• Title/Summary/Keyword: local loop

Search Result 261, Processing Time 0.031 seconds

Ranging Performance Evaluation of Relative Frequency Offset Compensation in High Rate UWB (고속 UWB의 상대주파수 차이 보상에 의한 거리추정 성능평가)

  • Nam, Yoon-Suk;Lim, Jae-Geol;Jang, Ik-Hyeon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.7
    • /
    • pp.76-85
    • /
    • 2009
  • UWB signal with high resolution capability can be used to estimate ranging and positioning in wireless personal area network. The node works on its local clock and the frequency differences of nodes have serious affects on ranging algorithms estimating locations of mobile nodes. The low rate UWB, IEEE802.15.4a, describes asynchronous two way ranging methods such as TWR and SDS-TWR working without any additional network synchronization, but the algorithms can not eliminate the effect of clock frequency differences. Therefore, the mechanisms to characterize the crystal difference is essential in typical UWB PHY implementations. In high rate UWB, characterizing of crystal offset with tracking loop is not required. But, detection of the clock frequency offset between the local clock and remote clock can be performed if there is little noise induced jitter. In this paper, we complete related ranging equations of high rate UWB based on TWR with relative frequency offset, and analyze a residual error in the ideal equations. We also evaluate the performance of the relative frequency offset algorithm by simulation and analyze the ranging errors according to the number of TWR to compensate coarse clock resolution. The results show that the relative frequency offset compensation and many times of TWR enhance the performance to converge to a limited ranging errors even with coarse clock resolutions.

Regional Balanced Development Policy Leverage in the Capital and Non-Capital Areas : Focusing on Local Function Concentration and Dispersion Structure (수도권과 비수도권의 지역균형발전 정책 레버리지 탐색 : 지역의 기능 집중·분산 구조를 중심으로)

  • Lee, Jin-Hee;Lee, Man-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.502-512
    • /
    • 2019
  • To examine the problem structure of balanced regional development policy and identify the causes of the gap between the capital and non-capital areas, this study examined the causal structure in terms of the concentration and distribution of functions in the metropolitan area and non-capital area and explored the policy leverage. As a research method, the causal map was drawn using System Dynamics techniques and policy leverage was derived through an exploration of the feedback structure. In particular, the causes of the problems in balanced regional development policies were approached by system accidents rather than by single-circuit accidents, and causality analysis was performed among the variables constituting balanced regional development policies based on system accidents. In particular, it singled out 31 variables, developed 13 feedback loops, and confirmed four major policy leverages, including relocation of the capital function, local decentralization policies, consistent development, and investment practices centered on the Non­Capital Area. Subsequently, a follow-up study by computer simulation is needed by modeling the structure of the system to identify the ripple effect of the policies of the Capital Area on the Non­Capital Area.

Effects of Induction Heat Bending Process on Microstructure and Corrosion Properties of ASME SA312 Gr.TP304 Stainless Steel Pipes

  • Kim, Nam In;Kim, Young Sik;Kim, Kyung Soo;Chang, Hyun Young;Park, Heung Bae;Sung, Gi Ho
    • Corrosion Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.120-126
    • /
    • 2015
  • The usage of bending products recently have increased since many industries such as automobile, aerospace, shipbuilding, and chemical plants need the application of pipings. Bending process is one of the inevitable steps to fabricate the facilities. Induction heat bending is composed of compressive bending process by local heating and cooling. This work focused on the effect of induction heat bending process on the properties of ASME SA312 Gr. TP304 stainless steel pipes. Tests were performed for base metal and bended area including extrados, intrados, crown up, and down parts. Microstructure was analyzed using an optical microscope and SEM. In order to determine intergranular corrosion resistance, Double Loop Electrochemical Potentiokinetic Reactivation (DL-EPR) test and ASTM A262 practice A and C tests were done. Every specimen revealed non-metallic inclusion free under the criteria of 1.5i of the standard and the induction heat bending process did not affect the non-metallic inclusion in the alloys. Also, all the bended specimens had finer grain size than ASTM grain size number 5 corresponding to the grain sizes of the base metal and thus the grain size of the pipe bended by induction heat bending process is acceptable. Hardness of transition start, bend, and transition end areas of ASME SA312 TP304 stainless steel was a little higher than that of base metal. Intergranular corrosion behavior was determined by ASTM A262 practice A and C and DL-EPR test, and respectively step structure, corrosion rate under 0.3 mm/y, and Degree of Sensitization (DOS) of 0.001~0.075% were obtained. That is, the induction heat bending process didn't affect the intergranular corrosion behavior of ASME SA312 TP304 stainless steel.

An Experimental Study on Heat Transfer and Pressure Drop Characteristics of Carbon Dioxide During Gas Cooling Process in a Hellically Coiled Tube

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Yu, Tae-Geun;Kim, Dae-Hui
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.263-271
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during 9as cooling process of $CO_2$ (R744) in a helically coiled copper tube with the inner diameter of 4.55 mm and outer diameter of 6.35 mm were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter a pre-heater and a helically coiled type gas cooler (test section). The refrigerant mass fluxes are varied from 200 to $800kg/m^2s$ and the inlet pressures of gas cooler are 7.5 to 10.0 MPa. The heat transfer coefficients of $CO_2$ in a helically coiled tube are higher than those in a horizontal tube. The Pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those predicted by Ito's correlation developed for single-phase in a helically coiled tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However. at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al correlation. Therefore, various experiments in helically coiled tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in a helically coiled tube.

An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-2) (지하수류가 밀폐형 천공 지중 열교환기 성능에 미치는 영향(2))

  • Hahn, Jeongsang;Kiem, Youngseek;Lee, Juhyun;Lee, Byoungho;Hahn, Chan
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.114-127
    • /
    • 2016
  • An increase of groundwater flux in BHE system creates that ground temperature (locT) becomes lower in summer and higher in winter time. In other words, it improves significantly the performance of BHE system. The size of thermal plume made up by advection driven-flow under the balanced energy load is relatively small in contrast to the unbalanced energy load where groundwater flow causes considerable change in the size of thermal plume as well ground temperature. The ground temperatures of the up gradient and down gradient BHEs under conduction only heat transport are same due to no groundwater flow. But a significant difference of the ground temperature is observed between the down gradient and up gradient BHE as a result of groundwater flow-driven thermal interference took placed in BHE field. As many BHEs are designed under the obscure assumption of negligible groundwater flow, failure to account for advection can cause inefficiencies in system design and operation. Therefore including groundwater flow in the design procedure is considered to be essential for thermal and economic sustain ability of the BHE system.

Vortex dynamics in YBa$_2Cu_3O_7$ single crystals measured by micro Hall-probe array (Micro Hall probe array를 이용한 YBa$_2Cu_3O_7$ 단결정 내부의 자속 운동 측정)

  • Shim, Seong-Yeop;Hwang, Hyeon-Guk;Lee, Chang-Woo;Lee, Tae-Won;Kim, Dong-Ho
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.189-195
    • /
    • 1999
  • We have studied the vortex dynamics in YBa$_2Cu_3O_7$ single crystals with columnar defects using micro Hall-probe array. The Hall-probe array technique allowed a simultaneous measurement of the time and spatial dependence of the vortex density so that more detailed information on flux dynamics could be obtained. We found that field profiles inside sample were similar to the Bean's critical state model from the magnetic hysteresis measurement. Normalized relaxation rates were maximum near the center and decreased toward the edge if applied field H$_{app}$ is greater than the penetration field H. But applied magnetic field H$_{app}$ is less than H, relaxation rates were minimum near the center and increased toward edge. We found that glassy exponent ${\mu}$ has the value of ${\sim}$ 1 whose corresponding vortex motion is half-loop excitation. However, single vortex creep, ${\mu}$ ${\sim}$ 1/7, was also found at 30 K and H$_{app}$ ${\cong}$ H'. Calculation of activation energy, U, was possible from direct analysis of the local relaxation data using the basic diffusion equation. From these results, we found that U increases logarithmically with time and U around center was lower than that at the edge.

  • PDF

A Hyper Suprime-Cam View of the Interacting Galaxies of the M81 Group - Structures and Stellar Populations

  • Arimoto, Nobuo;Okamoto, Sakurako
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.39.2-39.2
    • /
    • 2017
  • Over the last decade, deep studies of nearby galaxies have led to the discovery of vast stellar envelopes that are often rich in substructure. These components are naturally predicted in models of hierarchical galaxy assembly, and their observed properties place important constraints on the amount, nature, and history of satellite accretion. One of the most effective ways of mapping the peripheral regions of galaxies is through resolved star studies. Using wide-field cameras equipped to 8 m class telescopes, it has recently become possible to extend these studies to systems beyond the Local Group. Located at a distance of 3.6 Mpc, M81 is a prime target for wide-field mapping of its resolved stellar content. In this talk, we present the detailed results from our deep wide-field imaging survey of the M81 group with the Hyper Suprime-Cam (HSC), on the Subaru Telescope. We report on the analysis of the structures, stellar populations, and metallicities of old dwarf galaxies such as NGC3077, IKN, KDG061, as well as young stellar systems such as Arp's Loop and Holmberg IX. Several candidates for yet-undiscovered faint dwarf galaxies and young stellar clumps in the M81 group will also be introduced. The peculiar galaxy NGC3077 has been classified as the irregular galaxy. Okamoto et al. (2015, ApJ 809, L1) discovered an extended halo structure with S-shape elongated tails, obvious feature of tidal interaction. With a help of numerical simulation by Penarrubia et al. (2009, ApJ 698, 222), we will demonstrate that this tidal feature was formed during the latest close encounters between M81, M82, and NGC 3077, which induced star formation in tidally stripped gas far from the main bodies of galaxies. It is not clear whether the latest tidal interaction was the first close encounters of three galaxies. If NGC3077 is still surrounded by the dark matter halo, it implies that NGC3077 has undergone the first tidal stripping by larger companions. Kinematic studies of inter galactic globular clusters and planetary nebulae would tell us the past history of tidal interaction in this group of galaxies.

  • PDF

Cooling Heat Transfer Characteristics of CO2 in Helical Coil Type Gas Coolers (헬리컬 코일형 가스냉각기 내 CO2의 냉각 열전달 특성)

  • Son, Chang-Hyo;Jeon, Min-Ju;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.699-706
    • /
    • 2007
  • The cooling heat transfer coefficient and pressure drop of $CO_2$(R-744) in helical coil copper tubes were investigated experimentally The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter. a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55mm inner diameter The refrigerant mass fluxes were varied from 200 to $600 [kg/m^2s]$ and the inlet pressures of 9as cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively food agreement with those Predicted by Ito's correlation developed for single-phase in helical coil tubes. Though a few correlation available with the data. the local heat transfer coefficient of $CO_2$ agrees well with those presented by Pitla et al. among the predictions. However at the region near pseudo-critical temperature. the experiment data indicate higher values than the Pitla et al. correlation.

Heat Transfer Characteristics of Inclined Helical Coil Type Heat Exchanger (경사진 헬리컬 코일 열교환기의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo;Jeon, Min-Ju;Jang, Seong-Il;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.707-714
    • /
    • 2007
  • The heat transfer coefficient and Pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45mm inner diameter. The refrigerant mass fluxes were varied from 200 to $600[kg/m^2s]$ and the inlet Pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increases with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those Predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However, at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al. correlation. Therefore. various experiments in the inclined helical coil tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in the inclined helical coil tubes.

Experimental and numerical investigation of the seismic performance of railway piers with increasing longitudinal steel in plastic hinge area

  • Lu, Jinhua;Chen, Xingchong;Ding, Mingbo;Zhang, Xiyin;Liu, Zhengnan;Yuan, Hao
    • Earthquakes and Structures
    • /
    • v.17 no.6
    • /
    • pp.545-556
    • /
    • 2019
  • Bridge piers with bending failure mode are seriously damaged only in the area of plastic hinge length in earthquakes. For this situation, a modified method for the layout of longitudinal reinforcement is presented, i.e., the number of longitudinal reinforcement is increased in the area of plastic hinge length at the bottom of piers. The quasi-static test of three scaled model piers is carried out to investigate the local longitudinal reinforcement at the bottom of the pier on the seismic performance of the pier. One of the piers is modified by increased longitudinal reinforcement at the bottom of the pier and the other two are comparative piers. The results show that the pier failure with increased longitudinal bars at the bottom is mainly concentrated at the bottom of the pier, and the vulnerable position does not transfer. The hysteretic loop curve of the pier is fuller. The bearing capacity and energy dissipation capacity is obviously improved. The bond-slip displacement between steel bar and concrete decreases slightly. The finite element simulations have been carried out by using ANSYS, and the results indicate that the seismic performance of piers with only increasing the number of steel bars (less than65%) in the plastic hinge zone can be basically equivalent to that of piers that the number of steel bars in all sections is the same as that in plastic hinge zone.