• Title/Summary/Keyword: loop element

Search Result 276, Processing Time 0.034 seconds

The Implementation and Experiments of Open-Loop Cylindrical Vibratory Gyroscope (개루프 제어의 실린더 진동형 자이로 구현 및 실험)

  • 공형직;김정엽;홍성경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.8
    • /
    • pp.669-672
    • /
    • 2004
  • This paper considers the implementation and experiments of an open-loop Cylindrical Vibratory Gyroscope(CGV). An open-loop CGV composed of thin cylindrical vibrating element, electromagnetic drive and pick-off element with open-loop control was designed and fabricated. The experimental performance tests of the open-loop CGV were done using a temperature chambered rate table. Also, the limitations of open-loop CGV were analyzed and the solution for the limitations was proposed.

MECHANICAL ANALYSIS OF THE PATTERN OF MOVEMENT DURING RETRACT10N OF MAXILLARY INCISORS BY SPACE CLOSING LOOP (Space closing loop에 의해 야기되는 상악 절치부 이동양상에 관한 역학적 연구)

  • Min, Sang-Hong;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.143-152
    • /
    • 1995
  • This study was performed, by Finite Element Method, to evaluate the stress distribution on the periodontal tissue according to activation of the various closing loops and to predict the pattern of movement of maxillary incisors. At the same time, bull loop, key-hole loop, T-loop, combination loop and asymmetrical T-loop which were used for retraction of maxillary incisors was analysed by Finite Element Method. The following results were obtained 1. Horizontal force was the greatest in bull loop, the followed by key-hole loop, combination loop, T-loop and initial tooth movement exhibited uncontrolled tipping. 2. Horizontal force in asymmetrical T-loop compared to other closing loops was remarkably decreased, and the intrusive force on the incisors occurred. 3. As torque was increased, the moment was increased as a linear increment. 4. As moment was increased, initial movement of tooth changed to root movement from uncontrolled tipping.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS FOR REACTION TO MOLAR UPRIGHTING SPRING (대구치 직립 스프링 적용시 반작용에 관한 삼차원 유한요소법적 연구)

  • Choe, Yoo-Kyung;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.61-74
    • /
    • 1998
  • The Purpose of this study was to investigate the stress distribution and tooth displacement at the initial phase produced by 5 types of molar uprighting springs using finite element method. The three dimensional finite element model of lower dentition, bone and springs was composed of 5083 elements and 2071 nodes. The results were as follows: 1. In case of helical spring and root spring, intrusion of lower canine and first premolar were observed md distal tipping, translation and extrusion of lower second molar were observed. 2. In case of T-loop, modified T-loop and box loop, intrusion and distal translation of lower second premolar were observed, and the largest crown distal tipping and translation of lower second molar were observed in T-loop and the smallest were observed in box loop. 3. In case of T-loop with cinch-bact crown distal tipping and translation of lower second molar were decreased, but extrusion was also decreased. 4. With increase of activation in T-loop, mesial translation and won distal tipping of lower second molar were increased and edentulous space was closing, but distal translation of second premolar was also increased. 5. With increase of tip-back bend in T--loop, distal tipping and translation of lower second molar were increased, but extrusion was also increased more largely.

  • PDF

Finite element analysis for dynamic behavior of a machine tool structure fed in open loop control (개루프제어로 이송되는 공작기계 구조물의 동적 거동을 위한 유한 요소 해석)

  • Choi, Jin-Woo;Lee, Tae-Hong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.5
    • /
    • pp.596-602
    • /
    • 2010
  • In this study, a fmite element model was developed for analysis of feeding a structure in open loop control The finite element analysis (FEA) can simulate dynamic behavior of the structure of a machine tool rapidly traveling with a screw feeding driving system. The feeding mechanism was implemented with screw element of the FEA tool used in this study. The procedure was developed for the dynamic transient FEA. First, motion parameters such as jerk and velocity were introduced for the structure to be fed in open loop control When its traveling distance was determined, set-points for the distance were generated based on the motion parameters. The set-points were applied to the FE model constructed for the traveling structure. The FEA was executed and evaluated. In this study, the FEA procedure was applied to the column of a machine tool and the dynamic behavior of the column was evaluated. The FEA helps in evaluation of the motion characteristics of a structure. The convergence time of the structure vibration posterior to feeding termination can be estimated and the stiffness of the flexible structure is also evaluated against jerk, and acceleration. It provides the feeding force which is helpful in selection of the feeding motor.

The Comparison of Field Uniformity and SAR between TEM, Loop and Combined Elemented 16 Channel Transmit Arrays (TEM 형과 Loop 형의 전송소자를 이용한 16채널 3T Body 전송코일의 자장 균일도와 안전도 비교)

  • Ryu, Yeunchul;Kim, Young Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.404-408
    • /
    • 2014
  • In this research we evaluate the excitation homogeneity and SAR of three different Tx arrays after B1+ Shimming in the human body at 3T. Through the simulations, we compared the field properties that are standard deviation and mean value of transverse magnetization for 1) strip line TEM array, 2) rectangular loop array, 3) combined array of strip line element and rectangular loop and shown the utilities of B1+ shimming in human body model. After B1+ shimming, it is evaluated four different types of SAR for body mesh through whole body simulation; those are average, maximum 1-cell, maximum 1-gram, and maximum 10-gram SAR. It appears that in this particular comparison an array based on strip line elements can produce better homogeneity and lower SAR than an array of rectangular loops or an array of combined elements (strip line and loop). While many factors are considered in designing coils for production, it is hoped that methods and results like these will be used in the future to guide decisions and maximize benefit.

A Performance Study of First-order Shear Deformable shell Element Based on Loop Subdivision Surface (루프서브디비전 곡면을 이용한 일차전단 변형 쉘요소의 성능에 관한 연구)

  • 김형길;조맹효
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.261-268
    • /
    • 2003
  • A first order shear deformable Loop-subdivision triangular element which can handle transverse shear deformation of moderately thick shell is developed. The developed element is general since it includes the effect of transverse shear deformation and has standard six degrees of freedom per node.(three translations and three rotations) The quartic box-spline function is employed as interpolation basis function. Numerical examples for the benchmark problems are analyzed in order to assess the performance of the newly developed subdivision shell element. Both in the uniform and in the distorted mesh configurations.

  • PDF

Generation of Subdivision Surface and First-order Shear Deformable Shell Element Based on Loop Subdivision Surface (서브디비전의 다중해상도 기능을 이용한 곡면의 모델링과 유한요소 해석)

  • 김형길;서홍석;조맹효
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.2
    • /
    • pp.151-160
    • /
    • 2004
  • In the present study, Loop scheme is applied to generate smooth surfaces. To be consistent with the limit points of target surface, the initial sampling points are properly rearranged. The pointwise errors of curvature and position in the sequence of subdivision process are evaluated in the Loop subdivision scheme. A first-order shear deformable Loop subdivision triangular element which can handle transverse shear deformation of moderately thick shell are developed. The developed element is more general than the previous one based on classical shell theory, since the new one includes the effect of transverse shear deformation and has standard six degrees of freedom per node. The quartic box spline function is used as interpolation basis function. Numerical examples for the benchmark static shell problems are analyzed to assess the performance of the developed subdivision shell element and locking trouble.

The Design of PI controller using a saturation function in frequency domain (포화함수를 이용한 주파수영역에서의 PI제어기설계)

  • Oh, Seung-Rohk
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.326-328
    • /
    • 2009
  • we an autotuning algorithm for PI controller with unknown plant. The proposed algorithm uses a saturation function and time delay element as a test signal. Since the integral element of PI controller reduces a phase margin and amplitude margin in the closed loop system, the closed loop system could be resulted in unstable with PI controller, To avoid unstable in the closed loop system with PI controller, the proposed algorithm identifies one point information in the 3rd quadrant of Nyquist plot with a time delay element. The proposed method improves an accuracy of one point identified information with one saturation function.

  • PDF

A Register-Controlled Symmetrical Delay Locked Loop using Hybrid Delay Line (하이브리드 딜레이 라인을 이용한 레지스터 콘트롤 Symmetrical Delay Locked Loop)

  • 허락원;전영현
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.87-90
    • /
    • 2000
  • This paper describes a register-controlled symmetrical delay-locked-loop (DLL) using hybrid delay line for use in a high frequency double-data-rate DRAM. The proposed DLL uses a hybrid delay line which can cover two-step delays(coarse/fine delay) by one delay element. The DLL dissipate less power than a conventional dual-loop DLL which use a coarse and a fine delay element and control separately. Additionally, this DLL not only achieves small phase resolution compared to the conventional digital DLL's when it is locked but it also has a great simple delay line compared to a complex dual-loop DLL.

  • PDF

Interval finite element method for complex eigenvalues of closed-loop systems with uncertain parameters

  • Zhang, XiaoMing;Ding, Han
    • Structural Engineering and Mechanics
    • /
    • v.26 no.2
    • /
    • pp.163-178
    • /
    • 2007
  • In practical engineering, the uncertain concept plays an important role in the control problems of the vibration structures. In this paper, based on matrix perturbation theory and interval finite element method, the closed-loop vibration control system with uncertain parameters is discussed. A new method is presented to develop an algorithm to estimate the upper and lower bounds of the real parts and imaginary parts of the complex eigenvalues of vibration control systems. The results are derived in terms of physical parameters. The present method is implemented for a vibration control system of the frame structure. To show the validity and effectiveness, we compare the numerical results obtained by the present method with those obtained by the classical random perturbation.