• Title/Summary/Keyword: line reliability

Search Result 1,093, Processing Time 0.031 seconds

Surveillance System For Extra High Voltage Cable (초고압 CABLE 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF

STRUCTURAL SAFTY EVALUATION OF COMPRESSOR DRIVING MOTOR SHAFT SYSTEM (컴프레서 구동용 전동기 축계의 구조 안전성 평가)

  • Jung, Kun-Hwa;Kwak, Ju-Ho;Kim, Byung-Joo;Lee, Jong-Moon
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1031-1036
    • /
    • 2007
  • Torsional vibration analysis is necessary at design stage to ensure the reliability of a system particularly when the driven machine is a reciprocating compressor. This paper contains the results of torsional vibration analysis and fatigue strength evaluation for 540 kW compressor driving motor. Torsional vibration analysis showed that the $2^{nd}$ torsional mode of the entire shaft system has the possibility of resonance with the $14^{th}$ order excitation of compressor and twin line frequency of motor at operating speed. Therefore, the analyses were required to ensure the structural reliability of the motor. The fatigue strength was evaluated for the shaft and inner fans using the results of forced vibration analysis. It is concluded that the motor has sufficient fatigue strength under normal operating condition.

  • PDF

Thermal Dissipation Study of IT Module Simulation (IT 모듈에서의 열전달 해석과 방열 특성 연구)

  • Kim, Won-Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.427-431
    • /
    • 2020
  • In this Study, as the structure of IT module for smart phone display becomes thin to catch up with slim product trend, the reliability of display module is on the rise as a issue for product design. Especially, almost part of cellular phone should undergo thermal dissipation test. thus many manufacturers have considered design guide line using CAE and simulation for more effective usage of limited resources on the market. This test simulates the case when cellular phone slips through user's fingers while he is talking on the phone. This paper studies a thermal simulation of display module in smart phone. This design for reliability improvements are suggested on the basis of the results of FVM Analysis and display of IT module and smart phone design.

Design and Implementation of Monitoring Software for Heterogeneous Control Network (이종 제어 네트워크를 위한 모니터링 소프트웨어의 설계 및 구현)

  • Heo, Jong-Man;Ha, Jae-Yeol;Kim, Nam-Hoon;Jeon, Joseph;Lee, Kam-Rok;Chung, Bum-Jin;Kwon, Wook-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.114-116
    • /
    • 2006
  • XCP (eXtensive Control Protocol) is an information oriented protocol which delivers information with high reliability according to the predefined rule. XCP network system can be implemented on top of several physical layer such as power line, IEEE 802.15.4 and so on. In this paper. a monitoring software that evaluates the reliability and performance of the XCP network is designed and implemented. This paper presents the structure and method of the packet monitoring in the network through several interfaces such as RS-232, ethernet.

  • PDF

Short Term Sensor's Drift Analysis and Compensation Using Internal Normalization (내부 최적화를 이용한 화학 센서의 단기 드리프트 분석 및 보정)

  • Jeon, Jin-Young;Baek, Jong-Hyun;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.270-273
    • /
    • 2015
  • One of the main problems when working the chemical sensor is the lack of repeatability and reproducibility of the sensor response. If the problem is not properly taken into consideration, the stability and reliability of the system using chemical sensors would be decreased. In this paper we analyzed the sensor's drift of short term and proposed a compensation method for reducing the effects of the drift in order to improve the stability and the reliability of the chemical sensor. The sensor drift was analyzed by a trend line graph and CV(coefficient of variation) was used to quantify. And we compensated for the drift by using the internal normalization. As a result it was found that the value of CV was decreased after compensation.

Implementation of Optical Magnetic Field Sensor for Measurement of Over Current (과전류 계측을 위한 광자계센서의 구현)

  • Park, Hae-Soo;Roh, Jong-Dae;Kim, Yo-Hee;Park, Byung-Seok;Ahn, Seong-Joon;Jo, Hong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1871-1873
    • /
    • 1997
  • The conventional current transformers are often take faults and out of order that for detect to over current of electric power lines because electromagnetic interference. But, it is possible to implement protection relay of high reliability using optical magnetic field sensor which are immunity and small size. The optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. And it is not necessary to make with capacitance of electric power lines as optical magnetic field sensor is have linearity from 0 to about 20kA. In this study, we designed and constructed compensative feedback circuit in order to minimize of optical power intensity variation with environ- mental variations(temperature, drive current) of light source. And this system have highest optical advantages and reliability.

  • PDF

Prediction of Dynamic Expected Time to System Failure

  • Oh, Deog-Yeon;Lee, Chong-Chul
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.244-250
    • /
    • 1997
  • The mean time to failure (MTTF) expressing the mean value of the system life is a measure of system effectiveness. To estimate the remaining life of component and/or system, the dynamic mean time to failure concept is suggested. It is the time-dependent Property depending on the status of components. The Kalman filter is used to estimate the reliability of components using the on-line information (directly measured sensor output or device-specific diagnostics in the intelligent sensor) in form of the numerical value (state factor). This factor considers the persistency of the fault condition and confidence level in measurement. If there is a complex system with many components, each calculated reliability's or components are combined, which results in the dynamic MTTF or system. The illustrative examples are discussed. The results show that the dynamic MTTF can well express the component and system failure behaviour whether any kinds of failure are occurred or not.

  • PDF

A Study on the Construction of Failure Information System for Korea High Speed Train (한국형 고속열차의 고장정보체계 구축에 관한 연구)

  • Seo Sung-ll;Park Choon-Soo;Mok Jin-Yong;Lee Tae-Hyung;Kim Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.296-301
    • /
    • 2004
  • Korea High Speed Train has been developed for 6 years by domestic technologies and is being tested on the high speed line to prove the reliability of its systems. In this study, to record the failure data and get the information on the reliability, availability, maintainability of the train, a failure information system was developed and applied. The concept and function of the failure information system is introduced and its usefulness is shown.

  • PDF

A Study on Development of Arc Fault Circuit Interrupter Used in House Distribution Line (옥내 배전선로용 아크차단기 개발에 관한 연구)

  • Kwak, Dong-Kurl;Choi, Jung-Kyu;Park, Young-Jic;Kim, Jin-Hwan;Son, Jae-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.546-547
    • /
    • 2013
  • This paper proposes an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. It perceives a voltage instantaneously at the time of voltage drop. and occurrence. It is an AFCI of the new concept which operates with high reliability. The primary reason of electric fire is arc and spark. It prevents an electric fire or an electric leakage accident with quick responsiveness. Earth Leakage Circuit Breaker(ELB), Molded_case Circuit Breaker (MCCB) or Residual Current Protective Device(RCD) can not cut off electric arc or spark to be a major factor of electrical fire. This theory will be able to intercept an arc or a spark. which occurrence with periodic. Consequently It raises a reliability and validates a practicality of RCD.

  • PDF

Ananalzing fault current and Protective coordination in the underground line (지중배전선로의 고장전류 크기 및 보호협조분석)

  • Cho, Nam-Hun;Ha, Bok-Nam;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF