• Title/Summary/Keyword: leakage point

Search Result 333, Processing Time 0.033 seconds

Carrier Based LFCPWM for Leakage Current Reduction and NP Current Control in 3-Phase 3-Level Converter (3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 캐리어 기반 LFCPWM)

  • Lee, Eun-Chul;Choi, Nam-Sup
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.446-454
    • /
    • 2022
  • This study proposes a carrier-based pulse width modulation (PWM) method for leakage current reduction and neutral point (NP) current control in a three-phase three-level converter, which is a carrier-based PWM version of the previously proposed low-frequency common mode voltage PWM. Three groups of space vectors with the same common mode voltage are used. When the averaged NP current needs to be positive or negative, the specific groups are employed to produce low-frequency common mode voltages. The validity of the proposed PWM method is verified through experiments.

Characteristics of Flank and Tip Seal Leakage in a Scroll Compressor for Air-Conditioners (공기조화기용 스크롤 압축기의 플랭크 및 팁실 누설특성)

  • Youn, Young;Kim, Yong-Chan;Min, Man-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.134-143
    • /
    • 2001
  • This paper presents the characteristics of flank and tip seal leakage in a scroll compressor for air-conditioners with R-22 under actual operating conditions. It is well known that the leakage has significant effect on the performance of the scroll compressor. Experiments were performed by using indirect method for measuring mass flow rate passing through flank and tip seal under actual operating conditions, In addition, an analytical model for tip seal leakage was developed to investigate tangential and radial leakage observed at grooves and contact points of tip seals. For low oil concentration, theoretical results were compared with experimental data to verify the analytical model. As a result, leakages through flank and tip seal parts were evaluated as afunction of pressure ratio, orbiting angle, discharge pressure, tip clearance, and leakage point. It was also found that the tip seal leakage was considerable even though the tip seal provided adequate sealing effect.

  • PDF

Development of new electrical leakage detection system for waste landfil (위생매립지 누출검지 및 누출위치 파악을 위한 전극배치시스템 개발)

  • Han, Sang-Jae;Shin, Hyun-Young;Jung, Jae-Hyun;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.242-250
    • /
    • 2008
  • Lining systems are used for two purpose in landfills : as covers to minimize leachate generation and surface water contamination by providing a barrier from precipitation and other percolating waters, and as containment liners to contain leachate and minimize its downward migration into underlying groundwater. So identifying leaks in landfill liners is an essential part of waste management. There are many leakage detection systems to monitor and seek leakage location, such as two electrode method, electrode grid method, diffusion hoses, capacitance sensors and tracers sensing cables. However, most of them can be applied in the new landfill construction sites because sensors must be installed prior to work. This paper presents a new type of leakage detection system, so called fence type electrode arrangement system, to monitor leakage and to seek leakage location in working landfill as well as new landfill. This system is based on the measurement of an electrical current flowing through leakage point. Series of laboratory tests are performed to investigate an availability of this system and this paper present some of these results.

  • PDF

A Study on the Residual Leakage Field in the Surface Defect of Alloy Steel (합금강 표면결함의 잔류누설자장에 관한 연구)

  • Lee, I.S.;Park, U.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.22-29
    • /
    • 1989
  • The important point of MPI is the analysis of leakage field in the defective regions. The analysis of leakage field depends on many factors such like geometry and character of defect. In general the calculation of magnetic leakage fields arising from such defects presents an extremely complicated mathematical problem and is practically insoluable, since the inhomogeneities have complex geometrical shapes and may differ in physical nature. Therefore, this paper describes Hall probe measurements of residual leakage field around artificial flaws in alloy steel bar, and shows how the results to recent developments in 2D dipole and analytic models of the magnetic field defect interaction.

  • PDF

Leakage Current Reduction by a New Combination of PWM Method and Modified connection for 3-level Inverter Photovoltaic PCS (3상 3레벨 태양광 PCS에서 누설전류 저감 기법)

  • Seng, Chhaya;Jo, Jongmin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.346-347
    • /
    • 2020
  • This paper presents the two combination methods for leakage current reduction in photovoltaic system PCS. The leakage current in the photovoltaic system generated from the parasitic capacitance existing between the photovoltaic system and ground relevance to common mode voltage caused by PWM switching. Firstly, Leakage current reduced by a PWM method using two carriers with 180-degree phase different. Secondly, the leakage current is more reduced by connecting LCL filter to the mid-point of DC link. This combining method is revealed in PSIM simulation with 1 uF parasitic capacitance.

  • PDF

Modified Electrical Resistivity Survey and its Interpretation for Leakage Path Detection of Water Facilities (수변구조물의 누수 경로 탐지를 위한 변형된 전기비저항 탐사 및 자료 해석)

  • Lee, Bomi;Oh, Seokhoon
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.4
    • /
    • pp.200-211
    • /
    • 2016
  • To support cross potential array and direct potential array, the array for leakage detection of all kinds of water facilities is proposed and it is named as the D-Lux array. The D-Lux array data are arranged to a coloured matrix and it is called the D-Lux view. Low potential difference of anomalous zone shown in D-Lux view implies the indication of leakage zone. Furthermore, for an intuitive interpretation of D-Lux array, equipotential distribution map is made by using D-Lux and direct potential array data. Equipotential distribution map makes us possible to predict import point, export point and the path of water leakage that we could have not anticipated in D-Lux view and the graphs. The water tank experiment and numerical analysis were carried out as preparatory experiment and the field explorations were conducted at a concrete weir and a fill dam. As a result, effective and specific detection of leakage path was possible for the concrete weir and the fill dam.

Classification of Grid Connected Transformerless PV Inverters with a Focus on the Leakage Current Characteristics and Extension of Topology Families

  • Ozkan, Ziya;Hava, Ahmet M.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.256-267
    • /
    • 2015
  • Grid-connected transformerless photovoltaic (PV) inverters (TPVIs) are increasingly dominating the market due to their higher efficiency, lower cost, lighter weight, and reduced size when compared to their transformer based counterparts. However, due to the lack of galvanic isolation in the low voltage grid interconnections of these inverters, the PV systems become vulnerable to leakage currents flowing through the grounded star point of the distribution transformer, the earth, and the distributed parasitic capacitance of the PV modules. These leakage currents are prohibitive, since they constitute an issue for safety, reliability, protection coordination, electromagnetic compatibility, and module lifetime. This paper investigates a wide range of multi-kW range power rating TPVI topologies and classifies them in terms of their leakage current attributes. This systematic classification places most topologies under a small number of classes with basic leakage current attributes. Thus, understanding and evaluating these topologies becomes an easy task. In addition, based on these observations, new topologies with reduced leakage current characteristics are proposed in this paper. Furthermore, the important efficiency and cost determining characteristics of converters are studied to allow design engineers to include cost and efficiency as deciding factors in selecting a converter topology for PV applications.

New Beamforming Technique for ZF-THP Based on SSLNR (SSLNR 기반의 ZF-THP를 위한 새로운 빔형성 기법)

  • Cho, Yong-Seock;Byun, Youn-Shik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.4
    • /
    • pp.350-359
    • /
    • 2013
  • In this paper, Inter user interference elimination algorithm based on Block Diagonal Geometric Mean Decomposition(BD-GMD) for eliminating inter user interference apply to Zero-Forcing in the Successive Signal to Leakage plus Noise Ratio(SSLNR) in Coordinated Multi-Point Coordinated Beamforming system(CoMP CB). As a result, the leakage power is eliminated. The inter user interference elimination algorithm, however, cannot guarantee the enough desired signal power therefore we perform the channel ordering to overcome this disadvantage and increase the desired signal power. The simulation results show that the proposed scheme provides the improved Bit Error Rate(BER) performance compared with existing SSLNR-Zero-Forcing-Tomlinson Harashima precoding(SSLNR-ZF-THP).

A study case on application of a total monitoring device of leakage current in transformer (변압기 누설전류 통합 감시장치 적용사례)

  • Lee, Jung-Eun;Choi, Hong-Kyoo;Kim, Young-Kyu;Park, Hyung-Min;Song, Young-Joo;Yoo, Hai-Chool
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.51-54
    • /
    • 2009
  • Total monitoring device of leakage current in transformer can detects the flowing leakage current on the ground wire connected with the neutral point, and that is monitored at real-time by the transfer. If the over-flowing current is detected, Total monitoring device of leakage current in transformer will warn the administrator to prevent electrical accident. In this thesis, we are going to explain about Total monitoring device of leakage current in transformer. Also we measure leakage current and judge safety in customer.

  • PDF

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.