Evaluation of Insulation Deterioration for the Development of SVM Algorithm to Diagnose OF Cable

OF 케이블 진단용 SVM 알고리즘 개발을 위한 절연열화 평가

  • Kwak, Byeong Sub (KEPCO Research Institute, Korea Electric Power Corporation) ;
  • Jun, Tae-Hyun (KEPCO Research Institute, Korea Electric Power Corporation) ;
  • Kim, Ah-Reum (KEPCO Research Institute, Korea Electric Power Corporation) ;
  • Park, Hyun-joo (KEPCO Research Institute, Korea Electric Power Corporation)
  • Received : 2019.09.25
  • Accepted : 2019.10.23
  • Published : 2019.12.30

Abstract

South Korea's OF cable is reaching its expected design life of 30 years, and as a result, the risk of failure is increasing. Therefore, it is necessary to diagnose the long-term operating OF cables through accurate diagnosis at the right time to prevent the failure. Currently, the KEPCO periodically conducts DGA. However, the gas found in DGA is caused by oil deterioration as well as insulation paper. Therefore, the analysis of the degree of polymerization and furan compounds which is an evaluation of insulation paper considered to be the life of OF cables is required. In addition, the results of the evaluation of deterioration of insulation paper need to be checked for correlation with the results of DGA. In this study, DGA carried out through GC, the degree of polymerization was analyzed using an automatic viscometer, and HPLC was used to detect the furan compounds. In addition, the obtained results were applied to the SVM technique, which was recently introduced to determine abnormalities in OF cable. And the results which were accurate and reliable were obtained.

OF 케이블의 예상 설계 수명인 30년이 도달하면서 고장 위험성이 증가하고 있다. 따라서 정확한 진단을 통한 열화 판정으로 장기 운용 OF 케이블을 적기에 진단함으로써 고장을 예방해야 한다. 또한 최적의 진단기준을 제시하여 잔류 수명을 예측하고 적절한 시기에 교체하는 조치가 요구되고 있다. 현재 한국전력공사에서는 OF 케이블을 진단하기 위해서 주기적으로 케이블 유중 가스분석을 실시하여 C2H2, TCG 등 일부 가스만 활용하고 있다. 하지만 이러한 유중 가스분석에서 확인되는 가스는 절연지뿐만 아니라 오일의 열화에 의해서도 발생된다. OF 케이블은 해체점검이 불가하기 때문에 절연지의 수명이 OF 케이블의 수명으로 간주되고 있다. 따라서 절연지를 직접적으로 분석하는 절연지 중합도 평가와 절연유중 퓨란화합물을 분석이 필요하며, 유중 가스분석에서 확인되는 CO, H2, CH4, C2H4, C2H6, C2H2 가스와 상관관계를 확인할 필요가 있다. 따라서 본 연구에서는 절연유중 가스를 분석하기 위해 headspace sampler가 장착된 GC를 사용하였고, 절연지 중합도는 자동점도계를 활용하였으며, 절연유중 퓨란화합물은 HPLC를 이용하여 측정하였다. 또한 OF 케이블의 종합적인 판정을 위하여 국내 OF 케이블 중 15개소를 선정하여 해체점검을 수행하였다. 또한 이렇게 얻어진 결과는 최근 전력설비 이상판정에 도입되고 있는 SVM 기법에 적용하여 정확하고 신뢰성 있는 열화판정을 도출하고자 하였다. 그 결과 절연지 중합도 잔률은 CO와 CO2 농도의 합에 따라 음의 2차 함수 관계로 감소하는 것으로 확인되었다. 또한 본 연구에서 얻어진 한전 OF 케이블 진단결과를 SVM 기법에 적용함으로써 한전 OF 케이블 진단결과를 기존 일본 동경전력의 SVM에 적용한 진단결과보다 향상되었고, 그 정확도는 약 87.9% 인 것으로 확인되었다.

Keywords

References

  1. Chatterjee, A., Bhattacharjee, P., Roy, N.K., Kumbhakar, P., "Usage of nanotechnology-based gas sensor for health assessment and maintenance of transformers by DGA method," Electrical Power and Energy Systems, 45(2013), pp.137-141, October, 2012.
  2. Fofana, I., Hemmatjou, H., Farzaneh, M., "Low temperature and moisture effects on polarization and depolarization currents of oil-paper insulation," Electric Power Systems Research, 80(2010), pp.91-97, September, 2009.
  3. Jiangjun, R., Shuo, J., Zhiye, D., Yiming, X., Lin, Z., Yu, T., Ruohan, G., Guannan, L., Min, X., "Condition Assessment of Paper Insulation in Oil-Immersed Power Transformers Based on the Iterative Inversion of Resistivity," Energies, 10. pp.509-523, April, 2017. https://doi.org/10.3390/en10040509
  4. Polansky, R., Prosr, P., Vik, R., Moravcova, D., Pihera, J., "Comparison of the mineral oil lifetime estiates obtained by differential scanning calorimetry, infrared spectroscopy, and dielectric dissipation factor measurements," Thermochimica Acta, 647(2017), pp.86-98, December, 2016.
  5. Adekoya, D., Adejumobi, I., "Analysis of acidic properties of distribution transformer oil insulation: a case study of Jericho(Nigeria) distribution network," Nigerian Journal of Technology, 36(2), pp.563-570, April, 2017. https://doi.org/10.4314/njt.v36i2.32
  6. Jong-Chul Lee., Hyeon-Seok S., Youn-Jea K., "The increased dielectric breakdown voltage of transformer oil-based nanofluids by an external magnetic field," International Journal of Thermal Sciences, 62(2012), pp.29-33, April, 2012. https://doi.org/10.1016/j.ijthermalsci.2012.03.013
  7. Darabad, V., Vakilian, M., Blackburn, T., Phung, B., "An efficient PD data mining method for power transformer defect models using SOM technique," Electrical Power and Energy Systems, 71(2015), pp.373-382, March, 2015. https://doi.org/10.1016/j.ijepes.2015.03.016
  8. 전기협동연구 "지중송전케이블의 보전기술" 제70권 1호
  9. Hill, D.J.T., Le, T.T., Darveniza, M., Saha, T., "A study of degradation of cellulosic insulation materials in a power transformer. Part 2: tensile strength of cellulose insulation paper," Polymer Degradation and Stability, 49(1995), pp.429-435, June, 1995. https://doi.org/10.1016/0141-3910(95)00100-Z
  10. Hanung, N.S., Suwarno, Nanang, H., Yoshinobu, M., Tsuguhiro, T., Tatsuki, O., "Degree of Polymerization Estimation of Insulation Papers in Power Transformers Based on Load and Temperature Histories in Java-Bali Region of Indonesia National Electric Company," IEEE, 2012, pp.23-27.
  11. Pahlavapour, B., Eklund, M., Martins, M., "Insulating Paper Ageing and Furfural Formation," IEEE, 2003, pp.283-288.
  12. Katsunori, M., Etsuo, O., Naoki, Y., "Evaluation of Aging for Thermally Upgraded Paper in Mineral Oil," Journal of International Council on Electrical Engineering," 1(2), pp.181-187, March, 2011. https://doi.org/10.5370/JICEE.2011.1.2.181