• Title/Summary/Keyword: leakage hole

Search Result 131, Processing Time 0.028 seconds

A Study on the Factors Affecting the Influence Ranges of Ammonia Leakage by Using KORA Program (KORA 프로그램을 활용한 암모니아 누출사고 영향범위 결정 기여요인 연구)

  • Lim, Hyeongjun;Kwak, Sollim;Jung, Jinhee;Ryu, Taekwon;Choi, Woosoo;Lee, Jieun;Lee, Jinseon;Lee, Yeonhee;Kim, Jungkon;Yoon, Junheon;Ryu, Jisung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.38-44
    • /
    • 2018
  • Ammonia is used primarily as a refrigerant in refrigeration facility and SCR of a plant, and is frequently involved in leakage accidents. This study was conducted by selecting ammonia, a material with a wide influence range when evaluated, as a material with higher vapor pressure and lighter than air. In this study, the influence ranges were computed using KORA(Korea Off-site Risk Assessment supporting tool) with four different environmental factors : ground roughness, sealing, operating temperature, pressure, and leakage hole size. As a result, the difference in the influence range of ground roughness is approximately 4.62 times, while the ammonia storage tank shows a difference in the reduction rate of 0.64 when sealed. The extent of impact increased with increasing leakage depending on storage temperature and pressure, and when storing higher than the saturation vapor pressure, the impact range showed an average growth rate of 3.45 % per 0.1 Mpa($45^{\circ}C$). The influence ranges based on the size of the leakage holes is shown to be proportional to the area of the leakage zone.

Analysis of the Damaged Range Caused by LPG Leakage and Vapor Clouds Considering the Cold Air Flow (찬공기 흐름을 고려한 LPG 누출 및 증기운에 의한 피해 영향 범위 분석)

  • Gu, Yun-Jeong;Song, Bonggeun;Lee, Wonhee;Song, Byunghun;Shin, Junho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.27-35
    • /
    • 2022
  • When LPG leaks from the storage tank, the gas try to sink to the ground because LPG is heavier than air. The gas easily creates vapor clouds causing aggressive accidents in no airflow. Therefore, It is important to prevent in advance by analyzing the damaged range caused from LPG leakage and vapor clouds. So, this study analyzed the range of damaged by LPG leakage and vapor clouds with consideration of the cold air flow which is generated by the topographical characteristics and the land use status at night time in the Jeju Hagari. As a result of the cold air flow using KLAM_21, about 2 m/s of cold air was introduced in from the southeast due to the influence of the terrain. The range of damaged by LPG leakage and vapor cloud was analyzed using ALOHA. When the leak hole size is 10 cm at the wind speed of 2 m/s, the range corresponding to LEL 60 % (12,600 ppm) was 61 m which range is expected to influence in nearby residential areas. These results of this study can be used as basic data to prepare preventive measures of accidents caused by vapor cloud. Forward, it is necessary to apply CFD modeling such as FLACS to check the vapor cloud formation due to LPG leakage in a relatively narrow area and to check the cause analysis.

Effect of the Plasma-assisted Patterning of the Organic Layers on the Performance of Organic Light-emitting Diodes

  • Hong, Yong-Taek;Yang, Ji-Hoon;Kwak, Jeong-Hun;Lee, Chang-Hee
    • Journal of Information Display
    • /
    • v.10 no.3
    • /
    • pp.111-116
    • /
    • 2009
  • In this paper, a plasma-assisted patterning method for the organic layers of organic light-emitting diodes (OLEDs) and its effect on the OLED performances are reported. Oxygen plasma was used to etch the organic layers, using the top electrode consisting of lithium fluoride and aluminum as an etching mask. Although the current flow at low voltages increased for the etched OLEDs, there was no significant degradation of the OLED efficiency and lifetime in comparison with the conventional OLEDs. Therefore, this method can be used to reduce the ohmic voltage drop along the common top electrodes by connecting the top electrode with highly conductive bus lines after the common organic layers on the bus lines are etched by plasma. To further analyze the current increase at low voltages, the plasma patterning effect on the OLED performance was investigated by changing the device sizes, especially in one direction, and by changing the etching depth in the vertical direction of the device. It was found that the current flow increase at low voltages was not proportional to the device sizes, indicating that the current flow increase does not come from the leakage current along the etched sides. In the etching depth experiment, the current flow at low voltages did not increase when the etching process was stopped in the middle of the hole transport layer. This means that the current flow increase at low voltages is closely related to the modification of the hole injection layer, and thus, to the modification of the interface between the hole injection layer and the bottom electrode.

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.193-201
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.

Analysis for Cause of Corrosion and Gas Leakage on LP-Gas Cylinder (LP가스 용기의 부식 및 가스누출 원인 분석)

  • Choi S. C.;Jo Y. D.;Kweon J. R.;Kim J. Y.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.52-59
    • /
    • 2001
  • Factors to cause accidents were investigated through a systematic analysis of leakage accidents in welded LP-gas cylinder between 199 and 1999. As a result It was showed that most of leakage accident occurred at the pin-hole due to the localized corrosion on welded zone in cylinder. Accordingly, in this paper, we suggested that the problems of heat treatment condition in two-piece welded cylinder and substitute proposal for preventing the tearing of T zone in three-piece welded cylinder. Furthermore, corrosion rate on the weldment and base metal of welded LP-gas cylinder was evaluated using the electrochemical tests in acid rain and $3.5\%NaCl$ solution, Also, the poor adhesion and defects of film which was produced by electrostatic powder spray painting, while the LP-gas cylinder was manufactured, were analyzed using SEM(Scanning Electron Microscopy). And we proposed a optimum coating thickness of the cylinder.

  • PDF

The Study on Cutting-off the Leachate Leakage or Infiltration from Waste Landfill by Wall Mass Constructed in Underground (지중 시공 벽체의 매립장 침출수 차단성 연구)

  • Koh, Yong-IL
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.10
    • /
    • pp.27-34
    • /
    • 2018
  • The effect of cutting-off the leakage was identified by the cement based wall mass constructed in underground, as complete facilities for reinforcement in shear strength of landfill which was subjected to circular failure and for cutting-off the leachate from the costal waste landfill. By (1) visual inspection after underground excavating and (2) compressive strength test for core of underground wall, it could be identified that quality of wall mass constructed in underground was so effective, and by additional test, so as (3) in-situ permeability test in the hole after coring wall mass, (4) analyzing the characteristics of basic components and their profiles through the series of chemical experiments and (5) deciding the general distribution patterns from the chromatograms using GC-MS, it could be identified that watertight and cutting-off the leachate of wall mass constructed in underground was very effective. Therefore, it is concluded that five types of tests suggested in this study can judge the effect of cutting-off the leakage or infiltration of very high concentrated leachate from the waste landfill.

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.274-282
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.

A Study on Installation of Carbon Monoxide Detector in a Building (건축물내 일산화탄소 경보기 설치에 관한 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Oh, Jeong-Seok
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2008.04a
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

Fatigue Characteristic Evaluation in Water Pipe Welds Considering of Welding Residual Stress (용접잔류응력을 고려한 상수도 강관의 피로특성 평가)

  • Choi, Jung-Hun;Song, Weon-Keyu;Koo, Jae-Mean;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.7-10
    • /
    • 2007
  • In case of large steel water pipe, it have been observed that its fracture mostly occurs due to the complicated outside fatigue load on the pipe in the underground. It is also well known that its damage and leakage happen mainly in a weld zone. In this study we evaluated the fatigue characteristics based on size effect and residual stress by comparing the test results on the standard specimen collected from real pipe with those on full scale pipe.

  • PDF

Fabrication and characteristics of limit-current type oxygen sensor with monolith aperture structure (일체화된 Aperture 구조의 한계전류형 산소센서의 제작 및 특성)

  • Oh, Young-Jei;Lee, Deuk Yong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.273-280
    • /
    • 2008
  • Monolith aperture-type oxygen sensors with simple structure of YSZ(pin-hole)/Pt/ YSZ(solid electrolyte)/Pt were fabricated by co-firing technique. To enhance the yield of productivity, a couple of YSZ green sheets for diffused barrier and solid electrolyte were prepared by tape-casting and co-firing method. The limit current characteristics of the oxygen sensors were measured between 500 and $650^{\circ}C$ The heating temperature of $600^{\circ}C$ was optimum as a portable oxygen sensor in the range of oxygen concentration from 0 to 75 vol%. Linear proficiency of limit current behavior as a function of oxygen concentration was controlled by the variation of aperture dimension. The fabricated oxygen sensors showed the stable sensing output for 30 days. Gas leakage in bonding area due to warping, cracking and thermal cycling was not found in the period.