• Title/Summary/Keyword: local loop

Search Result 261, Processing Time 0.026 seconds

Asymmetric Thermal-Mixing Analysis due to Partial Loop Stagnation during Design Basis Accident (원전 설계기준 사고시 냉각재계통 부분정체로 인한 비대칭 열유동 혼합해석)

  • Hwang K. M.;Jin T E.;Kim K. H.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.51-54
    • /
    • 2002
  • When a cold HPSI (High Pressure Safety Injection) fluid associated with an design basis accident, such as LOCA (Loss of Coolant Accident), enters the cold legs of a stagnated primary coolant loop, thermal stratification phenomena will arise due to incomplete mixing. If the stratified flow enters a reactor pressure vessel downcomer, severe thermal stresses are created in a radiation embrittled vessel wall by local overcooling. Previous thermal-mixing analyses have assumed that the thermal stratification phenomena generated in stagnated loop of a partially stagnated coolant loop are neutralized in the vessel downcomer by strong flow from unstagnated loop. On the basis of these reasons, this paper presents the thermal-mixing analysis results in order to identify the fact that the cold plume generated in the vessel downcomer due to the thermal stratification phenomena of the stagnated loop is affected by the strong flow of the unstagnated loop.

  • PDF

Low Phase Noise Design and Implementation of X -Band Frequency Synthesizer for Radar Receiver (레이다 수신기용 X-밴드 주파수 합성기의 저 위상잡음설계 및 구현)

  • So, Won-Wook;Kang, Yeon-Duk;Lee, Taek-Kyung
    • Journal of Advanced Navigation Technology
    • /
    • v.2 no.1
    • /
    • pp.22-33
    • /
    • 1998
  • In the coherent-on-receiver radar system using the magnetron source, frequency synthesizer is employed as a STALO(Stable Local Oscillator) to keep the intermediate frequency stable. In this paper, X-band(8.4GHz~9.7GHz) single loop frequency synthesizer is designed and implemented by an indirect frequency synthesis technique. Phase comparison is performed by a digital PLL(Phase-Locked Loop) chip and the loop filter is designed for the low phase noise. The effects of loop component characteristics on the output phase noise are analyzed for single loop structures, and the calculated results are compared with the measured data.

  • PDF

Stochastic Optimization Approach for Parallel Expansion of the Existing Water Distribution Systems (추계학적 최적화방법에 의한 기존관수로시스템의 병열관로 확장)

  • Ahn, Tae-Jin;Choi, Gye-Woon;Park, Jung-Eung
    • Water for future
    • /
    • v.28 no.2
    • /
    • pp.169-180
    • /
    • 1995
  • The cost of a looped pipe network is affected by a set of loop flows. The mathematical model for optimizing the looped pipe network is expressed in the optimal set of loop flows to apply to a stochastic optimization method. Because the feasible region of the looped pipe network problem is nonconvex with multiple local optima, the Modified Stochastic Probing Method is suggested to efficiently search the feasible region. The method consists of two phase: i) a global search phase(the stochastic probing method) and ii) a local search phase(the nearest neighbor method). While the global search sequentially improves a local minimum, the local search escapes out of a local minimum trapped in the global search phase and also refines a final solution. In order to test the method, a standard test problem from the literature is considered for the optimal design of the paralled expansion of an existing network. The optimal solutions thus found have significantly smaller costs than the ones reported previously by other researchers.

  • PDF

A Relation between High Level Radioactive Waste Repository Site and Policy Acceptance of Local Residents (인과지도를 통한 고준위방사성폐기물처분장과 지역주민의 수용성의 관계 고찰)

  • Oh, Young-Min;Jing, Gyeong-Ho
    • Korean System Dynamics Review
    • /
    • v.10 no.2
    • /
    • pp.29-52
    • /
    • 2009
  • This paper reveals the conceptual relation between High Level Radioactive Waste Repository Site(HLRWR) and Policy Acceptance of Local Residents thorough the Causal Loop Diagram. The Resident's policy acceptance depends on the perceived risk of that facility. To reduce the risks, government has to prepare the schemes of the total supporting program including cash and the local development programs.

  • PDF

A Communication and Computation Overlapping Model through Loop Sub-partitioning and Dynamic Scheduling in Data Parallel Programs (데이타 병렬 프로그램에서 루프 세부 분할 및 동적 스케쥴링을 통한 통신과 계산의 중첩 모델)

  • Kim, Jung-Hwan;Han, Sang-Yong;Cho, Seung-Ho;Kim, Heung-Hwan
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.1
    • /
    • pp.23-33
    • /
    • 2000
  • We propose a model which overlaps communication with computation for efficient communication in the data-parallel programming paradigm. The overlapping model divides a given loop partition into several sub-partitions to obtain computation which can be overlapped with communication. A loop partition sometimes refers to other data partitions, but not all iterations in the loop partition require non-local data. So, a loop partition may be divided into a set of loop iterations which require non-local data, and a set of loop iterations which do not. Each loop sub-partition is dynamically scheduled depending on associated message arrival, The experimental results for a few benchmarks in IBM SP2 show enhanced performance in our overlapping model.

  • PDF

Complexity Reduction of an Adaptive Loop Filter Based on Local Homogeneity

  • Li, Xiang;Ahn, Yongjo;Sim, Donggyu
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.2
    • /
    • pp.93-101
    • /
    • 2017
  • This paper proposes an algorithm for adaptive loop filter (ALF) complexity reduction in the decoding process. In the original ALF algorithm, filtering for I frames is performed in the frame unit, and thus, all of the pixels in a frame are filtered if the current frame is an I frame. The proposed algorithm is designed on top of the local gradient calculation. On both the encoder side and the decoder side, homogeneous areas are checked and skipped in the filtering process, and the filter coefficient calculation is only performed in the inhomogeneous areas. The proposed algorithm is implemented in Joint Exploration Model (JEM) version 3.0 future video coding reference software. The proposed algorithm is applied for frame-level filtering and intra configuration. Compared with the JEM 3.0 anchor, the proposed algorithm has 0.31%, 0.76% and 0.73% bit rate loss for luma (Y) and chroma (U and V), respectively, with about an 8% decrease in decoding time.

mtDNA Diversity and Origin of Chinese Mongolian Horses

  • Li, Jinlian;Shi, Youfei;Fan, Caiyun;Manglai, Dugarjaviin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.12
    • /
    • pp.1696-1702
    • /
    • 2008
  • In order to learn the origin of the Chinese Mongolian horse, we analyzed polymorphisms within the mtDNA D-loop variable region in 305 horses of 6 types of 3 different breeds, including one imported breed, one cultivated breed and 4 types of one local breed. We detected 13 different haplotypes, and subsequent sequence analysis showed that all 6 horse types were genetically diverse. By constructing a cladogram of mtDNA D-loop sequences from the 6 horse types along with homologous sequences from several other horse types obtained from GenBank, we showed that Chinese Mongolian horses have a close genetic relationship with other horse types from Mongolia. We also speculate that several Chinese Mongolian horses descended from Przewalskii horse. Additionally, the 13 haplotypes were dispersed throughout the cladogram, suggesting that Chinese Mongolian horses likely originated from multiple female ancestors. A phylogenetic map of the 6 horse types showed that the genetic relationship between the local Wuzhumuqin and Wushen types were the closest. The Xinihe and Baerhu were also closely related to each other, and slightly more distantly related to the cultivated Sanhe breed. All five of the local Chinese horse types had a much more distant relationship with the imported Thoroughbred breed.

신규 가입자망 기술의 경제성 평가를 위한 망 구조모형과 그 응용

  • 류태규;이정동;김태유
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2000.11a
    • /
    • pp.45-67
    • /
    • 2000
  • Broadband access technologies plays an important role in the national information infrastructure. In the evolution path of the information infrastructure, the relative economics of alternative access technology is the most critical determining factor. In this paper, we discuss the economics of local loop access technologies of existing technologies, such as, ADSL, HFC, and new PLC. To do this, we suggest appropriate configuration of access network system and its associated numerical equations. To modelize access network system and drive the numerical equations, we consider the DS (Double Star) and the T&B (Tree & Brench) architecture and analyse the adequate block diagram of each access system for each technology We introduce the density of subscriber as a key variable and the equation of allocating optimal number of cell in a service area. We analyze the relative economics of local loop architecture in two different situations, that is, urban and rural. From the empirical implementation, we found that for the case of urban area, where the cost of cable and infrastructure is not necessary, there is not much difference in the cost per one subscriber. However, for the case of rural region, we found that there is remarkable difference in the cost per one subscriber among technologies. Therefore we conclude that the economics of local loop architecture is depend on the density of subscriber and existing network infrastructures. we hope that this paper contribute to the optimal technology selection of consmer, technology Providers, and government.

  • PDF

Thermal-Mixing Analyses for Safety Injection at Partial Loop Stagnation of a Nuclear Power Plant

  • Hwang, Kyung-Mo;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1380-1387
    • /
    • 2003
  • When a cold HPSI (High pressure Safety Injection) fluid associated with an overcooling transient, such as SGTR (Steam Generator Tube Rupture), MSLB (Main Steam Line Break) etc., enters the cold legs of a stagnated primary coolant loop, thermal stratification phenomena will arise due to incomplete mixing. If the stratified flow enters the downcomer of the reactor pressure vessel, severe thermal stresses are created in a radiation embrittled vessel wall by local overcooling. As general thermal-hydraulic system analysis codes cannot properly predict the thermal stratification phenomena, RG 1.154 requires that a detailed thermal-mixing analysis of PTS (pressurized Thermal Shock) evaluation be performed. Also. previous PTS studies have assumed that the thermal stratification phenomena generated in the stagnated loop side of a partially stagnated primary coolant loop are neutralized in the vessel downcomer by the strong flow from the unstagnated loop. On the basis of these reasons, this paper focuses on the development of a 3-dimensional thermal-mixing analysis model using PHOENICS code which can be applied to both partial and total loop stagnated cases. In addition, this paper verifies the fact that, for partial loop stagnated cases, the cold plume generated in the vessel downcomer due to the thermal stratification phenomena of the stagnated loop is almost neutralized by the strong flow of the unstagnated loop but is not fully eliminated.

A Comparison Between Round Loop and Existing Octagonal Loop Detectors (원형검지기와 기존검지기의 비교 분석에 관한 연구)

  • 장덕명;김영남
    • Journal of Korean Society of Transportation
    • /
    • v.12 no.4
    • /
    • pp.35-52
    • /
    • 1994
  • In order to operate the computerized traffic signal system, it requires the detectors which ensure the exact detections of actual traffic data (e.g., traffic volume, occupancy and velocity of vehicles). The octagonal detectors are used currently in Korea. However, the maintenance of the detectors has many problems with the road repairs and the constructions on the pavement, and failure due to the disconnection of the wires. Serious delay due to the long installation time of loops also causes the traffic disturbances. The low sensitivities and splash-over effect can sometimes create error data after installation of the octagonal loops. The mai purpose of this study is to evaluate the feasibility of domestic use of the round (circular) inductive loops which developed recently in U.S.A. It was found that the round loops are comparable to the existing octagonal loops. In addition, the use of the high quality of materials in the round loop system can reduce the current problems and weakpoints of the octagonal loops. The installation cost of the round loop was found out as economic as the octagonal loop. The installation time of the round loop system can be reduced with the specially equipped loop truck, and wide/deep slots without sharp corners can extend the durability without serious stress of loop head wires. In conclusion, the round loop is superior to the octagonal type in overall points. It is recommended that the localization of the materials and equipments of round loop system is required to carry out the extensive local installations. Also, several contractors to meet the nationwide demand should be arranged to gurantee the proper maintenance and operation of the systems.

  • PDF