• Title/Summary/Keyword: leakage detector

Search Result 105, Processing Time 0.024 seconds

Optimum Design of a Non-Destructive Testing System to Maximize Magnetic Flux Leakage

  • Park, G.S;Jang, P.W;Rho, Y.W
    • Journal of Magnetics
    • /
    • v.6 no.1
    • /
    • pp.31-35
    • /
    • 2001
  • This paper describes the design method of a magnetic system to maximize the magnetic flux leakage (MFL) in a non-destructive testing (NDT) system. The defect signals in a MFL type NDT system mainly depend on the change of the magnetic leakage flux in the region of a defect. The characteristics of the B-H curves are analysed and a design method to define the operating point on B-H curves for maximum leakage is performed. The computed MFL signal by a nonlinear finite element method is verified by measurement using Hall sensors mounted on the 6 legs PIG, the traveling detector unit in gas pipe, in an 8 inch test tube with defects. The rhombic defects could be successfully identified from the defect signals.

  • PDF

Design of a Full-Wave Rectifier with Vibration Detector for Energy Harvesting Applications (에너지 하베스팅 응용을 위한 진동 감지기가 있는 전파정류 회로 설계)

  • Ka, Hak-Jin;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.421-424
    • /
    • 2017
  • This paper describes a full-wave rectifiers for energy harvesting circuit using vibration detector. The designed circuit operates only when the vibration is detected through the vibration detector and the active diode. When there is no vibration, the comparator is turned off to prevent leakage of energy stored in the $C_{STO}$. The energy stored in the capacitor is used to drive the level converter and the active diode. The energy stored in the capacitor is supplied to an active diode designed as an output power. The vibration detector is implemented with Schmitt Trigger and Peak Detector with Hysteresis function. The proposed circuit is designed in a CMOS 0.35um technology and its functionality has been verified through extensive simulations. The designed chip occupies $590{\mu}m{\times}583{\mu}m$.

  • PDF

Measurement from Moving Vehicle Health Screening Outside of The Leakage Dose (이동건강검진차량에서 외부의 누설선량 측정)

  • Han, Beom-Hee;Han, Sang-Hyun;Mo, Eun-Hee;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.192-198
    • /
    • 2015
  • Checked out by the moving vehicle health checks for patients, practitioners, and the increase in radiation dose outside the vehicle, but an investigation into the leakage of radiation can still be negligible. In this study, through experimental results were as follows: Dose that occurs most often where the leak in the right door $1.14{\pm}1.75mR/h$, X-ray generator in terms of proximity to the top $0.65{\pm}1.25mR/h$, X-ray generator and away to the bottom in terms $0.91{\pm}1.25mR/h$, the adjacent rear detector in the upper part $96.98{\pm}158.88mR/h$ dose of the leak appeared in various locations. By measuring position from the rear of the adjacent detector $67.48{\pm}97.03mR/h$ dose had the highest leakage into. Generating device for diagnosis of radiation safety regulations regarding the maximum leakage dose per week, but all met back when it is displayed in the leakage dose Hourly rates do not ignore the leakage radiation dose were measured. Therefore, a mobile health screening in a vehicle outside of the leakage radiation dose to the liver and move on we are not interested twelve barrier leakage radiation dose of defense has a chance to re-evaluate the standards required, and move the vehicle health check using the X-ray increases as the dose per hour, depending on the criteria for choosing the appropriate measures that will require effort.

A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode (마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • We developed very small parallel plate radiation detector by using our existing experience of mating radiation dosimeter and capability of analyzing characteristics of dosimeter. The radiation detector was consisted of microfilm and carbon electrode. The detector was parallel plate type of all-filled ionization chamber. The ionization chamber had been fabricated using an acrylic plate for the air cavity and carbon coated microfilm for electrical configuration. The alr gap between two electrodes was 0.48 mm. The diameters of collect electrode and guard electrode were 3.3 mm, 5 mm respectively. The diameter of high voltage electrode was 5 mm. Nominal sensitive volume of the chamber was 0.016 ㎤. The major parameters of the chamber characteristics such as leakage current, reproducibility, dose rate effect, and polarity effect were measured. The experimental results were as followings. Leakage current was 0.1 pA. Standard deviation of reproducibility was less than 0.1%. Dose rate effect was less than 1.5%. Polarity effect was less than 2.4%. These data were comparable to those of commercially available dosimetric system for QA-purpose. As the result, we found that the radiation detector consisting of the ionization chamber, microfilm and carbon electrode, was satisfactory for the purpose of the small field dosimetry in size and characteristics. In the future, We will try to refine the dosimeter for use in very small volume.

  • PDF

The Comparision of X-ray Detection Characteristics as Additive ratio of As in a-Se of $BrO_2/a-Se$ Film ($BrO_2/a-Se$ 필름의 a-Se에 첨가된 As 변화에 따른 X선 검출특성 비교)

  • Park, Ji-Koon;Choi, Jang-Yong;Kim, Dae-Hwan;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.424-427
    • /
    • 2002
  • In this papaer, there is a basic research for the development of the Hybrid digital radiation detector with a new system, make up for existing digital radiation detector of direct/indirect method with a weak point. for enhance the efficiency characteristics of signal response from X-ray detector using the a-Se, We make sample with various kinds of layer, through the ratio of As(0.l%,0.3%,0.5%,1%,1.5%,5%,10%). We measure net charge with a leakage current and photo current for electric charateristics. Ratio of As in a-Se consist of 7 stage, It made of using the thermal deposition system, In the made of samples, we made multi layer using the EFIRON optical adhesives from phosphor layer consist of Oxybromide$(BrO_2)$. As a result of X-ray measurement, the best result is ; leakage current(0.30nA/cm2), net charge(610.13pC/cm2/mR) when the condition is voltage(9V/um), 0.3% ratio of As in multi layer(BrO2 + a-Se)

  • PDF

AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF MARGINAL LEAKAGE USING A RADIOACTIVITY (충전후 방사능에 의한 변연누출 측정에 관한 실험적 연구)

  • Kim, Mi-Ja;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.69-78
    • /
    • 1988
  • The study was designed to establish a more nearly quantitative method for assessing the marginal leakage of dental restorations. 27 Class V cavities with $45^{\circ}$ bevel joint were prepared and classified into 2 groups. One group was filled with Scotchbond and silux. The other group was filled with glass ionomer cement, Scotchbond and silux. After finishing, all specimens were subjected manually to 100 thermal cycles at $0^{\circ}C$ and $100^{\circ}C$ water-bath. They were soaked in a samarium nitrate solution for 3 hours, irradiated with flux of $6{\times}10^{12}$ neutrons/$cm^2$/sec for 11 hours, cooled for 200 hours, counted with the HPGE detector and the tracer uptake was determined by comparison with a standard of samarium (10 ${\mu}g$). The following results were obtained. 1. Both of the two groups showed a considerable amounts of marginal leakage. 2. The group filled without glass ionomer cement base showed more marginal leakage than the group filled with glass ionomer cement base. 3. Neutron Activation Analysis produced a good quantitative method to measure the marginal leakage and samarium was appropriate to measure the marginal leakage of resin restorations using neutron activation analysis.

  • PDF

X-ray Sensitivity of Hybrid-type Sensor based on CaWO4-Selenium for Digital X-ray Imager

  • Park, Ji-Koon;Park, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.133-137
    • /
    • 2004
  • The development of digital x-ray detector has been extensively progressed for the application of various medical modalities. In this study, we introduce a new hybrid-type x-ray detector to improve problems of a conventional direct or indirect digital x-ray image technology, which composed of multi-layer structure using a CaWO$_4$ phosphor and amorphous selenium (a-Se) photoconductor. The leakage current of our detector was found to be ∼180 pA/cm$^2$ at 10 V/m, which was significantly reduced than that of a single a-Se detector. The x-ray sensitivity was measured as the value of 4230 pC/cm$^2$/mR at 10 V/m. We found that the parylene thin film between a CaWO$_4$ phosphor and an a-Se layer acts as an insulator to prevent charge injection from indium thin oxide (ITO) electrode into an a-Se layer under applied bias.

A Study on Radiation Hardening of a Infrared Detector (적외선 탐지소자의 내방사선화 연구)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.490-492
    • /
    • 2005
  • A study on radiation hardening of infrared(IR) detector, the chief component of IR camera was performed. The radiation test on IR sensor passivated with the ZnS by Co$^{60}$ gamma-ray over 1 Mrads showed the reduction in Ro by 1/100 which was related to the noise level. This effect that was caused by carrier trapping in the ZnS passivation layer increased the leakage current and resulted in degradation in the device performance. For the radiation hardening of IR devices we suggested the ones with CdTe passivation layer which had a tendency to reluctant to carrier trapping in its layer and developed test patterns. Radiation test to the patterns showed that the our CdTe passivated device could survived over 1 Mrad gamma-ray dose.

The characteristic study of hybrid X-ray detector using CdTe and Zns:AgCl phosphor (CdTe 와 ZnS:AgCl phosphor를 이용한 Hybrid형 X선 검출기의 특성연구)

  • Seok, Dae-Woo;Kang, Sang-Sik;Kim, Jin-Young;Park, Ji-Koon;Mun, Chi-Woong;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.71-74
    • /
    • 2003
  • Photoconductor for direct detection fiat-panel imager present a great materials challenge, since their requirement include high X-ray absorption, ionization and charge collection, low leakage current and large area deposition, CdTe is practical material. We report studies of detector sensitivity, That is an CdTe with $5{\mu}m$ thickness on glass. That is hybrid layer of depositting ZnS:AgCl phosphor with $100{\mu}m$ on CdTe. The leakage current of hybrid is similar to it of a-Se, but photocurrent is larger than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

A Basic Study for the Performance Evaluation of a Raman LiDAR Detector for Detecting Hydrogen Gas (수소 가스 검출용 라만 라이다 측정기의 성능 평가를 위한 기초 연구)

  • WONBO CHO;YUNKYU LIM;YANGKYUN KIM;BYOUNGJIK PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.205-211
    • /
    • 2023
  • Hydrogen gas is light and diffuses very quickly. Therefore, when a leakage accident occurs, the damage is great, so a technology that can quickly measure the leakage in the air at a long distance is needed. In order to develop hydrogen gas leaked in the atmosphere in a non-contact manner, an experiment was performed to measure hydrogen gas using a lidar technology using the Raman effect. Hydrogen Raman signals were detected using a UV LED light source, which is a Raman light source, and a spectrometer in the ultraviolet region including an optical filter in the 400-430 nm band. To develop this, a Raman lidar optical structure was designed to measure the hydrogen Raman signal at a certain distance, and the hydrogen Raman spectrum was confirmed using a standard gas to evaluate the performance of this optical structure. The linearity was found to be 0.99 using hydrogen standard gas (10, 50, 100, 500, 1,000 ppm). Accordingly, a Raman lidar capable of measuring hydrogen gas rapidly diffusing in the air in an open state was developed to improve the limitations of existing hydrogen sensors.