• Title/Summary/Keyword: logarithmic unit

Search Result 33, Processing Time 0.028 seconds

Protoplast Formation and Regeneration of Bacillus strains producing biopolymer (Biopolymer 생산성 Bacillus속 균주의 원형질체 형성과 재생)

  • Yim, Moo-Hyun;Kim, Seong-Ho
    • Applied Biological Chemistry
    • /
    • v.42 no.1
    • /
    • pp.20-28
    • /
    • 1999
  • To improve Bacillus strains producing biopolymer, conditions for protoplast formation and regeneration were investigated in biopolymer producing Bacillus subtilis K-1 and lactose utilizing Bacillus coagulans. Bacillus subtilis K-1 mutant (SM-2) and Bacillus coagulans mutants (CM-12) were marked auxotrophic and antibiotics-resistant (SM-2) and an antibiotics-resistant mutants, respectively. To formate protoplasts derived from the mutants, conditions were established as follows. For B. subtilis mutant SM-2, its culture in mid-logarithmic phase was added with penicillin G (1.0 unit/ml) and further reacted for 1.5 hr. Cells were collected and then treated in lysis fluid (pH 7.0) containing 0.4 M sucrose and lysozyme $25\;{\mu}g/ml$ for 40 min at $37^{\circ}$. Protoplast formation was very successful (99.6%) and the ratio of cell wall regeneration was 2.4%. For Bacillus coagulans mutant CM-12, its mid-logarithmic phase culture was treated with penicillin G (0.3 unit/ml) and glycine (0.5%) for 1hr. Cells were collected and then resuspended in lysis buffer (pH 7.0) containing 0.6 M lactose and lysozyme $(300\;{\mu}g/ml)$ for 30 min at $37^{\circ}$. Protoplast formation was also successful (90.8%) and cell wall regeneration ratio was similar to SM-2 (2.2%). To improve regeneration frequency, regeneration medium was obtained as followed condition,. Cell wall regeneration was improved 2-4 folds with 5.1% for B. subtilis SM-2 and 10.3% for B. coagulans CM-12 when protoplasts mixed with soft top agar(0.4%) was overlaid onto trypticase soy broth medium containing 0.4 M sucrose, 0.7% casamino acid, 1% PVP, 25 mM $MgCl_2,\;25\;mM\;CaCl_₂$ and 1.5% agar.

  • PDF

Estimation for the Variation of the Concentration of Greenhouse Gases with Modified Shannon Entropy (변형된 샤논 엔트로피식을 이용한 온실가스 농도변화량 예측)

  • Kim, Sang-Mok;Lee, Do-Haeng;Choi, Eol;Koh, Mi-Sol;Yang, Jae-Kyu
    • Journal of Environmental Science International
    • /
    • v.22 no.11
    • /
    • pp.1473-1479
    • /
    • 2013
  • Entropy is a measure of disorder or uncertainty. This terminology is qualitatively used in the understanding of its correlation to pollution in the environmental area. In this research, three different entropies were defined and characterized in order to quantify the qualitative entropy previously used in the environmental science. We are dealing with newly defined distinct entropies $E_1$, $E_2$, and $E_3$ originated from Shannon entropy in the information theory, reflecting concentration of three major green house gases $CO_2$, $N_2O$ and $CH_4$ represented as the probability variables. First, $E_1$ is to evaluate the total amount of entropy from concentration difference of each green house gas with respect to three periods, due to industrial revolution, post-industrial revolution, and information revolution, respectively. Next, $E_2$ is to evaluate the entropy reflecting the increasing of the logarithm base along with the accumulated time unit. Lastly, $E_3$ is to evaluate the entropy with a fixed logarithm base by 2 depending on the time. Analytical results are as follows. $E_1$ shows the degree of prediction reliability with respect to variation of green house gases. As $E_1$ increased, the concentration variation becomes stabilized, so that it follows from linear correlation. $E_2$ is a valid indicator for the mutual comparison of those green house gases. Although $E_3$ locally varies within specific periods, it eventually follows a logarithmic curve like a similar pattern observed in thermodynamic entropy.

PERFORMANCE TEST FOR A PDS MICRODENSITOMETER MODEL 1010GMS

  • Hong, S.S.;Paek, W.G.;Lee, S.G.
    • Journal of The Korean Astronomical Society
    • /
    • v.25 no.1
    • /
    • pp.23-46
    • /
    • 1992
  • The electrical, mechanical and optical capabilities have been tested of the microdensitometer PDS 1010GMS at the Korea Astronomy Observatory. The highest stage of scan speed 255 csu (conventional speed unit) is measured to be 47 mm/s. At this speed the position is displaced by $4{\mu}m$ to the direction of scanning and the density is underestimated by $0.4{\sim}0.7D$. Standard deviation in the measured density is proportional to $A^{-0.46}$, where A is the area of scan aperture. The accuracy of position repeatability is ${\pm}1{\mu}m$, and that of density repeatability is ${\pm}(0.003{\sim}0.03)D$. Callier coefficient is determined to be 1.37; the semispecular density is directly proportional to the diffuse density up to 3.5D. Because the logarithmic amplifier has a finite response time, the densities measured at high scan speeds are underestimated to the degree that speeds higher than 200 csu are inadequate for making an accurate astronomical photometry. After power is on, an about 5 hour period of warming is required to stabilize the system electrically and mechanically as well. On the basis of this performance test, we have determined the followings as the optimum scan parameters for the astronomical photometry: For the scan aperture $10\;\sim\;20{\mu}m$ is optimal, and for the scan speed. $20\;{\sim}\;50$ csu is appropriate. These parameter values are chosen in such a way that they may keep the density repeatability within ${\pm}0.01D$, the position displacement under $1{\mu}m$, and the density underestimation below 0.1D even in high density regions.

  • PDF

Charaterization of Nisin Production and Resistance of Lactococcus lactis ssp. lactis $ML_8$ (Lactococcus lactis ssp. lactis $ML_8$의 Nisin 생산 및 저항 특성)

  • 김등양;이형주
    • Microbiology and Biotechnology Letters
    • /
    • v.19 no.6
    • /
    • pp.619-623
    • /
    • 1991
  • To investigate nisin production and resistance of Lactococcus lactis ssp. tactis ML (L. lactis $ML_8$, effects of medium, pH of culture broth, and cell growth on the nisin activity, and effect of nisin with or without $Ca^[2+}$ ion on the growth of L. lactzs were analyzed. In the bio-assay of nisin by the agar diffusion method, inhibition-zone diameter of Micrococcus Javus was propotional to the logarithm of nisin concentration ranged 0.5~20 unitlml (12.5~500 ng/mf). Nisin activity of the pasteurized culture filtrates of L. lactis MLs was high at pH 2!3 but was inactivated completely at pH over 6.0. Nisin production of the L. lactis $ML_8$ cultured on LTB broth increased at late logarithmic phase and reached 10.5 unitlml after 16 hr. The cell growth of L. lactis LM 0230, a plasmid free and nisin sensitive strain, was inhibited on agar medium containing 7 unitlrnl of nisin, while L. lactis $ML_8$ showed high survival ability at 20 unitld of nisin. When 40 mM $Ca^[2+}$ ion was added to Elliker broth with 8 unitlml of nisin, the growth pattern of L. lactis $ML_8$ was similiar to that on control medium which did not contain nisin and $Ca^[2+}$ ion, and this suggested that $Ca^[2+}$ increased the nisin resistance of the L. lactis.

  • PDF

Hardware Design of Arccosine Function for Mobile Vector Graphics Processor (모바일 벡터 그래픽 프로세서용 역코사인 함수의 하드웨어 설계)

  • Choi, Byeong-Yoon;Lee, Jong-Hyoung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.727-736
    • /
    • 2009
  • In this paper, the $arccos(cos^{-1})$ arithmetic unit for mobile graphics accelerator is designed. The mobile vector graphics applications need tight area, execution time, power dissipation, and accuracy constraints compared to desktop PC applications. The designed processor adopts 2nd-order polynomial approximation scheme based on IEEE floating point data format to satisfy speed and accuracy conditions and reduces area via hardware sharing structure. The arccosine processor consists of 15,280 gates and its estimated operating frequency is about 125Mhz at operating condition of $0.35{\mu}m$ CMOS technology. Because the processor can execute arccosine function within 7 clock cycles, it has about 17 MOPS(million arccos operations per second) execution rate and can be applicable to mobile OpenVG processor. And because of its flexible architecture, it can be applicable to the various transcendental functions such as exponential, trigonometric and logarithmic functions via replacement of ROM and minor hardware modification.

Study on the Development of a Model for Teaching and Learning Mathematics Using Graphic Calculators (그래픽 계산기를 활용하는 수학과 교수-학습 자료 모형 개발 연구)

  • 강옥기
    • Journal of Educational Research in Mathematics
    • /
    • v.8 no.2
    • /
    • pp.453-474
    • /
    • 1998
  • This study is focused on the possibility if we can use graphic calculators in teaching and learning school mathematics. This study is consisted with four main chapters. In chapter II, the functions of the graphic calculator EL-9600 produced by Sharp Corporation was analyzed focused on the possibilities if the functions could be used in teaching and learning school mathematics. Calculating of real numbers and complex numbers, solving equations and system of linear equations, calculating of matrices, graphing of several functions including polynomial functions, trigonometric functions, exponential and logarithmic functions, calculation of differential and integrals, arranging of statical data, graphing of statistical data, testing of statistical hypotheses, and other more useful functions were founded. In Chapter III, a mathematics textbook developed by Core-Plus Mathematics Project was analyzed focused on how a graphic calculator was used in teaching and learning mathematics, In the textbook, graphic calculator was used as a tool in understanding mathematical concepts and solving problems. Graphic calculator is not just a tool to do complex computations but a tool used in the processes of doing mathematics, In chapter IV, the 7th mathematics curriculum for korean secondary schools was analyzed to find the contents could be taught by using graphic calculators. Most of the domains, except geometric figure, were found that they could be taught by using graphic calculators, In chapter V, a model of a unit using graphic calculator in teaching 7th mathematics curriculum was developed. In this model, graphic calculator was used as a tool in the processes of understanding mathematical concepts and solving problems. This study suggests the possibilities that we can use graphic calculators effectively in teaching and learning mathematical concepts and problem solving for most domains of secondary school mathematics.

  • PDF

Carrying Capacity Behavior of Instrumented PC Piles (시험 콘크리트 말뚝의 지지력 거동)

  • 이영남;이종섭
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.163-172
    • /
    • 1998
  • To study the carrying capacity behavior of pile, dynamic pile testis and static load tests were carried out on two instrumented piles during and some time after pile driving. Cone Penetration Test( CPT) and Standard Penetration Test(SPT) were also performed at the test site before pile tests to investigate the relationship between unit skin friction of piles and cone tip resistance values and SPT N values. Total static capacity of pile reached the ultimate stage at the pile head settlement of about 0.055D (D : Pile diameter), at which skin friction of Pile already Passed the maximum value, but the end bearing was still increasing with the pile head settlement. The carrying capacity of pile increased in the form of natural logarithmic function with the time after pile driving. The increase in skin friction with time was very substantial the increase in skin friction 40 days after pile driving was 4.6 times of that determined during pile driving. The contribution of skin friction to the total capacity twas insignificant in the beginning, but became substantial 40 days after pile driving. This implies that the tested pile initially responded as an end bearing pile and later behaved as a friction pile. It was also noted that unit skin friction of pile might be ielated to cone tip resistance values(q.) and SPT N values, though the coefficient of this relationship might differ from one soil group to another and was somewhat greater than the value used in the design practice of Korea.

  • PDF

Marginal Bone Resorption Analysis of Dental Implant Patients by Applying Pattern Recognition Algorithm (패턴인식 알고리즘을 적용한 임플란트 주변골 흡수 분석)

  • Jung, Min Gi;Kim, Soung Min;Kim, Myung Joo;Lee, Jong Ho;Myoung, Hoon;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.3
    • /
    • pp.167-173
    • /
    • 2013
  • Purpose: The aim of this study is to analyze the series of panoramic radiograph of implant patients using the system to measure peri-implant crestal bone loss according to the elapsed time from fixture installation time to more than three years. Methods: Choose 10 patients having 45 implant fixtures installed, which have series of panoramic radiograph in the period to be analyzed by the system. Then, calculated the crestal bone depth and statistics and selected the implant in concerned by clicking the implant of image shown on the monitor by the implemented pattern recognition system. Then, the system recognized the x, y coordination of the implant and peri-implant alveolar crest, and calculated the distance between the approximated line of implant fixture and alveolar crest. By applying pattern recognition to periodic panoramic radiographs, we attained the results and made a comparison with the results of preceded articles concerning peri-implant marginal bone loss. Analyzing peri-implant crestal bone loss in a regression analysis periodic filmed panoramic radiograph, logarithmic approximation had highest $R^2$ value, and the equation is as shown below. $y=0.245Logx{\pm}0.42$, $R^2=0.53$, unit: month (x), mm (y) Results: Panoramic radiograph is a more wide-scoped view compared with the periapical radiograph in the same resolution. Therefore, there was not enough information in the radiograph in local area. Anterior portion of many radiographs was out of the focal trough and blurred precluding the accurate recognition by the system, and many implants were overlapped with the adjacent structures, in which the alveolar crest was impossible to find. Conclusion: Considering the earlier objective and error, we expect better results from an analysis of periapical radiograph than panoramic radiograph. Implementing additional function, we expect high extensibility of pattern recognition system as a diagnostic tool to evaluate implant-bone integration, calculate length from fixture to inferior alveolar nerve, and from fixture to base of the maxillary sinus.

Production and Characterization of Thermostable Protease from Bacillus licheniformis Isolated from Korean Traditional Soybean Paste (재래식 된장에서 분리된 Bacillus licheniformis의 내열성 Protease 특성과 생산성)

  • Bae, Young Eun;Yoon, Ki-Hong
    • Korean Journal of Microbiology
    • /
    • v.48 no.4
    • /
    • pp.298-304
    • /
    • 2012
  • Among 63 Bacillus strains grown at $60^{\circ}C$ from sixteen samples of homemade Korean soybean paste, one strain was selected for producing the thermostable protease. The isolate has been identified as Bacillus licheniformis on the basis of its 16S rDNA sequence, morphology and biochemical properties. Culture filtrate of the isolate showed maximal protease activity at the reaction condition of $60-65^{\circ}C$ and pH 11. The culture filtrate retained more than 87% of initial protease activity after incubation for 30 min at $60^{\circ}C$ without substrate. In order to develop the medium composition, effects of ingredients including nitrogen sources, carbon sources, metal ions and phosphate were examined for protease production of the isolate. Lactose and soytone peptone were the most effective carbon and nitrogen source for the enzyme production. After the late logarithmic growth phase the isolate began to produce the protease, and the maximum protease productivity was reached to 550 unit/ml in the optimized medium consisting of lactose (3%), soytone peptone (1.5%), $MgSO_4$ (0.1%), $K_2HPO_4$ (0.03%), and $KH_2PO_4$ (0.03%) at 28 h of incubation.

Dielectric Properties of Semi-IPN Poly(phenylene oxide) Blend/$BaTiO_3$ Composites with Type of Cross-linker (가교체 종류에 따른 Semi-IPN Poly(phenylene oxide) 블렌드와 $BaTiO_3$ 복합재료의 유전특성)

  • Jang, Yong-Kyun;Lee, Ho-Il;Seong, Won-Mo;Park, Sang-Hoon;Yoon, Ho-Gyu
    • Polymer(Korea)
    • /
    • v.33 no.3
    • /
    • pp.224-229
    • /
    • 2009
  • The dielectric properties of semi-IPN poly(phenylene oxide)(PPO) blend/$BaTiO_3$(BT) composites are investigated. The composites are fabricated via melt-mixing of crosslinker and peroxide in precursor PPO composite obtained by precipitating the suspension consisted of PPO, BT and toluene into methylethyl ketone, poor solvent of PPO. The permittivity of the precursor PPO composites shows higher value than that of integral-blended PPO composites by extruder and coincides with the theoretical value calculated by logarithmic rule of mixture. The blend of PPO and cross-linked triallyl isocyanurate is most effective for lowering the permittivity and loss tangent owing to the suppression of the orientation polarization of matrix. In contrast, 4,4'-(1,3-phenylene diisopropylidene) bisaniline, which has amine unit in its structure, increases the permittivity as well as loss tangent of the composite, but it has the ability to densify the matrix resin and the interfacial adhesion between the matrix and filler to improves flexural strength and modulus.