• Title/Summary/Keyword: long-term failure analysis

Search Result 246, Processing Time 0.028 seconds

Evaluation of Insulation Deterioration for the Development of SVM Algorithm to Diagnose OF Cable (OF 케이블 진단용 SVM 알고리즘 개발을 위한 절연열화 평가)

  • Kwak, Byeong Sub;Jun, Tae-Hyun;Kim, Ah-Reum;Park, Hyun-joo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.263-273
    • /
    • 2019
  • South Korea's OF cable is reaching its expected design life of 30 years, and as a result, the risk of failure is increasing. Therefore, it is necessary to diagnose the long-term operating OF cables through accurate diagnosis at the right time to prevent the failure. Currently, the KEPCO periodically conducts DGA. However, the gas found in DGA is caused by oil deterioration as well as insulation paper. Therefore, the analysis of the degree of polymerization and furan compounds which is an evaluation of insulation paper considered to be the life of OF cables is required. In addition, the results of the evaluation of deterioration of insulation paper need to be checked for correlation with the results of DGA. In this study, DGA carried out through GC, the degree of polymerization was analyzed using an automatic viscometer, and HPLC was used to detect the furan compounds. In addition, the obtained results were applied to the SVM technique, which was recently introduced to determine abnormalities in OF cable. And the results which were accurate and reliable were obtained.

Numerical Simulation of Full-Scale Crash Impact Test for Fuel Cell of Rotorcraft (회전익항공기 연료셀 충돌충격시험 Full-Scale 수치모사)

  • Kim, Hyun-Gi;Kim, Sung Chan;Kim, Sung Jun;Kim, Soo Yeon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.5
    • /
    • pp.343-349
    • /
    • 2013
  • Crashworthy fuel cells have a great influence on improving the survivability of crews. Since 1960's, the US army has developed a detailed military specification, MIL-DTL-27422, defining the performance requirements for rotorcraft fuel cells. In the qualification tests required by MIL-DTL-27422, the crash impact test should be conducted to verify the crashworthiness of fuel cell. Success of the crash impact test means the improvement of survivability of crews by preventing post-crash fire. But, there is a big risk of failure due to huge external load in the crash impact test. Because the crash impact test itself takes a long-term preparation efforts together with costly fuel cell specimens, the failure of crash impact test can result in serious delay of a entire rotorcraft development. Thus, the numerical simulations of the crash impact test has been required at the early design stage to minimize the possibility of trial-and-error with full-scale fuel cells. Present study performs the numerical simulation using SPH(smoothed particle hydro-dynamic) method supported by a crash simulation software, LS-DYNA. Test condition of MIL-DTL-27422 is reflected on analysis and material data is acquired by specimen test of fuel cell material. As a result, the resulting equivalent stresses of fuel cell itself are calculated and vulnerable areas are also evaluated.

The Extent of Late Gadolinium Enhancement Can Predict Adverse Cardiac Outcomes in Patients with Non-Ischemic Cardiomyopathy with Reduced Left Ventricular Ejection Fraction: A Prospective Observational Study

  • Eun Kyoung Kim;Ga Yeon Lee;Shin Yi Jang;Sung-A Chang;Sung Mok Kim;Sung-Ji Park;Jin-Oh Choi;Seung Woo Park;Yeon Hyeon Choe;Sang-Chol Lee;Jae K. Oh
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.324-333
    • /
    • 2021
  • Objective: The clinical course of an individual patient with heart failure is unpredictable with left ventricle ejection fraction (LVEF) only. We aimed to evaluate the prognostic value of cardiac magnetic resonance (CMR)-derived myocardial fibrosis extent and to determine the cutoff value for event-free survival in patients with non-ischemic cardiomyopathy (NICM) who had severely reduced LVEF. Materials and Methods: Our prospective cohort study included 78 NICM patients with significantly reduced LV systolic function (LVEF < 35%). CMR images were analyzed for the presence and extent of late gadolinium enhancement (LGE). The primary outcome was major adverse cardiac events (MACEs), defined as a composite of cardiac death, heart transplantation, implantable cardioverter-defibrillator discharge for major arrhythmia, and hospitalization for congestive heart failure within 5 years after enrollment. Results: A total of 80.8% (n = 63) of enrolled patients had LGE, with the median LVEF of 25.4% (19.8-32.4%). The extent of myocardial scarring was significantly higher in patients who experienced MACE than in those without any cardiac events (22.0 [5.5-46.1] %LV vs. 6.7 [0-17.1] %LV, respectively, p = 0.008). During follow-up, 51.4% of patients with LGE ≥ 12.0 %LV experienced MACE, along with 20.9% of those with LGE ≤ 12.0 %LV (log-rank p = 0.001). According to multivariate analysis, LGE extent more than 12.0 %LV was independently associated with MACE (adjusted hazard ratio, 6.71; 95% confidence interval, 2.54-17.74; p < 0.001). Conclusion: In NICM patients with significantly reduced LV systolic function, the extent of LGE is a strong predictor for long-term adverse cardiac outcomes. Event-free survival was well discriminated with an LGE cutoff value of 12.0 %LV in these patients.

The Effects of Technology Commercialization Capability and Competitive Strategy of Venture Companies on Growth Prospects: Focused on Mediating Effect of Business Model Innovation (벤처기업의 기술사업화역량과 경쟁전략이 성장전망에 미치는 영향: 비즈니스모델 혁신의 매개효과를 중심으로)

  • Ahn, Mun Hyoung
    • Journal of Industrial Convergence
    • /
    • v.20 no.8
    • /
    • pp.1-13
    • /
    • 2022
  • Although the number of venture start-ups has increased significantly, it is difficult to judge the success or failure based on short-term performance alone. The survival of a company cannot be guaranteed if it does not show sustainable growth prospects. As a growth factor for venture companies, the level of technology commercialization capability and competitive strategies are considered important. Recently, the emergence of innovative business models is creating new opportunities and driving the growth of numerous venture start-ups. This study tried to investigate the mediating effect of business model innovation in the relationship between technology commercialization capability, competitive strategy and the growth prospects of venture companies. For this, empirical analysis was conducted using the original data of the Research on the Precision Status of Venture Firms 2021. As a result, production, manufacturing, marketing capability, cost leadership and product differentiation had a positive(+) effect on growth prospects. The mediating effect of business model innovation between all factors except for manufacturing capacity and growth prospects was verified. This study expanded the scope of research by shedding new light on the factors influencing the long-term growth prospects of venture companies and revealing business model innovation as a new mediating variable. In future research, it is necessary to develop an objective measurement tool and to identify differences according to industrial characteristics.

Clinical Investigation of Tuberculous Pneumonia (결핵성 폐렴환자의 임상적 고찰)

  • Lee, Seung Heon;Hur, Gyu Young;Jung, Ki Hwan;Lee, Sung Yong;Lee, Sang Yeub;Kim, Jae Hyung;Park, Sang Myun;Shin, Chul;Shim, Jae Jeong;In, Kwang Ho;Kang, Kyung Ho;Ryu, Sae Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.1
    • /
    • pp.19-24
    • /
    • 2004
  • Background : It is difficult to differentiate between tuberculous pneumonia and Community Acquired Pneumonia, so the diagnosis and treatment of tuberculous pneumonia can be delayed frequently. In this study, we attempted to retrospectively evaluate the clinical and radiologic characteristics of tuberculous pneumonia. Methods : We conducted a retrospective analysis of clinical characteristics of 58 patients diagnosed with tuberculous pneumonia from Nov. 1997 to May 2001 at Korea university kuro hospital. Result : The male to female ratio was 1:1 and the mean age at diagnosis was $54.5{\pm}18.6$ years. Fifty five patients were confirmed microbiologically and three patients pathologically. There were 20 patients(34.5%) who had diabetes mellitus(8cases), chronic obstructive pulmonary disease(3cases), malignancy(3cases), bronchiectasis(2cases), chronic renal failure(1cases) or long term history of corticosteroid treatment(3cases). Many patients had multilobar infiltration in chest X-ray, dominantly in the lower lobe. thirty two patients(55.2%) had infiltration in more than 2 lobes and 5 patients in more than 4 lobes. The significant correlation between the diabetes mellitus and the infiltrated Rt lower lobe(RLL) was found on the borders of confidence limit.(P=0.07<0.1). There was significant correlation between woman and infiltrated lobe(RML, RLL, LLL) excluding the both upper lobe(P=0.029). Conclusion : We must consider tuberculous pneumonia when lobar pneumonia with consolidation resistant to antibiotics, especially in the patients who have diabetes mellitus, chronic obstructive pulmonary disease, malignancy, bronchiectsis, chronic renal failure or long term history of corticosteroid treatment.

Identification of Bovine Pregnancy-Specific Whey Proteins using Two-Dimensional Gel Electrophoresis

  • Han, Rong-Xun;Choi, Su-Min;Kim, Myung-Youn;Quan, Yan Shi;Kim, Baek-Chul;Diao, Yun Fei;Koqani, Reza;Park, Chang-Sik;Jin, Dong-Il
    • Reproductive and Developmental Biology
    • /
    • v.32 no.4
    • /
    • pp.255-261
    • /
    • 2008
  • The early diagnosis of bovine pregnancy is an essential component of successful reproductive planning on farms, because lack of bovine pregnancy over the long term results in reproductive failure and low milk yield-the latter of which is a special concern on dairy farms. This study was designed to identify early pregnancy-specific whey proteins in bovine, by comparing milk samples collected from cattle during pregnancy (Days 30 and 50) and from non-pregnant cattle. In this study, differentially expressed proteins in five pregnant and five non-pregnant Holstein dairy cattle were investigated and compared, using proteomics analysis. The first dimension was applied to a pH $3.0{\sim}10.0$ strip, by loading a 2-mg milk protein sample. After the second-dimension separation was performed, the gels were stained with colloidal Coomassie brilliant blue. The stained gels were scanned and the images were analyzed, to detect variations in protein spots between non-pregnant and pregnant cattle milk protein spots, using ImageMaster, this was followed by analysis with MALDI TOF-MS. Analysis of the 2-DE gel image resulted in a total of approximately $500{\sim}600$ protein spots, of which 12 spots were differentially expressed, six spots were up-regulated, and four spots were down-regulated; two spots were identified as pregnancy-specific proteins. These proteins were identified as lactoferrin, NA-DH dehydrogenase subunit 2, albumin, serum albumin precursor and transferrin. Our results via 2-D PAGE analysis revealed composite profiles of several milk proteins related to early bovine pregnancy, implying the possible use of these milk proteins in the early detection of bovine pregnancy.

Stability and Damage Evaluation of the Buddha Triad and 16 Rock-Carved Arhat Statues at Seongbulsa Temple in Cheonan, Korea (천안 성불사 마애석가삼존과 16나한상의 손상도 및 안정성 평가)

  • Yang, Hyeri;Lee, Chan Hee;Jo, Young Hoon
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.4
    • /
    • pp.78-99
    • /
    • 2020
  • The Buddha triad and 16 Arhat statues carved on the rock surface at Seongbulsa temple is the only domestic remaining example of all 16 Arhats, so its academic value is very high. However, it is severely damaged and so required a stability evaluation through study of digital documentation and precise diagnosis for the purpose of comprehensive conservation. This process established that the Buddha statues were of similar scale, while the Arhats showed a wide variety of sizes, and the two kith and kin in the volume were larger than the Arhats. It was estimated that the statues of food for Buddha are similar to the Arhat statues, and most of the statues are well-formed. The rock used to carve the Buddha statues is banded gneiss with distinct foliation, alternating between white bands of quartz and feldspar and black bands composed of biotite. The Buddha statues have been damaged by physical weathering, discoloration, and biological contamination. In damage evaluations, joint (3.6 crack index), peeling (5.2%), exfoliation (1.7%), and falling off (0.1%) were observed on the rock surface of the Buddha statues. In particular, due to severe biological weathering, stage 9 and 10 biological coverage of the rock surface accounted for 57.5% of the total area, and stages 5 to 8 also accounted for a high share at 22.3%. The discoloration factors were shown to be dark brown and white with Fe, Ca, and S, and a large amount of C detected in the blackened contaminants, and the damage weight high in all areas. Discontinuities in different directions were identified in the rock surface. Analysis of potential rock failure types indicated that there is a possibility of plane and toppling failure, but wedge failure is unlikely to occur. The mean ultrasonic velocity of the main rock surface was 2,463m/sec, the lower part of the left side with a large number of joints was relatively low, and the highly weathered (HW) type to the completely weathered (CW) type concentrated distribution, showing weak properties. For the Buddha statues, conservation treatment is required for about 14.9% of micro cracks and 58.9% of exfoliation cracks. In addition, in order to improve the conservation environment of the Buddha statues, maintenance of drainage and ground preparations for the rock surface gradient and plants are necessary, and protection facilities should be reviewed for long-term conservation and management purposes.

The Influences of Maintenance Hemodialysis on Sleep Architecture and Sleep Apnea in the Patients with Chronic Renal Failure (만성신부전 환자에서 혈액투석 유지요법이 수면구조 및 수면 무호흡에 미치는 영향)

  • Park, Yong-Geun;Lee, Sang-Haak;Choi, Young-Mee;Ahn, Seok-Joo;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.824-835
    • /
    • 1999
  • Background: Sleep-related breathing disorders are commonly found in patients with chronic renal failure and particularly, sleep apnea may have an influence on the long-term mortality rates in these patients. Maintenance hemodialysis is the mainstay of medical measures for correcting the metabolic derangements of chronic renal failure but it is uncertain whether it may alleviate sleep disorders including sleep apnea. Methods: Forty seven patients on maintenance hemodialysis were surveyed with the sleep questionnaire about their clinical symptoms related to sleep disorders. Among them, 15 patients underwent the polysomnography and their blood levels of urea nitrogen, creatinine, electrolytes and the arterial blood gases in the nights before and following hemodialysis were measured. Results: Forty(85.1%) of the 47 patients complained of the symptoms associated with sleep-wake cycle disturbances, 55.3% experienced snoring and 27.7% reported witnessed apneas. The duration of REM sleep increased significantly in the nights after hemodialysis compared to the nights without hemodialysis(p<0.05) and the percentage of total sleep time comprising NREM sleep decreased significantly in the nights following hemodialysis compared to the nights before hemodialysis(p<0.05). The percentage of total sleep time consisting of the stage 1 and 2 NREM sleep showed the trend for a decrease in the nights after hemodialysis(p=0.051), while the percentage of total sleep time comprising the stage 3 and 4 NREM sleep did not change between nights. The obstructive sleep apnea was more predominant type than the central one in both nights and there were no differences in the apnea index and the apnea-hypopnea index between the nights. The decrease in the blood level of urea nitrogen, creatinine, potassium and phosphorus was observed after hemodialysis(p<0.05), but the differences of parameters measured during polysomnography between the nights did not correlate with the changes of biochemical factors obtained on the two nights. Arterial blood gas analysis showed that pH was significantly greater in the nights after hemodialysis than in the nights before hemodialysis(p<0.05), but there were no correlations between the parameters examined during polysomnography and the parameters of arterial blood gas analysis(p<0.05). Conclusion: These results suggest that chronic renal failure is an important systemic disorder which is strongly associated with sleep disorders. Maintenance hemodialysis, although it is a widely accepted measure to treat chronic renal failure, did not significantly modulate the sleep architecture and the severity of sleep apnea. Thus, taking the patients with chronic renal failure into account, it is advisable to try not only to find a substantial way for correcting metabolic derangements but also to consider the institution of more effective treatments for sleep disorders.

  • PDF

EFFECT OF ANCHORAGE SYSTEMS ON LOAD TRANSFER WITH MANDIBULAR IMPLANT OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS (하악 임플란트 overdenture에서 anchorage system이 하중전달에 미치는 영향)

  • Kim Jin-Yeol;Jeon Young-Chan;Jeong Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.507-524
    • /
    • 2002
  • Load transfer of implant overdenture varies depending on anchorage systems that are the design of the superstructure and substructure and the choice of attachment. Overload by using improper anchorage system not only will cause fracture of the framework or screw but also may cause failure of osseointegration. Choosing anchorage system in making prosthesis, therefore, can be considered to be one of the most important factors that affect long-term success of implant treatment. In this study, in order to determine the effect of anchorage systems on load transfer in mandibular implant overdenture in which 4 implants were placed in the interforaminal region, patterns of stress distribution in implant supporting bone in case of unilateral vertical loading on mandibular left first molar were compared each other according to various types of anchorage system using three-dimensional photoelastic stress analysis. The five photoelastic overdenture models utilizing Hader bar without cantilever using clips(type 1), cantilevered Hader bar using clips(type 2), cantilevered Hader bar with milled surface using clips(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4), and Hader bar using clip and ERA attachments(type 5), and one cantilevered fixed-detachable prosthesis(type 6) model as control were fabricated. The following conclusions were drawn within the limitations of this study, 1. In all experimental models. the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. Maximum fringe orders on ipsilateral distal implant supporting bone in a ascending order is as follows: type 5, type 1, type 4, type 2 and type 3, and type 6. 3. Regardless of anchorage systems. more or less stresses were generated on the residual ridge under distal extension base of all overdenture models. To summarize the above mentioned results, in case of the patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant and unfavorable antero-posterior spread. selecting resilient type attachment or minimizing distal cantilever bar is considered to be appropriate methods to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.