• Title/Summary/Keyword: loss frequency

Search Result 3,558, Processing Time 0.026 seconds

Study on the Power Loss of High Frequency Mn-Zn ferrites (고주파 Mn-Zn ferrites 전력손실에 대한 고찰)

  • 서정주
    • Resources Recycling
    • /
    • v.11 no.5
    • /
    • pp.34-38
    • /
    • 2002
  • To minimize the size of transformer volume, the operating frequency of ferrites cores increasing. The power loss of Mn-Zn ferrites comprises hysteresis loss, eddy current loss and residual loss. In the range more then 500 KHz, the total power loss is mainly due to the residual loss. The power loss increase with the frequency 3rd power. To minimize residual loss as well as eddy current loss, the microstructure should have small grain and high density, It should be noted that as the product of resonance frequency and static permeability increase, the power loss decrease at high frequency region.

Magnetic Loss of Mn-Zn Ferrite Cores Used for SMPS (SMPS용 Mn-Zn 페라이트 코어의 자기손실 특성)

  • 권태석;김성수
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.3
    • /
    • pp.149-153
    • /
    • 1999
  • Frequency and temperature dependence of magnetic loss has been investigated in Mn-Zn ferrites containing the sesistive temary compounds of $SiO_2-CaO-V_2O_5$. The Mn-Zn ferrite with the composition of $MnO:ZnO:Fe_2O_3=36:11:53$(by mol %) are prepared by self-propagating high-temperature synthesis. From the results of frequency dependence of core loss, it has been found that the hysteresis loss is dominant at low frequency and the eddy current loss becomes more dominant as the frequency increases. With the addition of resistive compound, the frequency dependence of core loss, it has been found that the hysteresis loss is dominant at low frequency and the eddy current loss becomes more dominant as the frequency increases. With the addition of resistive compound, the frequency region where the hysteresis loss is dominant becomes wide. The core-loss minimum occurs at about 4$0^{\circ}C$ in the specimens with the additive because of the reduction in eddy current loss.

  • PDF

Development of Core Material with High Magnetic Induction and Low Iron Loss for Middle-Frequency Applications (고자속밀도와 저손실 특성을 갖는 중주파수대 철심재료 개발 및 응용)

  • Cho, Seong-Soo;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.190-195
    • /
    • 2009
  • Thin-gauged 3% silicon steel sheets having a highly grain-oriented texture have been developed as a core material for applications of middle-frequency (400 Hz ${\sim}$ 10 kHz) devices. The newly developed sheets with a tension coating showed an excellent reduction in iron loss at 400 Hz (iron loss at 1.0 T and 400 Hz = 4.677 W/kg, iron loss at 1.5 T and 400 Hz = 9.742 W/kg) due to high magnetic induction, $B_{10}$(measured induction at 1000 A/m), of over 1.9 T. In cases of frequencies below 400 Hz, magnetic induction, $B_{10}$, of the sample plays a major role to reduce its iron loss as excitation induction increases, whereas, in case of frequency of 1 kHz, thickness dependence becomes dominant due to a lower iron loss at relatively thinner sample. The sheets with a high magnetic induction, therefore, are favorable for high excitation induction (over 1.0 T) and low excitation frequency (below 400 Hz) applications, whereas the sheets that can reduce eddy current loss by reducing thickness or domain wall width are advantageous for low excitation induction (below 1.0 T) and high excitation frequency (around 1 kHz) applications.

The Estimation Method Comparison of Iron Loss Coefficients through the Iron Loss Calculation

  • Kim, Yong-Tae;Cho, Gyu-Won;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1409-1414
    • /
    • 2013
  • A new calculation method for iron loss coefficients is proposed by using the Steinmetz equation from Epstein data. The hysteresis loss must have linear characteristic according to the frequency. However, the existing iron loss coefficients are defined by formula of frequency. In this case, the hysteresis loss has non-linear characteristics by frequency. So, in this paper, the iron loss coefficients were defined by a function of the magnetic flux density, and the iron loss calculation is applied for Interior Permanent Magnet Synchronous Motor(IPMSM) of 600(W) and 200(W). The iron loss calculation results and the experimental results are compared according to the various materials.

Study on the Robust Design of an Intake System Using a Frequency Weighting Function (주파수 가중함수를 적용한 흡기계의 강건설계 연구)

  • Lee, J.K.;Park, Y.W.;Chai, J.B.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.680-686
    • /
    • 2005
  • This paper introduces the robust design of an intake system using transmission loss and the frequency weighting function. First, transmission loss is measured to evaluate the performance of the noise reduction for the intake system. The robust design parameters of the intake system are extracted by adapting a cost function with the Taguchi method. Subsequently, the frequency weighting function is developed by the subjective evaluation in which 6 special engineers were participated. Finally, the comparison between the proposed frequency weighted optimal design and unweighted optimal design for the transmission loss as the part is performed. Here, the overall levels of the transmission loss according to the methods are presented to validate the effectiveness of the proposed methodology.

Power Loss Analysis according to Winding Array Method of High Frequency Transformer (고주파 트랜스포머의 권선배열에 기법 따른 손실해석)

  • Yoon, Shin-Yong;Kim, IL-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.15-19
    • /
    • 2005
  • This paper analyzed the power loss characteristics according to winding thickness and winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM tool. The ferrite core model for analysis be used the EE10 type of TDK cop.. Transformer model objected flyback transformer type applied to flyback converter/inverter. Therefore, analysis results of loss were obtained from inner parameters of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

Contact Loss Simulator to Analyze the Contact Loss of a Rigid Catenary System

  • Jung, No-Geon;Kim, Jae-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1320-1327
    • /
    • 2017
  • In this paper, a contact loss simulator for a rigid catenary system was designed and used to analyze the effect on the power source according to the conditions of the rigid catenary system and pantograph. R-bar applied to a high-speed train among the real rigid catenary system was used in the contact loss simulator for rigid catenary systems. The excitation frequency generated with the movement of the railway vehicle was simulated. The characteristics according to the frequency and amplitude of the excitation frequency and the presence or absence of pantograph movement were analyzed. This work is considered to be helpful in analyzing the characteristics of contact loss in the interface between a real rigid catenary system and a rail vehicle.

Genetic Hearing Loss and Gene Therapy

  • Carpena, Nathanial T;Lee, Min Young
    • Genomics & Informatics
    • /
    • v.16 no.4
    • /
    • pp.20.1-20.20
    • /
    • 2018
  • Genetic hearing loss crosses almost all the categories of hearing loss which includes the following: conductive, sensory, and neural; syndromic and nonsyndromic; congenital, progressive, and adult onset; high-frequency, low-frequency, or mixed frequency; mild or profound; and recessive, dominant, or sex-linked. Genes play a role in almost half of all cases of hearing loss but effective treatment options are very limited. Genetic hearing loss is considered to be extremely genetically heterogeneous. The advancements in genomics have been instrumental to the identification of more than 6,000 causative variants in more than 150 genes causing hearing loss. Identification of genes for hearing impairment provides an increased insight into the normal development and function of cells in the auditory system. These defective genes will ultimately be important therapeutic targets. However, the auditory system is extremely complex which requires tremendous advances in gene therapy including gene vectors, routes of administration, and therapeutic approaches. This review summarizes and discusses recent advances in elucidating the genomics of genetic hearing loss and technologies aimed at developing a gene therapy that may become a treatment option for in the near future.

Implementation of Low Loss Radome with Hexa mesh for Ku-Band

  • Seo, Kang;JeongJin, Kang
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.555-560
    • /
    • 2022
  • In this study, the insertion loss and phase delay according to the multi-layer structure radome parameters were analyzed using the boundary value solution approach, and the multi-layer structure and hexa mesh structures with low-loss electrical characteristics for the Ku-band transmission/reception frequency of 10.7 ~ 14.5 GHz were designed and manufactured. A hexa mesh was applied to minimize radio wave transmission and scattering, which lowered the transmittance refractive index according to the radio incident angle and minimized dielectric loss through high-density foam. Similar to the simulation result, the transmission loss obtained the gain in a specific receiving frequency band, and in the transmission frequency band, an excellent low loss characteristic was obtained with an insertion loss of 0.8dB or less. The results of this study can be used in radio transmission radomes of low-weight, low-cost end-system protection devices.

Measurements of mid-frequency transmission loss in shallow waters off the East Sea: Comparison with Rayleigh reflection model and high-frequency bottom loss model (동해 천해환경에서 측정된 중주파수 전달손실 측정: Rayleigh 및 HFBL 모델과의 비교)

  • Lee, Dae Hyeok;Oh, Raegeun;Choi, Jee Woong;Kim, Seongil;Kwon, Hyuckjong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.297-303
    • /
    • 2021
  • When sound waves propagate over long distances in shallow water, measured transmission loss is greater than predicted one using underwater acoustic model with the Rayleigh reflection model due to inhomogeneity of the bottom. Accordingly, the US Navy predicts sound wave propagation by applying the empirical formula-based High Frequency Bottom Loss (HFBL) model. In this study, the measurement and analysis of transmission loss was conducted using mid-frequency (2.3 kHz, 3 kHz) in the shallow water of the East Sea in summer. BELLHOP eigenray tracing output shows that only sound waves with lower grazing angle than the critical angle propagate long distances for several kilometers or more, and the difference between the predicted transmission loss based on the Rayleigh reflection model and the measured transmission loss tend to increase along the propagation range. By comparing the Rayleigh reflection model and the HFBL model at the high grazing angle region, the bottom province, the input value of the HFBL model, is estimated and BELLHOP transmission loss with HFBL model is compared to measured transmission loss. As a result, it agrees well with the measurements of transmission loss.