• Title/Summary/Keyword: leakage test

검색결과 1,008건 처리시간 0.024초

GaAs MESFET의 온도변화에 다른 게이트 누설전류 특성 (Gate Leakage Current Characteristics of GaAs MESFETS′ with different Temperature)

  • 원창섭;김시한;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.50-53
    • /
    • 2001
  • In this study, gate leakage current mechanism has been analyzed for GaAs MESFET with different temperatures ranging from 27$^{\circ}C$ to 300$^{\circ}C$ . It is expected that the thermionic and field emission at the MS contact will dominate the current flow. Thermal cycle is applied to test the reliability of the device. From the results, it is proved that thermal stress gradually increases the gate leakage current at the same bias conditions and leads to the breakdown and failure mechanism which is critical in the field equipment. Finally the gate contact under the repeated thermal shock has been tested to check the quality of Schottky barrier and the current will be expressed in the analytical from to associate with the electrical characteristics of the device.

  • PDF

Optimum Design of a Non-Destructive Testing System to Maximize Magnetic Flux Leakage

  • Park, G.S;Jang, P.W;Rho, Y.W
    • Journal of Magnetics
    • /
    • 제6권1호
    • /
    • pp.31-35
    • /
    • 2001
  • This paper describes the design method of a magnetic system to maximize the magnetic flux leakage (MFL) in a non-destructive testing (NDT) system. The defect signals in a MFL type NDT system mainly depend on the change of the magnetic leakage flux in the region of a defect. The characteristics of the B-H curves are analysed and a design method to define the operating point on B-H curves for maximum leakage is performed. The computed MFL signal by a nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG, the traveling detector unit in gas pipe, in an 8 inch test tube with defects. The rhombic defects could be successfully identified from the defect signals.

  • PDF

Vivadent의 변연누출에 관한 실험적 연구 (Marginal Leakage Test on 'Vivadent' Composite Resin)

  • 권혁춘
    • 대한치과의사협회지
    • /
    • 제23권12호통권199호
    • /
    • pp.1031-1037
    • /
    • 1985
  • The purpose of this study was to evaluate the marginal sealing ability of 'vivadent.' Using freshly extracted human teeth and 2% aqueous methylene blue, the marginal leakage of dye in restorative materials such as vivadent with acid etching technique, Durafill with acid etching technique, silar with acid etching technique, Adaptic, and Amalgam were investigated at 37℃ and under temperature cycling in range of 4℃-60℃. The results were as follows; 1. All filling materials showed some degree of marginal penetration by 2% methylene blue dye. 2. Vivadent with acid etching technique revealed effective marginal sealing ability, but under temperature cycling it showed increased marginal leakage. 3. All resins showed greater marginal leakage than amalgam restoration. 4. Vivadent had the most effective marginal sealing ability in experimented resins.

  • PDF

Silar(Composite Resin계)의 변연누출(變緣漏出)에 관(關)한 실험적(實驗的) 연구(硏究) (MARGINAL LEAKAGE TEST ON "SILAR" COMPOSITE RESIN)

  • 권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.167-172
    • /
    • 1982
  • The purpose of this study was to evaluate the marginal sealing ability of "Silar". Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as Silar, Silar with acid etching technique, Hi-Pol, Hi-Pol Enamel Bond system, Adaptic and Amalgam were investigated at $37^{\circ}C$ and under temperature cycling in range of $4^{\circ}C-60^{\circ}C$. The results as follows; 1. All filling materials showed some degree of marginal penetration by 2% methylene blue dye. 2. Silar with acid etching technique revealed effective marginal sealing ability, but under temperature cycling it showed increased marginal leakage. 3. All composite resins showed greater marginal leakage than amalgam restoration. 4. Silar had the most effective marginal sealing ability in experimented composite resins.

  • PDF

ZnO 바리스터에 흐르는 누설전류의 주파수 의존성 (Frequency dependences of leakage currents flowing through ZnO varistor)

  • 이복희;이봉;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2166-2168
    • /
    • 2005
  • This paper presents the frequency - dependent characteristics of leakage currents flowing through ZnO varistor. The leakage current - voltage (V-I) characteristic curves of the commercial ZnO varistor were measured. The resistive leakage current was increased with increasing the magnitude and frequency of the applied voltage in the low conduction region. The power losses of ZnO varistor increase as the frequency of applied voltage increases, because of the dielectric loss related to the frequency of the test voltage.

  • PDF

항공용 모터 조립체의 전자기 간섭 감쇠 방안 (Electromagnetic Interference Suppression Method of Motor Assembly for Aircraft Application)

  • 김지흥;유홍균;박범준;박영주
    • 한국항행학회논문지
    • /
    • 제22권5호
    • /
    • pp.351-358
    • /
    • 2018
  • 본 연구에서는 개발된 모터 조립체의 누설 잡음신호 감쇠 방안을 시험을 통해 제안한다. 개발된 장치는 항공기 외부에 장착되어 안테나를 회전시키기 위한 장치로서 전자기 간섭 측면에서 MIL-STD-461F의 RE102 요구규격을 충족해야한다. RE102 시험결과를 통해 장치의 누설 잡음신호가 전원 및 제어 케이블을 통한 외부 유입과 모터 회전에 의해 발생됨을 확인하였다. 그리고 회전을 위해 내 외부의 물리적 차폐가 어려운 부분에서 잡음신호가 누설됨을 확인하였다. 누설 잡음신호에 대한 감쇠를 위해 장치 동작을 고려한 전기적 접지 보강, 전기적 차폐 구조를 적용하여 시험을 수행했고 규격 충족 여부를 확인하였다. 최종적으로 잡음누설 경로에 맞물리는 형태를 갖는 원형 주름 초크 구조와 전도성 그리스를 함께 적용하여 요구규격을 충족함을 확인하였다.

뇌서지가 ZnO바리스터에 미치는 영향 (Effects of Lightning Surges on the Life of ZnO Varistors)

  • 이봉;이수봉;강성만;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

Post space preparation timing of root canals sealed with AH Plus sealer

  • Kim, Hae-Ri;Kim, Young Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.27-33
    • /
    • 2017
  • Objectives: To determine the optimal timing for post space preparation of root canals sealed with epoxy resin-based AH Plus sealer in terms of its polymerization and influence on apical leakage. Materials and Methods: The epoxy polymerization of AH Plus (Dentsply DeTrey) as a function of time after mixing (8, 24, and 72 hours, and 1 week) was evaluated using Fourier transform infrared (FTIR) spectroscopy and microhardness measurements. The change in the glass transition temperature ($T_g$) of the material with time was also investigated using differential scanning calorimetry (DSC). Fifty extracted human single-rooted premolars were filled with gutta-percha and AH Plus, and randomly separated into five groups (n = 10) based on post space preparation timing (immediately after root canal obturation and 8, 24, and 72 hours, and 1 week after root canal obturation). The extent of apical leakage (mm) of the five groups was compared using a dye leakage test. Each dataset was statistically analyzed by one-way analysis of variance and Tukey's post hoc test (${\alpha}=0.05$). Results: Continuous epoxy polymerization of the material with time was observed. Although the $T_g$ values of the material gradually increased with time, the specimens presented no clear $T_g$ value at 1 week after mixing. When the post space was prepared 1 week after root canal obturation, the leakage was significantly higher than in the other groups (p < 0.05), among which there was no significant difference in leakage. Conclusions: Poor apical seal was detected when post space preparation was delayed until 1 week after root canal obturation.

외기 중 미세먼지의 공동주택 실내 유입에 관한 연구 (Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings)

  • 방종일;조성민;성민기
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.

환경조건변화에 대한 실리콘애자의 누설전류 파형분석 (Waveform analysis of leakage current on silicon insulator for various environment condition variation)

  • 박재준
    • 정보학연구
    • /
    • 제7권2호
    • /
    • pp.69-76
    • /
    • 2004
  • 본 논문은 여러 가지 환경조건하(염무, 안개, 비)에서 오손된 실키콘애자의 누설전류파형과 파형의 스펙트럼 분석 결과를 나타내었다. 200ms동안 누설전류의 크기가 더욱 커지면 커질수록, 60Hz에서의 스펙트럼의 크기도 커짐을 알 수 있었다. 만일 오손된 애자들이 고밀도의 염무에 접촉되면 낮은 스펙트럼을 갖은 누설전류파형이 계측되었고, 간헐적으로 높은 파형이 계측되었다. 누설전류자료 분석의 경우, 전기적인 활동은 염무 측정시 애자표면에 누적된 오손물질로 인한 일시적인 아크거동으로 특성지어진다. 이것은 애자표면을 따라 흐르는 누설전류에 대한 경로를 제공하게 된 것이다. 그것은 특별한 애자의 퍼포먼스 측정을 평가하기위하여 오손누적의 지표를 갖은 것으로서 중요한 것이다. 만일 표면 저항의 떨어짐이 크게 되면, 그때의 누설전류는 전력품질이 저하시킨 섬락을 중단시키는 공급된 전류이 점차로 증가되어진다.

  • PDF