• Title/Summary/Keyword: liquid liquid continuous extraction

Search Result 28, Processing Time 0.023 seconds

Comparison of Volatile Flavor Compounds in Commercial Crab-like Flavorants by Analyzing Methods (분석방법에 따른 시판 게향료의 휘발성 향기성분 비교)

  • Cha, Yong-Jun;Cho, Woo-Jin;Jeong, Eun-Jeong
    • Journal of Life Science
    • /
    • v.16 no.7 s.80
    • /
    • pp.1243-1249
    • /
    • 2006
  • Volatile flavor compounds in commercial crab-like flavorants were compared by mean of solid phase microextraction(SPME) and liquid continuous extraction (LLCE)/GC/MSD methods. A total of 86 volatile flavor compounds were detected. Of these, 71 were positively identified consisting mainly of sulfur-containing compounds (13), aldehydes (3), ketones (2), esters (26), alcohols (5), aromatic compounds (3), terpenes (8), acids (2) and miscellaneous compounds (9). SPME method was more effective than LLCE method in detection of volatile components in commercial crab-like flavorants. Eight S-, N-containing compounds such as dimethyl sulfide, dimethyl disulfide, dipropyl disulfide, 3-(methylthio)propyl acetate, 3-(methylthio) propanal, 3-(methylthio) propanol, 2-methyl-3-(methylthio) pyrazine and 2-methyl-5-(methylthio) pyrazine, 8 esters such as styrallyl acetate, ethyl acetate, isoamyl acetate, benzyl acetate, ethyl pentanoate, butyl pentanoate, isoamyl pentanoate and furfuryl acetate were considered as major components in crab-like flavorants.

A review on Separation Technologies for Lithium Recovery from Waste Solutions in Recycling Process of Waste Battery (폐배터리 재활용 공정 폐액 중 리튬 회수를 위한 분리 기술 고찰)

  • Song, Daesung;Kim, Eunkyu;Vu, Thang-Toan
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.473-477
    • /
    • 2022
  • In this study, candidate technologies for lithium recovery from the process waste liquid generated in the waste battery recycling process were reviewed, and technologies applicable to the process from the commercialization point of view were reviewed from a qualitative point of view. The evaporation method is difficult to apply because it requires a large-scale land and shows a low recovery rate due to the loss of Li during the concentration process. In the case of precipitation, a commercially available technology shows a high recovery rate due to the high Li/Na selectivity of phosphoric acid, but there are disadvantages in that the process is complicated due to the use of expensive phosphoric acid, requiring a recovery step, and continuous operation is impossible because solids are handled in the Li concentration process. In the case of solvent extraction, if we find an inexpensive extractant with high Li/Na selectivity, continuous operation is possible with the method used in extraction of other metals in the previous step, and when Li is concentrated, continuous operation is possible because it is in a liquid state. If it shows a similar recovery rate compared to precipitation technology, commercialization will be the most likely.

Identification of Irradiation-induced Volatile Flavor Compounds in Irradiated Pork Meats (방사선 조사 돼지고기에서 휘발성 조사물질의 구명)

  • Cha, Yong-Jun;Kim, Hun;Cho, Woo-Jin;Jung, Yeon-Jung;Byun, Myung-Woo;Yoo, Young-Jae
    • Journal of Life Science
    • /
    • v.11 no.1
    • /
    • pp.35-42
    • /
    • 2001
  • Irradiation-induced volatile flavor compounds in irradiated (0, 1, 3, 5, 10 kGy) pork meats were analyzed by liquid liquid continuous extraction (LLCE) and gas chromatography/mass spectrometry (GC/MS) methods. One hundred nine volatile compounds were detected in irradiated pork meats. These compounds were mainly composed of hydrocarbons (42 compounds), aromatic compounds (39), aldehydes(9), ketones(5) and miscellaneous compounds (14). Among these, three volatile compounds, such as decene, 1,2,3,4,-tetrahydro-6-methylnaphthalene and 1,2,3,4-tetrahydro-dimethylnaphthalene were selected as irradiation-induced compounds comparing with irradiation dosages in irradiated pork meats. By the high correlation coefficient with the increment of irradiation dose, however, decene (r=0.93) was considered as marker compound for detecting irradiation dosage in fresh pork meats.

  • PDF

Identification of Character-impact Aroma Compounds and Comparisons of Sensory Attributes of Traditional Korean Medicinal Rice Wines Brewed with Functional Herbal Powders or Extracts

  • Lee, Gyu-Hee;Shin, Young;Chang, Yeong-Il;Jeong, Jae-Hong;Chang, Kyu-Seob;O, Man-Jin
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.4
    • /
    • pp.405-410
    • /
    • 2002
  • Rice wine was prepared with medicinal plants or plant extracts to obtain a value added nutritious alcoholic tonics. Powders of ten medicinal plants (PTM) or aqueous extracts prepared from them (ATM) were added during the initial stage of fermentation. Aroma compounds of rice wine (control) and wines containing PTM or ATM were isolated by liquid-liquid continuous solvent extraction (LLCSE) and analyzed by gas chromatography-olfactometry and aroma extract dilution analysis (AEDA). Desirable aroma compounds: acetaldehyde (sweet, ethereal), benzaldehyde (sweet, fragrant), ethyl acetate (sweet) and ethyl octanoate (sweet, ethanolic) had the highest log$_3$-flavor dilution (FD) factors in ATM. Results of sensory evaluation demonstrated that intensities of undesirable aroma attributes, such as koji and yeasty notes in control, and raw medicinal herb notes in PTM, were lowest in wine with ATM. Wines made with ATM had the most attractive aroma attributes among the three different traditional Korean medicinal wines.

Development of an Automatic PCR System Combined with Magnetic Bead-based Viral RNA Concentration and Extraction

  • MinJi Choi;Won Chang Cho;Seung Wook Chung;Daehong Kim;Il-Hoon Cho
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.363-370
    • /
    • 2023
  • Human respiratory viral infections such as COVID-19 are highly contagious, so continuous management of airborne viruses is essential. In particular, indoor air monitoring is necessary because the risk of infection increases in poorly ventilated indoors. However, the current method of detecting airborne viruses requires a lot of time from sample collection to confirmation of results. In this study, we proposed a system that can monitor airborne viruses in real time to solve the deficiency of the present method. Air samples were collected in liquid form through a bio sampler, in which case the virus is present in low concentrations. To detect viruses from low-concentration samples, viral RNA was concentrated and extracted using silica-magnetic beads. RNA binds to silica under certain conditions, and by repeating this binding reaction, bulk samples collected from the air can be concentrated. After concentration and extraction, viral RNA is specifically detected through real-time qPCR (quantitative polymerase chain reaction). In addition, based on liquid handling technology, we have developed an automatic machine that automatically performs the entire testing process and can be easily used even by non-experts. To evaluate the system, we performed air sample collection and automated testing using bacteriophage MS2 as a model virus. As a result, the air-collected samples concentrated by 45 times then initial volume, and the detection sensitivity of PCR also confirmed a corresponding improvement.

Comparison of Liquefying Efficiency of Mixed Organic Fertilizer as Affected by Aeration Time and the Ratio of Organic Fertilizer to Water (폭기시간과 유기질비료 농도에 따른 혼합유기질비료의 액비화 특성비교)

  • Lee, Jong-Tae;Ha, In-Jong;Moon, Jin-Seong;Song, Won-Doo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.2
    • /
    • pp.156-163
    • /
    • 2007
  • This study was conducted to evaluate the liquefying efficiency of mixed organic fertilizer in different conditions. The organic fertilizer was composed of sesame oil cake, rice bran, fish meal, ground bone meal etc, and made by fermenting process. It included $23g\;kg^{-1}$, $17.0g\;kg^{-1}$, $23.9g\;kg^{-1}$, $290g\;kg^{-1}$ of N, $P_2O_5$, $K_2O$, organic matter, respectively. In one test, the mixed organic fertilizer was added in the proportion of 10% to water 90% and aerated continuously, for 2, 8 hours per day, and not aerated as control. In the other test, ratios of organic fertilizer to water were 5%, 10%, 20% and aerated for 2 hours a day. With the increase of liquefying time, pH, EC and $NH_4-N$ increased without relation to aeration time. After 10 days, liquid organic fertilizer aerated for 2 hours a day contained $634mg\;N\;kg^{-1}$, $68.1mg\;P_2O_5\;kg^{-1}$, $453mg\;K_2O\;kg^{-1}$, which was not significantly different from 8 hours a day or continuous aeration. Then extraction ratios of inorganic contents were 27.6%, 4.0% and 18.9%, respectively. Continuous aeration resulted in increasing the viable number of aerobic bacteria, spore forming bacteria and fungi in liquefied solution. Higher ratio of organic fertilizer to water increased EC, $NH_4-N$ and other inorganic matter contents, but decreased extraction ratio of nutrients in liquid fertilizer. The liquid organic fertilizer of 20% contained $1,140mg\;N\;kg^{-1}$, $35.4mg\;P_2O_5\;kg^{-1}$, $544mg\;K_2O\;kg^{-1}$ after 10 days. Then extraction ratios were 24.8%, 2.4% and 13.6%, respectively. The ratio of organic fertilizer to water was positively correlated with only spore forming bacteria, Pseudomonas spp. among microorganisms.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Separation of Hydrocarbon Mixture Using (O/W)/O Emulsion Liquid Membrane ((O/W)/O 에멀젼형 액막을 이용한 탄화수소 혼합물의 분리)

  • Jeong, M.C.;Park, H.Y.;Oh, J.T.;Kim, J.K.;Shin, M.H.;Kim, W.S.
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.763-770
    • /
    • 1997
  • The separation of benzene-cyclohexane mixture using (O/W)/O emulsion liquid membrane was studied. The operating parameters which can affect the selectivity, benzene yield, and emulsion size distribution were examined and determined by the batch type operation. The unsteady state and steady state extraction behavior in continuous pulse stirred reactor(CPSR) were verified. The optimum conditions for benzene selectivity and yield in batch operation were as follows; emulsion mixing intensity 4000 rpm, Tween 80 concentration 0.4%, volume ratio of membrane phase to internal phase 0.75, volume ratio of dispersed phase to continuous phase 0.5, and permeation time 10 minutes, As impeller speed increased and the microdrop holdup decreased, the Sauter mean diameter decreased. Turbulence damping parameter of modified Calabrease correlation considering microdrop holdup was 2.28. The optimum conditions of continuous operation were as follows; agitation speed 300 rpm, pulse frequence 2 times/sec, flow rate of continuous phase 30ml/min, and flow rate of emulsion phase 12.0ml/min.

  • PDF

Aroma Characteristics of Acai Berry (아사이베리의 향기성분 특성 연구)

  • Lim, Seung-Hee;Nam, Heesop;Baek, Hyung-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.122-127
    • /
    • 2016
  • The objective of this study was to identify the volatile compounds and aroma-active compounds from acai berry (Euterpe oleracea). Volatiles were isolated by high vacuum distillation using solvent-assisted flavor evaporation (SAFE) and liquid-liquid continuous extraction (LLCE). To identify the characteristic aroma-active compounds of acai berry, gas chromatography-mass spectrometry-olfactometry was used. Aroma-active compounds were evaluated by aroma extract dilution analysis (AEDA). A total of 51 and 54 volatile compounds from acai berry were identified from SAFE and LLCE extracts, respectively. Alcohols were confirmed to be important volatile compounds in acai berry, as the major volatile compounds were 2-phenylethanol, (Z)-3-hexenol, and benzyl alcohol. ${\beta}-Damascenone$ (berry, rose), trans-linalool oxide (woody), (Z)-3-hexenol (grass), and 2-phenylethanol (rose, honey) were considered the aroma-active compounds in acai berry. The most intense aroma-active compound of acai berry was ${\beta}-damascenone$.

The Changes of Aroma in Wine Treated with Reverse Osmosis System (역삼투압 시스템으로 처리한 포도주의 향기성분 변화)

  • Lee, Seung-Ryong;Lee, Kyu-Hee;Chang, Kyu-Seob;Lee, Suk-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.17-24
    • /
    • 2000
  • Reverse osmosis (RO) system was applied to improve wine quality. General wine (GEN) and wines containing different sugar levels $24^{\circ}Brix$ (RO-24) and $24^{\circ}Brix$ (RO-28) by removing pure water using RO system without sugar addition on brewing method. And they were compared by wine aroma analysis. The preparing method of analysis was LLCE (liquid-liquid continuous extraction). And volatile aroma compounds of different wines were prepared for raw, and diluted materials in same proportion. The wine aromas were described by trained twelve panelists for QDA (quantitative descriptive analysis) and showed for FD (flavor dilution)-chromatogram. Consequently, overall acceptability of RO-28 showed better than that of other treatments. Aromas of RO-28 also were represented the high contents of positive aroma compounds such as ethanol and ethyl acetate, which were identified by GC-O and GC-MS.

  • PDF