• 제목/요약/키워드: liquid storage tank

검색결과 210건 처리시간 0.024초

유체-구조물-지반 상호작용을 고려한 유체저장탱크의 3차원 지진해석 (three dimensional seismic analysis of liquid storage tanks considering liquid-structure-soil interaction)

  • 김문겸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.99-106
    • /
    • 1999
  • In this study a base-isolated liquid storage tank subjected to seismic ground motion is numerically simulated on frequency , domain considering three-dimensional liquid-structure-soil interaction. A hybrid formulation which combines the versatility of finite elements for tank structure and the efficiency of boundary elements for liquid and soil region is adopted for efficient modeling. The base-isolation system using the effective stiffness and damping ratio is also included in this formulation. in order to demonstrate the accuracy and validity of the developed solution the numerical results were compared with the reference solutions in each interaction problem. The effects of the liquid filling ratio and the stiffness of base-isolation system on the behavior of the liquid storage tanks are analyzed.

  • PDF

LNG 지하 저장탱크 벽체의 비선형 열응력 해석 (Nonlinear Thermal Stress Analysis of In-ground LNG Storage Tank)

  • 곽효경;송종영;이광모
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.111-118
    • /
    • 2000
  • Concrete cracking due to the temperature gradient across the wall, caused by the difference in temperature between cryogenic liquid natural gas stored and surrounding environment of in-ground LNG storage tank, is investigated in this study. Crack propagation of concrete LNG tank is effectively simulated by using a layered degenerated shell element. In addition, material nonlinearity is taken into consideration on the basis of the nonlinear elastic-orthotropic model. Finally, numerical analysis for a real LNG storage tank is conducted with the objective to verify the efficiency of the introduced model.

  • PDF

수학적 해석 방법에 의한 액체저장탱크의 액동압 거동 해석 (Hydrodynamic Behavior Analysis of Vertical-Cylindrical Liquid-Storge Tanks by Mathematically Analytic Method)

  • 박종률;오택열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.628-635
    • /
    • 2001
  • Hydrodynamic behavior and response of vertical-cylindrical liquid-storage tank is considered. The equation of the liquid motion is shown by Laplace's differential equation with the fluid velocity potential. The solution of the Laplace's differential equation of the liquid motion is expressed with the modified Bessel functions. Only rigid tank is studied. The effective masses and heights for the tank contents are presented for engineering design model.

  • PDF

Influence of uplift on liquid storage tanks during earthquakes

  • Ormeno, Miguel;Larkin, Tam;Chouw, Nawawi
    • Coupled systems mechanics
    • /
    • 제1권4호
    • /
    • pp.311-324
    • /
    • 2012
  • Previous investigations have demonstrated that strong earthquakes can cause severe damage or collapse to storage tanks. Theoretical studies by other researchers have shown that allowing the tank to uplift generally reduces the base shear and the base moment. This paper provides the necessary experimental confirmation of some of the numerical finding by other researchers. This paper reports on a series of experiments of a model tank containing water using a shake table. A comparison of the seismic behaviour of a fixed base system (tank with anchorage) and a system free to uplift (tank without anchorage) is considered. The six ground motions are scaled to the design spectrum provided by New Zealand Standard 1170.5 (2004) and a range of aspect ratios (height/radius) is considered. Measurements were made of the impulsive acceleration, the horizontal displacement of the top of the tank and uplift of the base plate. A preliminary comparison between the experimental results and the recommendations provided by the liquid storage tank design recommendations of the New Zealand Society for Earthquake Engineering is included. The measurement of anchorage forces required to avoid uplift under varying conditions will be discussed.

약품(액상소석회) 저장조 준설 작업자의 유해인자 특성 평가 사례 (Characteristics of Hazardous Factors Regarding Chemical(Liquid Lime) Storage Tank Dredging Workers)

  • 김제훈;김기연
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Objectives: The study was performed to investigate characteristics of hazardous factors regarding chemical(liquid lime) tank dredging workers by case survey. Methods: Field data such as working condition, MSDS and respirators applied to chemical tank dredging work were analyzed and the work environmental factors of noise and indoor air quality were measured to compare existing data with actual work situations. Results: No health hazards to workers due to working conditions were confirmed during dredging work inside the chemical storage tank. All air quality measurement data during dredging work satisfied the management standards, and there were no by-products. During dredging work, there was a significant change in noise depending on the type of work, but considering the noise reduction rate(NRR) of the earplugs worn by workers, there was no actual health hazard due to noise exposure. Conclusions: A fit test for respirator and the expiration date of the safety helmet should be observed to ensure an appropriate level of safety and health for dredging workers in the chemical storage tank.

Free vibration analysis of steel liquid storage tank with functionally graded column based on modified continuum mechanics

  • Cavus, Yakup Harun;Kupeli, Togay;Yayli, Mustafa Ozgur
    • Coupled systems mechanics
    • /
    • 제11권4호
    • /
    • pp.335-355
    • /
    • 2022
  • It's important to note that the number of studies on the lateral vibration of steel liquid storage tanks has been quite modest in the past. The aim of this research has to look at the variables that affect vibration of storage tanks and to highlight the characteristics of a construction that hasn't received much attention in the literature. The storage tank has pre-sized in the study, and aluminum and steel have chosen as components. The specified material qualities and the factors utilized in the investigation has used to calculate vibration frequency values. The resulting calculations are backed up by tables and graphs, and it's an important to look into the parameters that affect the vibration frequencies that will occur on the designed storage tank vary. In the literature, water tanks are usually modelled as lumped masses. The horizontal stiffness of the column on which it is placed is assumed to be constant throughout. This is an approximation method of solving this problem. The column is handled in this study with a more realistic approach that fits the continuum mechanics in the analysis. The reservoir part is incorporated directly into the problem as the boundary condition.

기초분리(基礎分離)된 액체저장(液體貯藏)탱크의 유사(類似) 동적실험(動的實驗) (Pseudo-Dynamic Tests on Base-Isolated Liquid Storage Tanks)

  • 김남식;이동근
    • 대한토목학회논문집
    • /
    • 제13권4호
    • /
    • pp.51-64
    • /
    • 1993
  • 본 연구에서는 원통형 액체저장탱크(cylindrical liquid storage tank)를 대상으로 적층(積層)고무받침(LRB)방식의 기초분리장치(base isolator)를 사용하였을 때의 진동감소효과를 분석하기 위하여 지진하중에 대한 유사동적실험(Pseudo-dynamic test)을 수행하였다. 유사동적실험을 효과적으로 수행하기 위하여 구조분할기법(substructuring technique)을 도입하여 액체저장탱크를 수치적으로 모형화하였으며 효율적인 수치적분방법을 실험알고리즘에 적용하였다.

  • PDF

Probabilistic analysis of seismically isolated elevated liquid storage tank using multi-phase friction bearing

  • Moeindarbari, Hesamaldin;Malekzadeh, Masoud;Taghikhany, Touraj
    • Earthquakes and Structures
    • /
    • 제6권1호
    • /
    • pp.111-125
    • /
    • 2014
  • Multiple level performance of seismically isolated elevated storage tank isolated with multi-phase friction pendulum bearing is investigated under totally 60 records developed for multiple level seismic hazard analysis (SLE, DBE and MCE). Mathematical formulations involving complex time history analysis have been proposed for analysis of typical storage tank by multi-phase friction pendulum bearing. Multi-phase friction pendulum bearing represent a new generation of adaptive friction isolation system to control super-structure demand in different hazard levels. This isolator incorporates four concave surfaces and three independent pendulum mechanisms. Pendulum stages can be set to address specific response criteria for moderate, severe and very severe events. The advantages of a Triple Pendulum Bearing for seismic isolation of elevated storage tanks are explored. To study seismic performance of isolated elevated storage tank with multi-phase friction pendulum, analytical simulations were performed with different friction coefficients, pendulum radii and slider displacement capacities.

지진계측데이타에 근거한 유체저장탱크의 동적응답 평가 (Evaluation of Dynamic Response for Liquid Storage Tank using the Observed Earthquake Data)

  • 허택영
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.115-127
    • /
    • 1997
  • A study to evaluate the seismic response of $\frac{1}{2}$-scaled liquid storage tank constructed in Hualien, is performed. And this study is to identify the liquid-structure-soil interaction by observed earthquake data ans analyzed results. After the calculation of soil impedance for the test site by SASSI code, 3-dimensional seismic response analysis is performed by BEM-FEM-Impedance Method with the consideration of liquid-structure-soil interaction when the tank is excited by real earthquake. The observed acceleration and hydrodynamic pressure are compared with the numerical results. This comparisons show good agreement in predominant frequency and maximum hydrodynamic pressure. And the free surface sloshing motion due to earthquake loadings is computed in time domain.

  • PDF

Liquid Based Solar Thermal Storage를 위한 열교환성능(熱交換性能)에 관한 연구(硏究) (A Study on the Heat Exchange Performance for the Liquid Based Solar Thermal Storage)

  • 김병철;정현채
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.35-45
    • /
    • 1985
  • A solar hot water storage tank was designed and constructed to examine the heat exchange performances on load side for the solar thermal storage in a single loop solar water heating system. In the tank helically coiled tube was immersed. The hot water was circulated from either top or bottom. The circulation flow rate was varied from 500 ml/min to 20,000 ml/min. The effect of flow rate was observed. The thermal performances according to the flow rate and flow direction were examined. The temperature distributions in the tank and inside of the tubes were plotted along the process of cooling.

  • PDF