DOI QR코드

DOI QR Code

Comparison of shrinkage according to thickness of photopolymerization resin for 3D printing

3D 프린팅용 광 중합 수지의 두께에 따른 수축 비교

  • Kim, Dong-Yeon (4RD Dental Laboratory) ;
  • Kim, Jae-Hong (Department of Dental Laboratory Science, College of Health Science, Catholic University of Pusan)
  • 김동연 (폴드 치과기공소) ;
  • 김재홍 (부산가톨릭대학교 보건과학대학 치기공학과)
  • Received : 2021.02.16
  • Accepted : 2021.03.08
  • Published : 2021.03.30

Abstract

Purpose: To perform a comparative study on curing shrinkage according to the thickness of photopolymerization resin. Methods: Stainless steel molds of 2, 4, and 6 mm heights were prepared. The 2, 4, and 6 mm-height molds were classified as the 2H, 4H, and 6H groups, respectively. A photopolymerization resin was injected into the stainless steel mold. Photopolymerization was carried out using a photopolymer machine. During photopolymerization, the wavelength and intensity of 400~405 nm were set to 10, the highest intensity among 1~10. Photopolymerization was performed for 30 min per specimen (each group=10). The inner and outer areas of the specimen were measured. The data were analyzed using one-way ANOVA and Kruskal-Wallis H test (α=0.05). Results: In terms of the inner and outer diameters of the photopolymerization resin specimen, the 2H group contracted the most, whereas the 6H group contracted the least. A statistically significant difference was found between the groups (p<0.05). Conclusion: The amount of light irradiation of the photopolymerization resin must be adjusted according to the thickness.

Keywords

References

  1. Kim DY, Kim JH, Lee BI, Lee JH, Kim WS, Park JY. Accuracy evaluation of dental model scanner according to occlusal attrition type. J Tech Dent. 2020;42:313-320. https://doi.org/10.14347/jtd.2020.42.4.313
  2. Kim DY, Kim JH, Kim HY, Kim WC. Comparison and evaluation of marginal and internal gaps in cobalt-chromium alloy copings fabricated using subtractive and additive manufacturing. J Prosthodont Res. 2018;62:56-64. https://doi.org/10.1016/j.jpor.2017.05.008
  3. van Noort R. The future of dental devices is digital. Dent Mater. 2012;28:3-12. https://doi.org/10.1016/j.dental.2011.10.014
  4. Azari A, Nikzad S. The evolution of rapid prototyping in dentistry: a review. Rapid Prototyp J. 2009;15:216-225. https://doi.org/10.1108/13552540910961946
  5. Lee BI, You SG, You SM, Kim JH. Comparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer. J Tech Dent. 2020;42:334-340. https://doi.org/10.14347/jtd.2020.42.4.334
  6. Kim DY. Difference between shrinkage rate of irradiation amount of 3D printing UV curable resin and shrinkage rate according to a constant temperature water bath. J Korean Acad Dent Technol. 2020;42:113-120. https://doi.org/10.14347/KADT.2020.42.2.113
  7. Sa MW, Kim JY. Comparison analysis and fabrication of Hollow Shaft scaffolds using polymer deposition system. Tissue Eng Regen Med. 2015;12:46-52. https://doi.org/10.1007/s13770-015-0417-4
  8. Park YD, Kang W. Comparative analysis of the flexural strength of provisional restorative resins using a digital light processing printer according to the post-curing method. J Tech Dent. 2020;42:341-347. https://doi.org/10.14347/jtd.2020.42.4.341
  9. Prpic V, Slacanin I, Schauperl Z, Catic A, Dulcic N, Cimic S. A study of the flexural strength and surface hardness of different materials and technologies for occlusal device fabrication. J Prosthet Dent. 2019;121:955-959. https://doi.org/10.1016/j.prosdent.2018.09.022
  10. Park DR, Son J. Comparison between mechanical properties and biocompatibility of experimental 3D printing denture resins according to photoinitiators. J Tech Dent. 2020;42:355-361. https://doi.org/10.14347/jtd.2020.42.4.355
  11. Kim JH, Kim KB. Analysis of the quality of dental prostheses printed by digital light-processing technology. J Tech Dent. 2020;42:197-201. https://doi.org/10.14347/JTD.2020.42.3.197
  12. Kang SY, Lee HN, Kim EB, Lee KE, Kim JH, Kim WC. Fitness of heat - pressed ceramic laminate veneer using additive manufacturing process: 3 dimensional analysis. J Korean Acad Dent Technol. 2017;39:137-143.
  13. Kim DY, Jeon JH, Kim JH, Kim HY, Kim WC. Reproducibility of different arrangement of resin copings by dental microstereolithography: evaluating the marginal discrepancy of resin copings. J Prosthet Dent. 2017;117:260-265. https://doi.org/10.1016/j.prosdent.2016.07.007
  14. International Organization for Standardization. Dentistry - polymer-based filling, restorative and luting materials. 3rd ed. Geneva: International Organization for Standardization; 2000.
  15. Bae S, Lee J, Ra J. Evaluation of the changes in polymerization of TheraCal LC with various light-curing time and distance. J Korean Acad Pediatr Dent. 2019;46:392-399.
  16. ASTM International. ASTM C326-09 (2018), standard test method for drying and firing shrinkages of ceramic whiteware clays. West Conshohocken (PA): ASTM International; 2009.
  17. Do HS, Kim DJ, Kim HJ. Application of UV-curable materials. JAI. 2003;4:41-51.
  18. Jassim ZM, Majeed MA. Comparative evaluation of the fracture strength of monolithic crowns fabricated from different all-ceramic CAD/CAM materials (an in vitro study). Biomed Pharmacol J. 2018;11:1689-1697. https://doi.org/10.13005/bpj/1538
  19. Spear F, Holloway J. Which all-ceramic system is optimal for anterior esthetics? J Am Dent Assoc. 2008;139 Suppl: 19S-24S. https://doi.org/10.14219/jada.archive.2008.0358
  20. Karalekas D, Aggelopoulos A. Study of shrinkage strains in a stereolithography cured acrylic photopolymer resin. J Mater Process Technol. 2003;136:146-150. https://doi.org/10.1016/S0924-0136(03)00028-1
  21. Park JH, Choi NS. Polymerization shrinkage distribution of a dental composite during dental restoration observed by digital image correlation method. Compos Res. 2017;30:393-398. https://doi.org/10.7234/COMPOSRES.2017.30.6.393
  22. Kwon Y, Cho UR. Study on the improvement of film shrinkage in UV-curing process. Polymer(Korea). 2011;35:320-324.