• 제목/요약/키워드: luminous

검색결과 944건 처리시간 0.024초

치과 진료실의 조명에 관한 실태 조사연구 (A STUDY ON THE ILLUMINATION OF DENTAL CLINIC)

  • 최종인;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Analysis of the luminous efficacy improvement in Full HD ac Plasma Display Panel

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.29-32
    • /
    • 2007
  • We analyzed the effect of cell resolution on the luminous efficacy through three-dimensional numerical simulation to understand the inherent discharge mechanism change in the plasma display panel. As the resolution increases from VGA to Full HD, the luminous efficacy decreases. With higher Xe content, VUV generation efficacy of Full HD becomes much lower than those of VGA or XGA cells, due to the increased plasma loss and lower electron heating. However a long electrode gap $140{\mu}m$ in Full HD cell with Ne-Xe [20%] results in the high luminous efficacy comparable to that of the XGA cell with $60{\mu}m$ gap. When comparing the effects of Xe content variation on the luminous efficacy of two different subpixel types, i. e., SDE (Segmented electrode in Delta color arrayed, Enclosed subpixel) [1] and conventional stripe barrier type in the XGA and Full HD cells, the luminous efficacy of SDE structure shows higher improvement in Full HD resolution compared with that of conventional type XGA cell, whose cause is identified as the reduced plasma loss.

  • PDF

사용자 요구 조도 보장 에너지 효율적 실내 조명 시스템 조명 방향 및 광속 제어 기법 (A Lighting direction and Luminous Flux Control for Energy-efficiency under Illuminance Requirements in Indoor Lighting Systems)

  • 김훈
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.19-25
    • /
    • 2015
  • The management of energy resources for efficient utilization of the energy resources while reducing the system costs is a critical technical issue. Among many kinds of the energy resource management, the energy reduction for indoor lighting systems is getting much concern as a large portion of energy consumption has been made for indoor lightings. In this paper, an energy-efficient lighting control scheme for indoor lighting systems in order to reduce the energy consumption by controlling the luminous flux and the lighting direction under the illuminance constraints is proposed. With the use of the user location information for the luminaire which is closely located to the user, the proposed scheme firstly sets the light direction of the luminaire to be aligned to the user location. Then, an optimization problem to find the luminous flux of each luminaire is formulated in order to minimize the luminous flux sum of the luminaires with the constraints for the dynamic ragne of the luminous flux, and the light flux for each luminaire is determined by the solution of the problem. Simulation results show that the proposed scheme outperforms the luminaire control scheme with only the luminous flux control in the evaluation of satisfaction of the required illuminance level.

조피볼락에 대한 Vibrio harveyi의 병원성 (Pathogenicity of Vibrio harveyi to black rockfish, Sebastes schlegeli)

  • 최정현;원경미;손새봄;박효진;변순규;이배익;이종하;김이청;박수일
    • 한국어병학회지
    • /
    • 제20권2호
    • /
    • pp.99-108
    • /
    • 2007
  • 본 연구는 V. harveyi의 luminescence 유무와 해수 어류에 대한 병원성의 관계를 알아보고자 non-luminous V. harveyi 와 luminous V. harveyi 분리 균주로 조피볼락에 대한 병원성 시험을 시행하였다. 시험 균주 V. harveyi 모두 haemolytic activity를 나타내었으며, 어체 내 생존능은 non-luminous V. harveyi 분리 균주 FR 2가 강한 생존능을 나타내었다. 또한 조피볼락에 인위 감염시, non-luminous V. harveyi 분리 균주 FR 2가 강한 병원성을 나타내었으며 luminous V. harveyi 분리 균주 VIB 391은 낮은 병원성을 나타내었다. 결론적으로 조피볼락에서는 non-luminous V. harveyi 분리 균주 FR 2가 강한 병원성을 나타내었으며 luminous V. harveyi 분리 균주 VIB 391은 매우 약한 병원성을 나타내어 luminescence의 유무에 따라 해수 어종에 대한 병원성의 차이가 있을 것으로 생각된다

High Efficient Structure of Plasma Tubes

  • Ishimoto, Manabu;Tokai, Akira;Shinohe, Koji;Awamoto, Kenji;Shinoda, Tsutae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.103-108
    • /
    • 2004
  • The plasma tube array display is expected to realize the wall size display with very high luminous efficacy. The cell design for high luminous efficacy was investigated. Also discharging in plasma tube was observed to investigate the structure for high luminous efficacy. As the result, high luminous efficacy of 5.4 lm/W was achieved.

  • PDF

Plasma Jet의 동축평행 자계에 의한 영향에 관한 연구 ( 1 ) (A Study on the Influence of Coaxial Parallel Magnetic Field upon Plasma Jet)

  • 전춘생
    • 전기의세계
    • /
    • 제22권2호
    • /
    • pp.57-69
    • /
    • 1973
  • The aim of this study was to investigate the behaviors of plasma jet under coaxial magnetic field in paralled with it for controlling optical characteristics and input power of plasma jet without impurity and instability of arc plasma column. Because the discharge characteristics of plasma jet were so distinctively different according to the existence or non-existence of magnetic field, the input power, luminous intensity of plasma jet and thermal efficiency were comparatively studied in respect of such variables as arc current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle, with the use of several materials which were different in diameter and length of nozzel. The results were as follows; 1) The voltage tends to show a drooping characteristic at law current and then rises gradually. The luminous intensity of plasma jet increases exponentially with arc current. 2) Arc voltage increases and luminous intensity tends to decrease gradually as gap of electrode increases. 3) Arc voltage and luminous intensity tends to decrease gradually as gap of electrode increases. 3) Arc voltage and luminous intensity increase in accordance with the quantity of argon flow. 4) At first step, arc voltage increases to maximum value with the growth of flux density and then tends to show a gradual decrease. Luminous intensity decreases with the growth flux density. 5) Arc voltage decreases as the constriction length of nozzle increases, maximum decrease is shown at the constriction length of 20(mm) and it increases beyond that value. The luminous intensity decreases as the constriction length grows. 6) Arc voltage and luminous in tensity increase with the growth of diameters of nozzle. 7) Thermal efficiency has values between 50% and 75%, being influenced by arc current, the quantity of argon flow, flux density, the length of electrode gap and the constriction length of nozzle.

  • PDF

건축물내 자체발광식 피난유도선 설치에 따른 피난성능 평가 (The Evaluation of the Egress Performance in the Buildings Installed with Luminous Egress Guide-lines)

  • 박용환;김범규;임채현
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.120-126
    • /
    • 2011
  • 고시원 등 다중이용업소의 경우 밀집화된 공간구조로 인해 화재 시의 인명위험도가 크게 부각됨에 따라 해당 건축물에 발광식 피난유도선의 설치를 도입함으로써 거주자의 피난안전성 확보를 꾀하고 있다. 그러나 자체발광식 피난유도선의 설치에 따른 피난성능 향상의 정량적, 정성적 평가에 대한 국내외 연구는 거의 없는 실정이어서, 본 연구에서는 기존의 피난유도등과 새로운 자체발광식 피난유도선에 대하여 다양한 피난시나리오에 따른 피난성능을 실험적으로 평가하였다. 실험결과는 피난유도선 및 유도등 모두 법적 기본 성능기준을 만족하였으나, 7 %의 낮은 연기투과율에서는 피난유도선의 식별거리가 유도등에 비해 약 3배 정도 뛰어난 식별성능을 나타내었다. 또한 연기투과율이 낮을수록 피난유도선쪽이 피난유도등에 비해 피난시간이 훨씬 짧은 것을 볼 때 성능 측면에서 피난유도선이 훨씬 효과적인 것으로 관측되었다. 피난유도선 미설치 시에는 피난시간 증가율이 피난밀도나 연기투과율에 크게 영향을 받았으나 피난유도선 설치시에는 별 영향을 받지 않는 것으로 나타났다.

산화아연(ZnO) 피뢰기 소자와 전극사이에서 발생하는 방전광 특성 (The characteristics of the luminous events caused between the ZnO arrester block and electrode)

  • 이복희;박건영;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1869-1871
    • /
    • 2004
  • The primary role of ZnO arresters is to protect transmission and distribution equipments against lightning surges. The extremely nonlinear V-I characteristics of the ZnO arrester obviates the need for isolation gaps and consequently it is continuously connected to line voltage. For this reason, ZnO arresters are degraded with increasing with time in actual power systems. In this work, the characteristics of the luminous events between the ZnO block and electrodes were investigated. As a result, the luminous events were effected by the impulse and the near polarity of the luminous event was intense near the grounded electrode. Also the luminous event may cause the degradation of ZnO arrester block.

  • PDF

Effect of Some Design Factors in the Front Panel on the Characteristics of a Plasma Display

  • Kim, Beong-Ju;Moon, Chelo-Hee
    • Journal of Information Display
    • /
    • 제9권3호
    • /
    • pp.28-32
    • /
    • 2008
  • Low sustained voltage $(V_s)$ and high luminous efficiency (lumen/Watts) are required for the enhanced performance of an AC PDP. Both are not realized in the same condition, however, because luminous efficiency decreases when the sustained voltage is lowered in most cases. In this study, the three design factors in the front panel of a PDP, i.e., the thickness and position of the bus electrode and the thickness of the dielectric layer, were chosen to investigate how they affect the sustained voltage and the luminous efficiency, and to find a way to optimize them. Two values were given to each of the three design factors, and experiments were done via full factorial design, i.e., with a total of eight conditions, using a 3-in.diagonal test panel. The changes in the sustained voltage and the luminous characteristics were explained in connection with the discharge characteristics of the PDP cells.

간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석 (Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires)

  • 김유신;최안섭
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.