• Title/Summary/Keyword: light wavelength

Search Result 1,424, Processing Time 0.023 seconds

Design and Analysis of Flame Signal Detection with the Combination of UV/IR Sensors (UV/IR센서 결합에 의한 불꽃 영상검출의 설계 및 분석)

  • Kang, Daeseok;Kim, Eunchong;Moon, Piljae;Sin, Wonho;Kang, Min-goo
    • Journal of Internet Computing and Services
    • /
    • v.14 no.2
    • /
    • pp.45-51
    • /
    • 2013
  • In this paper, the combination of ultraviolet and infrared sensors based design for flame signal detection algorithms was proposed with the application of light-wavelength from burning. And, the performance result of image detection was compared by an ultraviolet sensor, an infrared sensor, and the proposed dual-mode sensors(combination of ultraviolet and infrared sensors).

Study on the Preparation of Eu $Eu(TTA)_3(phen)$ Thin Films by Physical Vapor Deposition Method and Their Characterization (진공 증착법에 의한 $Eu(TTA)_3(phen)$ 박막의 제작 및 특성 연구)

  • Hwang, Jang-Hwan;Kwon, Oh-Kwan;Kim, Young-Kwan;Sohn, Byoung-Chung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.91-97
    • /
    • 1998
  • Thin films of $Eu(TTA)_3(phen)$, which was known to show red-light emitting properties, were deposited under various deposition condition. The thickness, surface morphology, and photoluminescence(PL) were measured with ${\alpha}$-step profiler, Atomic Force Microscopy(AFM), and PL measurement apparatus. It was found that the thickness of $Eu(TTA)_3(phen)$ film can be controlled precisely by adjusting the amounts of $Eu(TTA)_3(phen)$ in the boat. As the thickness of these films increases, the surface roughness also increases. A structure of $Al/Eu(TTA)_3(phen)(850{\AA})/TPD(600{\AA})/ITO$ was fabricated, Electroluminescence(EL) spectrum of which shows the peak at the wavelength of 618nm.

Spectral Reflectivity on Geological Materials in Yangsan-Dongrae Fault Area (양산-동래 단층 지역의 암석에 대한 분광학적 연구)

  • 姜必鍾;智光薰
    • Korean Journal of Remote Sensing
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1987
  • The study was performed to recognize the most preferable spectral chennels for discriminating geological materials using the portable radiometer. The portable radiometer covers the visible and short infrared regions from approximately 0.4 to 2.5 microns which are coincided with Landsat TM, and the rock samples used for the study are pyrophylites, andesites, granite, granodiorite and silicified sedimentary rocks which are collected in Yangsan-Dongrae fault area. The analysis of the rock sample provides a preliminary basis for determining the wavelength regions showing diagnostic spectral features and for discriminating hydrothermal altered rocks from the unaltered rocks. The measurement of spectral of spectral reflectance for the rock samples was carried out in the laboratory which environment condition such as temperature, light sources, and humidity are constant. The analysis of the measured data was based on correlation between the reflectance value of the rock samples, and the follow discriptions are output of the study. 1) Pyrophyllite shows absorption at 0.83 $\mu\textrm{m}$ due to the oxidation of pyrite, and absorption at 2.22 $\mu\textrm{m}$ due to OH. 2) The altered rocks have generally higher reflectance than the unaltered rocks. 3) The ratio mesurement of pyrophyllites shows strong absorption at band 5/6 and band 6/4(in Landsat TM 5/7, 7/4). The ratio 1/5(Landsat TM 1/5) may be useful to discriminate andesite from the granite.

Management Software Development of Hyper Spectral Image Data for Deep Learning Training (딥러닝 학습을 위한 초분광 영상 데이터 관리 소프트웨어 개발)

  • Lee, Da-Been;Kim, Hong-Rak;Park, Jin-Ho;Hwang, Seon-Jeong;Shin, Jeong-Seop
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.111-116
    • /
    • 2021
  • The hyper-spectral image is data obtained by dividing the electromagnetic wave band in the infrared region into hundreds of wavelengths. It is used to find or classify objects in various fields. Recently, deep learning classification method has been attracting attention. In order to use hyper-spectral image data as deep learning training data, a processing technique is required compared to conventional visible light image data. To solve this problem, we developed a software that selects specific wavelength images from the hyper-spectral data cube and performs the ground truth task. We also developed software to manage data including environmental information. This paper describes the configuration and function of the software.

Zirconia-Alumina Composite Coating Materials for Low Temperature Process (저온 공정용 지르코니아-알루미나 복합 코팅제 연구)

  • Choi, Jongwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.1561-1567
    • /
    • 2021
  • In this study, we have studied synthesis of zirconia-alumina composite coating materials via a low-temperature sol-gel process. The zirconia-alumina composites were prepared by coating zirconia precursor, alumina precursor, and organosilane mixture on a polyethylene terephthalate substrate through three steps: sol-gel process, low-temperature photocuring process, and heat treatment process. The structural properties and element analysis of the composites were confirmed by FT-IR and XPS. The coated composite showed a transmittance of 96% or more in the visible light region with a wavelength of 420 nm or more and pencil hardness of 9H or more. In case of the composite of the molar ratio of zirconia and alumina of 1:4, the highest nanoindentation hardness was measured with 1.212 GPa.

Fabrication of an Automatic Color-Tuned System with Flexibility Using a Dry Deposited Photoanode

  • Choi, Dahyun;Park, Yoonchan;Lee, Minji;Kim, Kwangmin;Choi, Jung-Oh;Lee, Caroline Sunyong
    • International Journal of Precision Engineering and Manufacturing-Green Technology
    • /
    • v.5 no.5
    • /
    • pp.643-650
    • /
    • 2018
  • A self-powered electrochromic device was fabricated on an indium tin oxide-polyethylene naphthalate flexible substrate using a dye-sensitized solar cell (DSSC) as a self-harvesting source; the electrochromic device was naturally bleached and operated under outdoor light conditions. The color of the organic electrochromic polymer, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate, was shifted from pale blue to deep blue with an antimony tin oxide film as a charge-balanced material. Electrochromic performance was enhanced by secondary doping using dimethyl sulfoxide. As a result, the device showed stable switching behavior with a high transmittance change difference of 40% at its specific wavelength of 630 nm for 6 hrs. To improve the efficiency of the solar cell, 1.0 wt.% of Ag NWs in the photoanode was applied to the $TiO_2$ photoanode. It resulted in an efficiency of 3.3%, leading to an operating voltage of 0.7 V under xenon lamp conditions. As a result, we built a standalone self-harvesting electrochromic system with the performance of transmittance switching of 29% at 630 nm, by connecting with two solar cells in a device. Thus, a self-harvesting and flexible device was fabricated to operate automatically under the irradiated/dark conditions.

Performance of Continuous-wave Coherent Doppler Lidar for Wind Measurement

  • Jiang, Shan;Sun, Dongsong;Han, Yuli;Han, Fei;Zhou, Anran;Zheng, Jun
    • Current Optics and Photonics
    • /
    • v.3 no.5
    • /
    • pp.466-472
    • /
    • 2019
  • A system for continuous-wave coherent Doppler lidar (CW lidar), made up of all-fiber structures and a coaxial transmission telescope, was set up for wind measurement in Hefei (31.84 N, 117.27 E), Anhui province of China. The lidar uses a fiber laser as a light source at a wavelength of $1.55{\mu}m$, and focuses the laser beam on a location 80 m away from the telescope. Using the CW lidar, radial wind measurement was carried out. Subsequently, the spectra of the atmospheric backscattered signal were analyzed. We tested the noise and obtained the lower limit of wind velocity as 0.721 m/s, through the Rayleigh criterion. According to the number of Doppler peaks in the radial wind spectrum, a classification retrieval algorithm (CRA) combining a Gaussian fitting algorithm and a spectral centroid algorithm is designed to estimate wind velocity. Compared to calibrated pulsed coherent wind lidar, the correlation coefficient for the wind velocity is 0.979, with a standard deviation of 0.103 m/s. The results show that CW lidar offers satisfactory performance and the potential for application in wind measurement.

Enhanced Light Transmittance of Densely Packed Metal Nanoparticle Layers (밀집된 금속 나노 입자 레이어의 광학 특성)

  • Jeon, Hyunji;Choi, Jinnil
    • Korean Journal of Materials Research
    • /
    • v.30 no.12
    • /
    • pp.701-708
    • /
    • 2020
  • Irradiation of the metal nanoparticles causes local plasmon resonance in a specific wavelength band, which can improve the absorption and scattering properties of a structure. Since noble metal nanoparticles have better resonance effects than those of other metals, it is easy to identify plasmonic reactions and this is advantageous to find the optical tendency. Compared to having a particle gap or randomly arranged particle structures, densely and evenly packed structures can exhibit more uniform optical properties. Using the uniform properties, the structure can be applied to optical filtering applications. Therefore, in this paper, validation tests about metal nanoparticles and thin film structures are conducted for more accurate analysis. The optical properties of monolayer and bilayer noble metal nanoparticle structures with different diameters, packed in a uniform array, are investigated and their optical trends are analyzed. In addition, a thin film structure under identical conditions as metal nanoparticle structure is evaluated to confirm the improved optical characteristics.

Development of a Real-time Medical Imaging System Combined with Laser Speckle Contrast Imaging and Fluorescence Imaging (형광과 레이저 스펙클 대조도 이미징을 결합한 실시간 의료영상 시스템 개발)

  • Shim, Min Jae;Kim, Yikeun;Ko, Taek Yong;Choi, Jin Hyuk;Ahn, Yeh-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.116-124
    • /
    • 2021
  • It is important to differentiate between the target tissue (or organ) and the rest of the tissue before incision during surgery. And when it is necessary to preserve the differentiated tissues, the blood vessels connected to the tissue must be preserved together. Various non-invasive medical imaging methods have been developed for this purpose. We aimed to develop a medical imaging system that can simultaneously apply fluorescence imaging using indocyanine green (ICG) and laser speckle contrast imaging (LSCI) using laser speckle patterns. We designed to collect images directed to the two cameras on a co-axial optical path and to compensate equal optical path length for two optical designs. The light source used for fluorescence and LSCI the same 785 nm wavelength. This system outputs real-time images and is designed to intuitively distinguish target tissues or blood vessels. This system outputs LSCI images up to 37 fps through parallel processing. Fluorescence for ICG and blood flow in animal models were observed throughout the experiment.

Comparison of shrinkage according to thickness of photopolymerization resin for 3D printing (3D 프린팅용 광 중합 수지의 두께에 따른 수축 비교)

  • Kim, Dong-Yeon;Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.43 no.1
    • /
    • pp.1-5
    • /
    • 2021
  • Purpose: To perform a comparative study on curing shrinkage according to the thickness of photopolymerization resin. Methods: Stainless steel molds of 2, 4, and 6 mm heights were prepared. The 2, 4, and 6 mm-height molds were classified as the 2H, 4H, and 6H groups, respectively. A photopolymerization resin was injected into the stainless steel mold. Photopolymerization was carried out using a photopolymer machine. During photopolymerization, the wavelength and intensity of 400~405 nm were set to 10, the highest intensity among 1~10. Photopolymerization was performed for 30 min per specimen (each group=10). The inner and outer areas of the specimen were measured. The data were analyzed using one-way ANOVA and Kruskal-Wallis H test (α=0.05). Results: In terms of the inner and outer diameters of the photopolymerization resin specimen, the 2H group contracted the most, whereas the 6H group contracted the least. A statistically significant difference was found between the groups (p<0.05). Conclusion: The amount of light irradiation of the photopolymerization resin must be adjusted according to the thickness.