• Title/Summary/Keyword: linear filter

Search Result 1,173, Processing Time 0.028 seconds

A New Method for Artifact Reduction Based on Capacitive Sensor and Adaptive Filter in Oscillometric Blood Pressure Measurement (오실로메트릭 혈압 측정에서 커패시턴스 센서와 적응필터를 이용한 새로운 잡음제거방법에 관한 연구)

  • Choi, Hyun-Seok;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.239-248
    • /
    • 2008
  • In this study, a new method using a capacitive sensor and an adaptive filter was proposed to deal with artifacts contaminating an oscillation signal in oscilometric blood pressure measurement. The proposed method makes use of a variation of the capacitance between an electrode fixed to a cuff and an external object to detect artifacts caused by the external object bumping into the cuff. The proposed method utilizes the adaptive filter based on linear prediction to remove the detected artifacts. The conventional method using linear interpolation and the proposed method using the adaptive filter were applied to three types of the artifact-contaminated oscillation signals(no overlap, non-consecutive overlap, and consecutive overlap between artifacts and oscillations) to compare them in terms of the artifact reduction performance. The proposed method was more robust than the conventional method in the case of consecutive overlap between artifacts and oscillations. The proposed method could be useful for measuring blood pressure in such a noisy environment that the subject is being transported.

Particle filter approach for extracting the non-linear aerodynamic damping of a cable-stayed bridge subjected to crosswind action

  • Aljaboobi Mohammed;Shi-Xiong Zheng;Al-Sebaeai Maged
    • Wind and Structures
    • /
    • v.38 no.2
    • /
    • pp.119-128
    • /
    • 2024
  • The aerodynamic damping is an essential factor that can considerably affect the dynamic response of the cable-stayed bridge induced by crosswind load. However, developing an accurate and efficient aerodynamic damping model is crucial for evaluating the crosswind load-induced response on cable-stayed bridges. Therefore, this study proposes a new method for identifying aerodynamic damping of the bridge structures under crosswind load using an extended Kalman filter (EKF) and the particle filter (PF) algorithm. The EKF algorithm is introduced to capture the aerodynamic damping ratio. PF technique is used to select the optimal spectral representation of the noise. The effectiveness and accuracy of the proposed solution were investigated through full-scale vibration measurement data of the crosswind-induced on the bridge's girder. The results show that the proposed solution can generate an efficient and robust estimation. The errors between the target and extracted values are around 0.01mm and 0.003^o, respectively, for the vertical and torsional motion. The relationship between the amplitude and the aerodynamic damping ratio is linear for small reduced wind velocity and nonlinear with the increasing value of the reduced wind velocity. Finally, the results show the influence of the level of noise.

An Adaptive Linear Channel Equalizer Using Asymmetric Transversal Filter (비대칭 필터 구조를 이용한 적응형 선형 채널 등화기)

  • Han, Jong-Young;Lim, Dong-Guk;Kim, Jae-Moung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9A
    • /
    • pp.830-837
    • /
    • 2005
  • ISI is caused by delay spread in the multipath channel environment. There are two kinds of channel equalizer: Linear and Non-Linear type according to the structures. In this paper, we propose an improved adaptive linear equalizer to mitigate ISI. The proposed adaptive equalizer is constructed by using asymmetrical Dsmvenu filter based on USE sub-optimal receiver. Asymmetrical structure of the transversal filter is realized by moving the main tap position from center to side. If this structure is used, we can divide ISI to precusor and postcusor. As a result the proposed equalizer has a larger extended compensation range than conventional adaptive linear equalizer. In computer simulation, we compare the bit error rate performance of the proposed linear equalizer with the conventional one on the S-V channel which is modeled for WB systems.

Fast Stream Cipher ASC16 (고속 스트림 암호 ASC16)

  • Kim, Gil-Ho;Song, Hong-Bok;Kim, Jong-Nam;Cho, Gyeong-Yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.437-440
    • /
    • 2009
  • We propose a fast stream cipher ASC16 for software implementation. ASC16 has a very simple structure with ASR(Arithmetic Shift Register), NLF(Non-Linear Filter), and NLB(Non-Linear Block), and is executed by a word. It is a stream cipher for wireless communication, which makes 32bit key streams using s-box with non-linear transformation. The processed result is almost same as SSC2, 32bit output stream cipher, developed by Zhang, Carroll, and Chan. The period is longer than SSC2, and it causes the difficulty of Correlation attack and raises security very much. The proposed ASC16 is efficiently used in the process of a fast cipher in the limited environment such as wireless communication.

  • PDF

Characteristic Analysis of Power Compensation Condenser Considering Voltage Harmonics (전압 고조파를 고려한 역률보상용 콘덴서의 특성 분석)

  • Kim, Jong-Gyeum;Lee, Dong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.141-145
    • /
    • 2010
  • Most of the industrial loads includes the non-linear load as well as the linear load because there are many kinds of power conversion equipments at the input stage of the load in distribution network. The non-linear load causes the distortion of voltage waveform at PCC because the non-linear load generates the harmonic current. As a result, various voltage harmonics are existed at PCC depending on the current harmonics from the non-linear load. And, a series reactor is generally connected to the power capacitor in series to attenuate the distortion of voltage waveform and to reduce an inrush current of power capacitor. Also, harmonic current of power capacitor is highly dependent on the series reactor because it is operated with the power capacitor as a passive filter against nonlinear loads. Then, these capacitors might be damaged by the excessive voltage and current harmonic components. In this paper, we presented how to select the capacitor and series reactor to meet the requirement of the voltage distortion at PCC and analyzed the voltage, current and capacity rating of the power capacitor by the computer simulation to ensure the safe operation of power capacitor when the voltage harmonics at PCC are existed. Also, the analysis data were compared with the experimental measurements for the verification.

A Multi-channel CMOS Low-voltage Filter with Newly Current-mode Integrator (새로운 전류모드 적분기를 갖는 다중 채널 CMOS 저전압 전류모드 필터 설계)

  • Lee, Woo-Choun;Bang, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3638-3644
    • /
    • 2009
  • A CMOS multi-channel low-voltage current mode filter circuit is designed. The designed current-mode filter is based on linear cascode current-mode integrator that is newly proposed in this paper. When it is compared with that of the typical current-mirror type current-mode integrator, the proposed linear cascode current-mode integrator achieves high current gain and unity gain frequency. The designed filter is composed with 5th Chebyshev function and converted to active version by signal flow graph method. We verified that the designed filter can be applied to three-channel basedband, bluetooth, DECT and WCDMA with 0.51MHz~7.03MHz frequency tuning range by Hspice simulation using 1.8V-$0.18{\mu}m$ CMOS technology.

[ $H_{\infty}$ ] Filtering for Descriptor Systems

  • Chen, Yue-Peng;Zhou, Zu-De;Zeng, Chun-Nian;Zhang, Qing-Ling
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.6
    • /
    • pp.697-704
    • /
    • 2006
  • The paper is concerned with $H_{\infty}$ filtering for descriptor systems. A necessary and sufficient condition is established in terms of linear matrix inequalities(LMIs) for the existence of normal filters such that the error systems are admissible and the transfer function from the disturbance to the filtering error output satisfies a prescribed $H_{\infty}$-norm bound constraint. When these LMIs are feasible, an explicit parameterization expression of all desired normal filter is given. All these results are yielded without decomposing the original descriptor systems, which makes the filter design procedure simple and direct. Finally, a numerical example is derived to demonstrate the applicability of the proposed approach.

Robust Mixed H2/H Filter Design for Uncertain Fuzzy Systems (불확실한 퍼지시스템의 견실한 혼합 H2/H 필터 설계)

  • Yoo, Seog-Hwan;Choi, Byung-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.5
    • /
    • pp.557-562
    • /
    • 2004
  • This paper deals with a robust mixed ${H_2}/{H_{\infty}}$ filter design problem for a nonlinear dynamic system modeled as a T-S fuzzy system. Integral quadratic constraints are used to describe various kinds of uncertainties of the plant. A sufficient condition for solvability is given in terms of linear matrix inequality problem which can be efficiently solved using a convex optimization technique. In order to demonstrate the Proposed method, a numerical design example is provided.

Fault Diagnosis and Accommodation of Linear Stochastic Systems with Unknown Disturbances

  • Lee, Jong-Hyo;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.270-276
    • /
    • 2002
  • An integrated robust fault diagnosis and fault accommodation strategy for a class of linear stochastic systems subjected to unknown disturbances is presented under the assumption that only a single fault may occur at a given time. The strategy is based on the fault isolation and estimation using a bank of robust two-stage Kalman filters and introduction of the additive compensation input for cancelling out the fault's effect on the system. Each filter is set up such that the residual is decoupled from unknown disturbances and fault with the influence vector designed in the filter. Simulation results for the simplified longitudinal flight control system with parameter uncertainties, process and sensor noises demonstrate the effectiveness of the present approach.

Pressure Control of Hydraulic Cylinder using high Speed On-Off Solenoid Valve (고속 온-오프 전자 밸브를 사용한 유압 실린더의 압력 제어)

  • 김상수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 1999
  • In this study a new pattern of pressure control of hydraulic cylinder using high speed On-Off solenoid valve in the electro-hydraulic system has been suggested. The control valve is 3-way high speed On-Off solenoid valve which is operated by PWM(Pulse Width Modulation)control signal. The high speed On-Off solenoid valve has a tendency to induce severe pressure fluctuation in the hydraulic actuator so it has not been used for the purpose of closed loop control with direct pres-sure feedback. In this study closed loop control with direct pressure feedback is enabled by using a digital filter which has linear minimum mean square filter algorithm. Through some experiments it is confirmed that stable pressure control can be realized by the proposed control technique.

  • PDF