• Title/Summary/Keyword: liquid mercury

Search Result 46, Processing Time 0.024 seconds

The optical characteristics study of sandwich structure based liquid crystal for the radiation detector application (방사선 검출기 적용을 위한 액정 기반 다층 구조의 광 특성 평가)

  • Shin, Jung-Wook;Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Yul;Kim, Jin-Young;Lee, Gun-Hwan;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.390-392
    • /
    • 2005
  • The digital radiation detectors are used clinically by diagnostic apparatus. However the digital radiation detector are some problem like high operating voltage, light blurring, low conversion efficiency, low fill factor, etc. Thus we propose a new radiation detector that the photoconductor layer and liquid crystal layer are coupled in sandwich structure. X-ray absorption in the photoconductor layer controls the state of the liquid crystal via creation of charge carrier and the light modulation of liquid crystal make image formation. The advantage of the new radiation detector is that high resolution image is acquired and the signal amplification is possible by external visible light source. In this study, we study the optical properties and electrical properties of the new radiation detector to irradiate X-ray. The Mercury Iodide($HgI_2$) was used by photoconductor material, and the aluminum is used by reflective layer. The thickness of Mercury Iodide is about $200{\mu}m$, the operating voltage of the liquid crystal is 1.5~5V. The electrical properties of Mercury Iodide was measured, and the transmission efficiency of liquid crystal was measured by modulation potential.

  • PDF

Scanning Backlight Driver for Mercury Free Flat Fluorescent Lamp (무수은 면광원 램프용 Scanning Backlight 구동회로)

  • Oh, Eun-Tae;Jung, Yong-Min;Lee, Kyung-In;Yoo, Ho-Won;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.8-14
    • /
    • 2009
  • A lamp which is currently employed to LCD(Liquid Crystal Display) Backlight is almost CCFL(Cold Cathod Fluorescent Lamp) and EEFL(External Electrode Fluorescent Lamp). However, the use of these lamps is being restricted as RoHS(the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment) regulation is gradually reinforced. According to this situation, the manufacturing of a lamp which doesn't use mercury is unescapable. Moreover, LCD TV has a defect which take place Motion Blur phenomenon due to response time of LC(Liquid Crystal), and Hold-type characteristic which only exists in LCD differently to CRT, PDP. In this paper, an inverter is proposed to drive a plane light source lamp which is not containing mercury. Driving circuit of proposed inverter is simple because the number of semiconductor device and magnetic device is reduced by using forward topology. Also, Motion Blur phenomenon is decreased by dividing the plane light source lamp to six block along vertical direction, and scanning. Finally, we proved usefulness of proposed inverter through experiment.

Preconcentration and Speciation of Trace Mercury Compounds in Water Sample Using Dithizonates Extraction and Reverse Phase Liquid Chromatography (디티존 착물 추출과 역상 액체 크로마토그래피를 이용한 물시료 중의 미량 수은 화합물의 농축 및 화학종의 분리)

  • Suh, Jung-Ki;Cho, Kyung-Haeng;Lee, Sang-Haak
    • Analytical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.81-88
    • /
    • 2000
  • A rapid preconcentration method was developed for the speciation of the trace mercury compounds in water sample. The mercury compounds were extracted and preconcentrated simply as their dithizone complexes by passing through the dithizone impregnated ultra-high molecular weight polyethylene (UHMWPE) membrane solvent inlet filter following sanification in methanol solvent. The concentrated dithizonates were separated by liquid chromatography on a $C_{18}$ column. Complete resolution was obtained between methyl-, ethyl-, phenyl-, and inorganic mercury with a mobile phase of 0.05 M acetate buffer (pH=4)/THF/methanol(3:5:2). The separnted mercury chelates were detected by spectrophotometrically at 475 nm. The proposed method was successfully applied to the speciation of mercury compounds in waste water with detection limit at the subnanogram/mL level.

  • PDF

A Simplified Phenomenological Theory of Viscosity for Liquid Metals

  • Kim, Won Su;Chae, Dong Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.1
    • /
    • pp.43-45
    • /
    • 2001
  • This study simplifies the phenomenological theory of viscosity previously proposed by the present authors. This simplified theory has only two thermodynamic properties and one parameter, as opposed to its predecessor, which has many, allowing for easy calculation of the liquid viscosities. The viscosity of liquid metals, an excellent test for checking the validity of the liquid theory, can be calculated using the equation based on the simplified theory. The calculated results by the current theory turn out to be good for the liquid metals, including sodium, potassium, rubbidium, cesium, lead and mercury.

A Study on the Droplet Formation of Liquid Metal in Water-Mercury System as a Surrogate of Molten Salt-Liquid Metal System at Room Temperature (용융염-액체금속 계의 대용물인 물-수은 계에서 액체금속 액적의 생성에 대한 연구)

  • Kim, Yong-il;Park, Byung Gi
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.165-172
    • /
    • 2018
  • As an approach for estimation of the droplet size in the molten salt-liquid metal extraction process, a droplet formation experiment at room temperature was conducted to evaluate the applicability of the Scheele-Meister model with water-mercury system as a surrogate that is similar to the molten salt-liquid metal system. In the experiment, droplets were formed through the nozzle and the droplet size was measured using a digital camera and image analysis software. As nozzles, commercially available needles with inner diameters (ID) of 0.018 cm and 0.025 cm and self-fabricated nozzles with 3-holes (ID: 0.0135 cm), 4-holes (ID: 0.0135 cm), and 2-holes (ID: 0.0148 cm) were used. The mercury penetration lengths in the nozzles were 1.3 cm for the needles and 0.5 cm for the self-fabricated nozzles. The droplets formed from each nozzle maintained stable spherical shape up to 20 cm below the nozzle. The droplet size measurements were within a 10% error range when compared to the Scheele-Meister model estimates. The experimental results show that the Scheele-Meister model for droplet size estimation can be applied to nozzles that stably form droplets in a water-mercury system.

Pulse Density Modulated ZVS High Frequency Inverter with Reverse Blocking Single Switch for Dielectric Barrier Discharge Lamp Dimming

  • Sugimura Hisayuki;Yasui Kenji;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.206-209
    • /
    • 2006
  • At present, the cold cathode fluorescent lamp (CCFL) using mercury lamp has been generally used far liquid crystal backlight source of personal computer and car navigation and so on. This kind of lamp is more excellent on luminance performance and cost. However, the requirements of liquid crystal backlight due to a light source without mercury have been strongly increased from a viewpoint of the actual influence on environmental preservation and environmental recycling. As fluorescent lamp without mercury, Dielectric Barrier Discharge based rare gas fluorescent lamp (DBD-FL) using xenon (Xe) gas has been studied so far. This DBD lamp has no influence on the human body and environmental recycle. Its operating life is long because electrode is out. In this paper, the simulation and experimental results of soft switching high frequency inverter with reverse blocking single switch as a high frequency power supply circuit for DBD-FL using Xe gas are comparatively evaluated and discussed from a practical point of view.

  • PDF

In Situ Monitoring of Biofilm Formations of Escherichia coli and Pseudomonas putida by Use of Lux and GFP Reporters

  • Khang, Youn-Ho;Rober S. Burlage
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.3 no.1
    • /
    • pp.6-10
    • /
    • 1998
  • A plasmid vector containing two reporter genes, mer-lux and lac-GFP, was transformed to both Escherichia coli and Pseudomonas putida. Their cellular activities and biofilm characteristics were investigated in flow-cell units by measuring bioluminescent lights and fluorescent levels of GFP. Bioluminescence was effective to monitor temporal cell activities, whereas fluorescent level of GFP was useful to indicate the overall cell activities during biofilm development. The light production rates of E. coli and P. putida cultures were dependent upon concentrations of HgCl2. Mercury molecules entrapped in P. putida biofilms were hardly washed out in comparison with those in E. coli biofilms, indicating that P. putida biofilms may have higher affinity to mercury molecules than E. coli biofilms. It was observed that P. putida expressed GFP cDNA in biofilms but not in liquid cultures. This may indicate that the genetic mechanisms of P. putida were favorably altered in biofilm conditions to make a foreign gene expression possible.

  • PDF

Decontamination of Mercury Contained in CCFLs (Cold Cathode Fluorescence Light) Disassembled from Waste LCDs (Liquid Crystal Display) (폐 LCD (Liquid Crystal Display) 해체 후 분리된 CCFL (Cold Cathode Fluorescence Light) 내 수은의 건식 제거 공정)

  • Park, Jae Layng;Lee, Sungkyu;Kang, Leeseung;Lee, Chan Gi;Cho, Sung-Su;Hong, Myung Hwan;Hong, Hyun Seon
    • Resources Recycling
    • /
    • v.23 no.2
    • /
    • pp.61-70
    • /
    • 2014
  • LCD televisions and monitors use cold cathode fluorescence lamps (CCFLs) to illuminate the screen. Most CCFLs contain mercury and they have to be carefully handled at the end of their lives as per minimum treatment standards under the Waste Electrical and Electronic Equipment (WEEE) and Restriction of Hazardous Substances (RoHS) directives. CCFLs were carefully separated from mold frames of waste LCD units for primary decontamination of mercury/fluorescent compound mixture using CCFL decontamination system designed and fabricated in the present research. Residual mercury was further removed by employing a pyro-process, where crushed CCFL tubes transferred from primary decontamination process were subject to heat treatment at $550^{\circ}C$ in a box furnace: more than 99% of mercury was removable from waste CCFLs.