• Title/Summary/Keyword: liquid-phase standard

Search Result 297, Processing Time 0.028 seconds

Quantitative Analysis of Lovastatin in Human Plasma and urine by Reversed-Phase High-Performance Liquid Chromatography (역상 고속액체크로마토그라프법을 이용한 혈장 및 뇨 중 로바스타틴의 정량)

  • Choi, Hye-Jin;Kim, Myoung-Min;Choi, Kyung-Eob
    • YAKHAK HOEJI
    • /
    • v.42 no.5
    • /
    • pp.473-479
    • /
    • 1998
  • Lovastatin (LOVA), a fungal metabolite isolated from cultures of Aspergillus terreus, is a competitive HMG-CoA reductase inhibitor used for the treatment of primary hyper cholesterolemia, and has also been shown to suppress growth in a variety of non-glioma tumor cell lines. A sensitive reversed-phase high-perfonnance liquid chromatographic method with ultraviolet (UV) absorbance detection has been developed to quantitate LOVA in human plasma and urine samples using liquid-liquid extraction procedure. Baseline separation of LOVA and internal standard, simvastatin was achieved on a Novapak $C_{18}$ analytical column with a mobile phase containing 0.025M $NaH_2PO_4$: CAN (35:65, v/v%), adjusted pH to 4.5. The flow rate was set at 1.5ml/min, and the column effluent was monitored by a UV detection at 238nm. The limit of quantification was determined to be 0.5${\mu}$g/ml while extraction efficiency of LOVA ranged from 73.4-82.9% at LOVA concentrations of 0.5 to 10${\mu}$g/ml. Good linearity with correlation coefficients greater than 0.999 was obtained in the range of LOVA concentrations from 0.5 to 10${\mu}$g/ml. The accuracy and the precision were proven excellent with relative standard deviation (RSD, %) and relative error (RE, %) of less than 4.2 and 4.0, respectively. Intraday precision, evaluated at five LOVA concentrations (0.5, 1, 2, 5, 10${\mu}$g/ml) and expressed as RSD ranged from 0-1.82% while the interday precision at the same concentrations ranged from 0.7-10.5%. The analytical method described was then successfully employed for the determination of LOVA concentrations in plasma samples obtained during a phase II clinical trial using high doses of LOVA (30-40mg/kg/day). This method could be further utilized for the ongoing pharmacolkinetic studies and therapeutic drug monitoring of the high-dose LOVA therapy in adenocarcinoma patients.

  • PDF

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.

Analysis of fatty acid methyl ester in bio-liquid by hollow fiber-liquid phase microextraction

  • Choi, Minseon;Lee, Soyoung;Bae, Sunyoung
    • Analytical Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.174-181
    • /
    • 2017
  • Bio-liquid is a liquid by-product of the hydrothermal carbonization (HTC) reaction, converting wet biomass into solid hydrochar, bio-liquid, and bio-gas. Since bio-liquid contains various compounds, it requires efficient sampling method to extract the target compounds from bio-liquid. In this research, fatty acid methyl ester (FAME) in bio-liquid was extracted based on hollow fiber supported liquid phase microextraction (HF-LPME) and determined by Gas Chromatography-Flame Ionization Detector (GC-FID) and Gas Chromatography/Mass Spectrometry (GC/MS). The well-known major components of biodiesel, including methyl myristate, palmitate, methyl palmitoleate, methyl stearate, methyl oleate, and methyl linoleate had been selected as standard materials for FAME analysis using HF-LPME. Physicochemical properties of bio-liquid was measured that the acidity was 3.30 (${\pm}0.01$) and the moisture content was 100.84 (${\pm}3.02$)%. The optimization of HF-LPME method had been investigated by varying the experimental parameters such as extraction solvent, extraction time, stirring speed, and the length of HF at the fixed concentration of NaCl salt. As a result, optimal conditions of HF-LPME for FAMEs were; n-octanol for extraction solvent, 30 min for extraction time, 1200 rpm for stirring speed, 20 mm for the HF length, and 0.5 w/v% for the concentration of NaCl. Validation of HF-LPME was performed with limit of detection (LOD), limit of quantitation (LOQ), dynamic range, reproducibility, and recovery. The results obtained from this study indicated that HF-LPME was suitable for the preconcentration method and the quantitative analysis to characterize FAMEs in bio-liquid generated from food waste via HTC reaction.

Analysis of DA-6034, a New Flavonoid Derivative in Biological Fluids by HPLC (HPLC를 이용한 생체 시료중의 새로운 플라보노이드 유도체인 DA-6034의 분석)

  • Lee, Jong-Jin;Son, Mi-Won;Yoo, Moo-Hi;Jang, Min-Sun;Kim, Won-Bae;Lee, Kang-Chun
    • YAKHAK HOEJI
    • /
    • v.42 no.2
    • /
    • pp.149-152
    • /
    • 1998
  • A high performance liquid chromatographic method was developed for the determination of DA-6034 in biological fluids using internal standard. Plasma containing DA-6034 and inter nal standard was extracted by liquid-liquid extraction at an acidic pH. After evaporation of the organic layer, the drug and internal standard were reconstituted with mobile phase and injected into the column. They were separated by high performance liquid chromatography on inertsil ODS II column at 334 nm. The detection limit of DA-6034 in plasma was 0.02 ${\mu}$g/ml. In this method, the range of recovery and coefficients of variation were 96-110% and 0.40-3.78%, respectively. There was no interference from endogenous substances. Urine and bile were analysed using the deproteinization method and the detection limit of DA-6034 was 1${\mu}$g/l.

  • PDF

Validations of Analysis Methods for Decursin and Decursinol Angelate of Angelicae gigantis Radix by Reversed-Phase Liquid Chromatography

  • Lee, Jong-Pill;Chang, Seung-Yeup;Park, Sang-Yong
    • Natural Product Sciences
    • /
    • v.10 no.6
    • /
    • pp.262-267
    • /
    • 2004
  • A reversed-phase liquid chromatographic method for decursin and decursinol angelate of Angelicae gigantis Radix, an important crude drug in Korean traditional medicine, was developed and validated. Decursin and decursinol angelate, the structure isomer (pyranocoumarin) each other, are the main organic constituents in Angelicae gigantis Radix. This method was developed using a RP-18 column, UV detector at 280 nm and 50% acetonitrile solution containing 0.01 M sodium dodecyl sulfate and 25 mM sodium dihydrogen phosphate (pH 5.0) as the mobile phase. Various validation parameters were included and evaluated satisfactorily. Linearity was established in range 2-75 mg/ml of decursin and decursinol angelate (correlation coefficient = 0.9997 and 0.9995, respectively). This analytical method showed good accuracy (98.1% and 99.5%, respectively). Precision (repeatability) revealed a relative standard deviation value of 1.71% (decursin) and 3.19% (decursinol angelate). For intermediate precision measure the considered variables were equipment and days. A robustness test showing the influence of deferent counter-ion concentration in mobile phase was also performed.

Analysis of Residual Solvents in Food Packaging Materials Using Solid Phase Microextraction Method (Solid Phase Microextraction법을 이용한 식품포장재 중의 잔류용제 분석)

  • 서택교;박상현;이윤수;김정한;권익부
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Solid phase microextraction (SPME) was used for the determination of 6 standard solvents (methanol, isopropanol, methyl ethyl ketone, ethyl acetate, cyclohexane, toluene) in food packaging materials. SPME method is a solvent-free sample preparation technique in which a fused silica fiber coated with polymeric organic liquid is introduced into the headspace above the sample. SPME method using fiber coated polydimethylisiloxane (PDMS) was compared with static headspace (SHS) method used as a reference. It was found that the optimal adsorption condition using PDMS-SPME method was 2$0^{\circ}C$ for 15 minutes for the standard solvents. Detection limits, linearity, reproducibility and recovery of both SHS and PDMS-SPME methods have been determined using 6 standard solvents. Both methods were characterized by high reproducibility and good linearity. Using SHS methods, the mean recovery of the 6 standard solvents was ranged from 75.5% to 105.8% with a mean relative standard deviation (RSD) of 0.3% to 4.8%. With PDMS-SPME method, the mean recovery of the 6 standard solvents was ranged from 86.7% to 108.3% with a mean RSD of 0.4% to 2.5%. The detection limits of both methods were the same for toluene, cyclohexane and methyl ethyl ketone; those of PDMS-SPME method were higher than those of SHS method for methanol, isopropanol and ethyl acetate. PDMS-SPME fiber shoed excellent adsorption for non-polar solvents such as toluene, while it showed relatively low adsorption for polar solvents such as methanol.

  • PDF

A Study on the Research of Analytical Method for 1,4-Dioxane in Water (1,4-Dioxane의 분석방법 연구)

  • Park, Sun-Ku;Kim, Tae-Ho;Rim, Yeon-taek;Myung, Nho-Il
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.549-563
    • /
    • 2005
  • The study was carried out to develop and standardize the analytical method of 1,4-dioxane in water. The National Institute of Environmental Research in Korea has monitored for 1,4-dioxane in water since 1998 and it has been detected in environmental water occasionally. But the environmental pollution and analytical method in water is not well known over the world. The trace analytical method at low-${\mu}/L$ level is prerequisite in order to evaluate the residue of 1,4-dioxane in water. Evaluation of the method was demonstrated by comparing and analyzing with liquid-liquid extraction, solid-phase extraction and purge & trap technique. As a result of experiment by standard solutions and raw samples, the precision and accuracy for three methods were obtained within error rate of about 10%. Therefore, three methods were standardized as official monitoring method in Korea. Also, a convenient and simple liquid-liquid extraction method for the analysis of 1,4-dioxane in water was developed by combined with gas chromatography/mass spectrometry and applied to the water samples in Korea

DEVELOPMENT ON ENHANCED LEAKED FUEL RECIRCULATION DEVICE OF LPLi ENGINE TO SATISFY SULEV STANDARD

  • Myung, C.L.;Kwak, H.;Park, S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.4
    • /
    • pp.407-413
    • /
    • 2006
  • The liquefied petroleum gas(LPG), mixture of propane and butane, has the potential to reduce toxic hydrocarbon emissions and inhibit ozone formation due to its chemical composition. Conventional mixer systems, however, have problems in meeting the future lower emission standards because of the difficulty in controlling air-fuel ratio precisely according to mileage tar accumulation. Liquid Phase LPG injection(LPLi) system has several advantages in more precise fuel metering and higher engine performance than those of the conventional mixer type. On the other hands, leakage problem of LPLi system at the injector tip is a main obstacle for meeting more stringent future emission regulations because these phenomena might cause excessive amount of THC emission during cold and hot restart phase. The main focus of this paper is the development of a leaked fuel recirculation system, which can eliminate the leaked fuel at the intake system with the activated carbon canister. Leaked fuel level was evaluated by using a fast response THC analyzer and gas chromatography. The result shows that THC concentration during cold and hot restart stage decreases by over 60%, and recirculation system is an effective method to meet the SULEV standard of the LPLi engine.

Elution Behavior of Pd(II) - Isonitrosoethylacetoacetate Imine Chelates by Reversed Phase High Performance liquid Chromatography (역상 액체 크로마토그래피에 의한 Pd(II) - Isonitrosoethylacetoacetate Imine 유도체 킬레이트들의 용리 거동)

  • Kim, In-Whan;Shin, Han-Chul;Lee, Man-Ho;Yoon, Tai-Kun;Kang, Chang-Hee;Lee, Won
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.389-399
    • /
    • 1992
  • Liquid Chromatographic behavior of Pd(II) in Isonitrosoethylacetoacetate lmine, $Pd(IEAA-NR)_2$ (R=H, $CH_3$, $C_2H_5$, $n-C_3H_7$, $C_6H_5-CH_2$, $n-C_4H_9$) chelates were investigated by reversed-phase HPLC on Micropak MCH-5 column using methanol/water as mobile phase. The optimum conditions for the separation of $Pd(IEAA-NR)_2$ chelates were examined with respect to the effect of the flow rate, sample solvent, mobile phase strength and column temperature. It wass found that metal chelates were properly eluted in an acceptable range of capacity factor value($0{\leq}log\;k^{\prime}{\leq}1$). The dependence of the logarithm of capacity factor(k') on the volume fraction of water in the binary mobile phase was examined. Also, the dependence of k' on the liquid-liquid extration distribution ratio($D_c$) in methanol-water/n-alkane extration system was investigated. Both kinds of dependence are linear, which susggests that the retention of the electroneutral metal chelate is largely due to the solvophobic effect. Standard adsorption enthalpy changes (${\Delta}H^{\circ}$) and standard adsorption entropy changes (${\Delta}S^{\circ}$) of Pd(II) Isonitrosoethylacetoacetate imine chelates on Micropak MCH-5 column were calculated by measuring capacity factor with changing temperature of the column.

  • PDF

Determination of Aloesin in Plasma by High-Performance Liquid Chromatography as Fluorescent 9-Anthroyl Derivative

  • Kim, Kyeong-Ho;Lee, Jin-Gyun;Park, Jeong-Hill;Shin, Young-Geun;Lee, Seung-Ki;Cho, Tae-Hyung
    • Archives of Pharmacal Research
    • /
    • v.21 no.6
    • /
    • pp.651-656
    • /
    • 1998
  • A sensitive high-performance liquid chromatographic (HPLC) method for the determination of aloesin in plasma was developed. After solid-phase extraction from plasma and derivatization of aloesin and compound AD-1, which was prepared from aloesin as a internal standard, with 9-anthroylnitrile in the presence of quinuclidine, the derivatives were separated on a Inertsil ODS-3 column using acetonitrile/methanol/water (3:1:6) as a mobile phase, and detected fluorimetrically at 460nm with excitation at 360nm. The detection limit of aloesin was 3.2ng/ml in plasma (S/N=3).

  • PDF