• 제목/요약/키워드: load - reducing

검색결과 1,091건 처리시간 0.028초

가정노동의 지원체계확립을 위한 연구 (A Study on the Supporting Systeim to Household Work)

  • 정영금
    • 가정과삶의질연구
    • /
    • 제17권3호
    • /
    • pp.83-92
    • /
    • 1999
  • Many Policies were made to increase women's employment since the latter half of the 1980s in Korean. But work-family conflict of married women can not be solved without reducing the household work load, because all of Korean wives have the responsibilities of household work. So this study aims to establish the supporting system of household work in the women's policies. For this purpose this study examine the actual conditions for supporting the household work. And supporting system and strategies for policy making related to household work and suggested. Supporting system includes arrangement in household raise in social consciousness improvement of market circumstance establishment of relating acts and public facilities.

  • PDF

전류원 인버터로 구동되는 유도전동기의 맥동토오 (Steady-State Torque Pulsations in Current Source Inverter Fed Induction Motor Drives)

  • 신휘범;윤명중
    • 대한전기학회논문지
    • /
    • 제37권4호
    • /
    • pp.197-204
    • /
    • 1988
  • A simple method that estimates the torque fluctuations in induction motor driven by CSI under steady state condition is presented and that uses the phasor diagram from the modified singlephase equivalent circuit. This method is also applied to evaluate the PWM and programmed do link modulation techniques for reducing the torque pulsations. The simplified calculations are compared with the exact digital solutions from machine D-Q equation. It is noted that the torque pulsations in induction motor driven by CSI are dependent upon the load condition unlike VSI.

  • PDF

블록 구조물 적치용 지지대의 빔 이론 기반 구조 안전성 평가법 (Simplistic Beam Theory-based Structural Safety Evaluation Method for Block Structure on the A-Carrier)

  • 이명수;박주신
    • 해양환경안전학회지
    • /
    • 제30권4호
    • /
    • pp.358-364
    • /
    • 2024
  • 선박 건조 과정에서 블록이나 장비를 지지하는 A형 캐리어 구조는 하중 변경과 시간이 지남에 따라 점차 변형이 증가하며, 이에 따라 블록과 접촉하는 면적이 감소하고 분산된 하중에서 집중된 하중으로 패턴이 변화한다. 이러한 현상은 실제 사용 하중을 오판할 가능성이 있다. 특히 A형 캐리어는 영세한 제조 업체에서 자주 사용하고 있으며, 별도의 엔지니어링 기능이 없는 상황이 대부분이라서 손쉽게 캐리어의 안전사용하중을 계산하는 방법의 개발이 필요하다. 본 연구는 A형 캐리어가 장기적으로 안전하게 사용할 수 있는 하중을 신속하게 평가하는 방법을 제안함으로써, 하중 분포의 변화에 따른 소성 변형과 그로 인한 안전 문제를 예측하고 대응할 수 있다. 제안된 방법은 캐리어의 중앙 집중하중과 전체 분포하중 조건에 대해서 유한요소해석(빔, 쉘 모델링)을 통한 결과를 기반으로 빔-이론을 수정하여 제안되었다. 빔 모델링에서 집중하중 조건은 보정계수 0.73, 분포하중에서는 0.69를 이론값에 곱해서 안전사용하중이 가능하다. 쉘 모델링의 경우, 집중하중은 0.75와 분포하중은 0.69를 사용할 수 있다. 본 연구는 선박 건조 작업 현장의 안전을 개선하고, 실제 작업 환경에서의 안전 사용 하중 판단에 신속하고 효과적인 결정을 내릴 수 있는 기초 자료로 활용될 수 있다.

고분자전해질 연료전지 내구성 향상을 위한 시동 기술 개발에 관한 연구 (Development of a Durable Startup Procedure for PEMFCs)

  • 김재홍;조유연;장종현;김형준;임태훈;오인환;조은애
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.288-294
    • /
    • 2009
  • Various polymer electrolyte membrane fuel cell (PEMFC) startup procedures were tested to explore possible techniques for reducing performance decay and improving durability during repeated startup-shutdown cycles. The effects of applying a dummy load, which prevents cell reversal by consuming the air at the cathode, on the degradation of a membrane electrode assembly (MEA) were investigated via single cell experiments. The electrochemical results showed that application of a dummy load during the startup procedure significantly reduced the performance decay, the decrease in the electrochemically active surface area (EAS), and the increase in the charge transfer resistance ($R_{ct}$), which resulted in a dramatic improvement in durability. After 1200 startup-shutdown cycles, post-mortem analyses were carried out to investigate the degradation mechanisms via various physicochemical methods including FESEM, an on-line $CO_2$ analysis, EPMA, XRD, FETEM, SAED, FTIR. After 1200 startup-shutdown cycles, severe Pt particle sintering/agglomeration/dissolution and carbon corrosion were observed at the cathode catalyst layer when starting up a PEMFC without a dummy load, which significantly contributed to a loss of Pt surface area, and thus to cell performance degradation. However, applying a dummy load during the startup procedure remarkably mitigated such severe degradations, and should be used to increase the durability of MEAs in PEMFCs. Our results suggest that starting up PEMFCs while applying a dummy load is an effective method for mitigating performance degradation caused by reverse current under a repetition of unprotected startup cycles.

  • PDF

고속도로 노면 강우유출 오염부하 원단위 산정 (Analysis of Unit Pollution Load on Highway runoff)

  • 강희만;이두진;배우근
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.55-68
    • /
    • 2012
  • Impervious surface increase due to urbanization, one of the leading causes of pavement increased the runoff coefficient, peak flow, and reducing the infiltration flow and thereby causing flooding and river erosion is occurring in aquatic ecosystems are known to impair. This study aimed to classify use type of detailed land into the road, reststop, tollgates and etc. focused on major domestic highways, to understand the characteristics of rainfall runoff pollutants and to calculate applicable unit pollution load. Because of high runoff coefficient and short travel time to drainage. first flush occurred clearly. Average EMCs of runoff in the highway was investigated as TSS 108.47 mg / L, COD 28.16 mg / L, BOD 13.61 mg / L, TN 6.38 mg / L, TP 0.03 mg / L, Cu 118.17 ${\mu}g$ / L, Pb 345.3 ${\mu}g$ / L, Zn 349.47 ${\mu}g$ / L. Unit pollution loads calculated by detailed land use area of highways based on average annual rainfall, EMCs, applicable basin areas and etc. were 46.6 kg/km2/day of BOD, 1.4 kg/km2/day of TP, 8.81 kg / km2/day of TN and these were BOD 50.8%, TP 66.7%, TN 64.4%in comparison of the unit pollution loads which applies fallow land standards of the TMDL(Total Maximum Daily Load). It was considered that discharged loads can be excessively calculated in case highway non-point management plans based on unit pollution load of the current land standard.

성토지지말뚝에 작용하는 연직하중에 대한 모형실험 (Model Tests for Vertical Loads Acting on Embankment Piles)

  • 홍원표;강승인
    • 한국지반공학회논문집
    • /
    • 제16권4호
    • /
    • pp.171-181
    • /
    • 2000
  • 성토지지말뚝 상부의 성토지반내에서 발생되는 지반아칭효과에 의하여 성토하중이 말뚝에 전달되는 효과를 조사하면서 제안된 이론해석의 신뢰성을 확인하기 위하여 일련의 모형실험을 수행하였다. 본 모형실험에서 말뚝은 성토 아래에 일렬로 수열의 줄말뚝으로 설치하였으며, 말뚝캡보는 성토의 길이방향에 직각방향으로 말뚝두부에 설치하였다. 성토재의 하중전달에 가장 큰 영향을 미치는 요인으로는 말뚝캡보사이의 간격과 성토고를 들 수 있다. 이전의 이론적인 연구에 의해 제안된 지반아치의 반경보다 약 33%정도 큰 최소소요성토고보다 높게 성토를 실시할 경우 지반아치는 완벽하게 발생될 뿐만 아니라, 실험치와 이론치는 잘 일치함을 모형실험결과 확인할 수 있다. 모형말뚝캡보에 작용하는 성토하중의 분담률은 말뚝캡보사이의 간격이 증가함에 따라 감소하는 반면, 성토고가 높아짐에 따라 증가하였다. 따라서, 설계시 말뚝의 성토하중지지효과를 극대화시키기 위해서는 성토고를 충분히 높게한 상태에서 말뚝캡보의 간격비를 감소시켜야 한다. 여기서 말뚝캡보의 간격비를 감소시키려면 말뚝캡보사이의 간격을 감소시키거나 말뚝캡보의 폭을 증가시켜야 한다.

  • PDF

말뚝 강성을 고려한 지반의 지진하중 저감 효과에 관한 해석 연구 (Analysis on the Seismic Load Reduction Effect of a Ground by Considering Pile Strength)

  • 김상연;박종배;박용부;김동수;이세현
    • 토지주택연구
    • /
    • 제3권4호
    • /
    • pp.451-456
    • /
    • 2012
  • 최근에 건설되는 고층 건물들은 지하 3층 이상의 깊은 지하층을 갖는 경우가 일반적이며, 이 경우에 국내 지반의 특성상 기반암 깊이가 얕아 지하층하부가 암반에 장착되거나 지중에 위치하는 경우가 많다. 현행 우리나라 내진설계기준의 지진하중은 자유장인 지표면에서의 응답을 바탕으로 하고 있어 말뚝이 매설된 기초 하부 지반에서의 지진하중과 상이하므로 비교 및 검증이 요구된다. 이를 위하여 본 연구에서는 2차원 동적(2D Dynamic) 수치해석 기법을 이용하여 말뚝기초가 기반암에 근입될 때 말뚝 강성효과에 의한 기초저면에서의 지진하중 감소를 확인하였으며 경제적인 내진설계를 수행할 수 있는 가능성을 확인해 보았다. 현행 내진 설계기준에 따른 자유장 지표면 가속도를 설계 지진 하중산정 과정에서 말뚝 강성을 고려한 지진 하중 저감효과를 평가하기 위해 PLAXIS 2D 프로그램을 사용하여 말뚝 개수 4개, 8개, 12개인 세가지 말뚝 배치 경우에 대하여 지중 및 기초상부의 최대 지진 가속도와 동일 깊이의 자유장 최대 지진 가속도를 수치해석을 통하여 비교한 결과, 지반내 매설된 말뚝 기초에 의해 20~25%가량의 지진하중 저감효과가 있는 것을 확인하였다. 그러나 말뚝의 개수 및 콘크리트 기초의 크기는 지진응답 특성에 큰 영향을 미치지 않는 것으로 평가되었다.

Effect of pile group geometry on bearing capacity of piled raft foundations

  • Fattah, Mohammed Y.;Yousif, Mustafa A.;Al-Tameemi, Sarmad M.K.
    • Structural Engineering and Mechanics
    • /
    • 제54권5호
    • /
    • pp.829-853
    • /
    • 2015
  • This is an experimental study to investigate the behaviour of piled raft system in different types of sandy soil. A small scale "prototype" model was tested in a sand box with load applied to the foundation through a compression jack and measured by means of load cell. The settlement was measured at the raft by means of dial gauges, three strain gauges were attached on piles to measure the strains and calculate the load carried by each pile in the group. Nine configurations of group ($1{\times}2$, $1{\times}3$, $1{\times}4$, $2{\times}2$, $2{\times}3$, $2{\times}4$, $3{\times}3$, $3{\times}4$ and $4{\times}4$) were tested in the laboratory as a free standing pile group (the raft not in contact with the soil) and as a piled raft (the raft in contact with the soil), in addition to tests for raft (unpiled) with different sizes. It is found that when the number of piles within the group is small (less than 4), there is no evident contribution of the raft to the load carrying capacity. The failure load for a piled raft consisting of 9 piles is approximately 100% greater than free standing pile group containing the same number of piles. This difference increases to about 4 times for 16 pile group. The piles work as settlement reducers effectively when the number of piles is greater than 6 than when the number of piles is less than 6. The settlement can be increased by about 8 times in ($1{\times}2$) free standing pile group compared to the piled raft of the same size. The effect of piled raft in reducing the settlement vanishes when the number of piles exceeds 6.