• Title/Summary/Keyword: liquid-phase standard

Search Result 297, Processing Time 0.053 seconds

Sensitive Determination of Pinaverium Bromide in Human Plasma by LC-ESI-MS/MS : Applicability to Oral Bioavailability Determination (LC-ESI-MS/MS를 이용한 생체시료 중 브롬화피나베리움의 고감도 분석 및 이를 이용한 생체이용률 평가)

  • Park, Seok;Lee, Ye-Rie;Kim, Ho-Hyun;Lee, Hee-Joo;Kim, Yoon-Gyoon;Youm, Jeong-Rok;Han, Sang-Beom
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.6
    • /
    • pp.513-519
    • /
    • 2004
  • A sensitive method for quantification of pinaverium bromide in human plasma was established using liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS/MS). Glimepiride was used as internal standard. Pinaverium bromide and internal standard in plasma sample were extracted using tert-butylmethylether(TBME). A centrifuged upper layer was then evaporated and reconstituted with mobile phase of acetonitrile-5 mM ammonium formate (80/20, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS with multiple reaction monitoring (MRM) mode, pinaverium and glimepirde were detected without severe interference from human plasma matrix. Pinaverium produced a protonated precursor ion $([M+H]^+)$ at m/z 510.3 and a corresponding product ion at m/z 228.9. Internal standard produced a protonated precursor ion $([M+H]^+)$ at m/z 491.5 and a corresponding product ion at m/z 352.0. Detection of pinaverium bromide in human plasma was accurate and precise, with limit of quantitation at 0.5 ng/ml. The method has been successfully applied to bioavailability study of pinaverium bromide tablet in Korean healthy male volunteers. Pharmacokinetic parameters such as $AUC_t,\;C_{max},\;T_{max},\;K_{el}\;and\;t_{1/2}$ were calculated.

Simultaneous Characterization of Sofalcone and Its Metabolite in Human Plasma by Liquid Chromatography -Tandem Mass Spectrometry

  • Han, Sang-Beom;Jang, Moon-Sun;Lee, Hee-Joo;Lee, Ye-Rie;Yu, Chong-Woo;Lee, Kyung-Ryul;Kim, Ho-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.729-734
    • /
    • 2005
  • A sensitive and selective method for quantitation of sofalcone and its active metabolite in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Plasma samples were transferred into 96-well plate using an automated sample handling system and spiked with 10 $\mu$L of 2 $\mu$g/mL $d_3$-sofalcone and $d_3$-sofalcone metabolite solutions (internal standard), respectively. After adding 0.5 mL of acetonitrile to the 96-well plate, the plasma samples were then vortexed for 30 sec. After centrifugation, the supernatant was transferred into another 96-well plate and completely evaporated at 40 ${^{\circ}C}$ under a stream of nitrogen. Dry residues were reconstituted with mobile phase and were injected into a $C_{18}$ reversed-phase column. The limit of quantitation of sofalcone and its metabolite was 2 ng/mL, using a sample volume of 0.2 mL for analysis. The reproducibility of the method was evaluated by analyzing 10 replicates over the concentration range of 2 ng/mL to 1000 ng/mL. The validation experiments of the method have shown that the assay has good precision and accuracy. Sofalcone and its metabolite produced a protonated precursor ion ([M+H]$^+$) of m/z 451 and 453, and a corresponding product ion of m/z 315 and 317, respectively. Internal standard ($d_3$-sofalcone and $d_3$-sofalcone metabolite) produced a protonated precursor ion ([M+H]$^+$) of m/z 454 and 456 and a corresponding product ion of m/z 315 and 317, respectively. The method has been successfully applied to a pharmacokinetic study of sofalcone and its active metabolite in human plasma.

Detection of Undeclared Betamethasone Derivatives in Cosmetic Products Labeled to Contain Zinc Pyrithione as the Active Ingredient (아연피리치온을 유효성분으로 표기한 화장품류에서 미표기 성분인 베타메타손 유도체의 검출)

  • Lee, Jeong-Pyo;Park, Sung-Hwan;Yang, Seong-Jun;Kim, Sun-Mi;Son, Kyung-Hun;Yun, Mi-Ok;Choi, Sang-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.1
    • /
    • pp.11-17
    • /
    • 2009
  • Betamethasone propionate, an anti-inflammatory glucocorticosteroid, was detected in cosmetics with no indication on the label of this compound as an ingredient. The product was formulated as a topical spray or shampoo and labeled to contain zinc pyrithione as the active ingredient. A thin-layer chromatographic analysis was carried out on silica gel plates to provide a first indication about the presence of a compound with steroid structure and reactivity; then high-performance liquid chromatography (HPLC) separation allowed the identification of the corticosteroid agent and its quantification. To identify the corticosteroid agent from these commercial samples we collected the fractions suspected to have ketol steroids by prep HPLC and identified the compound as betamethasone propionate by NMR and MS spectrometry. Then we synthesized the standard for the betamethasone 17-propionate and 21-propionate and quantitate the corticosteroids from the sample by HPLC with that standards. By this method we identified the corticosteroid compounds from some commercial cosmetics such as zinc pyrithione sprays. The finding of betamethasone propionate in the products was shown by comparison to an authenticated standard of betamethasone propionate by retention time on reverse-phase HPLC. Two of the tested products contained betamethasone propionate at the levels of 0.005 ${\sim}$ 0.02% and the others were free of betamethasone propionate.

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Analysis of Multiple Pesticide Residues in Apples and Pears Using Gas-Liquid Chromatography (Gas-Liquid Chromatography를 이용한 사과 및 배 중의 농약 다성분 잔류분석법)

  • Park, Ju-Hwang;Kim, Taek-Kyum;Oh, Chang-Hwan;Kim, Jeong-Han;Lee, Young-Deuk;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.3
    • /
    • pp.148-157
    • /
    • 2004
  • A rapid analytical method was developed to determine multiple pesticide residues in apples and pears using gas-liquid chromatography (GLC). The samples were extracted with water-miscible solvents and purified by cleanup procedures serially comprising liquid-liquid partition and solid-phase extraction (SPE). Each analyte was separated and determined by a high-resolution GLC equipped with electron-capture detector (ECD) and nitrogen-phosphorous detector (NPD). A total of 196 pesticides, which were previously classified into 5 groups each for ECD and NPD based on their retention behaviors on the capillary column and responses to the detector, were subjected to the recovery experiment. In compliance with the analytical criteria, 70 to 120% of recovery and less than 20% relative standard deviation the proposed method could be successfully applied to analyze 136 and 133 pesticide residues in apples and pears, respectively, which enabled not only rapid screening but quantitation of the residues. Even though less reliability was resulted from unacceptable recovery range, rest of pesticides including 43 and 45 analyzes in apples and pears, could be also detected for their identity. The proposed method fliled to cover 17 and 18 pesticides for apples and pears, which mostly showed high polarity or heat-lability but could be suitable far fast surveilance or monitoring of fruit harvests.

Simultaneous Determination of Amitraz, Bromopropylate, Coumaphos, Cymiazole and 2,4-Dimethylaniline in Korean Honey Samples by High-Performance Liquid Chromatography

  • Ryoo, Jae-Jeong;Kim, Se-Hoon;Jeong, Young-Han;Do, Hwan-Suk;Ryu, Jeong-Eun;Kwon, Hae-Young;Jeong, Ji-Yoon;Park, Hye-Jin;Lee, Soon-Ho;Hong, Moo-Ki;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.1043-1047
    • /
    • 2008
  • Simultaneous determination of amitraz, bromopropylate, coumaphos, cymiazole and 2,4-dimethylaniline in 200 honey samples purchased in Korea was performed by reversed-phase high-performance liquid chromatography with multiple UV detection. 2% Acetone in hexane was used for a liquid-liquid extraction and 20-40% water in acetonitrile solutions were used as mobile phases. The LOD for the analytes varied between 0.4 and 1.5 $\mu$g/L and the recoveries were yielded between 64 and 94%. Relative standard deviation of the repeatability of the method is less than 15%. Amitraz was not present in amount above 10 $\mu$ g/L and one for coumaphos and cymiazole and two for bromopropylate, and three for 2,4-dimethylanilne were detected in amount above 10 $\mu$ g/ L. Levels of the acaricide residues found were less than 50 $\mu$ g/L.

Comparison between the liquid-liquid partition method and modified QuEChERS method for the analysis of pesticide residues in beef fat (소지방 중 잔류농약분석을 위한 액-액분배법과 modified QuEChERS법 비교)

  • Kim, Yoen-Joo;Choi, Yoon-Hwa;Shin, Bang-Woo;Lee, Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.4
    • /
    • pp.429-439
    • /
    • 2011
  • This article described the comparison of a quick, easy, cheap, effective, rugged and safe (QuEChERS) sample preparation and the classical method established by National Veterinary Research and Quarantine Service (NVRQS) for the determination of pesticide residues in livestock products using GC-tandem mass spectrometry. The classical method by NVRQS used liquid-liquid partioning followed by evaporizing. The modified QuEChERS entailed extraction of 2 g sample with 15 ml acetonitrile containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 6 ml of the extract underwent a cleanup step (in a technique known as column-based solid phase extraction) using 400 mg each of $C_{18}$ and primary secondary amine sorbents plus 1,200 mg magnesium sulfate. The quantitation of individual pesticides by both methods was based on tissue standard calibration curves with a correlation coefficient in excess of 0.98 for the 24 pesticides. The detection limits by the classical method were ranged 1.3~5.0 ${\mu}g$/kg, with mean recoveries between 76.2% and 114.3% except aldrin (59.3%) and deltamethrin (63.6%). The detection limits by modified QuEChERS were ranged 0.3~6.2 ${\mu}g$/kg, with mean recoveries between 68.0% and 114.3% except dimethipin (152.6%), chlorfenvinphos (138.1%), 4,4-DDT (61.5%), aldrin (60.4%) and chinomethionate (30.3%).

A Simple and Sensitive Assay for Cefepime in Human Plasma Using High Performance Liquid Chromatography

  • Kim, Young-Sun;Yim, Dong-Seok;Lee, Dong-Gun;Lee, Sang-Bok
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.4
    • /
    • pp.247-250
    • /
    • 2003
  • A simple and sensitive assay method was developed for cefepime in human plasma using high performance liquid chromatography (HPLC). Cefepime and cefadroxil (the internal standard) were extracted from heparinized human plasma by simple deproteination with perchloric acid. The extract was injected into an Atlantis dC18 column ($250{\times}4.6$ mm; particle size $5{\mu}m$, Waters) and the column was eluted with methanol and 0.01 M dihydrogen phosphate at pH 3.0 (15:85 v:v) as a mobile phase at a flow rate of 0.7 mL/min. Linearity was confirmed for the range 0.25 to $200{\mu}L/mL$ and the limit of quantitation was $0.25{\mu}L/mL$. The retention times were 10.2 min and 13.4 min for cefepime and cefadroxil, respectively. This method was successfully applied to a pharmacokinetic study of cefepime in plasma from bone marrow transplant patients.

Characteristics of (Ba,Sr)RuO$_3$Bottom Electrodes by Liquid Delivery Metalorganic Chemical Vapor Deposition (액체 운반 유기 금속 화학 기상 증착법에 의한 $(Ba,Sr)RuO_3$ 하부전극의 특성)

  • Choe, Eun-Seok;Yun, Sun-Gil
    • Korean Journal of Materials Research
    • /
    • v.11 no.11
    • /
    • pp.997-1000
    • /
    • 2001
  • Conducting perovskite oxide, $(Ba,Sr)RuO_3(BSR)$, which has many advantages for $(Ba,Sr)TiO_3(BST)$ due to their similarity in crystal structure, lattice constant and chemical composition, was prepared on n-type Si (100) by liquid delivery metalorganic chemical vapor deposition(LDMOCVD). The deposition characteristics of BSR were controlled by gas-phase mass-transfer in the experiment. The BSR films deposited at 50$0^{\circ}C$ and oxygen flow rate of 100 sccm(standard cc/min) showed an average roughness of 22 $\AA$and resistivity of 810 $\mu$$\Omega$-cm. The roughness of BSR films with oxygen flow rate showed a close relationship with the resistivity of films. BSR (110) peak shifted toward lower Bragg angle with increase of x in the$(Ba_x,Sr_{1-x})TiO_3$. The resistivity of BSR films increased from 810 to 924 $\mu$$\Omega$-cm with increase of Ba content(x).

  • PDF

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.