• Title/Summary/Keyword: load following

Search Result 937, Processing Time 0.029 seconds

A Modified Equation of Parameter of Free-air Blast Load (자유 공중 폭발하중 파라메타의 수정 산정식)

  • Jeon, Doo-Jin;Lee, Min-Jae;Han, Sang-Eul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.117-123
    • /
    • 2016
  • The blast load is classified into free-air blast and surface blast following the location of explosion and surface. In this paper, several equations for blast load calculation are explained briefly and a modified equation for free-air blast load is suggested. The modified equation is based on Kingery-Bulmash equation which is used in UFC 3-340-02 and Conwep model. In this modified equation, the process of calculation is simplified against the original equation, and the number of coefficients is reduced under 5. As a result, each parameter of estimated data by modified equation has less than 1% of error range comparing with Kingery-Bulmash equation.

Study on Load Following Characteristics of Generators during Start-up of Induction Motor Load in Isolated System (독립계통에서 유도전동기 부하의 기동시 발전기의 안정적 부하추종에 관한 연구)

  • Shin, Ho-Jeon;Huh, Jae-Sun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.80-85
    • /
    • 2015
  • Recently, not only in the Middle East and Southeast Asia but in African area, too, industrial plant construction is being actually done. But unlike in Korea, a lot of them are small-scale isolated industrial plants. And because of the characteristics of industrial plants, induction motors' load forms a large part. The influence of stability resulted from the maneuver and operation of induction motors' load may lead to serious result in the isolated system. This study analyzed it through mathematical modeling on induction motors' maneuver phenomena in the isolated system, realized a case system with the E-TAP program, and simulated load follow performances according to the control variables of a generator inside the isolated system.

An Analysis of Delayed Voltage Recovery Phenomenon according to the Characteristics of Motor Load in Korean Power System (모터부하 특성에 따른 국내 전력계통의 전압 지연 회복 현상 분석)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.178-182
    • /
    • 2016
  • FIDVR(Fault Induced Delayed Voltage Recovery) is a phenomenon that recovery of the system voltage level delays after the fault. Cause of FIDVR phenomenon is motor load characteristic about voltage and reactive power. In low voltage condition, the motor go to stall state that consume large amount of reactive power. As a result, the voltage recovery problem is that of repeated occurrences of sustained low voltage following faults on the system. In this paper, analysis the characteristics of the motor load. And using the korean power system actual data, perform a case studies to voltage delay recovery phenomenon alleviation method. Change of each parameters by analyzing the effect on system and selecting an influence parameter. In addition, dynamic characteristic analysis of the resulting difference in the proportion by the motor load in power systems, considering the effect on the voltage stability.

Characteristics of Vertical Stress Distribution in Sandy Soil According to the Relative Compaction and Composition of the Soil Layer (사질토 지반의 상대다짐도 및 토층에 따른 연직지중응력 분포 특성)

  • Nam, Hyo-Seok;Lee, Sang-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.43-50
    • /
    • 2010
  • This study was carried out to evaluate the vertical stress properties in sandy soil according to changes of foundation condition in soil bin compacted three layers. The following conclusions and comparisons have been made based on careful analysis from theoretical and experimental methods. : When sandy soil subjected to circular uniform load, the vertical stress increments ($\Delta\sigma_z$) was increased as load increasing, the maximum values of $\Delta\sigma_z$ was achieved at the point loading axis, and $\Delta\sigma_z$ was not shown over at a distance of three times of loading plate width (B). The vertical stress increments were achieved largely at 80 % relative compaction (Rc) compared to 95 % relative compaction due to stress concentration in sandy soil. When sandy soil subjected to circular uniform load, the $\Delta\sigma_z$ differences between theoretical and experimental values as load increased were more increased and its maximum differences were achieved at stress axis. When gravel surface macadamized over sandy soil subjected to load, the $\Delta\sigma_z$ was concentrated to load axis as load increasing, so that macadamization will be decreased load transmission.

A Study on Simultaneous Load Factor of Intelligent Electric Power Reduction System in Korea (한국의 지능형 전력동시부하율 저감시스템에 관한 연구)

  • Kim, Tae-Sung;Lee, Jong-Hwan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.1
    • /
    • pp.24-31
    • /
    • 2012
  • This study is designed to predict the overall electric power load, to apply the method of time sharing and to reduce simultaneous load factor of electric power when authorized by user entering demand plans and using schedules into the user's interface for a certain period of time. This is about smart grid, which reduces electric power load through simultaneous load factor of electric power reduction system supervision agent. Also, this study has the following characteristics. First, it is the user interface which enables authorized users to enter and send/receive such data as demand plan and using schedule for a certain period of time. Second, it is the database server, which collects, classifies, analyzes, saves and manages demand forecast data for a certain period of time. Third, is the simultaneous load factor of electric power control agent, which controls usage of electric power by getting control signal, which is intended to reduce the simultaneous load factor of electric power by the use of the time sharing control system, form the user interface, which also integrate and compare the data which were gained from the interface and the demand forecast data of the certain period of time.

A Study of Product Simulation for Establishing the Optimal Production Scheduling of the Panel line in a Shipyard (조선소 판넬라인의 최적 생산계획 수립을 위한 생산 시뮬레이션 연구)

  • Park, Ju-Yong;Kim, Se-Hwan;Choi, Woo-Hyun
    • Journal of Welding and Joining
    • /
    • v.24 no.5
    • /
    • pp.62-66
    • /
    • 2006
  • Panel line is an important process occupying the largest work amount in shipbuilding. In this research product simulation has been carried out to establish the optimal production scheduling. For this purpose a web-based panel line simulator was developed using an object modeling technology and C# language. The balance of work-load and increase in the productivity by the improvement of production facilities and process are the key factors for a good scheduling. In this study SPRT(Shortest Remaining Process Time) rule was applied for the work-load balancing and a good result achieved. To increase the productivity in the stiffener welding stage which is a bottleneck; process, more welding heads and higher welding speed were tested using the developed simulator. The simulation results showed that either more welding head or higher welding speed decreased the total work time. Use of both, however, deteriorated the productivity because of the bottleneck in the following stage. This result points out that the improvement of production facilities and/or process should be evaluated with their influences on the leading and following processing stage.

Optimization for Xenon Oscillation in Load Following Operation of PWR (가압경수형 원자로 부하추종 운전시 제논진동 최적화)

  • 김건중;오성헌;박인용
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.11
    • /
    • pp.861-869
    • /
    • 1989
  • The optimization problems, based on Pontryagin's Maximum Principle, for minimizing (damping) Xenon spatial oscillations in Load Following operations of Pressurized Water Reactor (PWR) is presented. The optimization model is formulated as an optimal tracking problem with quadratic objective functional. The oen-group diffusion equations and Xe-I dynamic equations are defined as equality constraints. By applying the maximum principle, the original problem is decomposed into a single time problem with no constraints. The resultant subproblems are optimized by using the conjugate Gradient Method. The computational results show that the Xenon spatial oscillation is minimized, and the reactor follows the load demand of the electrical power systems while maintaining the desired power distribution.

A Takagi-Sugeno fuzzy power-distribution method for a prototypical advanced reactor considering pump degradation

  • Yuan, Yue;Coble, Jamie
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.905-913
    • /
    • 2017
  • Advanced reactor designs often feature longer operating cycles between refueling and new concepts of operation beyond traditional baseload electricity production. Owing to this increased complexity, traditional proportional-integral control may not be sufficient across all potential operating regimes. The prototypical advanced reactor (PAR) design features two independent reactor modules, each connected to a single dedicated steam generator that feeds a common balance of plant for electricity generation and process heat applications. In the current research, the PAR is expected to operate in a load-following manner to produce electricity to meet grid demand over a 24-hour period. Over the operational lifetime of the PAR system, primary and intermediate sodium pumps are expected to degrade in performance. The independent operation of the two reactor modules in the PAR may allow the system to continue operating under degraded pump performance by shifting the power production between reactor modules in order to meet overall load demands. This paper proposes a Takagi-Sugeno (T-S) fuzzy logic-based power distribution system. Two T-S fuzzy power distribution controllers have been designed and tested. Simulation shows that the devised T-S fuzzy controllers provide improved performance over traditional controls during daily load-following operation under different levels of pump degradation.

Dyamic Modeling and Analysis of Air Supply System for Vehicular PEM Fuel Cell (고분자 전해질형 연료전지 자동차의 급기 시스템의 동적 모델링 및 분석)

  • Jang, HyunTak
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.3
    • /
    • pp.175-186
    • /
    • 2004
  • In this paper, we developed the dynamic model of a fuel cell system suitable for controller design and system operation. The transient phenomena captured in the model include the flow characteristics and inertia dynamics of the compressor, the intake manifold filling dynamics, oxygen partial pressures and membrane humidity on the fuel cell voltage. In the simulations, we paid attention to the transient behavior of stack voltage and compressor pressure, stoichiometric ratio. Simulation results are presented to demonstrate the model capability. For load current following, stack voltage dynamic characteristics are plotted to understand the Electro-chemistry involved with the fuel cell system. Compressor pressure and stoichiometric ratio are strongly coupled, and independent parameters may interfere with each other, dynamic response, undershoot and overshoot.

A Study on Regenerative Braking of Electric Vehicle (전기자동차 회생제동에 관한 연구)

  • Jeon, Beom-Jin;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.290-292
    • /
    • 1995
  • In this paper, the regenerative braking control system for 4 WD Electric Vehicle (EV) is proposed. Many studies on efficient drive of EV are being done to prolong the one charge distance. By using the regenerative braking (REGEN), the resulting EV system has following advantages : a) battery is recharged with the mechanical energy of EV, b) the running load can be reduced, and consequently the efficiency can be increased. The problem of REGEN that the power acceptance ability of battery is limited can be solved by controlling regenerative braking torque. The proposed control system has following characteristics. : a) It controls regenerative power by varying mechanical braking torque. b) It controls mechanical braking torque using load torque observer. c) It controls the regenerative braking torque independently. The control scheme and simulation results are presented for the experimental car.

  • PDF