• Title/Summary/Keyword: liver scan

Search Result 219, Processing Time 0.021 seconds

Diffuse Hepatic Uptake of $^{99m}Tc$-DPD on Whole Body Bone Scan: The Influence of MRI Contrast (전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취: MRI 조영제의 영향)

  • Yun, Jong Jun;Jeong, Ji Uk;Hwang, Ju Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose : The whole body bone scan on nuclear medicine is a widely accepted examination and procedure. However, unusual nonosseous uptake can be observed, which reflects a rare interaction between the radiopharmacceutical and the patient. This study aimed to evaluate the influence of MRI(Magnetic Resonance Imaging) contrast and $^{99m}Tc$-DPD(Dicarboxpropane diphosphonate) on whole body bone scan. Materials and Methods : We analyzed the 982 patients who were examined by $^{99m}Tc$-DPD on whole body bone scan in nuclear medicine department of pusan national university hospital from january to december 2010. All these 982 patients had MRI contrast administration prior to whole body bone scan. We analyzed laboratory test. Results : 46 patients(men 39, women 7) showed diffuse hepatic uptake on whole body bone scan. These uptakes were disappeared on the follow-up whole body bone scan. There were no significant difference of CBC test, liver function tests and renal function tests. Conclusion : The study might be an indirect evidence that diffuse hepatic and splenic uptake of 99mTc-DPD on whole body bone scan after intravenous administration of Gadolinium(Gd) MRI contrast. To perform a precise examination, Gd-contrast agent should be removed from the body before performing a whole body bone scan.

  • PDF

A Case of Hepatopulmonary Syndrome Diagnosed by $^{99m}Tc-MAA$ Perfusion Lung Scan ($^{99m}Tc-MAA$ 폐관류스캔으로 진단한 간폐증후군)

  • Oh, Hyung-Tae;Lee, Moo-Yong;Song, Il-Han;Park, Seok-Gun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.203-208
    • /
    • 2002
  • In patients with chronic liver disease, hepatopulmonary syndrome, the right to left shunt without previous pulmonary and cardiac disease, can develope and cause respiratory distress. Tools to prove shunt are contrast echocardiography, pulmonary angiography, and $^{99m}Tc-MAA$ perfusion lung scan. Among them, $^{99m}Tc-MAA$ scan is a simple and safe method detecting the right to left shunt. At the same time, quantitation of shunt amount is possible by this method. We report a case of hepatopulmonary syndrome confirmed by $^{99m}Tc-MAA$ scan and contrast echocardiography with review of literlatures.

Transient Diffuse Hepatic Uptake of $^{99m}Tc$-MDP after Hepatitis B Vaccination (B형 간염 백신 접종 후 일시적으로 관찰된 $^{99m}Tc$-MDP의 미만성 간 섭취)

  • Kim, Hyun-Jin;Park, Young-Ha;Hwang, Seong-Su;Kim, Sang-Heum;Chung, Soo-Kyo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.48-50
    • /
    • 2006
  • A 38-year-old female with arthralgia in right elbow joint for 6 months was referred for a bone scan which showed diffuse uptakes of $^{99m}Tc$-MDP in the liver and spleen without hepatosplenomegaly. She had a history of hepatitis B vaccination 3 days ago. These uptakes were disappeared on the follow-up bone scan after 4 months. We suggest this transient diffuse hepatic uptake after vaccination of hepatitis B might be due to aluminum component within the hepatitis B vaccine as adjuvant.

Neuroendocrine Tumor of Unknown Primary Accompanied with Stomach Adenocarcinoma

  • Kim, Ho-Yeun;Choi, Sung-Il;Kim, Young-Ho
    • Journal of Gastric Cancer
    • /
    • v.11 no.4
    • /
    • pp.234-238
    • /
    • 2011
  • A 67 year old male at a regular checkup underwent esophagogastroduodenoscopy. On performing esophagogastroduodenoscopy, a lesion about 1.2 cm depressed was noted at the gastric angle. The pathology of the biopsy specimen revealed a well-differentiated adenocarcinoma. On performing an abdominal computed tomography (CT) scan & positron emission tomography-computed tomography (PET-CT) scan, no definite evidence of gastric wall thickening or mass lesion was found. However, lymph node enlargement was found in the left gastric and prepancreatic spaces. This patient underwent laparoscopic assisted distal gastrectomy and D2 lymph node dissection. On final examination, it was found out that the tumor had invaded the mucosal layer. The lymph node was a metastasized large cell neuroendocrine carcinoma with an unknown primary site. The patient refused chemotherapy. He opted to undergo a close followup. At the postoperative month 27, he had a focal hypermetabolic lesion in the left lobe of the liver that suggested metastasis on PET-CT scan. He refused to undergo an operation. He underwent a radiofrequency ablation.

A New Hyper Parameter of Hounsfield Unit Range in Liver Segmentation

  • Kim, Kangjik;Chun, Junchul
    • Journal of Internet Computing and Services
    • /
    • v.21 no.3
    • /
    • pp.103-111
    • /
    • 2020
  • Liver cancer is the most fatal cancer that occurs worldwide. In order to diagnose liver cancer, the patient's physical condition was checked by using a CT technique using radiation. Segmentation was needed to diagnose the liver on the patient's abdominal CT scan, which the radiologists had to do manually, which caused tremendous time and human mistakes. In order to automate, researchers attempted segmentation using image segmentation algorithms in computer vision field, but it was still time-consuming because of the interactive based and the setting value. To reduce time and to get more accurate segmentation, researchers have begun to attempt to segment the liver in CT images using CNNs, which show significant performance in various computer vision fields. The pixel value, or numerical value, of the CT image is called the Hounsfield Unit (HU) value, which is a relative representation of the transmittance of radiation, and usually ranges from about -2000 to 2000. In general, deep learning researchers reduce or limit this range and use it for training to remove noise and focus on the target organ. Here, we observed that the range of HU values was limited in many studies but different in various liver segmentation studies, and assumed that performance could vary depending on the HU range. In this paper, we propose the possibility of considering HU value range as a hyper parameter. U-Net and ResUNet were used to compare and experiment with different HU range limit preprocessing of CHAOS dataset under limited conditions. As a result, it was confirmed that the results are different depending on the HU range. This proves that the range limiting the HU value itself can be a hyper parameter, which means that there are HU ranges that can provide optimal performance for various models.

A Study on the Intrapulmonary Shunt Measured by $^{99m}Tc$-MAA Perfusion Lung Scan ($^{99m}Tc$-MAA관류폐주사를 이용한 폐내단락에 관한 연구)

  • Choi, Jin-Myung;Kang, Chan-Kyu;Lee, Young-Hyun;Choi, Soo-Bong;Chung, Jae-Chun;Kim, Chong-Suhl
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.163-169
    • /
    • 1986
  • Intrapulmonary shunt was measured by $^{99m}Tc$-MAA perfusion tung scan. The study was included 76 patients. Significant amount of intrapulmonary shunt was observed in the pulmonary disease patients and liver disease patients. The shunt amount was correlated well with $PaO_2$ and $AaDO_2$ level. Further study is needed to search the various factors affecting the amount of intrapulmonary shunt.

  • PDF

Tetralogy of Fallot with Pulmonary Arteriovenous Fistula -A Case Report- (폐동정맥루를 동반한 팔로사징환자의 치험 -1례보고-)

  • 김상익;박국양;박철현;김정철;현성열;이재웅;이현우;이성재;김종호
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.257-261
    • /
    • 2000
  • Pulmonary arteriovenous fistula can occur in a variety of clinical situations including liver diseases, infections, metastatic carcinomas, systemic disorders, and after the palliation of congenital heart diseases. A 72-day-old male infant with Tetralogy of Fallot and pulmonary atresia underwent surgical correction without difficulty. However, ventilator weaning in the ICU failed initially because of an unexplained postoperative hypoxemia(FiO2: 0.8, PaO2: 40 mmHg, SaO2: 80∼90%). Postoperative follow-up lung perfusin scan at postoperative 15 days showed right-to-left shunt(33.6%) and ventilator weaning was performed on the 20th day after the operation (FiO2: 0.4, PaO2, 50mmHg, SaO2: 86.9%). Arterial oxygen saturation under room air was 80∼85% at 7 months postoperatively. One and half year follow-up lung perfusion scan showed decreased amount of right-to-left shunt (11.2%). We report a case with a review of the literatures.

  • PDF

Quantitative evaluation of hepatic function for pre- and post-surgery patients using deconvolution technique in Tc-99m DISIDA SCAN (Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 외과적 수술 전후의 간의 정량적 평가)

  • Kim, S.C.;Kim, D.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.366-369
    • /
    • 1997
  • In this study, we measured upper right, lower right, upper left region to find the optimal region which represent liver function. We found that the upper right region is optimal because of high accuracy and low standard deviation. For normal subjects all the calculated HEFs were greater than 100% and all those of abnormal ones were less than 80%. Thus HEF can be assumed to discriminate abnormal livers from normal ones. It was found that the patients with surgical operation would survive if both the pre-and the post-operative HEFs are greater than 50%. Therefore HEF method can be a good estimator for surgeon to determine the surgical operation and to evaluate remaining hepatic function after surgery as well as it is reliable and simple.

  • PDF

Evaluation of the Liver Cancer Diagnosis Function of PET-MRI Based on Decision Matrix Analysis (판정행렬분석을 통한 PET-MRI의 간암 진단성능 평가)

  • Kim, Jin-Eui;Kim, Jung-Soo;Choi, Nam-Gil;Han, Jae-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.50-59
    • /
    • 2017
  • To evaluate the capability of integrated PET-MRI, which has recently been utilized in the clinical practices, on the diagnosis of liver cancer, its utility was assessed by $2{\times}2$ decision matrix. The numbers of abnormal and normal decisions on the liver cancer were 98 and 51 cases, respectively, upon PET-MRI scan results of the subjects, and the numbers of positive and negative decisions were 103 and 62, respectively, upon cytopathologic results. Out of the two tests, 95 cases were shown as true-positive and 3 were false positive, while 62 were true negative and 5 were false negative. Upon the results of PET-MRI test, its sensitivity, specificity, false negative rate, and false positive rate were 95.00%, 95.38%, 0.05%, and 95.15%, respectively. Therefore, it is considered to have the high potential to use the determination of the stage before the surgery, detections of recurrence and remote metastasis, assessment of uncertain remote lymph node metastasis, and so on in the diagnosis of the liver cancer, and also for the clinical utility of PET-MRI to be sufficient by integrated diagnosis and follow up scan with pathological studies.

Inflammation Scan Using $^{99m}Tc-HMPAO$ Labelled Leukocytes ($^{99m}Tc-HMPAO$를 이용한 자가백혈구표지 및 그를 이용한 염증병소의 스캔)

  • Yang, Woo-Jin;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee;Kim, Hoon-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.219-223
    • /
    • 1989
  • Inflammation scan using radiolabelled leukocytes has high sensitivity and specificity. Several methods for labelling leukocytes have been evaluated using P-32 diisopropyl fluorophosphate (DFP-32), H-3 thymidine, Cr-51 chromate, Ga-67 citrate and Tc-99m-sulfur colloid. In-111-oxine has proved so far to be the most reliable agent for labelling leukocytes. In-111-oxine is, however, expensive, not easily available when needed, and its radiation dose to leukocytes is relatively high. Moreover, resolution of the resultant image is relatively poor. Tc-99m is still the agent of choice because of, as compared with the indium, its favorable physical characteristics, lower cost and availability. Now the technique for labelling the leukocytes with technetium is successfully obtained using the lipophilic HAPAO with higher efficiency for granulocytes than for other cells. With this technique it is possible to label leukocytes in plasma to improve the viability of the leukocytes. Inflammation scan using Tc-99m-HMPAO has been evaluated in several laboratories, and difference in methods for separation and labelling accounts for difference in efficiency, viability and biodistribution of the labelled leukocytes. We performed inflammation scan using leukocytes labelled with Tc-99m-HMPAO in three dogs 24 hours after inoculation of live E. Coli and A. Aureus in their right abdominal wall. We separated mixed leukocytes by simple sedimentation using 6% hetastarch (HES) and labelled the leukocytes with Tc-99m-HMPAO in 20% cell free plama diluted with phosphate buffer solution(Fig. 1). Uptake was high in the liver and spleen but is was minimal in the lungs on whole body scan. Kidneys and intestine showed minimal activity although it was high in the urinary bladder(Fig. 2). Uptake of labelled leukocytes in the inflammation site was do(mite on 2 hour-postinjection scan and abscess was clearly delineated on 24 hour-delayed scan with high target-to-nontarget ratio(Fig. 3, 4). Inflammation scan using mixed leukocytes labelled with Tc-99m-HMPAO is very sensitive and specific in early detection of inflammation.

  • PDF