• Title/Summary/Keyword: local zone

Search Result 722, Processing Time 0.024 seconds

A Study on the Flexible Disk Deburring Process Arc Zone Parameter Prediction Using Neural Network (신경망을 이용한 유연디스크 디버링가공 아크형상구간 인자예측에 관한 연구)

  • Yoo, Song-Min
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.681-689
    • /
    • 2009
  • Disk grinding was often applied to deburring process in order to enhance the final product quality. Inherent chamfering capability of the flexible disk grinding process in the early stage was analyzed with respect to various process parameters including workpiece length, wheel speed, depth of cut and feed. Initial chamfered edge defined as arc zone was characterized with local radius of curvature. Averaged radius and arc zone ratio was well evaluated using neural network system. Additional neural network analysis adding workpiece length showed enhance performance in predicting arc zone ratio and curvature radius with reduced error rate. A process condition design parameter was estimated using remaining input and output parameters with the prediction error rate lower than 2.0% depending on the relevant input parameter combination and neural network structure composition.

  • PDF

Clinical presentation and specific stabilizing exercise management in Lumbar segmental instability (요추분절의 불안정성에 대한 임상적 소개와 안정성 운동관리)

  • Jung Yeon-Woo;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.155-170
    • /
    • 2003
  • Lumbar segmental instability is considered to represent a significant sub-group within the chronic low back pain population. This condition has a unique clinical presentation that displays its symptoms and movement dysfunction within the neutral zone of the motion segment. The loosening of the motion segment secondary to injury and associated dysfunction of the local muscle system renders it biomechanically vulnerable in the neutral zone. There in evidence of muscle dysfunction related to the control of the movement system. There is a clear link between reduced proprioceptive input, altered slow motor unit recruitment and the development of chronic pain states. Dysfunction in the global and local muscle systems in presented to support the development of a system of classification of muscle function and development of dysfunction related to musculoskeletal pain. The global muscles control range of movement and alignment, and evidence of dysfunction is presented in terms of imbalance in recruitment and length between the global stability muscles and the global mobility muscles. The local stability muscles demonstrate evidence of failure of aeequate segmental control in terms of allowing excessive uncontrolled translation or specific loss of cross-sectional area at the site of pathology Motor recruitment deficits present as altered timing and patterns of recruitment. The evidence of local and global dysfunction allows the development of an integrated model of movement dysfunction. The clinical diagnosis of this chronic low back pain condition is based on the report of pain and the observation of movement dysfunction within the neutral zone and the associated finding of excessive intervertebral motion at the symptomatic level. Four different clinical patterns are described based on the directional nature of the injury and the manifestation of the patient's symptoms and motor dysfunction. A specific stabilizing exercise intervention based on a motor learning model in proposed and evidence for the efficacy of the approach provided.

  • PDF

A Study on the Process of Variety about the Local Houses in the Samchok and Suckpo Dirstrict (삼척·석포지방 민가의 변화에 관한 연구(硏究))

  • Rim, Sangkyu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.2 no.2
    • /
    • pp.11-22
    • /
    • 2000
  • The structure and space construction of local houses and its form of shape were under the influence of the character of locality and times. Each area makes an distinctive culture by spreading the developed culture to an undeveloped area. Frequent interchange were formed between Samcheok and Bonghwa district for a long time ago. But the change of life zone by progressive traffic makes it to a strange area. Accordingly this study clarify the changed shape and form of local houses by selecting and put it on record an scattered along the road of old times.

  • PDF

Reaction Zone Thickness of Turbulent Premixed Flame

  • Yamamoto, Kazuhiro;Nishizawa, Yasuki;Onuma, Yoshiaki
    • Journal of the Korean Society of Combustion
    • /
    • v.6 no.2
    • /
    • pp.36-42
    • /
    • 2001
  • Usually, we use the flame thickness and turbulence scale to classify the flame structure on a phase diagram of turbulent combustion. The flame structure in turbulence is still in debate, and many studies have been done. Since the flame motion is rapid and its reaction zone thickness is very thin, it is difficult to estimate the flame thickness. Here, we propose a new approach to determine the reaction zone thickness based on ion current signals obtained by an electrostatic probe, which has enough time and space resolution to detect flame fluctuation. Since the signal depends on the flow condition and flame curvature, it may be difficult to analyze directly these signals and examine the flame characteristics. However, ion concentration is high only in the region where hydrocarbon-oxygen reactions occur, and we can specify the reaction zone. Based on the reaction zone existing, we estimate the reaction zone thickness. We obtain the thickness of flames both in the cyclone-jet combustor and on a Bunsen burner, compared with theoretically predicted value, the Zeldovich thickness. Results show that the experimentally obtained thickness is almost the same as the Zeldovich thickness. It is concluded that this approach can be used to obtain the local flame structure for modeling turbulent combustion.

  • PDF

Design and Planning Criteria for the Green Buffer Zone (환경친화적 완충녹지의 기준설정)

  • 박은영;유병림
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.2
    • /
    • pp.25-35
    • /
    • 2004
  • The purpose of the study is to analyze the existing situation of the green buffer zone in the large scale industrial site and other major residential apartment areas. In this study, it is specifically intended that the planning guideline be upgraded to adopt future landuse trends and thus to suggest design criteria for management of the buffer zone. The framework of the analysis is to review the current landuse, noise reduction, ecological implications and landscape in general. Although the major function of a green buffer zone is considered to protect the residential area from various hazards of industrial, traffic, and visual environment, the situation is that most of the zones are maintained at a minimum level of services by local government. The study carried out intensively almost every type of case studied throughout the country, which implies that the management of the green buffer zone should be expanded physically enough to function for its original objectives. The study recommends that ecological management of the green buffer zone be emphasized and therefore the criteria for this purpose as well as noise issue should be developed prior to the landuse aspects. The study suggests specific guidelines for planning and design for the green buffer zone development. This study should be verified positively through the sustainable monitoring and requires nationwide and overall examination so that it may be applied to whole green spaces.

Development of guideline to use dispersants (유처리제 사용해역 선정기준개발)

  • Lee Moon-Jin;Sung Hong-Gun;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 2006
  • A guideline for decision of dispersants use zone was developed at the twelve local sea areas covering the whole Korean sea. In this study, the water depths and damage to sensitive resources were considered as the conditions of the decision of whether or not to use dispersants. According to the conditions of the decision, three kinds of zones were specified as following; 1) dispersants usable zone, 2) dispersants use approvable zone, 3) dispersants use restrictive zone. As the result, dispersants use zone at the twelve local sea areas covering the whole Korean sea are suggested.

  • PDF

가변 풍량 유닛에 의한 실내 공간의 온도제어를 위한 공간의 분할 모델과 상태궤환 제어기의 개발에 관한 연구

  • 박세화;신승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.947-959
    • /
    • 2001
  • We propose a control scheme to control the indoor zone temperature via variable air volume (VAV) unit. To control the room temperature, state space model of the conditioned zone which is partitioned into nine artificial sectional regions is derived. The nonlinearity of the damper motion and actuator are considered for the practical use in the state space system description. The temperature control of the room temperature is performed by manipulating the degree of openness of the damper in relation to the local room temperature and the supplied air flow rate. In general, since a local temperature in the conditioned zone is measured, it is required to estimate the temperature values in each regions for the precise temperature control. We thus design a state observer to estimate the regional temperature, and use these values in the controller. The overall control system consists of the state observer based state feedback with the integral control. We compared the control results of the proposed scheme with those of cascade proportional and integral (PI) control, and showed that the scheme achieved precise control of the conditioned system.

  • PDF

An analytical and computational study on energy dissipation along fracture process zone in concrete

  • Zhao, Yanhua;Xu, Shilang;Li, Zongjin
    • Computers and Concrete
    • /
    • v.1 no.1
    • /
    • pp.47-60
    • /
    • 2004
  • The influence of the fracture process zone (FPZ) on the fracture properties is one of the hottest topics in the field of fracture mechanics for cementitious materials. Within the FPZ in front of a traction free crack, cohesive forces are distributed in accordance with the softening stress-separation constitutive relation of the material. Therefore, further crack propagation necessitates energy dissipation, which is the work done by the cohesive forces. In this paper $g_f$, the local fracture energy characterizing the energy consumption due to the cohesive forces, is discussed. The computational expression of $g_f$ in the FPZ can be obtained for any stage during the material fracture process regarding the variation of FPZ, whether in terms of its length or width. $G_{fa}$, the average energy consumption along the crack extension region, has also been computed and discussed in this paper. The experimental results obtained from the wedge splitting tests on specimens with different initial notch ratios are employed to investigate the property of the local fracture energy $g_f$ and the average value $G_{fa}$ over the crack extension length. These results can be used to indicate the influence of the FPZ. Additionally, changes in the length of the FPZ during the fracture process are also studied.

A Mechanical Model of the End Anchorage Zone of Prestressed Concrete Members

  • Kang, Won-Ho;You, Young-Min;Oh, Seung-Hyun;Lee, Sang-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.1E
    • /
    • pp.35-41
    • /
    • 2006
  • It is expected that recent development of mechanical models will soon supersede previous empirical methods of detailing. In this study, a mechanical model is proposed to analyze the behavior of the anchorage zone of prestressed concrete members. The main characteristics of the proposed model lies in its rational consideration of material properties such as concrete strength in biaxial stress state and that of local zone reinforced by spirals. The shear friction strength of concrete surrounding a spiral is also considered. The computational results of the proposed model as well as the existing Strut-and-Tie model(STM) and nonlinear finite element analysis are compared with experimental results. The results of the comparison revealed that the proposed model showed better prediction of the failure mode as well as the failure load. Additionally, the proposed model also explained the three-dimensional failure mechanism very well, while other methods based on two-dimensional analysis could not do so well.

Stress-strain Model of Laterally Confined High-strength Concrete with the Compressive Fracture Energy (압축파괴에너지를 도입한 횡구속 고강도 콘크리트의 응력-변형률 모델)

  • Hong, Ki-Nam;Shim, Won-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.54-62
    • /
    • 2019
  • In this paper, a stress-strain model for high-strength confined concrete is proposed using compressive fracture energy. In the compression test performed by author in Reference [6], an acrylic bar with strain gauges was embedded in the center of the specimen to measure the local strain distribution. It was found from the test that the local strain measurement by this acrylic rod is very effective. The local fracture zone length was defined based on the local strain distribution measured by the acrylic rod. Specifically, it was defined as the length where the local strain increases more than twice of the strain corresponding to maximum stress. In addition, the stress-strain relationship of confined concrete with compressive fracture energy is proposed on the assumption that the amount of energy absorbed by the compressive members subjected to the given lateral confining pressure is constant regardless of the aspect ratio and size. The proposed model predicts even results from other researchers accurately.