• Title/Summary/Keyword: lid material

Search Result 40, Processing Time 0.029 seconds

Retrograde filling with Lid technique in periapical surgery: case report (Lid technique을 활용하여 치근단 수술에서 역충전을 시행한 증례 보고)

  • Yoon-Joo Lee;Kyung-Mo Cho;Se-Hee Park;Yoon Lee;Jin-Woo Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.45-51
    • /
    • 2023
  • Apical sealing with proper retrograde filling material and technique is the key factor for successful apical surgery. In order to provide impeccable apical sealing and healing, various mechanical and chemical characteristics of retrograde filling material is required. MTA has been used as the gold standard of retrograde filling due to its unprecedented advantages. As MTA has long setting time and difficult handling properties, premixed putty type bioceramic material has been newly developed. For efficient retrofilling with premixed putty type biocreamic material, 'Lid technique' was also proposed. The following cases present apical surgery using newly developed premixed putty type bioceramic material with Lid technique.

The Sectional Analysis of Trunk-lid using the Equilibrium Approach and Three-Dimensional Shape Composition (평형해법을 이용한 트렁크 리드의 단면해석과 3차원 형상합성)

  • 정동원
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.66-71
    • /
    • 2001
  • A sectional analysis of trunk-lid carried out by using the equilibrium approach based on the force balance together with geometric relations and plasticity theory. In computing a force balance equation, it is required to define a geometric curve approximating the shape of sheet metal at any step of deformation from the interaction between the die and the deformed sheet. The trunk-lid panel material is assumed to possess normal anisotropy and to obey Hill's new yield criterion. Deformation of each section of trunk-lid panel is simulated and composed to get the three-dimensional shape by using CAD technique. It was shown that the three-dimensional shape composition of the two-dimensional analysis.

  • PDF

The Analysis of Runoff Characteristics by Alterations of SCS-CN Value using LID Method (LID 기법 적용에 의한 SCS-CN값 변화가 강우유출특성에 미치는 영향 분석)

  • Kwon, Jun-Hee;Park, In-Hyeok;Ha, Sung-Ryoung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.49-57
    • /
    • 2010
  • The objective of the research is to analyze changing trend of water discharge in precipitation, according to changing land use, through an environment-friendly urban development method called LID. The study chose S1 basin (Separated Sewer districts) in Cheongju region for survey. Among LID methods, relatively more applicable methods of green rooftop space and parking lot with permeable material were selected to construct plausible scenarios. Curve Number (CN) value was calculated due to land use patterns in each scenario, and SWMM model simulation were conducted during 2008 for comparative analysis. For Case 1, only parking lot with permeable material was applied to the scenario. Green rooftop space I and II were applied to Case 2 and 3 respectively. For Case 4 and 5, green rooftop space I and II were applied, in addition to parking lot with permeable material, Calculation of CN value showed that for S1 basin, the value was 88.1 (prior to scenario application), 86.5 (Case 1), 81.9 (Case 2), 68.5 (Case 3), 80.4 (Case 4) and 67.2 (Case 5). Changing pattern of rain water discharge was analyzed for each scenario. For Case 1, the change was not remarkable before and after application of scenario. In Case 2 and 4, the impact of rain water discharge as source of pollutant fell to 20~30%. The rate dropped to 30~50% in Case 3 and 5 respectively. The result demonstrates that the amount of rain water discharge, amount and frequency of sewer overflow, frequency of rain water discharge, and pollution load decreased in accordance with declining CN value in each scenario. In installing green rooftop space, the effect was twice greater when rain water discharge was directly infiltrated into soil.

Assessment of Performances of Low Impact Development (LID) Facilities with Vegetation (식생이 조성된 LID 시설의 효율 평가)

  • Hong, Jung Sun;Kim, Lee-Hyung
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.100-109
    • /
    • 2016
  • Low impact development (LID) facilities are established for the purpose of restoring the natural hydrologic cycle as well as the removal of pollutants from stormwater runoff. Improved efficiency of LID facilities can be obtained through the optimized interaction of their major components (i.e., plant, soil, filter media, microorganisms, etc.). Therefore, this study was performed to evaluate the performances of LID facilities in terms of runoff and pollutant reduction and also to provide an optimal maintenance method. The monitoring was conducted on four LID technologies (e.g., bioretention, small wetlands, rain garden and tree box filter). The optimal SA/CA (facility surface area / catchment area) ratio for runoff reduction greater than 40% is determined to be 1 - 5%. Since runoff reduction affects the pollutant removal efficiency in LID facilities, SA/CA ratio is derived as an important factor in designing LID facilities. The LID facilities that are found to be effective in reducing stormwater runoff are in the following order: rain garden > tree box filter > bioretention> small wetland. Meanwhile, in terms of removal of particulate matter (TSS), the effectiveness of the facilities are in the following order: rain garden > tree box filter > small wetland > bioretention; rain gardens > tree box filter > bioretention > small wetland were determined for the removal of organic matter (COD, TOC), nutrients (TN, TP) and heavy metals (Cu, Pb, Cd, Zn). These results can be used as an important material for the design of LID facilities in runoff volume and pollutant reduction.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

Analysis on the Water Circulation and Water Quality Improvement Effect of Low Impact Development Techniques by Test-Bed Monitoring (시범 단지 운영을 통한 LID 기법별 물순환 및 수질개선 효과 분석)

  • Ko, Hyugbae;Choi, Hanna;Lee, Yunkyu;Lee, Chaeyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.27-36
    • /
    • 2016
  • Low Impact Development (LID) techniques are eco-friendly storm water management process for water circulation restoration and non-point pollutant reduction. In this study, four LID techniques (Small constructed wetland, Infiltration trench box, Infiltration trench, Vegetated swale) were selected and installed as a real size at the real site. All facilities were evaluated as monitoring under the real environmental climate situation and an artificial rain with exceeding design rainfall. In various rainfall, runoff reduction efficiency and non-point pollutant removal efficiency are increased to the bigger Surface Area of LID (SA)/Catchment Area (CA) ratio and the bigger Storage Volume of LID (SV)/Catchment Area (CA) ratio. Runoff did not occur at all rainfall event (max. 17.2 mm) in infiltration trench and vegetated swale. But Small constructed wetland was more efficient at less than 10 mm, a efficiency of infiltration trench box was similar at different rainfall. Although different conditions (such as structural material of LID, rainfall flow rate, antecedent dry periods), LID techniques are good effects not only water circulation improvement but also water quality improvement.

Correction of Lower Eyelid Retraction with Autogenous Hard Palate Mucosa: 2 Case Report (자가 경구개점막 이식을 이용한 하안검 퇴축의 교정: 2례 보고)

  • Kim, Jino;Seul, Chul Hwan;Roh, Tae Suk;Yoo, Woon Min
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.499-502
    • /
    • 2006
  • Purpose: Grave's disease is an autoimmune disease with chronic and systemic features. It affects the orbital fat and muscle bringing about defect in extrinsic eye motility, diplopia, optic nerve defect and lid retraction. In patients with lagopthalmos and resulting facial deformity, treatment can be done by rectus muscle recession or filling with various material. Autogenous auricular cartilage graft is often used and synthetic material such as synthetic acellular dermis, polyethylene meshs are also used for filling of the depressed area. Nevertheless, autogenous auricular cartilage grafts are difficult to utilize and synthetic materials sometimes result in protrusion or infection. Therefore, hard palate mucosa was considered as an alternative. We report two cases of patients with lower eyelid retraction corrected with autogenous hard palate mucosa. Methods: We performed this operation in two patients of Graves' ophthalmopathy. The capsulopalpebral fascia was incised and elevated through an incision on the conjunctiva. Then, the harvested hard palate mucosa was sutured to the inferior border of the tarsus and covered with the conjunctiva. Results: The lower eyelid retraction was corrected successfully. No hypertrophy or deformation of the transplanted hard palate mucosa was noted 6 months after the surgery. Conclusions: From the results above, we may conclude that the hard palate mucosa serves as an ideal spacer for the curvature and the inner lining in lower lid retraction. Hard palate mucosa is as sturdy as the autogenous cartilage but is much easier to utilize. It can be also used for lid retraction after lower lid aesthetic surgeries or traumas.

Assessment of Salt Resistance and Performances of LID Applicable Plants (LID시설에 적용된 식물의 염분 저항성 및 효과 평가)

  • Choi, Hyeseon;Hong, Jungsun;Lee, Soyung;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.201-207
    • /
    • 2016
  • In LID facilities treating stormwater runoff, various kinds of plants are applied for water circulation recovery and pollutant reduction. However, rapid changes of soil moisture due to the use of porous media and spread of deicing material during winter season cause slow plant growth that detrimentally leads to many problems including death of plants. Therefore, this study was performed to evaluate the salt resistance of plants, its effects on pollutants removal, and water circulation recovery. Eight different kinds of plants applicable to an LID facility were selected for the experiment, which were Bridal wreath (Spiraea japonica, S.J), Azalea (Rhododendron indicum, R.I), Dawn Redwood (Metasequoia glyptostroboides, M.G), Sweet flag (Acorus calamus A.C), Dwarf fan-shape columbine(Aquilegia flabellata, A.F), Pink (Dianthus chinensis, D.C), Pratia pedunculata (Pratia pedunculata, P.B) and Marigold (Tagetes patula, T.P). Woody plants such as S.P, R.I, and M.G appear to have less salt resistance compared to the other herbaceous plants. Specifically, M.G achieved the highest salt resistance among the other woody plants being followed by S.P, and R.I, respectively. For herbaceous plants, T.L and D.C have the higher salt resistances than that of A.C, P.B, and A.F, respectively. Regardless of the influence of salt to most of the plants, TN and TP were reduced more than 60% and the study suggests the M.G showed high pollutant removal efficiency and provided better water circulation by means of active photosynthesis and respiration due to higher growth.

Effects of Vegetation on Pollutants and Carbon Absorption Capacity in LID Facilities (LID시설에서의 오염물질 및 탄소흡수능에 식생이 미치는 영향)

  • Hong, Jin;Kim, Yuhyeon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.2
    • /
    • pp.115-122
    • /
    • 2022
  • As the impermeable area of soil increases due to urbanization, the water circulation system of the city is deteriorating. The existing guidelines for low impact development (LID) facilities installed to solve these water problems or in previous studies, engineering aspects are more prominent than landscaping aspects. This study attempted to present an engineering and landscaping model for reducing pollutants by identifying the effects of vegetation on rainfall outflows and pollutant reduction in bioretention and the economic aspects of planting. Based on the results of artificial rainfall monitoring at Jeonju Seogok Park and the literature on vegetation rainfall runoff and pollutant reduction performance, the best vegetation for reducing pollution compared to cost was Lythrum salicaria L and Salix gracilistyla Miq. was the best vegetation for carbon storage. If you insist to design plants with only these two plantation, there is no choice but to take risks such as biodiversity. Herbaceous plants such as Lythrum salicaria L can be replaced by death of the plants or pests if considered planting various plants. The initial planting cost could expensive, but it is also necessary to mix and plant Salix gracilistyla Miq, which are woody plants that are advantageous in terms of maintenance, according to the surrounding environment and conditions. Based on the conclusions drawn in this study, it can be a reference material when considering the reduction of pollution by species and carbon storage of vegetation in LID facilities.

A Study on the Development of Friction Hinge with Automatic Closed Function (자동 닫힘 기능을 갖는 마찰힌지 개발에 관한 연구)

  • Ye, Sang-Don;Min, Byeong-Hyeon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • A friction hinge system which moves without power was designed and developed using the principle of friction force, which is caused by interference between the inner diameter of a silicon cap and the outer diameter of a cylindrical roller bearing with one-way rotation in a counterclockwise direction. The system was applied to the lid of buffet ware, which moved up by external force and moved down by gravitational force. However, design conditions which included a rotation angle of the hinge of more than 80 degrees and a closing time of more than 20 seconds were required when the lid of the buffet ware closed due to gravitational force. The design safety of the friction hinge body connected to the lid of the buffet ware from the hinge system was checked on the basis of structural, fatigue and thermal analyses. The material of the shaft, cap and flange among the hinge elements was changed to polyethylene from steel to reduce the weight of the friction hinge system. An injection molding simulation was performed and injection molds of the shaft, cap and flange were created. The weight of the hinge system was decreased from 805g to 219g.