• Title/Summary/Keyword: line reliability

Search Result 1,092, Processing Time 0.028 seconds

A Fast Seam Tracking Algorithm for Laser Welding (레이져 용접을 위한 고속 용접선 추적 알고리즘)

  • 배재욱
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.52-55
    • /
    • 1997
  • This paper discusses an automatic visual-servoing system, in which a laser and a CCD camera are used for imaging the pattern of joint groove. The algorithm used here is simple and robust to find out the gap width and gap center. As a consequence, the speed of algorithm is very fast and optimized. A feature of this system is that it processes only by summing the vertical line and horizontal line of screen without any image preprocessing in order to get the energy information of lines alternatively. It is practical and useful for the system requiring a fast process time of vision.

  • PDF

W Polymetal Gate Technology for Giga Bit DRAM

  • Jung, Jong-Wan;Han, Sang-Beom;Lee, Kyungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.1
    • /
    • pp.31-39
    • /
    • 2001
  • W polymetal gate technology for giga bit DRAM are presented. Key module processes for polymetal gate are studied in detail. $W/WN_x/poly-silicon$ adopted for a word line of 256Mbit DRAM has good gate oxide integrity and junction leakage characteristics through full integration, which is comparable to those of conventional $WSi_x$/Poly-silicon gate process. These results undoubtedly show that $W/WN_x/poly-silicon$ is the strongest candidate as a word line for Giga bit DRAM.

  • PDF

THE TREND OF DIAGNOSTIC METHODS FOR POWER CABLE (전력(電力)케이블 열화진단(劣化診斷) 기술(技術)의 동향(動向))

  • Hahn, K.M.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.779-783
    • /
    • 1992
  • In recent years, it is strongly required to supply high quality electrical power without insulation failure in distribution power cables. Therefore the exact measurement and judgment ar out deterioration degree of cables are essential to increase that supplying reliability. This paper will introduce various diagnostic methods of off-line and live-line cables also propose the judgement criteria and newly trend of diagnostic technique at present.

  • PDF

An Application of CMOS Gate Array Integrated Circuits to Switching Network and Digital Line Concentrator (스위칭 네트워크와 디지털 접선 장치에서의 CMOS 게이트 어레이 IC 적용)

  • 박항구;박권철;조용현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.652-657
    • /
    • 1987
  • This paper describes an application of CMOS Gate Array Integrated Cricuits to the implementation of three functional units: A Multiplexer, Time Switch, and Demultiplexer in the Switching Network and Digital Line Concentrator of TDX-1 system, which is a fully digital time division electronic switching system in Korea. The application of CMOS Gate Array Integrated Circuits significantly improves the overall system performance in terms of power consumption, cost, size, reliability, and timing margin, etc.

  • PDF

Crosstalk analysis of laser-diode array modules for wavelength division multiplexing (파장 분할 다중화 방식을 위한 고속 레이저 다이오드 배열 모듈의 혼신해석)

  • 김성일;이해영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.7
    • /
    • pp.71-78
    • /
    • 1997
  • In this paper, we analyzed the crosstalk characteristics of LD array modules for WDM and improved the crosstalk levels using a screening line between access lines. From the calculation resutls, we have found that inductive crosstalk of access lines is dominant for the low impedance LD arrays with short bondwire interconnections. The proposed array interconnecton with the screening line and ouble bondwires, rduces the crosstalk level about 10dB compared to conventional interconnections using simple access lines and a single bondwire. This proposed structure also can be easily imlemented with transmission reliability.

  • PDF

Precision Industrial Ink Jet Printing Technology for Full Color PLED Display Manufacturing

  • Edwards, Chuck;Bennett, Richard;Lee, Jueng-Gil;Silz, Kenneth
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.141-143
    • /
    • 2002
  • Litrex Ink Jet equipment offers prospect for reliable and low cost manufacturing process for PLED technology. The design concept of 140P system that we are developing meets requirement of process/equipment for PLED manufacturing line in terms of higher mechanical accuracy, in-line monitoring system of print head, high precision of process capability, reasonable through-put, high reliability/easier maintenance and no particle generation.

  • PDF

Recent research and technical trend of power cable system (전력 케이블의 최근 연구 및 기술 동향)

  • Kim, Dong-Uk;Choe, Myeong-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.616-618
    • /
    • 2000
  • This paper describes the recent research and technical trend of power cable system. Compact sizing with long length and large capacity is the main trend of the power cable. From the manufacturing process to the monitoring of the underground power line, various new techniques are being developed for reliability and high quality such as in-line monitoring system, triple common extrusion, PD measurement system, new type completion test, etc.

  • PDF

Development of Bridge Inspection Reliability and Improvement Strategy (교량 점검신뢰도 분석법 개발과 향상방안)

  • Jeong, Yo-Seok;Kim, Woo-Seok;Lee, Il-Keun;Lee, Jae-Ha
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.50-57
    • /
    • 2016
  • The present study proposed three inspection reliability indices which compared inspection results evaluated at in-depth(routine) inspection and in-depth safety inspection; Nominal inspection reliability index, Real inspection reliability index, and DS nominal inspection reliability index. The methods to improve the inspection reliability were also proposed. Since bridge inspection process is critical to ensuring the safety of bridges and identifying repair and maintenance needs, the quality of the inspection data produced from the inspection process is very important. Consequently, the inspection reliability indices were suggested to evaluate quality of current inspection practices. Specifically, approximately 85% of inspection errors evaluated by the DS nominal inspection reliability index are within 1 rating grade(equal to or less than damage score ${\pm}0.1$). In order to improve the inspection reliability, transportation agency should implement QC(Quality Control) practices and develop professional expertises of inspectors by higher requirements for inspectors, on-off line inspection training and etc.

Development of Live-line Insulator Tester and Its Application to 154kV Power Lines - Part 1 : Tester Development (활선애자점검기의 개발 및 154kV 선로에의 적용 - 제1부 : 점검기 개발)

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak;Oh, Ki-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.83-88
    • /
    • 2010
  • A new live-line insulator tester was developed to detect faulty insulators in 154kV power transmission lines. This paper is the first part of the two-part paper and deals with its tester development. The developed tester has the following characteristics. First, it automates parts of the insulator inspection process by using a sensor and an actuator, and secondly, it sustains its weight by itself, not by a lineman. Finally, it measures the insulation resistance of an insulator together with its distribution voltage to provide more information for its analysis and diagnosis. These leads to the improvement of its operation efficiency, measurement reliability and usability. Its effectiveness was validated by live-line field tests in actual power lines.

Prediction of Dynamic Line Rating by Time Series Weather Models (시계열 기상 모델을 이용한 동적 송전 용량의 예측)

  • Kim, Dong-Min;Bae, In-Su;Kim, Jin-O;Chang, Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.35-38
    • /
    • 2005
  • This paper suggests the method that forecast Dynamic Line Rating (DLR). Thermal Overload Risk (TOR) of next time is forecasted based on current weather condition and DLR value by Monte Carlo Simulation (MCS). To model weather element of transmission line for MCS, we will propose the use of weather forecast system and statistical models that time series law is applied. Also, through case study, forecasted TOR probability confirmed can utilize by standard that decide DLR of next time. In short, proposed method may be used usefully to keep safety of transmission line and reliability of supply of electric Power by forecasting transmission capacity of next time.

  • PDF