• Title/Summary/Keyword: low insolation

Search Result 64, Processing Time 0.027 seconds

A Study on Characteristics of Fluid Flow on Direct Absorption Receiver from Solar Energy (태양(太陽)에너지의 직접흡수식(直接吸收式) 수열판상(受熱板上)의 유체유동특성(流體流動特性)에 관(關)한 연구(硏究))

  • Pak, Ee-Tong
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.13-28
    • /
    • 1984
  • Direct Absorption Receiver and Thermal Storage System is a complex problem. This paper describes only characteristic of fluid flow on the receiver. The fluid thicknesses of Molten Salts (Melting Point : $397^{\circ}C$) flowing on the receiver of modified protopype ($10m{\times}10m$) were calculated theorectically, changing the receiver slope from 60 degree to 85 degree (5 steps). The receiver temperatures were $430^{\circ}C$ at the top part and $950^{\circ}C$ at the low part. The flow thickness of the Molten Salts at the top part of the receiver are around 1.9mm in the case of maximum insolution ($50{\times}10^6$juoule/sec; 58.898kg/sec of flow rate) and 2.0mm at the low part. In the case of 3/10 of maximum insolation (flow rate = 17.669kg/sec) the flow thickness at the top part are around 0.9mm and 0.4mm at the low part, and in the case of 1/10 of maximum insolation (flow rate = 5.889 kg/see) the flow thickness at the top part are around 0.6mm and 0.3mm at the low part. From experimental measurements of a normal fresh water thickness flowing on the model plate ($12.7cm{\times}111.76cm$), around 0.8mm at the top part of the plate and around 0.7mm at the low part were obtained in the case of maximum insolation (flow rate = 0.12496 kg/see). In the case of 3/10 (flow rate = 0.03748 kg/see) and 1/10 (flow rate = 0.012496 kg/see) of maximum insolation, around 0.5mm and 0.4mm at the top part, and around 0.3mm and 0.2mm at the low part were obtained respectively. The reason why the thickness of the Molten Salts increase at the low part of the receiver only in case of maximum insolation is that decreasing rate of the viscosity of the Molten Salts is larger than decreasing rate of the density of the Molten Salts during temperature increase from the top to the low receiver plate and decrease of the fluid velocity in accordance with continuity principle. In all cases without the above maximum insolation, the thickness of the Molten Salts and the fresh water decreased at the low part of the plate because of gravity force effects rather than friction effects and of continuity principle. All simillar flow patterns were obtained through all cases of the insolation making an exception of only maximum insolation.

  • PDF

A New Efficient Mppt Control Algorithm for Low Insolation Intensity

  • Yu, Gwon-Jong;Jung, Young-Seok;Park, Ju-Yeop
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.4
    • /
    • pp.214-218
    • /
    • 2002
  • In this paper, the effectiveness of three different control algorithms are thoroughly investigated via simulation and a proposed efficiency evaluation method of experimentation. Both the steady state and transient characteristics of each control algorithm along with its measured efficiency are analyzed. Finally, a novel two-mode maximum power point tracking (MPPT) control algorithm combining the constant voltage control and the incremental conduction (IncCond) methods is proposed to improve the efficiency of the 3KW PV power generation system at different insolation conditions. Experimental results show that the proposed two-mode MPPT control provides excellent performance at less than 30% insolation intensity, covering the whole insolation area without additional hardware circuitry.

Variation of the Insolation by Cloud Cover over Pusan in Korea (釜山地方의 雲量에 따른 日射量의 變化)

  • Cho, Byoung-Gil;Lee, Bu-Yong;Moon, Sung-Euii
    • Journal of Environmental Science International
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 1995
  • In order to examine the effect on the insolation of cloud cover, we analyzed the data of the insolation, cloud cover and surface air pressure in Pusan during the period of 1991. 10 - 1993.1. At first, we investigate the atmospheric transmissivity A(t) using the Beer's law at clear skies. The atmospheric transmissivity is characterized by cold season high and warn season low. From this atmospheric transmissivity, the empirical formula that shows the variation of the insolation due to the cloud cover is obtained. The result formula is I : l0 A(tn)·( 0.7-0.05×m ). 1 is the insolation that reaches the surface when cloud cover is m and to is solar constant. Although the result is some rough it seems meaningful that the estimation of insolation can be made only from the routine data.

  • PDF

A Study of MPPT Algorithm for Low Insolation (저일사강도에서 MPPT를 동작시키기 위한 알고리즘 연구)

  • Yu, Gwon-Jung;Jeong, Yeong-Seok;Kim, Gi-Hyeon;Choe, Ju-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.3
    • /
    • pp.142-149
    • /
    • 2002
  • As is well-known, the maximum power point (MPP) of PV power generation system depends on array temperature and solar insolation, it is necessary to track MPP of solar array all the time. Among various MPP control algorithms, the constant voltage control method, the perturbation and observation (P&O) method and the incremental conductance method (IncCond) have drawn many attractions due to the usefulness of each system. In this parer, the effectiveness of above mentioned three different control algorithms are thoroughly investigated via simulations and preposed efficiency evaluation method on experiment. Both the steady-state and transient characteristics of each control algorithms along with measured efficiency are analyzed, respectively. Finally, a novel MPPT control algorithm combining the constant voltage control and IncCond method for low insolation condition is proposed to improve efficiency of the 3KW PV power generation system.

A Study of MPPT algorithm for Low-insolation (저일사강도에서 MPPT를 동작시키기 위한 알고리즘 연구)

  • Kim, Ki-Hyun;Yu, Gwon-Jong;Jung, Young-Seok;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.473-475
    • /
    • 2001
  • This paper proposed a MPPT ( Maximum Power Point Tracking) control algorithm for PV(Photovoltaic) array based on a modified constant voltage control MPPT algorithm at low-insolation. This method which combines a IncCond(Incremental Conductance) and a constant voltage control algorithm. In contrast to the typical conventional MPPT algorithm, the proposed method have been obtained high efficiency and good performance. The proposed algorithm is verified through simulation result. In order to confirm the availability of the scheme, a simulation used PSIM and ACSL software tool.

  • PDF

A Study of New Highly Efficient MPPT Control Algorithm (새로운 고효율 MPPT 제어 알고리즘 고찰)

  • Yu, Gwon-Jong;Jung, Young-Seok;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.11-20
    • /
    • 2002
  • This paper proposed a MPPT(Maximum Power Point Tracking) control algorithm for PV(Photovoltaic) array based on a modified constant voltage control MPPT algorithm at low insolation. This method which combined a reference voltage control and a constant voltage control algorithm. In contrast to the typical conventional MPPT algorithm, the proposed method have been obtained high efficiency and good performance in all insolation intensity. The proposed algorithm is verified through simulation and experiment.

Estimation of Insolation over the Oceans around Korean Peninsula Using Satellite Data

  • Park, Kyung-Won;Kim, Young-seup;Sang, Chung-Hyo
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.227-230
    • /
    • 1999
  • Surface solar radiation over the sea is estimated using Visible and Infrared Spin Scan Radiometer data onbord Geostationary Meteorological Satellite(GMS) 5 for January, 1997 to December 1997 in clear and cloudy conditions. The hourly insolation is estimated with a spatial resolution of 5$\times$ 5 km grid. The island pyranometer belonging to the Japan Meteorological Agency is used for validation of the estimated insolation. It is shown that the estimated hourly insolation has RMSE(root mean square) error of 104 W/$m^2$. The variability of the hourly solar radiation was investigated on 3 areas over seas around Korean Peninsula. The solar radiation of East Sea is similar to Yellow Sea. The maximum value of solar radiation is on June of year. The maximum value in south sea is on August because weather is poor by low pressure and front in June

  • PDF

Development of Improved P&O Algorithm of PV System Considering Insolation variation (일사량 변화를 고려한 PV 시스템의 개선된 P&O 알고리즘 개발)

  • Ko, Jae-Sun;Choi, Jung-Sik;Kang, Sung-Jun;Jang, Mi-Geum;Baek, Jeong-Woo;Kim, Soon-Young;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.367-370
    • /
    • 2009
  • This paper proposes a novel maximum power point tracking(MPPT) control algorithm considering insolation to improve efficiency of PV system. The proposed algorithm is composed perturb and observe(P&O) method and constant voltage(CV) method. P&O method is simple to realize and CV method is possible to tracking MPP with low insolation. Response characteristics of proposed algorithm is compared to conventional P&O method with insolation variation. This paper proves the validity of proposed algorithm through the analysis result.

  • PDF

A novel MPPT control of photovoltaic considering insolation condition (일사량 조건을 고려한 태양광 발전의 새로운 MPPT 제어)

  • Jung, Byung-Jin;Ko, Jae-Sub;Choi, Jung-Sik;Kim, Do-Yeon;Jang, Mi-Geum;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1084_1085
    • /
    • 2009
  • This paper proposes a novel maximum power point tracking(MPPT) control algorithm considering insolation to improve efficiency of PV system. The propoed algorithm is composed perturb and observe(PO) method and constant voltage(CV) method. PO method is simple to realize and CV method is possible to tracking MPP with low insolation. Response characteristics of proposed algorithm is compared to conventional PO method with insolation variation. This paper proves the validity of proposed algorithm through the analysis result.

  • PDF

Characteristics of Air Pollution at Kimhae (김해지방의 대기오염 특성)

  • 박종길;김종필;김지형
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.33-43
    • /
    • 1999
  • This paper aims to describe the characteristics of air pollution using air pollutants concentration and meteorological data observed at Kimhae from December 1996 to November, 1997. The results are as follows : The concentration distribution of sulfur dioxide($SO_2$), carbon monoxide(CO), particulate matter(PM-10), and nitrogen dioxide($NO_2$) is high during the late fall and winter and low during the summer, but ozone concentration is low during the winter season and high during summer season except Jangma period and these distributions appear to be closely connected with insolation and the number of clear day. Diurnal variation of concentrations for sulfur dioxide, particulate matter, and carbon monoxide are high during the rush hours and nighttime and low during the daytime and these variations are distinct toward the winter season. And diurnal variation of nitrogen dioxide concentration has also same pattern and these patterns are closely related to the increasing traffic volume at rush hours. Diurnal variation of ozone concentration is generally increase for daytime and decrease for the late afternoon and are closely related to the insolation and photochemical reaction. The 24 hour average concentrations of air pollutant observed at Kimhae represented a positive correlation and a negative correlation for $O_3$ and also a negative correlation for the meteorological elements such as wind speed and cloud cover.

  • PDF