• Title/Summary/Keyword: linac

Search Result 306, Processing Time 0.038 seconds

Precision evaluation of the treatment that used coordinates confirmation of couch in case of two forgets adjoined. (Couch의 좌표 확인을 이용한 치료 위치 이동의 정확성 평가)

  • Seo Jeong-min;Jeong Cheon-young;Park Young-hwan;Song Ki-won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.35-40
    • /
    • 2003
  • I. Purpose Confirming an error to be able to break out in a method to move couch manually while operator sees the skin marks on patient in case of curing head who got 2 targets adjoined, so we analyze coordinates price of couch, evaluate reproducibility and precision of change movements between targets. II. Materials and Methods In radiotherapy, for confirming errors in manual movements by operators by exchanging between two targets to treat patient head, we read coordinates price(vertical, longitudinal, lateral three directions of couch) shown on a monitor of LINAC( CL 2100, Varian, USA) in order to evaluate accuracy about the length that moved in time for moving couch manually. After reading movement length of coordinates recorded in three directions of all treatment, we compared distance between targets recorded in RTP(Pinnacle, ADAC, USA) with reading coordinates price of couch, setting actually done the same patient for ten times, coordinates were recorded, treated for evaluating averages and degrees of errors and standard deviations. III. Results In method to confirm skin marks of patient by operators' view and to move couch manually, average standard deviations of movements between two targets are vertical 1.4mm, longitudinal 0.9mm, lateral 2.2mm in each direction. As for the error in straight dimension, it is about 3.6mm averages and 5.1mm maximum. The average of errors in each directions was vertical 1mm, longitudinal 0.7mm, lateral 2.7mm. The greatest error broke out in lateral direction with $25\%$ of all cases ; to exceed an error average. IV. Conclusions If operators moved manually couch for changing target points, errors about 3.6mm average degrees occur. It is important that operators confirm the errors prices of actual couch coordinates for asking a correct movement between the targets adjoined each other ; in case of treatment demanding high precision like 3D conformal therapy or IMRT. Therefore, if we apply couch coordinates confirmation to reproducibility and to precision evaluation of treatment, it's expected that we can execute high-quality radiotherapy.

  • PDF

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Clinical Experience of LINAC-based Stereotactic Radiosurgery for Angiographically Occult Vascular Malformations (혈관조영상 잠재혈관기형에 대한 선형가속기형 정위방사선수술의 임상경험)

  • Kim Dae Yong;Ahn Yong Chan;Lee Jung Il;Nam Do-Hyun;Lim Do Hoon;Lee Jeong Eun;Yeo Inhwan;Huh Seung Jae;Noh Young Joo;Shin Seong Soo;Hong Seung-Chyul;Kim Jong Hyun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • Purpose : To establish the role of stereotactic radiosurgery (SRS) for the treatment of patients with angiographically occult vascular malformation (AOVM). Materials and Methods : Eleven patients (12 lesions) with AOVM were treated with linear accelerator-based SRS between February 1995 and December 1999. A magnetic resonance imaging of each patients showed well-circumscribed vascular lesion with reticulated core of heterogeneous signal intensity and peripheral rim of low signal intensity. SRS were peformed with the median peripheral dose of 16 Gy (range 13~25). A single isocenter was used with median collimator size of 14 mm (range 8~20) diameter. Results : With a median follow-up period of 42 months (range 12~56), rebleeding occurred in 3 AOVMS at 5, 6 and 12 months after SRS but no further bleeding did. Two patients experienced radiation-induced necrosis associated with permanent neurologic deficit and one patient showed transient edema of increased 72 signal intensity. Conclusion : SRS may be effective for the prevention of rebleeding in AOVM located in surgically inaccessible region of the brain. Careful consideration should be needed in the decision of case selection and dose prescription because the incidence of radiation-induced complications is too high to be accepted.

  • PDF

Preliminary Result in Patients with Primary Hepatoma Treated by Stereotactic Radiotherapy (원발성 간암에 대한 정위방사선치료의 예비결과)

  • Kang Ki Mun;Choi Ihl Bohng;Kim In Ah;Choi Byung Ock;Kang Young Nam;Chai Gyu Young;Han Sung Tae;Chung Gyu Won
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.34-39
    • /
    • 2001
  • Purpose : It is not common to evaluate the response of the fractionated stereotactic radiotherapy (SRT) to primary hepatoma as compared with conventional radiotherapy. The purpose of the study was to take the preliminary result on the clinical trial of primary hepatoma by SRT. Materials and Methods : From July 1999 to March 2000, thirty three patients were hospitalized in the St. Mary's Hospital, and treated with SRT for extracranial tumors. Among them, 13 patients were diagnosed to primary hepatoma and then applied by frameless SRT using 6 MV linac accelerator. There were 12 male and 1 female patients. They had the age of $ 44\~66$ year old (median : 59) and the tumor size of $10\~825\;cc$ (median : 185 cc). SRT was given to them $3\~5$ fractions a week (5 Gy/fraction, $90\%$ isodose line) for $2\~3$ weeks. Median dose of SRT was 50 Gy and the range was $30\~50\;Gy$. Results : Follow-up period ranged from 3 months to 13 months with median of 8 months. After treating SRT to thirteen patients with primary hepatoma, the response of the tumor was examined by abdominal CT : they are classified by 1 complete regression $(7.7\%)$, 7 partial regression $(53.8\%)$, 4 minimal regression $(30.8\%)$, 1 stable disease $(7.7\%)$. The positive responses more than partial remission were 8 patients $(61.5\%)$ after the treatment. The level of serum alpha-fetoprotein (AFP) after the treatment as compared with pretreatment had been $92.3\%$ decreased. There was no severe complication except dyspepsia $84.6\%$, mild nausea $69.2\%$, transient decreased of hepatic function $15.4\%$ and fever $7.7\%$. Conclusion : SRT to the patients with primary hepatoma was potentially suggested to become the safe and more effective tool than the conventional radiotherapy even though there were relatively short duration of follow-up and small numbers to be tested.

  • PDF

Effect of the Space Dose Rate due to Change of X-ray Irradiation Energy and MU Value in Radiation Therapy Room (선형가속기의 엑스선 조사에너지와 MU값의 변화가 치료실 내 공간선량률 변화에 미치는 영향)

  • Kwon, Hyeonghyo;Park, Geonryul;Kim, Minji;Jo, Yeongdan;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.77-83
    • /
    • 2020
  • This study investigated the radiation protection of therapeutic radiologists. Based on the change in X-ray energy and MU value, the space dose rate in the treatment room after the irradiation was measured. 6MV, 10MV and 15MV photon beams were exposed to radiation inside the treatment room based on 300MU, 600MU and 1000MU using a linear accelerator. And repeated 10 times under the same conditions. As a result of the experiment, 0.1555 μSv/h for 6MV 300MU, 0.157 μSv /h for 300sec, 0.152 μSv/h, 0.156 μSv/h for 600MU, and 0.157 μSv/h 0.152 μSv/h for 1000MU. 300MU of 10MV was 0.49 μSv/h, 0.309 μSv/h, and 0.69 μSv/h, 0.416 μSv/h for 600MU, respectively, and 1000MU was 0.977 μSv/h and 0.478 μSv/h, respectively. The 300MU of 15MV was 3.02 μSv/h, 1.2 μSv/h, 5.459 μSv/h at 600MU, 7.34 μSv/h at 1.836 μSv/h 1000MU, and 2.709 μSv/h. The average spatial dose rate of 6MV was not significantly different from the natural spatial dose rate in the treatment room. High spatial dose rates were measured at 10 MV and 15 MV and were attenuated over time. Therefore, entering the treatment room after a certain period of time (more than 60 seconds) is considered to be effective to prevent the exposure dose of radiation workers.

Filtration Characteristics of H2O-C6H12O6 Solution at Cell Membrane Model of Kidney which Irradiated by High Energy X-Ray (고에너지 엑스선을 조사한 신장의 세포막모델에서 포도당수용액 (H2O-C6H12O6)의 여과작용특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.85-95
    • /
    • 2020
  • The filtration characteristics of H2O-C6H12O6 solution at cell membrane model in renal tubule which irradiated by high energy x-ray(linac 6MV) was investigated. The cell membrane model used in this experiment was a polysulfonated copolymerized membrane of m-phenylene-diamine(MPD) and trimesoyl chloride(TMC)-hexane. They were used to two cell membrane models(CM-1, CM-2). The cell membrane model composed of 0.5 wt% TMC-hexane solution(CM-2) had higher permeate flux(Jv) and rejection coefficient(R) than composed of 0.1 wt% TMC-hexane solution(CM-1). The permeate flux(Jv) and rejection coefficient(R) of H2O-C6H12O6 solution in two cell membrane models(CM-1, CM-2) were increased with increase of pressure drop and effective pressure difference. In this experiment range(pressure 1.5-4 MPa, temperature 36.5 ℃), permeate flux(Jv) of H2O solvent in irradiated membrane was found to be decreased about 20-30 times than non-irradiated membrane, permeate flux(Jv) and rejection coefficient(R) of H2O-C6H12O6 solution in irradiated membrane was found to be decreased about 2-13 times, about 4-6 times than non-irradiated membrane, respectively. The concentration increase of H2O-C6H12O6 solution at cell membrane model significantly was increased at rejection coefficient(R), was decreased at permeate flux(Jv). As the filtration of H2O-C6H12O6 solution in cell membrane model were abnormal, cell damages were appeared at cell.

The Effect of protein and lipioperoxide on White Ginseng(WG) and Fermenta Ginseng(FG) Extracts on the liver in Mice that was irradiated by radiation (방사선이 조사된 생쥐 간에서 백삼과 발효인삼추출물이 단백질 및 지질과산화에 미치는 효과)

  • Ko, In-Ho;Chang, Chae-Chul;Koh, Jeong-Sam
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.43-50
    • /
    • 2004
  • The effects of ginseng extracts on liver damage induced by high energy x-ray were studied. To one group of ICR male mice were given white(50 mg/kg/day for 7 days, orally) and fermenta ginseng extracts(500 mg/kg/day for 7 days, orally)before irrdiation. To another group were irradiated by 5 Gy dose of high energy x-ray. Contrast group were given with saline(0.1 ml). This study also investigated the effect between MDA, protein content and ginseng extracts on hepatic damage. This study measured the level of MDA(malondialdehyde), protein content in liver tissue. Administrating orally white (50 mg/kg/day for 7 days, orally)and fermenta ginseng extracts(500 mg/kg/day), the level of MDA were generally decreased and the inhibition was increased. And the protein contents were identical with control group. After irradiation, the protein contents were increased and MDA(malondialdehyde) was increased. Therefore, ginseng extracts increased antioxidative enzyme activity. And We know that the antioxidatant effect of extracts from white and fermenta ginseng protect radiation damage by direct antioxidant effect involving SOD, CAT, GPX. It was included that ginsengs can protect against the lipid peroxidation in radiation damage through its antioxidatant properties.

  • PDF

The Result of Radiotherapy for Pituitary Adenoma (뇌하수체 선종의 방사선치료 결과)

  • Lee, Hyun-Joo;Yang, Kwang-Mo;Cho, Heung-Lae;Shon, Seung-Chang;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.297-303
    • /
    • 1997
  • Purpose : To evaluate the prognostic factors for disease-free survival and long-term results of radiotherapy for pituitary adenoma. Methods and Materials : The study involved a retrospective review of out-come in a series of 27 patients with pituitary adenoma, between 1984 and 1995 at Paik hospital. The study included 20 patients treated with surgery and postoperative radiotherapy and 7 with radiotherapy alone. The patients were followed for 12-146 months (median : 97 months). Seventeen were men and 10 were women. The numbers of functioning and nonfunctioning pituitary adenorna were 22 and 5 respectively and those of microadenoma and macroadenoma were 4 and 23 respectively. The radiation doses of 5040-5580cGy (median : 5040cGy) were deliverd over 5-7 weeks, using 4MV LINAC. The prognostic factors were analyzed by log-rank test. Results: For radiation therapy alone, the 5YSR was 100% and progression free survival rate was 85.8%, The tumor was controlled in 6/7 (85.8%). For surgery and postoperative radiotherapy. the 5YSR, progression free survival rate and local control rate were 95%, 84.8%, and 89.5% respectively. The parameters of tumor size, hormone secretion, radiation dose. radiotherapy field size were evaluated in a uni- and multivariate analysis and all the factors were not statisticaIty significant (P>0.05). Eleven of 12 (92%) with visual field defect experienced normalization or improvement, and 5 for 7 evaluabie patients with hyperprolactinoma achived normalization in 4 and decrement in S patients. Only 2 patients developed mild degree of Panhypopituitarism. Conclusion: The radiotherapy appears to be effective in controiling clinical symptoms and signs resulting from pituitary adenoma. Local control rate with radiotherapy alone or with surgery and postoperative radiotherauy was comparable. There was a trend toward high recurrence rate in Patients with nonfunctioning or prolactin secretion tumor and larger radiation field sizes.

  • PDF

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Conservative Surgery and Primary Radiotherapy for Early Bresst Cancer: Yonsei Cancer Center Experience (조기 유방암에서 보존적 수술후 방사선치료: 연세암센터 경험)

  • Suh Chang Ok;Lee Hy De;Lee Kyung Sik;Jung Woo Hee;Oh Ki Keun;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.337-347
    • /
    • 1994
  • Breast conserving surgery and irradiation is now accepted as preferable treatment method for the patients with stage I and II breast cancer. Our institution activated team approach for breast conservation in 1991 and treated one hundred and fourty patients during the next three years. Purpose : To present our early experience with eligibility criteria, treatment techniques, and the morbidities of primary radiotherapy. Materials and Methods: Sixty four patients with early stage breast cancer who received breast conserving treatment between January 1991 and December 1992 were evaluated. All patients received partial mastectomy(wide excision to quadrantectomy) and axillary node dissection followed by radiotherapy. Total dose of 4500-5040 cGy in 5-5 1/2 weeks was given to entire involved breast and boost dose of 1000-2000 cGy in 1-2 weeks was given to the primary tumor site. Linac 4 MV X-ray was used for breast irradiation and electron beam was used for boost. Thirty five Patients received chemotherapy before or after radiotherapy. Patients characteristics, treatment techniques, and treatment related morbidities were analyzed. Results : Age distribution was ranged from 23 to 59 year old with median age of 40. Twenty-seven patients had T1 lesions and 34 patients had T2 lesions. In three patients, pathologic diagnosis was ductal carcinoma in situ. Thirty-seven Patients were N0 and 27 patients were Nl. There were three recurrences, one in the breast and two distant metastases during follow-up period(6-30 months, median 14 months). Only one breast recurrence occured at undetected separate lesion with microcalcifications on initial mammogram. There was no serious side reaction which interrupted treatment courses or severe late complication. Only one symptomatic radiation pneumonitis and one asymptomatic radiation pneumonitis were noted. Conclusions: Conservative surgery and primary radiotherapy for early breast cancer is Proven to be safe and comfortable treatment method without any major complication. Long-term follow up is needed to evaluate our treatment results in terms of loco-regional control rate, survival rate, and cosmetic effect.

  • PDF