• Title/Summary/Keyword: lower screening limit

Search Result 18, Processing Time 0.018 seconds

Determination of Optimal Mean Value and Screening Limit for a Production Process with Logistic Function (로지스틱 함수를 갖는 생산공정에 대한 최적공정평균 및 스크리닝 한계선의 결정)

  • Hong, Sung Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.29 no.3
    • /
    • pp.239-246
    • /
    • 2003
  • Individual items are produced continuously from an industrial process. Each item is checked to determine whether it satisfies a lower screening limit for the quality characteristic which is the weight of an expensive ingredient. If it does, it is sold at a regular price; if it does not, it is reprocessed or sold at a reduced price. The process mean may be adjusted to a higher value in order to reduce the proportion of the nonconforming items. Using a higher process mean, however, may result in a higher production cost. In this paper, the optimal process mean and lower screening limit are determined in situations where the probability that an item functions well is given by a logistic function of the quality characteristic. Profit models are constructed which involve four price/cost components; selling prices, cost from an accepted nonconforming item, and reprocessing and inspection costs. Methods of finding the optimal process mean and lower screening limit are presented and numerical examples are given.

Design of Rectifying Screening Procedures Using a Surrogate Variable (대용특성을 이용한 선별형 스크리닝 절차의 설계)

  • Hong, Sung-Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.1
    • /
    • pp.51-60
    • /
    • 2006
  • When the nature of measuring a performance variable is destructive or very expensive, it is attractive to use a surrogate variable which is highly correlated with the performance variable and less expensive to measure. In this paper, we propose rectifying screening procedures using the performance and surrogate variables. Two screening procedures are considered; a statistically-based screening procedure to reduce the current proportion of nonconforming items to a specified lower value after screening, and an economically-based screening procedure where the screening limit is determined so that the expected cost is minimized. It is assumed that the surrogate variable given the performance variable is normally distributed with known mean and standard deviation. For two screening procedures, methods of finding the optimal solutions are presented and numerical examples are also given.

A Study on Economic Selection of the Process Target and the Screening Specification Limits in a Continuous Production Process (연속생산공정에서 공정목표값과 검사규격한계의 경제적인 결정에 관한 연구)

  • 백종석;윤덕균
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.4
    • /
    • pp.57-70
    • /
    • 1997
  • Consider a production system where all manufactured products are screened through automatic inspection equipment. The products for which the measured value of quality characteristic is larger than the lower screening specification limit (SL) and smaller than the u, pp.r screeing specification limit(SU) are accepted. Those smaller than SL are reworked and those larger than SU are excluded from the process. Assuming that the quality characteristic is normally distributed with known variance, this paper suggests cost models which involve inspection cost, production cost, rework cost, exclusion cost and quality cost, and presents the methods of finding the optimal values of the screening specification limits and the process target. Numerical example is given to demonstrate the a, pp.icability of the cost models suggested in this paper.

  • PDF

Design of Rectifying Screening Procedures (선별형 스크리닝 절차의 설계)

  • Hong Seong-Hun;Choi Ik-Jun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.70-77
    • /
    • 2006
  • When the nature of measuring a performance variable is destructive or very expensive, it is attractive to use a surrogate variable which is highly correlated with the performance variable and less expensive to measure. In this paper, we propose rectifying screening procedures using the performance and surrogate variables. Two screening procedures are considered; a statistically-based screening procedure to reduce the current proportion of nonconforming items to a specified lower value after screening, and a economically-based screening procedure where the screening limit is determined so that the expected cost is minimized. It is assumed that the surrogate variable given the performance variable is normally distributed with known mean and standard deviation. For two screening procedures, methods of finding the optimal solutions are presented and numerical examples are also given.

  • PDF

Cost-effectiveness Outcomes of the National Gastric Cancer Screening Program in South Korea

  • Cho, Eun;Kang, Moon Hae;Choi, Kui Son;Suh, MiNa;Jun, Jae Kwan;Park, Eun-Cheol
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2533-2540
    • /
    • 2013
  • Background: Although screening is necessary where gastric cancer is particularly common in Asia, the performance outcomes of mass screening programs have remained unclear. This study was conducted to evaluate cost-effectiveness outcomes of the national cancer screening program (NCSP) for gastric cancer in South Korea. Materials and Methods: People aged 40 years or over during 2002-2003 (baseline) were the target population. Screening recipients and patients diagnosed with gastric cancers were identified using the NCSP and Korea Central Cancer Registry databases. Clinical outcomes were measured in terms of mortality and life-years saved (LYS) of gastric cancer patients during 7 years based on merged data from the Korean National Health Insurance Corporation and National Statistical Office. We considered direct, indirect, and productivity-loss costs associated with screening attendance. Incremental cost-effectiveness ratio (ICER) estimates were produced according to screening method, sex, and age group compared to non-screening. Results: The age-adjusted ICER for survival was 260,201,000-371,011,000 Korean Won (KW; 1USD=1,088 KW) for the upper-gastrointestinal (UGI) tract over non-screening. Endoscopy ICERs were lower (119,099,000-178,700,000 KW/survival) than UGI. To increase 1 life-year, additional costs of approximately 14,466,000-15,014,000 KW and 8,817,000-9,755,000 KW were required for UGI and endoscopy, respectively. Endoscopy was the most cost-effective strategy for males and females. With regard to sensitivity analyses varying based on the upper age limit, endoscopy NCSP was dominant for both males and females. For males, an upper limit of age 75 or 80 years could be considered. ICER estimates for LYS indicate that the gastric cancer screening program in Korea is cost-effective. Conclusion: Endoscopy should be recommended as a first-line method in Korea because it is beneficial among the Korean population.

A Comparative Analysis of the Level of Occupational Health : Before and After the Subsidiary Program on Health Care Management of Small Scale Industries (영세사업장 보건관리 지원사업 실시 전후의 산업보건수준 비교 분석)

  • Jung, Hye Sun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.4
    • /
    • pp.58-83
    • /
    • 1995
  • The small scale industries which have less than 30 employees occupy 86.5% of total number of industries in Korea. And though they have higher accident rate and lower environmental condition than big industries, it has been not mandatory to appointing health care manager at factory. So, from 1993, government subsidizes to the health care management of small industries. The purpose of this study is to identify the real feature of health care status in small industries, and to evaluate the level of health care management, before and after the subsidiary program. 65 small plating industries which have been managed by the same health care management support institution in 1993 were selected for study. Of the 65 industries, 3 which have not taken both environmental evaluation and health screening in 1994, and 9 which have closed were excluded from study sample. And the remaining 53 were analyzed by using the results of environmental evaluation and health screening, reported to the Ministry of Labor, before and after the subsidiary program, the analysis was done by the comparison of the two year paired data of the same industry. Over-permissible-limit rate, health screening implementation rate, above grade C rate were calculated and compared. The status of health care management ; 1. Of the sample industries, 96.9% provide protective equipment and 80.0% set up ventilating system. Protective gloves (89.2%) and protective clothing (80.0%) are widely provided, but ear plugs (4.6%) are rarely provided. 21.5% of the protective equipment are well put on, and 40.4% of the ventilating systems function well. 2. In 1993, 35 industries, 53.8% of the sample, checked working environment twice. Over-permissible-limit rates of heavy metal (12.2%), suspended particle (11.1%), noise (5.5%) were high. To put on protective equipment and to set up local ventilating system were pointed out by the examiners. 3. General health screening was done at 63.1% of the sample industries and 35.3% of total workers were examined. Specific health screening was done at 93.8% of the sample industries and 75.4% of workers were examined. 15.5% of workers was provided to be above grade C and to have digestive system disease (43.3%), circulatory disease (18.9%), and hematopoietic disease (14.2%), etc. 4. In 1993, the subsidiary program of health care management was provided in forms of health education, health counseling, and rounding check of working field. And 61.5%, 83.0%, 55.4% of sample industries respectively received it. The average visit per industry was 1.8. Comparisons of the level of occupational health before and after the subsidiary program ; 1. Over-permissible-limit rates of hazardous factors of 1993 and that of 1994 were compared. The rates of suspended particle, noise, organic solvent of 1994 (37.5%, 13.4%, 24.2% respectively) were higher than that of 1993 (25.0%, 6.0%, 6.3% respectively). In the case of acid, there was no difference between the rate of 1993 and that of 1994. Only the rate of heavy metal decreased from 12.9% in 1993 to 3.0% in 1994. 2. General health screening was done at 38.7% of the sample industries in 1993 and at 44.6% in 1994. But the implementation rate of specific health screening decreased from 72.4% in 1993 to 64.6% in 1994. 3. The implementation rate of specific health screening was analyzed by some health factors. The rate of suspended particle increased from 61.8% in 1993 to 91.2% in 1994. But the rates of the others-noise, organic solvent, heavy metal, specific chemical substances-decreased. 4. Above grade C rate in health screening increased from 27.8% in 1993 to 35.5% in 1994. But that of endocrine disorders and pulmonary disease decreased.

  • PDF

Post-polypectomy surveillance: the present and the future

  • Masau Sekiguchi;Takahisa Matsuda;Kinichi Hotta;Yutaka Saito
    • Clinical Endoscopy
    • /
    • v.55 no.4
    • /
    • pp.489-495
    • /
    • 2022
  • An appropriate post-polypectomy surveillance program requires the effectiveness of reducing colorectal cancer and safety. In addition, the post-polypectomy surveillance program should consider the burden of limited medical resource capacity, cost-effectiveness, and patient adherence. In this sense, a risk-stratified surveillance program based on baseline colonoscopy results is ideal. Major international guidelines for post-polypectomy surveillance, such as those from the European Union and the United States, have recommended risk-stratified surveillance programs. Both guidelines have recently been updated to better differentiate between high- and low-risk individuals. In both updated guidelines, more individuals have been downgraded to lower-risk groups that require less frequent or no surveillance. Furthermore, increased attention has been paid to the surveillance of patients who undergo serrated polyp removal. Previous guidelines in Japan did not clearly outline the risk stratification in post-polypectomy surveillance. However, the new colonoscopy screening and surveillance guidelines presented by the Japan Gastroenterological Endoscopy Society include a risk-stratified post-polectomy surveillance program. Further discussion and analysis of unresolved issues in this field, such as the optimal follow-up after the first surveillance, the upper age limit for surveillance, and the ideal method for improving adherence to surveillance guidelines, are warranted.

Improvement of the Result Related to Tumor Marker Test Through the OCS QC Program (OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선)

  • Back, Song-Ran;Kim, Sung-Ho;Yoo, So-Yeon;Kim, Nyun-Ok;Moon, Hyoung-Ho;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.185-188
    • /
    • 2009
  • Purpose: Standard of retests were discrepant and inconsistent due to inaccuracy and lack of standardization within normal range limit of tumor marker test. To enhance the standardization of retests set standard value below normal range and the Order Communication System Quality Control (OCS QC) program was put in place. This program enables managing the results within lower limit of normal range which were used for tumor marker test in Health Center. Materials and Methods: At present the tumor marker study for AFP, CEA, CA19-9, CA125, and PSA included outpatients in Asan Medical Center from February to March, 2009. The standard value was obtained by using the percentage of CV of Inter Assay according to the normal range of each tumor test. The results were confirmed by using the OCS QC program via formatted assessment of screening test such as test items, standard value and medical department. The number of out-of-range results within plus and minus 30 percents regarding the five primary items of tumor marker test was assessed. The next step was to obtain the number of AFP, CEA, and CA125 according to the ratio of comparison between prior and post test result, 60%, 50%, and 40% within normal range, respectively. In addition, set standard value below normal range. Results: The first screening test with percentage of sample number was resulted between 30%-40% and the second one was AFP 26.1%, CEA 18.9%, CA19-9 17.3%, CA125 18.7%, and PSA 21.0% obtained screening percentage of average 20 percents. The limited value of retest was AFP less than 5.0 and more than 10.0, CEA less than 1.0 and more than 3.0, CA19-9 less than 10.0 and more than 30.0, and PSA less than 1.0 and more than 2.0 to set and the number of retest was obtained by applying to the limited value of retest to screening percentage of average 20 percents For two months, the number of retest was AFP 0, CEA 15, CA19-9 3, CA125 2, and PSA 5. Conclusions: Through using the OCS QC program in establishing the standard of retest systemically, there appeared to be reduced discrepancy among the examiners and to be expected improvement in relation to the error of results.

  • PDF

A Process Monitoring Procedure Using a Correlated Variable (상관변수를 이용한 공정 감시 절차)

  • 권혁무;이민구;김상부;홍성훈
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.1
    • /
    • pp.35-45
    • /
    • 1999
  • A process monitoring procedure using a correlated variable is presented when a lower specification limit is given on the performance variable. Every item is inspected with a variable correlated with the performance variable. When an item is rejected in the screening inspection, the process is checked for change using the mean and variance of measurements of the correlated variable for n preceding items including the rejected one. The performance variable is assumed to be normally distributed. A linear relationship between the performance and surrogate variables is assumed with normally distributed error term. The monitoring procedure is designed so that the prespecified outgoing quality can be attained.

  • PDF

Steroid Hormone Receptor/Reporter Gene Transcription Assay for Food Additives and Contaminants

  • Jeong Sang-Hee;Cho Joon-Hyoung;Park Jong-Myung
    • Toxicological Research
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2006
  • Many of endocrine disrupting chemicals induce effects via interaction with hormone receptors and responsive elements in target cells. We investigated endocrine disrupting effects of some food additives and contaminants including BHA, BHT, ethoxyquin, propionic acid, sorbic acid, benzoic acid, CPM, aflatoxin B1, cadmium chloride, genistein, TCDD and PCBs in yeast transformants expressing human steroid hormone receptors along with steroid responsive elements. The response limit of genetically recombinant yeast to $17{\beta}$-estradiol, testosterone and progesterone was $1{\times}10^{-16},\;1{\times}10^{-12}\;and\;1{\times}10^{-13}M$, respectively. BHT induced weak transcriptional activity in estrogen sensitive yeast, while BHA and sorbic acid interacted weakly with androgen receptor/responsive element. CPM induced transcriptional activities in all types of yeasts sensitive to steroid hormones. Zearalenone and genistein induced high transcriptional activation in estrogen sensitive yeast with relative potencies almost $10^8$ folds lower than $17{\beta}$-estradiol. TCDD induced transcriptional activation weakly in estrogen- and progesterone- sensitive yeasts. This study elucidated that recombinant yeast is a sensitive and high-throughput system and can be used for the direct assessment on chemical interactions with steroid receptors and responsive elements. Also, the present study raises the requirement of evaluation on the endocrine disrupting effects of BHT, BHA, sorbic acid, CPM and TCDD for their transcription activity in yeast screening system though weak in intensity.