• Title/Summary/Keyword: line-width

Search Result 1,552, Processing Time 0.032 seconds

Symmetry of GaAsN Conduction-band Minimum: Resonant Raman Scattering Study (GaAsN 전도띠 바닥의 대칭성: 공명라만산란연구)

  • Seong M.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.162-167
    • /
    • 2006
  • The symmetry of the conduction-band minimum of $GaAs_{1-x}N_{x}$ is probed by performing resonant Raman scattering (RRS) on thin layers of $GaAs_{1-x}N_{x}(x{\leq}0.7)$ epitaxially grown on Ge substrates. Strong resonance enhancement of the LO(longitudinal optical)-phonon Raman intensity is observed with excitation energies near the $E_0$ as well as $E_+$ transitions, However, in contrast to the distinct LO-phonon line-width resonance enhancement and activation of various X and L zone-boundary phonons brought about slightly below and near the $E_+$ transition, respectively, we have not observed any resonant LO-phonon line-width broadening or activation of sharp zone-boundary phonons near the $E_0$ transition. The observed RRS results reveal that the conduction-band minimum of GaAsN predominantly consists of the delocalized GaAs bulk-like states of ${\Gamma}$ symmetry.

A Study on Miniaturization and Design Flexibility of an Elliptic-Response Open-Loop Resonator Filter (타원응답 개방 루프 공진기 필터의 소형화 및 설계 유연성에 관한 연구)

  • 안창수;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.11
    • /
    • pp.1082-1089
    • /
    • 2004
  • In this paper, miniaturization of an elliptic-response open-loop resonator filter and design flexibility using similarity transformation of the coupling matrix are proposed. Moreover, the filter with wider fractional bandwidth is designed by the proposed method. In order to verify the proposed method, three 4th-order elliptic-response open-loop resonator filters with a relative bandwidth of 4 % at the center frequency of 2.0 GHz are designed. One is realized with constant-width microstrip line resonator and the others are implemented with different-width microstrip line resonator. Compared with the former one, the latter have shown the size reduction of 13 % and 25 %, respectively. Since it may not be possible to implement the resonators with very narrow spacing for the required coupling coefficient filters with two different configurations representing same response characteristic through similarity transformation of the coupling matrix are proposed. From this design flexibility, a filter with a relative bandwidth of 8 % at the center frequency of 2.0 GHz is designed with realizable design parameters.

Experimental Investigations into the Precision Cutting of High-pressured Jet for Thin Multi-layered Material (다층박판재료의 초고압 젯 정밀가공에 대한 실험적 연구)

  • Park, Kang-Su;Bahk, Yeon-Kyeung;Lee, Jung-Han;Lee, Chae-Moon;Go, Jeung-Sang;Shin, Bo-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.44-50
    • /
    • 2009
  • High-pressured jetting is now widely used in the advanced cutting processes of polymers, metals, glass, ceramics and composite materials because of some advantages such as heatless and non-contacting cutting. Similarly to the focused laser beam machining, it is well known as a type of high-density energy processes. High-pressured jetting is going to be developed not only to minimize the cutting line width but also to achieve the short cutting time as soon as possible. However, the interaction behavior between a work piece and high-velocity abrasive particles during the high-pressured jet cutting makes the impact mechanism even more complicated. Conventional high-pressured jetting is still difficult to apply to precision cutting of micro-scaled thin work piece such as thin metal sheets, thin ceramic substrates, thin glass plates and TMM (Thin multi-layered materials). In this paper, we proposed the advanced high-pressured jetting technology by introducing a new abrasives supplying method and investigated the optimal process conditions of the cutting pressure, the cutting velocity and SOD (Standoff distance).

Flow Characteristics of Two-Dimensional Turbulent Stepped Wall Jet (2次元 亂流 Stepped Wall Jet 의 流動特性)

  • 부정숙;김경천;박진호;강창수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.6
    • /
    • pp.732-742
    • /
    • 1985
  • Measurements of mean velocity and turbulence characteristics are obtained with a linearized constant temperature hot-wire anemometer in a two-dimensional turbulent jet discharging parallel to a flate. Wall static pressure distribution is also measure. The Reynolds number based on the jet nozzle width (D) is about 42,000 and the step height is 2.5D. The reattachment length is found to be 7.5D by using both wool tuft and oil methods. Upstream of the reattachment point, there exist double coherent structures and mean velocity, Reynolds stresses and triple product profiles are asymmetric about jet center line due to the influence of streamline curvature and recirculating flow region. Near the reattachment point, wall static pressure and turbulence quantities change its shape rapidly because of the large eddies by the solid wall. Especially, turbulence intensity has a maximum value in the reattachment regin, then decreases slowly in the redeveloping wall jet ragion. Downstream of X/D=14, a single large scale eddy structure is formed. Far downstream affer the reattachment(X/D.geq.18) mean velocity profile, the decay of maximum velocity and the variation of jet half width are nearly similar to those of plane wall jet, but the Reynolds stresses are higher than those of the latter.

Design of an Optical System for Iris Photographing (홍채 촬영용 광학계 설계)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.39-44
    • /
    • 2009
  • Purpose: To design a mini optical system photographing the iris, which is used in the iridology. Methods: We designed a mini optical system photographing the iris by using the Sigma 2000 design program. Results: We designed a mini optical system photographing the iris, which is suitable in the CCD using a micro actuator for auto-focusing, of which characteristics have the TCL of 30 mm, a magnification of -0.65, about 8.0 mm distance from the 1st lens to the last lens, the max barrel diameter of 11 mm, and about 1 mm of the effective stop diameter. Also the resolution line width of this system is characterised by 92 lps/mm at the 30% MTF value criterion. Conclusions: By designing an optical system of which characteristics have the TCL of 30 mm, about 8.0 mm distance from the 1st lens to the last lens, the max barrel diameter of 11 mm, and the resolution line width of $5.4{\mu}m$ at the 30% MTF value criterion, we could miniaturize the iris photographing optical system.

  • PDF

Design of Imaging Optical System with 24mm Focal length for MWIR (MWIR용 24mm 초점거리를 가지는 결상광학계의 설계)

  • Lee, Sang-Kil;Lee, Dong-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.203-207
    • /
    • 2018
  • This paper deals with the design and development of a lens system capable of imaging an infrared image of $3{\sim}5{\mu}m$ wavelength bands with a focal length of 24mm and good atmospheric transmission characteristics. The design used CodeV, a commercial design program, and the optimization is carried out with weighting to eliminate chromatic aberration, spherical aberration and distortion. The designed lens system consists of two lenses consisting of Si and Ge. Each lens has an aspherical surface on one side. And this optical system has the resolution of the characteristics that the MTF value is 0.40 at the line width of 29lp/mm and the MTF value is 0.25 at the line width of 20lp/mm. This optical system is considered to have the capability to be applied to the thermal imaging camera for MWIR using the $206{\times}156$ array infrared detector of $25{\mu}m$ pixels and the $320{\times}240$ array infrared detector of $17{\mu}m$ pixels.

The Analysis of the T-shaped Microstripline-Fed Printed Slot Antenna with Unidirectional Radiation (한방향 복사특성을 갖는 T-모양 급전선 마이크로스트립 슬롯 안테나의 해석)

  • Jang, Yong-Woong;Oh, Dong-Jin
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.103-109
    • /
    • 1999
  • In this paper, we proposed to a new structure of T-shaped fed microstrip slot antenna using 2-layers dielectric material with a directional radiation characteristic. When the slot antenna of bi-directional radiation want to radiate only one direction, the reflector must be set up, but this antenna does'nt need set up reflector. T-shaped microstrip feed line is proposed for a better impedance matching to the microstrip slot antenna in a various range of slot widths. It was also found that the bandwidth of this antenna is proportional to the slot width. It was also found that the radiation resistance of this feed line structure is quite constant and low regardless to the slot width. We also analyzed this antenna by using the FDTD method, and calculating waves and electric field distribution in the time domain. we also are calculated return loss, VSWR, and radiation pattern in the frequency domain by Fourier transforming the time domain results, respectively. From the measured results, bandwidth was 34.8% in the center frequency. These results were in relatively good accordance with the calculated values.

  • PDF

회원 신윤복 풍용도에 표현된 복식미의 연구

  • 김인경
    • Journal of the Korean Society of Costume
    • /
    • v.25
    • /
    • pp.5-20
    • /
    • 1995
  • The fashion of late Yi dynasty had explored a possibility of new fashional beauty from its own experiences throughout the history of Korean fashion excluding any interference of foreign fashions, and brought out some characteristics ; first, the aesthetical value focused on the more human fashion resulted in the exposure of waist. This aesthetical change in the fashion of late Yi dynasty produced out results as follows ; the length and width of jacket became short and narrow maintaining the basic form, while the width of skirt became increased to be contrasted exceptionally with the upper coat. This mode of fashion reveals the transitional movement from the emphasis on balance to that on unbalance in the late period of Yi dynasty. But regarding the fact that the proportional change by the ways of putting on skirt became to be similar to the golden ratio, we can see many examples throughout the folk paintings by Shin Yun bok, we find that the fashional beauty of that age pursued ideal harmony and unity all the time being in spite of its tendency toward non-refinement. Second, we see another peculiarity in the mode of woman's fashion from the paintings by Shin Yun-bok who always depicted the hu-man nature frankly. For example, the jacket became shorter to emphasize lady's slim waist, and underwears began to be exposed after the upper part of skirt had been to expose lady's waist while the bottom line pulled up highter than before. Thus, as the function of robe had changed from a mere means of covering into an expression of beauty, the fashion of late Yi dynasty began to express a perfectly new beauty possessing an erotic mood and sensu-ality of a woman, which was its inner aesthetic need. Third, this emergence of new fashional beauty made the mental value of man and the aesthetic views of that time quite different from the previous ones, and finally there came various expressions of a new beauty. There-fore, the woman's fashion of late Yi dynasty is noted for the exposure and emphasis on the body line of a woman after the aesthetic view-point had changed of time toward pragmatism and humanism, while upholding the traditions of Korean clothes and pride for the nation. And our ancestors realized very Korean fashional beauty by pursuing the expressional ways of gentle, indirect emphasis upon the feminine and natural beauty to exclude and ar-tificial, direct and straightforward exposures and images.

  • PDF

The hidden X suture: a technical note on a novel suture technique for alveolar ridge preservation

  • Park, Jung-Chul;Koo, Ki-Tae;Lim, Hyun-Chang
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.415-425
    • /
    • 2016
  • Purpose: The present study investigated the impact of 2 different suture techniques, the conventional crossed mattress suture (X suture) and the novel hidden X suture, for alveolar ridge preservation (ARP) with an open healing approach. Methods: This study was a prospective randomized controlled clinical trial. Fourteen patients requiring extraction of the maxillary or mandibular posterior teeth were enrolled and allocated into 2 groups. After extraction, demineralized bovine bone matrix mixed with 10% collagen (DBBM-C) was grafted and the socket was covered by porcine collagen membrane in a double-layer fashion. No attempt to obtain primary closure was made. The hidden X suture and conventional X suture techniques were performed in the test and control groups, respectively. Cone-beam computed tomographic (CBCT) images were taken immediately after the graft procedure and before implant surgery 4 months later. Additionally, the change in the mucogingival junction (MGJ) position was measured and was compared after extraction, after suturing, and 4 months after the operation. Results: All sites healed without any complications. Clinical evaluations showed that the MGJ line shifted to the lingual side immediately after the application of the X suture by $1.56{\pm}0.90mm$ in the control group, while the application of the hidden X suture rather pushed the MGJ line slightly to the buccal side by $0.25{\pm}0.66mm$. It was demonstrated that the amount of keratinized tissue (KT) preserved on the buccal side was significantly greater in the hidden X suture group 4 months after the procedure (P<0.05). Radiographic analysis showed that the hidden X suture had a significant effect in preserving horizontal width and minimizing vertical reduction in comparison to X suture (P<0.05). Conclusions: Our study provided clinical and radiographic verification of the efficacy of the hidden X suture in preserving the width of KT and the dimensions of the alveolar ridge after ARP.

Changes of Muscle Activity and Cephalometric Variables Related to Head Posture (두부자세에 따른 근활성과 측모두부방사선계측치의 변화에 관한 연구)

  • Kim, Byung-Wook;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.2
    • /
    • pp.189-206
    • /
    • 1999
  • This study was performed to investigate the factors affecting muscle activity and cephalometric variables according to change of head postures. For this study, 150 patients with temporomandibular disorders and 80 dental students without any signs and symptoms of temporomandibular disorders were selected as the patients group and as the normal group, respectively. Head position to body-midline in frontal plane and upper quarter posture to body plumb line in sagittal plane were observed clinically and electromyographic(EMG) activity of anterior temporalis, masseter, sternocleidomastoideus, and trapezius on clenching were recorded with $BioEMG^{(R)}$ in four head postures, which were natural head posture(NHP), forward head posture(FHP), $20^{\circ}$ upward head posture(UHP), and $20^{\circ}$ downward head posture(DHP). Cephaloradiographs were also taken in the same head postures as in EMG taking, but that was taken only in NHP for the patient group. Cephalometric variables measured were SN angle, CVT angle, atlas inclination angle, occlusal plane angle, Me-C2 angle, pharyngeal width, occiput~axis distance, area of pharyngeal space, and cervical curvature. The data were analyzed by SAS statistical program. The results of this study were as follows : 1. Between the patient and the normal group, there were significant difference in distance from plumb line to acromion, eye-tragus angle, electromyographic activity of the four muscles, and cephalometric variables of linear measurement. 2. There was no consistent pattern of correlation between upper quarter posture, EMG activity and cephalometric variables in any case without relation to cervical curvature and head position in frontal plane. 3. Sternocleidomastoid muscle only showed variation of electromyographic activty with changes of head postures, but all the muscles did show correlation with head postures. 4. All the cephalometric variables measured in this study showed difference of mean value by head posture, and CVT angle, pharyngeal width, occiput-atlas distance, and area of pharyngeal space showed correlation between these variables with change from NHP to FHP, and from NHP to UHP.

  • PDF