• Title/Summary/Keyword: low power network

Search Result 1,244, Processing Time 0.033 seconds

Elimination of harmonics in three-Phase PWM inverter using auxiliary partial resonant circuit (보조부분 공진 회로를 이용한 삼상 PWM 인버터의 고조파 제거)

  • Suh, Ki-Young;Lee, Hyun-Woo;Kim, Young-Mun;Mun, Sang-Pil
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.137-140
    • /
    • 1998
  • A new SPWM inverter using three-phase boost converter by auxiliary partial resonant with high power factor and high efficiency is proposed. The proposed boost converter is constructed by using a resonant network in parallel with the switch of the conventional boost converter. The devices are switched at zero voltage or zero current eliminating the switching loss. A new Partial resonant boost converter achieves zero-voltage switching (ZVS) or zero-current switching (ZCS) for all switch devices without increasing their voltage and current stresses. This paper introduces elimination of low-order harmonics compared with conventional SPWM inverter and SPWM inverter using three-phase boost converter by auxiliary Partial resonant.

  • PDF

Adaptive Control Method for Low-power Consumption Wireless Sensor Network (저전력 무선센서네트워크를 위한 적응제어 방법)

  • Choi, Byeong-cheol;Ryu, Jae-Hong;Kim, Dongwon
    • Annual Conference of KIPS
    • /
    • 2012.11a
    • /
    • pp.695-697
    • /
    • 2012
  • Zigbee와 같은 무선 네트워크에서 전력 절감을 위하여서는 슈퍼프레임을 구성하는 비콘주기내에서 액티브구간과 인액티브구간으로 운용될 시 전력 소모를 줄이기 위하여 네트워크의 트래픽 특성과 부하 정도에 따라 액티브 구간을 적응 제어하는 방법이 제안되었다. 제안 방법에 따른 성능을 분석하여 전력 소모가 감소하여 보다 효과적인 센서 네트워크를 구축할 수 있음을 보인다.

A Study on the Establishment of Massive IoT based on Low Power Wide Area Network Technology (저전력 광역 네트워크 기술 기반 Massive IoT 구축 연구)

  • Lee, Gyeongheon;Hong, Jiyeon;Youn, Joosang
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.103-104
    • /
    • 2019
  • 최근 스마트시티 구축 사업에서 사물인터넷 기반 서비스 개발이 활발히 진행 중이다. 그 서비스들을 제공하기 위해 사용되어야 할 디바이스 수가 수백만 개까지 증가할 것으로 예상하고 있으며 수백만 개의 디바이스들을 수용하기 위해서는 Massive IoT 네트워크의 환경 구축을 필요로 하고 있다. 따라서 본 논문에서는 Massive IoT 네트워크 환경을 구축하기 위해 저전력 광역 네트워크(LPWAN) 기술 중 LoRa(Long Range) 네트워크가 적용이 가능한지를 LoRaSim을 이용하여 시뮬레이션한다. 시뮬레이션한 결과 중 충돌 횟수를 통해 충동률을 구하고 그래프를 이용하여 신뢰성을 나타내며, Massive IoT 네트워크에 적합성에 대해 분석한다.

  • PDF

Cryptanalysis of Bresson-Chevassut-Essiari-Pointcheval′s Key Agreement Scheme for Low-Power Mobile Devices (Bresson-Chevassut-Essiari-Pointcheval의 저전력 모바일 장치를 위한 키 동의 방식의 안전성 분석)

  • Nam Junghyun;Lee Younggyo;Kim Seungioo;Won Dongho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.15 no.1
    • /
    • pp.67-76
    • /
    • 2005
  • Bresson et al. have recently proposed an efficient group key agreement scheme well suited for a wireless network environment. Although it is claimed that the proposed scheme is provably secure under certain intractability assumptions, we show in this paper that this claim is unfounded, breaking the allegedly secure scheme in various ways.

Design of an Ultra-Low Power Sensor Network System based on Energy Harvesting Technique (에너지 수확 기법에 기반 한 초저전력 센서 네트워크 시스템의 설계)

  • Kim, Yun Ho;Seong, Yeong Rak;Oh, Ha Ryoung;Park, Jun Seok
    • Annual Conference of KIPS
    • /
    • 2009.04a
    • /
    • pp.885-888
    • /
    • 2009
  • 센서네트워크 시스템에서 배터리 대신 에너지 수확기법을 이용할 경우 획득할 수 있는 에너지는 제한적이기 때문에 기존의 방식에는 한계가 따른다. 본 논문에서는 이를 극복하기 위한 방안을 제시하고 이를 이용한 에너지 수확 기법에 기반 한 초저전력 센서네트워크 시스템을 구현하여 그 성능을 평가해 보았다.

Evaluation of EM Susceptibility of an PLL on Power Domain Networks of Various Printed Circuit Boards (다양한 PCB의 전원 분배 망에서의 PLL의 전자기 내성 검증)

  • Hwang, Won-Jun;Wee, Jae-Kyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.74-82
    • /
    • 2015
  • As the complexity of an electronic device and the reduction of its operating voltage is progressing, susceptibility test of the chip and module for internal or external noises is essential. Although the immunity compliance of the chip was served with IEC 62132-4 Direct Power Injection method as an industry standard, in fact, EM immunity of the chip is influenced by their Power Domain Network (PDN). This paper evaluates the EM noise tolerance of a PLL and compares their noise transfer characteristics to the PLL on various PCB boards. To make differences of the PDNs of PCBs, various PCBs with or without LDO and with several types of capacitors are tested. For evaluation of discrepancies between EM characteristics of an IC only and the IC on real boards, the analysis of the noise transfer characteristics according to the PDNs shows that it gives important information for the design having robust EM characteristics. DPI measurement results show that greatly improved immunity of the PLL in the low-frequency region according to using the LDO and a frequency change of the PLL according to the DPI could also check with TEM cell measurement spectrum.

Fabrication of a Multiplexing Sensor Probe for Measuring the Blade Deflection of a Wind Power Generator (풍력발전기 블레이드 처짐 측정을 위한 다중화 센서 탐촉자 설계 제작)

  • Kim, Ji-Dea;Lee, Dong-Ju
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.178-185
    • /
    • 2014
  • This paper describes a fabrication multiplexing sensor probe that employs a fiber Bragg grating(FBG) based on multiple measurements to determine the blade deflection of a wind power generator the reliability analysis of this probe is also presented. To diminish the temperature sensitivity of the FBG sensor, we form multiple CFRPs onto the upper and lower layers of the FBG and package it with an epoxy resin. As a result, the depth of the CFRP is 1mm, and the temperature sensitivity is $2.39pm/^{\circ}C$. We construct a sensor network utilizing the fabricated sensor with a blade beam model. As the number of pendulums is increased on the fore-end of the beam, the strain value is measured. The strain variation is calculated from the measurement of the load on the blade beam model by monitoring the strain of the FBG sensor. When the linear equation is applied, the strain error is 0.4% and when the finite difference method is used, the tip deflection error is 3.3%. The displacement error derived from the strain value of the FBG sensor is 4.39%. The calculated result between the measured value of the dead-end of the beam and the strain is less than 2.46% tip distortion error. Therefore, our proposed multiplexing sensor probe is a low-cost and high-reliability solution for a commercial wind power generator.

Terminal Characteristics-Based IP Paging Strategy with Low Power Consumption for Wireless Sensor Networks (무선 센서 네트워크에 적합한 단말 특성 기반 저전력형 IP 페이징 기법)

  • Suh, Bong-Sue;Choi, Jin-Seek
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.10
    • /
    • pp.29-36
    • /
    • 2007
  • IP paging strategy, one of the solutions for derived problems in IP mobility support protocol, reduces the messages and the overheads over the network, since there is not registration procedure when a mobile terminal moves into a new router within the same paging area. However, the fact that the mobile terminals with the previous strategy consume electrical power continuously for paging signal reception obstructs the application of IP paging strategy to the IP-based wireless sensor networks. In this paper, we propose a discontinuous paging reception strategy based on the characteristics of the wireless sensor networks and their mobile terminals. As a result of the mathematical analysis, the proposed strategy significantly reduces the terminals' power consumption. In addition, by setting the relating parameters as appropriate values, the proposed strategy can be switched to the continuous reception strategy, or can be adjusted to limit the terminals' power consumption or paging delay.

A Study on The Modulation Method for Low Power Communication in Underwater Sensor Network (수중 센서 네트워크에서 저전력 통신을 위한 변조기법의 적용성 연구)

  • Jang, Chul-Hee;Han, Jeong-Woo;Kim, Ki-Man;Lee, Seong-Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6B
    • /
    • pp.689-696
    • /
    • 2011
  • In this paper, we propose the result of PSSK(Phase Silence Shift Keying) modulation scheme that is mixed PSK(Phase Shift Keying) modulation and PPM(Pulse Position Modulation) method. The performance of underwater communication systems are influenced underwater channel characteristics. In particular, delay spread can make ISI(Inter Symbol Interference) because of reverberation and multi path. It degrade the performance of the communication system. Also underwater sensor networks consider about power efficient due to the particularities of their operating environment. PSSK modulation method transmit two orthogonal symbol and using silence period in a period so it can reduce the power. Increasing the distance of between modulation symbols, to enhance the performance of BER(Bit Error Rate) as well as to improve power efficient. The result of sea trial, QPSK modulation BER is $3.19{\times}10^{-1}$ and PSSK modulation BER is $2.89{\times}10^{-1}$.

EMI Noise Source Reduction of Single-Ended Isolated Converters Using Secondary Resonance Technique

  • Chen, Zhangyong;Chen, Yong;Chen, Qiang;Jiang, Wei;Zhong, Rongqiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.403-412
    • /
    • 2019
  • Aiming at the problems of large dv/dt and di/dt in traditional single-ended converters and high electromagnetic interference (EMI) noise levels, a single-ended isolated converter using the secondary resonance technique is proposed in this paper. In the proposed converter, the voltage stress of the main power switch can be reduced and the voltage across the output diode is clamped to the output voltage when compared to the conventional flyback converter. In addition, the peak current stress through the main power switch can be decreased and zero current switching (ZCS) of the output diode can be achieved through the resonance technique. Moreover, the EMI noise coupling path and an equivalent model of the proposed converter topology are presented through the operational principle of the proposed converter. Analysis results indicate that the common mode (CM) EMI noise and the differential mode (DM) EMI noise of such a converter are deduced since the frequency spectra of the equivalent controlled voltage sources and controlled current source are decreased when compared with the traditional flyback converter. Furthermore, appropriate parameter selection of the resonant circuit network can increase the equivalent impedance in the EMI coupling path in the low frequency range, which further reduces the common mode interference. Finally, a simulation model and a 60W experimental prototype of the proposed converter are built and tested. Experimental results verify the theoretical analysis.