• Title/Summary/Keyword: low cement mortar

Search Result 198, Processing Time 0.031 seconds

A Study on the Dynamic Properties of Cement Mortar with Recycled PET Fiber (폐PET섬유를 혼입한 시멘트모르터의 역학적 특성에 관한 연구)

  • 김영근;김상철;김명훈
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.77-86
    • /
    • 2002
  • In this study we intended to investigate properties of cement mortar with recycled PET fiber, PE fiber, and PP fiber such as slump flow, compressive strength, tensile strength, and flexural strength. As results of experiment, several properties of specimen with recycled PET fiber were little low comparing those of specimen with PE fiber and PP fiber. But if we see from point of economy and recycle of industrial wastes, it has enough reason to be used. Compressive strength of specimen with recycled PET fiber at 56 days was about 10% higher, but tensile strength and flexural strength were lower than that of no-fiber.

  • PDF

Freeze and MechanicalProperties of Cement Mortar Using Coolant Wasted (폐부동액을 이용한 시멘트 모르터의 동결 및 역학적 특성)

  • Kim, Sang-Woo;Hong, Sang-Hee;Kim, Gi-Cheol;Ryu, Hyun-Ki;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.169-172
    • /
    • 2000
  • In this paper applicabilities of coolant wastes are an admixture, which are produced from cooling line of the cars and industrial engines, to concrete under cold climate are investigated. According to the test results, as the contents f coolant wastes increase, setting time of cement mortar is shown to be delayed. However, when coolants wastes are overadded, it appears to be fast. In case of compressive strength, It tends to decline as the contents of coolant waste increase. Under low curing temperature, compressive strength of cement mortar containing coolant wasted with the increase of the contents of coolants wastes.

  • PDF

A STUDY ON THE PROPERTIES OF HARDENED CEMENT MORTAR MIXED WITH WASTE INCINERATED ASH (쓰레기 소각재를 혼입한 시멘트 경화체의 특성에 관한 연구)

  • 이승한;정용욱;한형섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.190-195
    • /
    • 1997
  • The purpose of this study was to use daily waste incinerated ash, which was reclaimed worthlessly, as substitutes of fine aggregates in concrete. Various kinds of admixture was utilized to strengthen the cement mortar mixed with waste incinerated ash, and altered the curing condition to diminish the rate of expansion. By the results of this experiment, it was possible to produce the lightweight concrete, charactered with the gravity below 1.5 and over 160kg/$\textrm{cm}^2$ compressive strength by replacing all fine aggregates with waste incinerated ash. It was also observed that the low temperature curing condition, lessoned gas exhausts, was effective to increase the strength of cement mortar.

  • PDF

Shear Strength and Deformation Behavior of Rock Joint with Roughness (절리면의 거칠기에 따른 암석 절리의 전단강도 및 변형거동에 관한 연구)

  • 이상돈;강준호;이정인
    • Tunnel and Underground Space
    • /
    • v.4 no.3
    • /
    • pp.261-273
    • /
    • 1994
  • Direct shear tests were carried out on the rock joints and artificial discontinuities to investigate the influence of joint roughness on the shear strength and deformation behaviour. Single direct shear testing apparatus used in experiment was designed and manufactured. Its capacity is 200 tons of shear load, 20 tons of normal load and 50$\textrm{cm}^2$ of maximum shear area. Test samples were cement mortar with artificial discontinuity and sandstone with natural joint. Peak shear strength was increased as joint roughness or normal stress was increased, especially, linearly increased with roughness angle in cement mortar. If joint roughness angle was constant at low normal stress, shear strength was not affected by width and height of joint roughness in cement mortar. Peak shear strengths obtained from tests were larger than the values calculated by Barton's equation, and shear stiffness was increased with joint roughness coefficient.

  • PDF

A Study on the Dynamic Properties of Cement Mortar with Recycled PET Fiber (폐PET섬유를 혼입한 시멘트모르터의 역학적 특성에 관한 연구)

  • Kim, Young-geun;Kim, Sang-cheol;Kim, Myung-hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.4
    • /
    • pp.113-122
    • /
    • 2002
  • In this study we intended to investigate properties of cement mortar with recycled PET fiber, PE fiber. and PP fiber such as slump flow, compressive strength, tensile strength, and flexural strength. At results of experiment. several properties of specimen with recycled PET fiber were little low comparing those of specimen with PE fiber and PP fiber. But if we see from point of economy and recycle of industrial wastes, it has enough reason to be used. Compressive strength of specimen with recycled PET fiber at 55 days was about 10% higher. but tensile strength and flexural strength were lower than that of no-fiber.

Compressive strength behaviour of low-strength hollow concrete block masonry prisms

  • Syiemiong, Hopeful;Marthong, Comingstarful
    • Structural Engineering and Mechanics
    • /
    • v.80 no.6
    • /
    • pp.689-699
    • /
    • 2021
  • The present study aims to understand the behaviour of low-strength masonry prisms constructed with locally-produced low-strength hollow concrete blocks. Compression tests were conducted on masonry prisms constructed with three different mortar grades of cement-sand ratios of 1:3, 1:4.5 and 1:6 representing strong, moderately strong and weak mortar. Stress-strain curves were generated from the test results for the masonry prisms. The hollow concrete masonry units employed in this study are some of the weakest as compared to other masonry units employed by other researchers. The compressive strengths for masonry prisms with mortar grades 1:3, 1:4.5 and 1:6 are 2.21 MPa, 2.19 MPa and 2.25 MPa respectively. The results indicate that the masonry compressive strength of such low-strength hollow concrete block masonry prisms is not influenced by the mortar strength. Simple relationships to estimate the modulus of elasticity and compressive strength of masonry prisms is also proposed.

PCM mixed the amount of Thermal Conductivity of Cement mortar Experimental Study on the effect. (PCM 혼입량이 시멘트 모르타르의 열전도율에 미치는 영향에 관한 실험적 연구)

  • Jeong, You-Gun;Kim, Bo-Hyun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.245-246
    • /
    • 2011
  • In recent research in this emerging and latent heat storage material features an innovative temperature - controlled Phase Change Materials to evaluate the superior thermal performance would like to calculate the thermal conductivity. Specified in KS F 4040 test specimen dimensions were equivalent in specifications, test methods according to KS L 9016 was an experiment in progress. As a result, the thermal conductivity of plain cement mortar mixed with more PCM came out with low thermal conductivity of mortar, thermal performance was excellent.

  • PDF

An Experimental Study on the Early Compressive Strength Improvement of Cement Mortar Mixed with Blast Furnace Slag using Powdered Stimulants (분말형 자극제를 이용한 고로슬래그미분말 혼입 시멘트 모르타르의 조기 압축강도 향상에 관한 실험적 연구)

  • Lee, Kang Jin;Kim, Jin Hyoung;Park, Ki Bong;Lee, Han Seung
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.115-122
    • /
    • 2012
  • Based on previous research and existing literature, this study examines the development of admixture, which increases the early concrete strength (1 and 3 day) by mixing blast furnace slag cement and concrete stimulant. The research on early strength development of concrete is necessary in dealing with the drawbacks of slow early strength concrete on site and to shorten the construction time. The study confirmed that when a high alkaline mortar mixture is mixed with blast furnace slag, the early strength of admixture exceeds that of ordinary portland cement (OPC). The use of calcium chloride ($CaCl_2$) promotes hydration of cement at low temperature and show similar strength as the blast furnace slag admixture. Although calcium chloride seems economically advantageous, it causes steel corrosion and its use in concrete should be further studied in-depth.

Application of Ferronickel Slag Aggregate to Improve Workability and Strength of Non-Sintered Cement Mortar (비소성 시멘트 모르타르의 작업성 및 강도 개선을 위한 페로니켈슬래그 골재의 적용방안)

  • Jang, Kyung-Soo;Na, Hyeong-Won;Hyung, Won-Gil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.309-310
    • /
    • 2023
  • Slag and ash generally have a higher powder degree than portland cement, so workability may deteriorate under the same unit quantity condition, and strength and durability decrease when the unit quantity is increased. At this time, if an aggregate having a low water absorption and an appropriate particle size is used to recover the loss of strength, it can contribute to reducing the unit quantity of the binder. Therefore, for the purpose of improving the workability and strength of non-sintered cement mortar using slag and ash, ferro nikel slag whose particle size was adjusted was used as an aggregate and its applicability was identified. In this experimental condition, it was confirmed that non-sintered cement mortar tends to improve workability and secure strength when ferro nikel slag having various particle size distributions is used as an aggregate. This can be analyzed as the effect of ferro nikel slag material properties including glassy properties and mixing conditions with a wide particle size distribution.

  • PDF

Heating Transferring Charcteristics of Cement Mortar Block with Waste CNT and Conduction Activator (폐CNT와 전도촉진재를 혼입한 시멘트 모르타르 블록의 발열 전도 특성)

  • Koo, Hounchul;Kim, Woon-Hak;Oh, Hongseob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.2
    • /
    • pp.176-183
    • /
    • 2022
  • High-purity waste CNTs were mixed into cement mortar to manufacture heat-generating concrete that can use low voltage power, and carbon fiber and waste cathode materials were also used improve the conductivity of the mortar. The waste CNTs were analyzed to have a high concentration of multi-walled CNTs, and substituted liquid type waste CNTs were used during mortar mixing in order to increase dispersibility. The temperature change of the mortar with CNT was evaluated when using electric power below DC 24 V in order to utilize a small self-generation facility such as small solar power module when the mortar heats up and to minimize electromagnetic waves. When liquid-type waste CNTs were applied and a voltage of DC 24 V was introduced, it rose to 60 ℃ in a 200 × 100 × 50 mm mortar block specimen. The field applicability of self heating mortar with waste CNT was sufficient and also the amount of change in heat energy in mortar with liquid type waste CNT, carbon fiber and waste cathode materials is more effective compared to it of other variables.