• Title/Summary/Keyword: luting

Search Result 136, Processing Time 0.019 seconds

THE EFFECT OF TEMPORARY CEMENT AND DESENSITIZER ON THE BOND STRENGTH OF LUTING CEMENTS (접착용 시멘트의 결합강도에 임시 접착제와 탈감작제가 미치는 영향)

  • Sun Se-Na;Yang Hong-So;Park Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.335-343
    • /
    • 2002
  • This study investigated the effect of temporary cement and desensitizer on the bond strength of luting cements. Total 96 dentin specimens were divided into two groups with and without temporary cementation. For temporary cement-tread group, specimens were cemented with $Temp-bond^{(R)}$ and all specimens were stored in distilled water at $37^{\circ}C$ for 7 days. Each cup was further divided into 3 subgroups with $Gluma^{(R)},\;One-step^{(R)}$ application and without desensitizer After desensitizer application, Ni-Cr specimens were luted to dentin surface with $Panavia-F^{(R)}$ and $Vitremer^{(R)}$ Specimens were placed in distilled water at $37^{\circ}C$ for 24 hours and shear bond strength between metal and dentin was measured by a universal testing machine. The results were as follows : 1. In $Panavia-F^{(R)}$ cemented groups, the combination of $One-step^{(R)}$ without temporary cement showed the greatest strength. Among the desensitizer types, $One-step^{(R)}$ showed the highest bond strength, followed by No-desensitizer, $Gluma^{(R)}$. 2. In $Vitremer^{(R)}$ cemented groups, the combination of no temporary cement and without desensitizer showed the greatest bond strength. Among the desensitizer types, No-desensitizer group showed the highest bond strength. 3. The use of $Gluma^{(R)}$ significantly reduced the shear bond strength in $Panavia-F^{(R)}$ and $Vitremer^{(R)}$ groups. 4. All temporary cement-treated groups showed a significant lower shear bond strength than without temporary cement groups. 5. Desensitizer application significantly influenced the bond strength of the resin cement and resin modified glass ionomer cement.

AN EXPERIMENTAL STUDY OF BOND STRENGTH OF GLASS IONOMER LUTING CEMENT UNDER THE FUNCTIONAL LOADS ON THE CROWN (기능 하중 하에서 접착용 Glass Ionomer 시멘트의 결합강도에 대한 비교연구)

  • Jun Joong-Hyun;Kang Woo-Jin;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.225-232
    • /
    • 1992
  • The purpose of this study was to compare the bond strength of the glass ionomer luting cements after the functional loads were applied to the crowns respectively 10 min, 30 min, 1 hr, 24 hrs later after mixing of cements. The conventional (GC Fuji I; GC Int. Co., Japan), water hardening type (Ketac Cem; ESPE, W. Germany) glass ionomer luting cement and C-dent ZPC (Confi-Dental Products Co., U.S.A.) as a control were used. The results of this study were obtained as follows: 1. In the bond strength of GC Fuji I, 24 hr-group was highest and there were no statistically significant differences among 10 min-, 30 min- and 1 hr- groups. 2. l3 the bond strength of Ketac Cem and C-dent ZPC, there was no statistically significant differences among 10 min-, 30 min-, 1 hr- and 24 hr-groups respectively. 3. Comparing the bond strength among cements in 10 min-, 30 min-groups respectively, GC Fuji I was lowest and there was no statistically significant difference between Ketac Cem and C-dent ZPC. 4. The bond strengths between GC Fuji I and Ketac Cem were not significantly different in 1 hr-, 24 hr-group. 5. The bond strengths among 3 types of cements were not significantly different in 24 hr-groups.

  • PDF

INFLUENCE OF TOOTH SURFACE ROUGHNESS AND TYPE OF CEMENT ON RETENTION OF COMPLETE CAST CROWNS (치아표면 거칠기와 시멘트 종류가 전부주조관의 유지력에 미치는 영향)

  • Kim, Kil-Su;Song, Chang-Yong;Ahn, Seung-Geun;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.465-473
    • /
    • 1999
  • Bond strength of luting cements to dentin is a critical consideration for success of complete cast crowns. This study was performed to evaluate the relationship between surface characteristics of teeth prepared for complete cast crowns and retention of cemented restorations. Eighty artificial crowns were cast for standardized complete crown tooth preparations accomplished with the use of a special device on recently extracted human teeth. Coarse diamond(#102R, Shofu) and superfine finishing diamond(#SF102R, Shofu) burs of similar shape were used. Crowns in each group were randomly subdivided into few subgroups of 10 for luting cements selected for this study: zinc phosphate cement (FLECK' S), polycarboxylate cement (Poly-F), rein-forced glass ionomer cement (Fuji PLUS). and adhesive resin cement (Panavia 21). Retention was evaluated by measuring the tensile load required to dislodge the artificial crown from tooth preparations with an Instron testing machine, and analysed by one-way ANOVA and Student's t-test. The obtained results were as follows ; 1. When tooth preparation was done with coarse diamond bur, retentive force was diminished in order of Panavia 21 Fuji PLUS, FLECK'S, and Poly-F. Retentive forces showed the significant difference between Fuji PLUS group and FLECK'S group(p<0.001). 2. When tooth preparation was done with superfine diamond bur, retentive force was diminished in order of Fuji PLUS, Panavia 21, FLECK'S, and Poly-F. Retentive forces showed the significant difference between Panavia 21 group and FLECK'S group(p<0.001). 3. Retentive force in coarse tooth surfaces was significantly higher than that in superfine tooth surface with all luting cements(p<0.001), and cement residues were almost retained with-in the cast crown in all groups.

  • PDF

Efficacy of various cleansing techniques on dentin wettability and its influence on shear bond strength of a resin luting agent

  • Munirathinam, Dilipkumar;Mohanaj, Dhivya;Beganam, Mohammed
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.139-145
    • /
    • 2012
  • PURPOSE. To evaluate the shear bond strength of resin luting agent to dentin surfaces cleansed with different agents like pumice, ultrasonic scaler with chlorhexidine gluconate, EDTA and the influence of these cleansing methods on wetting properties of the dentin by Axisymmetric drop Shape Analysis - Contact Diameter technique (ADSA-CD). MATERIALS AND METHODS. Forty coronal portions of human third molar were prepared until dentin was exposed. Specimens were divided into two groups: Group A and Group B. Provisional restorations made with autopolymerizing resin were luted to dentin surface with zinc oxide eugenol in Group A and with freegenol cement in Group B. All specimens were stored in distilled water at room temperature for 24 hrs and provisional cements were mechanically removed with explorer and rinsed with water and cleansed using various methods (Control-air-water spray, Pumice prophylaxis, Ultrasonic scaler with 0.2% Chlorhexidine gluconate, 17% EDTA). Contact angle measurements were performed to assess wettability of various cleansing agents using the ADSA-CD technique. Bond strength of a resin luting agent bonded to the cleansed surface was assessed using Instron testing machine and the mode of failure noted. SEM was done to assess the surface cleanliness. Data were statistically analyzed by one-way analysis of variance with Tukey HSD tests (${\alpha}$=.05). RESULTS. Specimens treated with EDTA showed the highest shear bond strength and the lowest contact angle for both groups. SEM showed that EDTA was the most effective solution to remove the smear layer. Also, mode of failure seen was predominantly cohesive for both EDTA and pumice prophylaxis. CONCLUSION. EDTA was the most effective dentin cleansing agent among the compared groups.

Comparison of effect of desensitizing agents on the retention of crowns cemented with luting agents: an in vitro study

  • Jalandar, Sonune Shital;Pandharinath, Dange Shankar;Arun, Khalikar;Smita, Vaidya
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.127-133
    • /
    • 2012
  • PURPOSE. Many dentists use desensitizing agents to prevent hypersensitivity. This study compared and evaluated the effect of two desensitizing agents on the retention of cast crowns when cemented with various luting agents. MATERIALS AND METHODS. Ninety freshly extracted human molars were prepared with flat occlusal surface, 6 degree taper and approximately 4 mm axial length. The prepared specimens were divided into 3 groups and each group is further divided into 3 subgroups. Desensitizing agents used were GC Tooth Mousse and $GLUMA^{(R)}$ desensitizer. Cementing agents used were zinc phosphate, glass ionomer and resin modified glass ionomer cement. Individual crowns with loop were made from base metal alloy. Desensitizing agents were applied before cementation of crowns except for control group. Under tensional force the crowns were removed using an automated universal testing machine. Statistical analysis included one-way ANOVA followed by Turkey-Kramer post hoc test at a preset alpha of 0.05. RESULTS. Resin modified glass ionomer cement exhibited the highest retentive strength and all dentin treatments resulted in significantly different retentive values (In Kg.): GLUMA ($49.02{\pm}3.32$) > Control ($48.61{\pm}3.54$) > Tooth mousse ($48.34{\pm}2.94$). Retentive strength for glass ionomer cement were GLUMA ($41.14{\pm}2.42$) > Tooth mousse ($40.32{\pm}3.89$) > Control ($39.09{\pm}2.80$). For zinc phosphate cement the retentive strength were lowest GLUMA ($27.92{\pm}3.20$) > Control ($27.69{\pm}3.39$) > Tooth mousse ($25.27{\pm}4.60$). CONCLUSION. The use of $GLUMA^{(R)}$ desensitizer has no effect on crown retention. GC Tooth Mousse does not affect the retentive ability of glass ionomer and resin modified glass ionomer cement, but it decreases the retentive ability of zinc phosphate cement.

The Effect of Dentin Desensitization Treatment on the Shear Bond Strength of Luting Cements (상아질 지각과민 완화법이 접착용 시멘트의 전단결합강도에 미치는 영향)

  • Park, In-Ho;Lee, Joon-Soek;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.231-242
    • /
    • 2006
  • Statement of problem: The sealing of the opened dentinal tubules that follows the tooth preparation for the prosthodontic restoration is considered as clinical process to reduce postoperative sensitivity. Purpose: This study investigated the effect of desensitization treatment on shear bond strength of luting cements. Materials and Method: Total 80 dentin specimens were divided into two groups according to the kinds of luting cements. Each groups was further divided into 4 subgroups with AQ $bond^{(R)}$, $Saforide^{(R)}$, Diode laser $MDL-10^{(R)}$ application and without desensitization treatment. After desensitization treatment application, Ni-Cr specimens were luted to dentin surface with Fuji $CEM^{(R)}$ and $Panavia-F^{(R)}$. Specimens were placed in distilled water at $37^{\circ}C$ for 24 hours and shear bond strength between metal and dentin was measured by a universal testing machine. Results: 1. In Fuji $CEM^{(R)}$ cemented groups, the combination of AQ $bond^{(R)}$ showed the greatest strength, followed by diode laser, no desensitizer treatment, and $Saforide^{(R)}$. Both AQ $bond^{(R)}$ and Diode laser groups had a significant difference than no desensitization treatment group and $Saforide^{(R)}$ group(p<0.05). 2. In $Panavia-F^{(R)}$ cemented groups, the combination of Diode laser showed the greatest strength, followed by AQ $bond^{(R)}$, $Saforide^{(R)}$, and No desensitization treatment. All desensitization treatment groups had a significant difference than no desensitization treatment group(p<0.05). 3. All $Panavia-F^{(R)}$ groups showed a significant higher shear bond strength than all Fuji $CEM^{(R)}$ groups(p<0.05). Conclusion: The results of this study showed possibility of bond strength increase after desensitization treatment. The application of desensitization treatments like AQ $bond^{(R)}$, $Saforide^{(R)}$, and Diode laser $MDL-10^{(R)}$ have advantages in exposed dentin surface after tooth prep.

Effects of dentin moisture on the push-out bond strength of a fiber post luted with different self-adhesive resin cements

  • Turker, Sevinc Aktemur;Uzunoglu, Emel;Yilmaz, Zeliha
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.4
    • /
    • pp.234-240
    • /
    • 2013
  • Objectives: This study evaluated the effects of intraradicular moisture on the pushout bond strength of a fibre post luted with several self-adhesive resin cements. Materials and Methods: Endodontically treated root canals were treated with one of three luting cements: (1) RelyX U100, (2) Clearfil SA, and (3) G-Cem. Roots were then divided into four subgroups according to the moisture condition tested: (I) dry: excess water removed with paper points followed by dehydration with 95% ethanol, (II) normal moisture: canals blot-dried with paper points until appearing dry, (III) moist: canals dried by low vacuum using a Luer adapter, and (IV) wet: canals remained totally flooded. Two 1-mm-thick slices were obtained from each root sample and bond strength was measured using a push-out test setup. The data were analysed using a two-way analysis of variance and the Bonferroni post hoc test with p = 0.05. Results: Statistical analysis demonstrated that moisture levels had a significant effect on the bond strength of luting cements (p < 0.05), with the exception of G-Cem. RelyX U100 displayed the highest bond strength under moist conditions (III). Clearfil SA had the highest bond strength under normal moisture conditions (II). Statistical ranking of bond strength values was as follows: RelyX U100 > Clearfil SA > G-Cem. Conclusions: The degree of residual moisture significantly affected the adhesion of luting cements to radicular dentine.

SHEAR BOND STRENGTH OF PRETREATED DENTIN SURFACE WITH RESIN-REINFORCED GLASS IONOMER CEMENT (상아질의 치면 처리에 따른 합착용 레진 강화형 글라스 아이오노머 시멘트의 전단결합강도)

  • Choi Hye-Souk;Lee Cheong-Hee;Jo Kwang-Hun;Kim Kyo-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.502-513
    • /
    • 2001
  • The purpose of this study was to evaluate the effect of dentin pretreatment with Dentin Conditioner, Ultra-Etch, conditioner of Fuji Plus cement on the shear bond strength of resin-reinforced glass ionomer cements to dentin and analyze the fractured surfaces. To evaluate the bond strength, the extracted human teeth which had uniform area of exposed dentin were cemented with conventional glass ionomer cement, 3M $RelyX^{TM}$ Luting (Vitremer luting cement), Fuji Plus cement after dentin pretreatment. The shear bond strength was measured using the Universal testing machine (Instron Co., USA) with a crosshead speed of 1mm/m. The effect of dentin pretreatment was evaluated by observing pretreated dentin surfaces under the scanning electron microscope, measuring the shear bond strength and observing the fractured surfaces under the scanning electron microscope. The results were as follows : On the SEM observation of surface morphology, the specimens treated with Dentin Conditioner. Ultra-Etch and conditioner of Fuji Plus cement were removed the smear layer and funneled dentinal tubules in dentin surfaces. In $RelyX^{TM}$ Luting cement group, shear bond strength of pretreated group was significantly higher than control group. In Fuji Plus cement group and Fuji I group, regardless of the type of pretreatment agents, there was tendency of increase in the shear bond strength. On the SEM observation of fractured surfaces, as the shear bond strength increase, it were shown thicker cement layers and were not shown dentinal tubules According to these results. it were shown that dentin pretreatment have much effect on bonding states.

  • PDF