv이다. 퇴원 환자 귀가로 인해 7일 동안 150 cm 거리에서 보호자가 받을 수 있는 최대 피폭선량은 1.08 mSv이다. 개발된 예측 모델링으로 불특정 $^{131}I$ 치료 환자의 주변 일반인에게 적용하였을 때 연간 선량 한도를 단시간에 초과하는 수준이었다. 따라서 본 연구를 통해 현행 고용량 $^{131}I$ 치료 환자의 퇴원 후 주변의 일반인의 방호체계의 합리적인 가이드라인을 제시하는 데 도움을 줄 수 있을 것으로 사료된다.

흉부 디지털토모영상의 기본모드 및 부가여과사용 시 환자선량과 화질비교 (Digital Tomosynthesis Imaging of the Chest : Comparison of Patient Exposure Dose and Image Quality between Default Setting and Use Additional Filter)

  • 김계선;안성민;김성철
    • 한국콘텐츠학회논문지
    • /
    • 제13권9호
    • /
    • pp.288-294
    • /
    • 2013
  • 흉부 디지털토모장치는 가장 발달한 촬영방법중의 하나이지만 일반 흉부촬영방법에 비해 환자의 피폭선량이 높다는 단점이 있다. 이런 이유 때문에 본 연구는 흉부 디지털토모영상에서 부가여과를 사용하여 환자선량을 저감시키는 방법을 검토하여 보았으며, 화질의 변화도 실험하였다. 그 결과 부가여과가 없는 장치의 기본상태에서 피부입사선량, 면적선량, 실효선량은 1.95 mGy, 17.66 $dGycm^2$, 0.133 mSv로, 부가여과사용시는 0.312 mGy, 2.27 $dGy.cm^2$, 0.052 mSv로 나타나 선량이 각 각 66.2%, 73.6%, 57.4%로 감소하였다. 화질에서 병소의 검출율은 중심부 미소병소 검출율(p < .001)을 제외한 나머지 주변부, 중심부병변 및 주변부 미소병소에서는 두 방법에서 큰 차이를 보이지 않았으며, 환자의 선량감소에는 큰 효과를 볼 수 있었다.