• Title/Summary/Keyword: length variation test

Search Result 289, Processing Time 0.031 seconds

Development of Severity-Adjustment Model for Length of Stay in Hospital for Percutaneous Coronary Interventions (관상동맥중재술 환자의 재원일수 중증도 보정 모형 개발)

  • Nam, Mun-Hee;Kang, Sung-Hong;Lim, Ji-Hye
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.372-383
    • /
    • 2011
  • Our study was carried out to develop the severity-adjustment model for length of stay in hospital for percutaneous coronary interventions so that we would analysis the factors on the variation in length of stay(LOS). The subjects were 1,011 percutaneous coronary interventions inpatients of the Korean National Hospital Discharge In-depth Injury Survey 2004-2006 data. The data were analyzed using t-test and ANOVA and the severity-adjustment model was developed using data mining technique. After yielding the standardized value of the difference between crude and expected length of stay, we analysed the variation of length of stay for percutaneous coronary interventions. There was variation of LOS in regional differences, size of sickbed and insurance type. The variation of length of stay controlling the case mix or severity of illness can be explained the factors of provider. This supply factors in LOS variations should be more studied for individual practice style or patient management practices and healthcare resources or environment. We expect that the severity-adjustment model using administrative databases should be more adapted in other diseases in practical.

Analysis of Frequency Response Depending on Wire-bonding Length Variation (Wire-bonding의 길이 변화에 따른 주파수별 특성 분석)

  • Gwon, Eun-Jin;Mun, Jong-Won;Ryu, Jong-In;Park, Se-Hoon;Kim, Jun-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.551-552
    • /
    • 2008
  • This paper presets a results of frequency response in variation of wire bonding length. A gold ball bonding is used as a wire bonding process, and a DPDT(double pole double thru) switch is adapted as a device for test. Wire length is ranged from 442um to 833um and a measured frequency range is from 1 GHz to 6 GHz. Little difference are measured in insertion loss and return loss depending on wire length. Measured S21 and S11 are -0.58 dB and -17.7 dB, respectively. S21 insertion loss is rising up and S11 insertion loss is falling down as the frequency is increased.

  • PDF

A Development of Pulley-type Tensioning Device for a High Speed Railway (고속용 풀리형식 장력조정장치 개발)

  • Cho, Yong-Hyeon;Kwon, Sam-Young;Park, Young;Lee, Ki-Won
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.723-730
    • /
    • 2006
  • In the electrical railway, the tension ascension of contact wire is essential to speed up of train and current collection performance of catenary largely depends on the tension. The tension variation rate of the tensioning device used in existing line limits within 5%, and the tension variation rate of the spring-type tensioning device installed at the section where tensioning length is short bounds within 15%. So it is urgent for us to localize it for high speed line, which the tension variation rate is limited within 3%. Therefore in this study, a pulley-type tensioning device for high speed line is developed. To verify the performance of developed device, a performance test, overload test and failure test is carried out under the code of the Kyung-Bu High Speed line. And it is secured durability performance through a fatigue test.

  • PDF

Thermal Response Property of Grout Materials from In-situ Test and Temperature Variation of Ground Heat Exchanger (그라우트 재료별 열응답 특성 및 열교환기 운전온도 변화)

  • Kim, Kap-Duk;Lee, Soung-Ju;Yun, Yeo-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.769-775
    • /
    • 2008
  • The objective of this report is to determine the difference of thermal response that grouted two different materials, and compare the simulation result of the length of total ground heat exchanger length that using the ground thermal conductivity. And also to know heat exchange variation of ground heat exchanger temperature that measured with various test depth. The result shows that the test hole grouted with water permeable material got better thermal response than grouted with water impermeable material. However, with consideration of ingnore for the initial 12 hour data, the test hole grouted with impermeable material has larger thermal conductivity than the other. By former thermal conductivity, simulated data by engineering program shows only 3.4% difference or less. This result shows that ground thermal conductivity is not the main variables for the design program of ground heat exchanger. At the cooling or heating mode, base on the depth of -150m, the ground heat exchanger has best temperature at $-90{\sim}-60m$ and than getting worse because of entering water heat exchanged with leaving water in the same hole.

  • PDF

Emission Characteristics of LP Gas Burner for the Variation of Combustion Conditions (연소조건 변화에 따른 LP가스버너의 배기특성)

  • 이병곤;오택흠
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • An experimental study was carried out to investigate the emission characteristics of LP gas burner for the Practical combustion conditions including fm voltage, inlet area, gas Pressure, emission resistance, duct length and height. The result shows that CO is almost remains constant for the emission fan voltage, but significantly increases with the reduction rate of air inlet, up to 3000ppm at 50% of reduction rate. Also, the variation of gas pressure has no effect to CO of gas boiler due to its governor which controls gas pressure secondly, but it gives an rapid increase of CO for the gas range. The emission resistance test shows that CO is suddenly increased with the reduction rate of emission duct above 70% and main burner is stopped at 90%. The reverse wind test shows that CO is suddenly increased with the air velocity above 7m/s and main burner is stopped at 9m/s. The more horizontal length of emission duct is long and the vertical height is low, CO is infinitesimally increased.

  • PDF

Reliability of Measured Popliteal Angle by Traditional and Stabilized Active-Knee-Extension Test

  • Kim, Min-Hee;Kim, Yong-Wook;Jung, Doh-Heon;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • The active-knee-extension (AKE) test has been used to measure hamstring muscle length. The traditional AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip fixed by straps, while the stabilized AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip stabilized using a pressure biofeedback unit providing lumbopelvic stabilization. The purpose of this study was to determine test-retest reliability of the traditional AKE test and stabilized AKE test. Twenty healthy adults participated in the study. The popliteal angles were measured with a digital inclinometer during each test. To assess the test-retest reliability between the 2 test sessions, intraclass correlation coefficients (ICCs) were calculated. The intrasubject coefficient of variation ($CV_{intra}$) was also calculated. To compare the traditional and stabilized AKE tests for changes in pressure, paired t-tests were applied. The results of this study were as follows: 1) ICCs(3,1) value for test-retest reliability was .96 in the traditional AKE test, and was .98 in the stabilized AKE test. 2) The maximal $CV_{intra}$ was 33.7% in the traditional AKE test and 15.7% in the stabilized AKE test. 3) Differences of $6.1{\pm}2.1$ mmHg in pressure were measured in the traditional AKE test, and differences of $1.2{\pm}1.0$ mmHg in pressure were measured in the stabilized AKE test. The results show the traditional and stabilized AKE test to be highly reliable, with test-retest reliability. However, the stabilized AKE test represented less variation and more stabilization than the traditional AKE test. Further study is needed to measure the inter-rater reliability of the stabilized AKE test for generalization and clinical application.

  • PDF

Somatotype Characteristics of Elementary School Girls (Part I) -Focusing somatotype changing charcteristics on each grade group- (학령기 여아의 체형 특성(제1보) -학령기별 체형 변이 특성을 중심으로-)

  • 장정아;권영숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.7
    • /
    • pp.941-952
    • /
    • 1999
  • The purposes of this study were to provide the fundamental data on elementary school girls' somatotype for their clothing construction by contemplating the stage of physical growth dividing into the period of school age and characterizing the variation of body type according to the school age. The results are as follows : 1. Form the results of one-way variables analysis and multiple comparson test(Duncan's test) classification of the period school age can be divided into 'early grade(1 2 grade)' ' middle grade(3 4 grade)' and 'later grade(5 6 grade)' 2. As the results of analyzing Mean Coefficient of Variation and Standard Deviation graph for direct and indirect measurments and index especially of the Coefficient Variation that explain individual difference of growth the items of height indicates individual difference related with height of lower body of early grade group the items of length individual difference related with length of upper body of later grade group and the items of circumference make little difference. The items of anagle makes pretty higher value that direct measurements and especially in lower angle of chest make a distinctive difference, This fact proves that children's somatotype change from the belly part extruded forwards of early and middle grade to the upper body part slanted slightly forward of later grade.

  • PDF

Effects of Stressed and Unstressed Reinforcements on Prestressed Concrete Members with Unbonded Tendons

  • Moon, Jeong-Ho;Shin, Kyung-Jae;Lim, Jae-Hyung;Lee, Sun-Hwa
    • KCI Concrete Journal
    • /
    • v.12 no.1
    • /
    • pp.131-138
    • /
    • 2000
  • The research purpose of this paper is to investigate the influential Parameters on the unbonded tendon stress. The parameters were the reinforcing ratio, the prestressing ratio, and the loading type. To this end. first, the influence of parameters were examined with twenty eight test results obtained from references. Then, an experimental study was carried out with nine specimens. Test variables were the reinforcing ratio and the prestressing ratio. Specimens were divided equally into three groups and each group had a different level of the reinforcing ratio. Each specimen within a group has a different level of the prestressing ratio. The investigation with previous and current tests revealed the followings; (1) the length of crack distribution zone does not have a close relation with the length of plastic hinge. (2) the prestressing ratio does not affect both the length of crack distribution and the length of plastic hinge, (3) the tendon stress variation is in reverse relation with the ratios of mild steels and tendons, (4) the loading type nay not affect significantly the length of crack distribution zone, (5) AASHTO LRFD Code equation and Moon/Lim's design equation predicted the test results well with some safety margins.

  • PDF

Experimental study of Internal pressure variation of the TTX traveling in conventional tunnels (틸팅 열차의 터널주행 시 실내 압력변화에 대한 실험적 연구)

  • Yun, Su-Hwan;Lee, Young-Bin;Kwak, Min-Ho;Park, Hoon-Il;Kim, Kyu-Hong;Lee, Dong-Ho;Kwon, Hyeok-Bin;Ko, Tae-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2114-2119
    • /
    • 2008
  • When a train enters into a tunnel, a compression wave is generated by a front nose and a expansion wave is generated by a rear nose each other. Because the compression wave and expansion wave have interactions with the train in a tunnel repeatedly, the internal pressure of the train is dramatically varied. And this pressure variation gives passengers discomfort like ear-ache. In this paper, we had measured the internal pressure variation of TTX developed and being on Test-Running in Honam line and made an analysis of pressure variation rate. As a result, the internal pressure variation was different as to the length of tunnel. Though the entering velocity of TTX is similar on test tunnels, on the short tunnel, the pressure drop was lower then that of the long tunnel. And it was expected that the rates of internal pressure variation would be exceeded the limits on 160km/h entering velocity.

  • PDF

Satisfaction with the Somatotype & Fit of Overweight Women's Ready-to-wear (의복설계를 위한 비만여성의 기성복 만족도)

  • Kim, Hee-Sook
    • Fashion & Textile Research Journal
    • /
    • v.8 no.1
    • /
    • pp.64-70
    • /
    • 2006
  • The purpose of this study is to investigate the somatotype variation & satisfaction with the fit of ready-to-wear for overweight women. For this study, questionnaires were administered to 154 overweight women in Andong & Daegu areas. Employing a sample of 116 data were analyzed by using F-test. And 10 overweight women's brands were analyzed for sizing system of women's ready-to-wear. The results were as follows: In the satisfaction with the somatotype variation of overweight women, length items increased and girth items decreased with aging. At neck, bust, waist, hip and sleeve circumferences, satisfaction with the fit of ready-to-wear decreased with aging. Correlation for somatotype variation & satisfaction with the fit of ready-to-wear was significantly positive. And main sizing system of overweight women' s ready-to-wear brands was size 99 & 105 cm(bust)-90 cm (waist)-110 cm(hip), and its sizing intervals was almost existed in range of 5 cm-7 cm. There were various sizing systems in overweight women's ready-to-wear brands, and it raised a problem of consumer's dissatisfaction.